Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “functional replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

β-Functionalized push–pull opp -dibenzoporphyrins as sensitizers for dye-sensitized solar cells: the push group effect

β-Functionalized push–pull zinc opp-dibenzoporphyrins were designed and synthesized as sensitizers for dye-sensitized solar cells. The utilization of arylamine to replace aliphatic amine as the donor group has been proved to be an effective strategy to solve the solar cell instability reported previously. Three different arylamino groups including carbazole (YH8), diphenylamine (YH9), and phenothiazine (YH10) were investigated as arylamine donor groups, and different electronic effects were observed for these donor groups. Diphenylamine carrying YH9 and phenothiazine carrying YH10 displayed strong push–pull characteristics including segregated HOMO/LUMO and red-shifted and broadened absorption bands. In sharp contrast, the incorporation of carbazole (YH8) cancels out the push–pull effect. YH9 and YH10 solar cells achieved high PCEs of 6.9% and 7.5% respectively, which are comparable to that of the best ruthenium dye, N719 (η = 7.7%), under similar conditions. Here this work demonstrates the great potential of π-extended porphyrins as sensitizers for dye-sensitized solar cells.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An original calibration technique for soft x-ray detectors and its use in the Tore Supra tomographic system

This paper describes in detail the recent progresses which have been made in Tore Supra for developing a new technique of calibration of the soft x-ray (SXR) detectors in the range 1-30 keV. The diode response as a function of the flux of photons resulted accurately linear over almost three orders of magnitude. Apart from a limited number of deficient detectors, promptly replaced with new ones, the spread of the diode responses (84 detectors) is about 20% total of the average value. It allowed the derivation of the calibration factor for each detector of the tomography system. The effect of the environmental temperature, in the range 15 deg. - 40 deg., has also been studied, revealing that up to 35 deg. the linearity of diode response and these calibration factors remain constant. It demonstrates the capability of discriminating slight and localized changes in the two dimensional spatial distribution of the SXR intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of single-crystal elastic moduli of Li RE F 4 ( RE =Y, Gd, and Tb) by resonant ultrasound spectroscopy

The tetragonal fluoro-scheelite Li RE F 4 compounds (RE = rare earth) have been shown to exhibit a variety of useful optical and magnetic properties. While LiYF 4 has been widely studied, many of the fundamental thermodynamic properties of other members of this family remain unknown. Here, we report the complete elastic tensors (C ij ) of single-crystalline LiYF 4 , LiTbF 4 , and LiGdF 4 using resonant ultrasound spectroscopy and density functional theory (DFT). Here we compare the results for LiYF 4 with prior experimental results using time-of-flight ultrasound methods. This is the first report, however, of the experimental elastic tensors of LiTbF 4 and LiGdF 4 . The present results point to a softening of the elastic moduli of the Li RE F 4 system when Y is replaced by the larger ionic radius of Tb or Gd. Furthermore, we find that just 0.3% doping with Nd on the Y site also leads to a slight softening of the moduli. The variation of the elastic moduli as a function of temperature up to 216°C was also measured. A nearly linear softening of all seven independent elastic moduli was observed with increasing temperature. Phonon dispersions and phonon density of states obtained by DFT support the experimental finding of a significantly higher sound velocity due to lighter Y atoms in LiYF 4 , as compared to heavier LiTbF 4 and LiGdF 4 .

36 MATERIALS SCIENCE↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗

The modification of the nonlinear guiding center theory

We modify the NonLinear Guiding Center theory for perpendicular diffusion by replacing the spectral amplitude of the two-component model of magnetic turbulence with that of the two-dimensional model (following Shalchi), and replacing the constant a {sup 2}, which indicates the degree particles following the magnetic field line, with the variable a'{sup 2} as a function of the magnetic turbulence. We combine the modified model with the NonLinear PArallel diffusion theory to solve perpendicular and parallel diffusion coefficients simultaneously. It is shown that the new model agrees better with simulations. Furthermore, we fit the numerical results of the new model with polynomials, so that the parallel and perpendicular diffusion coefficients can be calculated directly without iteration of integrations, and many numerical calculations can be reduced.

79 ASTRONOMY AND ASTROPHYSICS↗

Enstore with Chimera namespace provider

Enstore is a mass storage system developed by Fermilab that provides distributed access and management of data stored on tapes. It uses a namespace service, PNFS, developed by DESY to provide a filesystem-like view of the stored data. PNFS is a legacy product and is being replaced by a new implementation, called Chimera, which is also developed by DESY. Chimera offers multiple advantages over PNFS in terms of performance and functionality. The Enstore client component, encp, has been modified to work with Chimera, as well as with any other namespace provider. We performed high load end-to-end acceptance test of Enstore with the Chimera namespace. This paper describes the modifications to Enstore, the test procedure and the results of the acceptance testing.

