Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Specific Gamma-Ray Dose Constants with Current Emission Data

The specific gamma-ray dose constant represents the gamma effective dose rate due to a point source of unit activity of a given nuclide at 1 m. New tabulations of specific gamma-ray dose constants have been made using current gamma emission data from the SCALE 6.2.3 software package and International Commission on Radiological Protection Publication 107, combined with the effective dose per fluence conversion coefficients (antero-posterior orientation) of International Commission on Radiological Protection Publication 116. SCALE data cover 1,264 nuclides, and International Commission on Radiological Protection Publication 107 data include 1,192 nuclides, with only 777 nuclides in common between the two sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlations between energy and $\gamma$-ray emission in 239 Pu($n, f$)

Here, we study $\gamma$-ray emission following $^{239}\mathrm{Pu}(n,\mathrm{f})$ over an incident neutron energy range of $2 < E_i < 40$ MeV. We present the first experimental evidence for positive correlations between the total angular momentum generated in fission and the excitation energy of the compound nucleus prior to fission. The $\gamma$-ray multiplicity increases linearly with incident energy below the 2\textsuperscript{nd}-chance fission threshold with a slope of $0.085 \pm 0.010$~MeV$^{-1}$. This linear trend appears to hold for the average excitation energy of the compound nucleus between $9 < \langle E_x \rangle < 19$ MeV. Most of the multiplicity increase comes from an enhancement around a $\gamma$-ray energy of 0.7 MeV, which we interpret as stretched quadrupole $\gamma$ rays that indicate an increase in total fission-fragment angular momentum with excitation energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cross-correlation of the extragalactic gamma-ray background with the thermal Sunyaev-Zel’dovich effect in the cosmic microwave background

Cosmic rays in galaxy clusters are unique probes of energetic processes operating with large-scale structures in the Universe. Precise measurements of cosmic rays in galaxy clusters are essential for improving our understanding of nonthermal components in the intracluster medium (ICM) as well as the accuracy of cluster mass estimates in cosmological analyses. In this paper, we perform a cross-correlation analysis with the extragalactic gamma-ray background and the thermal Sunyaev-Zeldovich (tSZ) effect in the cosmic microwave background. The expected cross-correlation signal would contain rich information about the cosmic-ray-induced gamma-ray emission in the most massive galaxy clusters at $\textit{z}$ ~ 0.1 – 0.2 . We analyze the gamma-ray background map with 8 years of data taken by the Large Area Telescope onboard Fermi satellite and the publicly available tSZ map by Planck. We confirm that the measured cross-correlation is consistent with a null detection, and thus it enables us to put the tightest constraint on the acceleration efficiency of cosmic-ray protons at shocks in and around galaxy clusters. In this work, we find the acceleration efficiency must be below 5% with a 2σ confidence level when the hydrostatic mass bias of clusters is assumed to be 30%, and our result is not significantly affected by the assumed value of the hydrostatic mass bias. Our constraint implies that the nonthermal cosmic-ray pressure in the ICM can introduce only a≲3% level of the hydrostatic mass bias, highlighting that cosmic rays alone do not account for the mass bias inferred by the Planck analyses. Finally, we discuss future detectability prospects of cosmic-ray-induced gamma rays from the Perseus cluster for the Cherenkov Telescope Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-mirror resonator for next-generation Compton gamma-ray source

The next-generation Compton gamma-ray sources (CGSs) based on storage rings require a high-power, well-focused laser beam as a photon driver, which can be realized using a Fabry-Perot cavity (FPC). In this work, we reexamine the behavior and performance of a two-mirror, nearly concentric resonator by introducing a new figure of merit representing the cavity’s proximity to instability. This figure of merit is used to analyze various aspects of the cavity design, including misalignment, beam coupling limitations, and beam size scaling. We then examine several factors affecting the gamma-ray flux, such as the interaction area, crossing angle for collision, frequency matching between the electron and laser beams, and intrabeam scattering effects. Using an example CGS, we demonstrate how to make improved design choices for a two-mirror resonator to enhance the gamma-ray beam flux. This work shows that simple two-mirror Fabry-Perot cavities are well suited as the laser driver for the next-generation storage ring-based CGS, while offering superior advantages in gamma-ray beam polarization control compared to more complex four-mirror, nonplanar resonators.

Delooze, Will↗

Dose Rate Effects in the Aging of Nuclear Cable Insulation Subjected to Gamma Radiation

In nuclear power plants (NPPs), the aging of polymer-based electrical cable insulation must be effectively monitored to ensure the safe and reliable operation of NPPs. Gamma radiation is one of the main environmental stressors causing degradation of cable insulation. For a given total dose of absorbed gamma radiation, damage due to gamma irradiation may be dose rate dependent. The purpose of this work is to confirm whether a dose rate effect exists for the cable insulation made by crosslinked polyethylene (XLPE) and ethylene propylene rubber (EPR), quantify the relationship between degradation rate and dose rate, and explore the correlation of different measured properties. The dose rate effects at 1800 Gy/h, 200 Gy/h, and 100 Gy/h using 60Co gamma irradiation on cable aging was studied. Different types of cable insulation, including two XLPEs and one EPR, were irradiated at the different dose rates with a total dose around 300 kGy at 26 °C. The properties of unirradiated and irradiated samples were characterized by mass change, yellowness index, and other ongoing measurements. Dose rate effects were observed for mass change data of XLPE and EPR.

Li, Donghui↗

Statistical (n,$$\gamma $$) cross section model comparison for short-lived nuclei

Abstract Neutron-capture cross sections of neutron-rich nuclei are calculated using a Hauser–Feshbach model when direct experimental cross sections cannot be obtained. A number of codes to perform these calculations exist, and each makes different assumptions about the underlying nuclear physics. We investigated the systematic uncertainty associated with the choice of Hauser-Feshbach code used to calculate the neutron-capture cross section of a short-lived nucleus. The neutron-capture cross section for $$^{73}\hbox {Zn}$$ 73 Zn (n, $$\gamma $$ γ ) $$^{74}\hbox {Zn}$$ 74 Zn was calculated using three Hauser-Feshbach statistical model codes: TALYS, CoH, and EMPIRE. The calculation was first performed without any changes to the default settings in each code. Then an experimentally obtained nuclear level density (NLD) and $$\gamma $$ γ -ray strength function ( $$\gamma \hbox {SF}$$ γ SF ) were included. Finally, the nuclear structure information was made consistent across the codes. The neutron-capture cross sections obtained from the three codes are in good agreement after including the experimentally obtained NLD and $$\gamma \hbox {SF}$$ γ SF , accounting for differences in the underlying nuclear reaction models, and enforcing consistent approximations for unknown nuclear data. It is possible to use consistent inputs and nuclear physics to reduce the differences in the calculated neutron-capture cross section from different Hauser-Feshbach codes. However, ensuring the treatment of the input of experimental data and other nuclear physics are similar across multiple codes requires a careful investigation. For this reason, more complete documentation of the inputs and physics chosen is important.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward extracting $$\gamma $$ from $$B\rightarrow DK$$ without binning

Abstract $$B^\pm \rightarrow DK^\pm $$ B ± → D K ± transitions are known to provide theoretically clean information about the CKM angle $$\gamma $$ γ , with the most precise available methods exploiting the cascade decay of the neutral D into CP self-conjugate states. Such analyses currently require binning in the D decay Dalitz plot, while a recently proposed method replaces this binning with the truncation of a Fourier series expansion. In this paper, we present a proof of principle of a novel alternative to these two methods, in which no approximations at the level of the data representation are required. In particular, our new strategy makes no assumptions about the amplitude and strong phase variation over the Dalitz plot. This comes at the cost of a degree of ambiguity in the choice of test statistic quantifying the compatibility of the data with a given value of $$\gamma $$ γ , with improved choices of test statistic yielding higher sensitivity. While our current proof-of-principle implementation does not demonstrate optimal sensitivity to $$\gamma $$ γ , its conceptually novel approach opens the door to new strategies for $$\gamma $$ γ extraction. More studies are required to see if these can be competitive with the existing methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of Anomalies in Environmental Gamma Radiation Background with Hopfield Artificial Neural Network - Consortium on Nuclear Security Technologies (CONNECT) Q3 Report

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to investigate performance of a Hopfield Neural Network (HNN) in in detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign. One data set contained a 137 Cs source, and another dataset contained a 131 I source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Hopfield Artificial Neural Network for Anomaly Detection in Environmental Gamma Radiation Background: Consortium on Nuclear Security Technologies (CONNECT) (Q2 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore supervised machine learning (ML) algorithms for development of a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm for detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Anomalies in Gamma Background Radiation Data with K-Means and Self-Organizing Map Clustering Algorithms (Consortium on Nuclear Security Technologies (CONNECT) Q1 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. The challenge is that spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma Irradiation of NaCl-UCl 3 Salt for the Molten Chloride Fast Reactor

This report documents the results of the gamma ray irradiation of NaCl-UCl 3 eutectic salt in the Advanced Test Reactor (ATR) spent fuel pool gamma tube and subsequent analysis of capsules utilizing the Gas Assay Sample and Recharge (GASR) system. NaCl-UCl 3 salt capsules at four different temperatures, 75C, 150C, 300C and 600C, were irradiated shortly after the core internal changeout (CIC) of the ATR, beginning April 28 th of 2021, and ending on August 18 th of 2021. Re-positioning of the fuel elements in the spent fuel pool to move more fresh fuel elements around the gamma tube occurred on May 11 th of 2021, resulting in an approximate 20% increase in the dose rate and consequently the total absorbed dose. In total, the salt-filled capsules underwent 2638 hours of gamma irradiation from the adjacent freshly discharged ATR spent fuel. Capsule internal pressure measurements were taken via the Gas Assay Sample and Recharge (GASR) system in the INL Hot Fuels Examination Facility (HFEF) following completion of the irradiation. Based on the GASR analysis results, the primary conclusion from this experiment to-date is that radiolytic generation of chlorine gas is insignificant for the dose rates and total absorbed dose that these samples experienced. To elucidate more detailed effects of radiolysis on NaCl-UCl 3 eutectic salts and reach a more definitive conclusion, further advanced analyses such as electron microscopy, simultaneous thermal analysis, and electron paramagnetic resonance are recommended to analyze the capsule wall and salt samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

User Manual for MC 2 -3 Gamma Library Generation

This report provides the documentation for the revised procedure to generate the MC 2 -3 gamma library with the latest versions of PreGAMMA and GenGAMMA which have recently been updated to fix the program errors and inconsistent data processing for some isotopes identified in a recent verification and validation study of the MC 2 -3 gamma library. A few associated errors associated with gamma processing were also identified and fixed in the MC 2 -3 code. Addressing the changes in MC 2 -3, the procedure to generate the PMATRX and GAMISO datasets is discussed as well. The input data of PreGAMMA and GenGAMMA are discussed in detail using sample input data. In addition, the structure and formats of the MC 2 -3 gamma library are provided in detail.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Coincidence Counting for Improving Minimal Detectable Activity of 110m Ag in Single Particle Gamma Analysis

Post-irradiation examination (PIE) of fuel particles from the fourth Advanced Gas Reactor Fuel Development and Qualification (AGR) Program irradiation (AGR-5/6/7) is being performed at Oak Ridge National Laboratory (ORNL). Tristructural isotropic (TRISO)-coated particles and associated compacts for the AGR-5/6/7 experiment fabricated by BWX Technologies Nuclear Operations Group were formed into a graphite matrix compact and irradiated at the Advanced Test Reactor at Idaho National Laboratory. At ORNL, particles are deconsolidated from the graphite matrix compact and individually scanned for emitted gamma rays with the Irradiated Microsphere Gamma Analyzer (IMGA). The IMGA system comprises a single high purity germanium (HPGe) detector, an automated particle handling vacuum system, and an ORTEC DSPEC-50 digital spectrometer for gamma ray analysis. IMGA quantifies gamma ray-emitting fission product inventories of individual TRISO particles, and these inventories can be compared with the measured average inventories per particle and radionuclide inventories predicted by AGR-5/6/7 physics calculations to determine if a particle experienced radionuclide release. Details on IMGA data collection methods can be found in the literature. The TRISO particle’s SiC layer provides structural support, as well as a barrier for fission product release during irradiation or subsequent safety testing. A weakened or compromised SiC layer can be identified by the release of radionuclides, such as 137 Cs, which is detected by IMGA. However, select radionuclides, such as 90 Sr, 110 mAg, and 154 Eu have been shown to migrate through an intact SiC layer. Measurement of the radionuclide 110 mAg is significant as its release has been shown to be particularly sensitive to in-reactor conditions (e.g., temperature) with broad variable particle to-particle release behaviors observed within a single compact. As such, 110 mAg activity is often used for particle selection for comprehensive PIE as bounding 110 mAg retention particles are hypothesized to represent limits in particle behaviors within a compact. As TRISO particle fuel PIE activities continue over time, IMGA measurements of the 110 mAg inventory are eventually hindered because of its relatively short half-life (~250 days). As the fuel ages from its end of irradiation (EOI) date, the measurement uncertainty and minimum detectable activity (MDA) of 110m Ag increase because the detector background continuum begins to dominate. For particles from the second AGR irradiation experiment (AGR-2), the 110m Ag MDA was above 20% of the calculated average particle inventory after approximately five half-lives, and 110m Ag activity was no longer measurable with IMGA after approximately seven half-lives. Therefore, coincidence counting approaches have been explored to determine feasibility of leveraging new approaches to overcome limitations associated with increasing MDA over time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Xtreme progenitors of Gamma-ray bursts [Slides]

Gamma-ray burst are typically classified as “short” or “long." They are categorized by their gamma ray emission, Short GRBs have gamma-ray emission less than 2 seconds and long GRBs are greater 2 seconds. Within long GRBs, further categorized as radio-loud or quiet. Radio loud are more energetic and have longer gamma-ray emission. We’re studying a binary system with a massive star and black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma Converter Box Preliminary Design [Slides]

Objective: Develop a test capability near Godiva IV fast burst reactor to maximize gamma dose to neutron dose ratio and gain increase in gamma dose over free field. Goal: Maximize gamma dose to neutron dose ratio and gain increase in gamma dose over free field.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methodology to Generate Decay Gamma Sources for the Second Target Station Full Target Assembly

This report details the specifics of applying the Position-Averaged Method to the target wedges and staves. The methodology used to calculate the decay gamma sources for a single target wedge to the calculation of the Second Target Station (STS) target assembly activation and the resulting decay gamma source terms are detailed in this report. The methodology has been applied to the entire STS target assembly including all of the target wedges, staves, shaft, and drive. The target staves and shaft have been vertically segmented to ensure the decay gamma source gradient is sufficiently captured. MCNP ® Code Version 6.2.0 with the RNUCS patch coupled with CINDER2008 from the AARE V1.0 package are the main tools used to calculate the decay gamma source terms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the Approximate Bayesian Computation Algorithm to Gamma-Ray Spectroscopy

Radioisotope identification (RIID) algorithms for gamma-ray spectroscopy aim to infer what isotopes are present and in what amounts in test items. RIID algorithms either use all energy channels in the analysis region or only energy channels in and near identified peaks. Because many RIID algorithms rely on locating peaks and estimating each peak’s net area, peak location and peak area estimation algorithms continue to be developed for gamma-ray spectroscopy. This paper shows that approximate Bayesian computation (ABC) can be effective for peak location and area estimation. Algorithms to locate peaks can be applied to raw or smoothed data, and among several smoothing options, the iterative bias reduction algorithm (IBR) is recommended; the use of IBR with ABC is shown to potentially reduce uncertainty in peak location estimation. Extracted peak locations and areas can then be used as summary statistics in a new ABC-based RIID. ABC allows for easy experimentation with candidate summary statistics such as goodness-of-fit scores and peak areas that are extracted from relatively high dimensional gamma spectra with photopeaks (1024 or more energy channels) consisting of count rates versus energy for a large number of gamma energies.

Burr, Tom↗