Litvintsev, Dmitry↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structure of an Odorant-Vinding Protein form the Mosquito Aedes aegypti Suggests a Binding Pocket Covered by a pH-Sensitive

The yellow fever mosquito, Aedes aegypti, is the primary vector for the viruses that cause yellow fever, mostly in tropical regions of Africa and in parts of South America, and human dengue, which infects 100 million people yearly in the tropics and subtropics. A better understanding of the structural biology of olfactory proteins may pave the way for the development of environmentally-friendly mosquito attractants and repellents, which may ultimately contribute to reduction of mosquito biting and disease transmission. Previously, we isolated and cloned a major, female-enriched odorant-binding protein (OBP) from the yellow fever mosquito, AaegOBP1, which was later inadvertently renamed AaegOBP39. We prepared recombinant samples of AaegOBP1 by using an expression system that allows proper formation of disulfide bridges and generates functional OBPs, which are indistinguishable from native OBPs. We crystallized AaegOBP1 and determined its three-dimensional structure at 1.85 {angstrom} resolution by molecular replacement based on the structure of the malaria mosquito OBP, AgamOBP1, the only mosquito OBP structure known to date. The structure of AaegOBP1 (= AaegOBP39) shares the common fold of insect OBPs with six {alpha}-helices knitted by three disulfide bonds. A long molecule of polyethylene glycol (PEG) was built into the electron-density maps identified in a long tunnel formed by a crystallographic dimer of AaegOBP1. Circular dichroism analysis indicated that delipidated AaegOBP1 undergoes a pH-dependent conformational change, which may lead to release of odorant at low pH (as in the environment in the vicinity of odorant receptors). A C-terminal loop covers the binding cavity and this 'lid' may be opened by disruption of an array of acid-labile hydrogen bonds thus explaining reduced or no binding affinity at low pH.

59 BASIC BIOLOGICAL SCIENCES↗

Wire scanner software and firmware issues

The Los Alamos Neutron Science Center facility presently has 110 slow wire scanning profile measurement instruments located along its various beam lines. These wire scanners were developed and have been operating for at least 30 years. While the wire scanners solved many problems to operate and have served the facility well they have increasingly suffered from several problems or limitations, such as maintenance and reliability problems, antiquated components, slow data acquisition, and etc. In order to refurbish these devices, these wire scanners will be replaced with newer versions. The replacement will consist of a completely new beam line actuator, new cables, new electronics and brand new software and firmware. This note describes the functions and modes of operation that LabVIEW VI software on the real time controller and FPGA LabVIEW firmware will be required. It will be especially interesting to understand the overall architecture of these LabVIEW VIs. While this note will endeavor to describe all of the requirements and issues for the wire scanners, undoubtedly, there will be missing details that will be added as time progresses.

43 PARTICLE ACCELERATORS↗

B to tensor meson form factors in the perturbative QCD approach

We calculate the B{sub u,d,s}{yields}T form factors within the framework of the perturbative QCD approach, where T denotes a light tensor meson with J{sup P}=2{sup +}. Because of the similarities between the wave functions of a vector and a tensor meson, the factorization formulas of B{yields}T form factors can be obtained from the B{yields}V transition through a replacement rule. As a consequence, we find that these two sets of form factors have the same signs and correlated q{sup 2}-dependence behaviors. At q{sup 2}=0 point, the B{yields}T form factors are smaller than the B{yields}V ones, in accordance with the experimental data of radiative B decays. In addition, we use our results for the form factors to explore semilteptonic B{yields}Tl{nu}{sub l} decays and the branching fractions can reach the order 10{sup -4}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of Heparin-Coated and Conventional Split-Tip Hemodialysis Catheters

Catheter coatings have the potential to decrease infection and thrombosis in patients with chronic dialysis catheters. We report our midterm experience with a heparin-coated dialysis catheter. This retrospective, case-control study was approved by our Institutional Review Board. A total of 88 tunneled dialysis catheters were inserted over a 13-month period via the internal jugular vein. Thirty-eight uncoated split-tip catheters and 50 heparin-coated catheters were inserted. Primary catheter patency was compared between the two groups using the log rank test, with infection and/or thrombosis considered as catheter failures. Dialysis parameters during the first and last dialysis sessions, including pump speed, actual blood flow, and arterial port pressures, were compared using unpaired t-tests. Primary patency of the uncoated catheters was 86.0 {+-} 6.5% at 30 days and 76.1 {+-} 8.9% at 90 days. Primary patency of heparin-coated catheters was 92.0 {+-} 6.2% at 30 days and 81.6 {+-} 8.0% at 90 days (p = 0.87, log rank test). Infection requiring catheter removal occurred in four patients with uncoated catheters and two patients with heparin-coated catheters (p = 0.23). Catheter thrombosis requiring catheter replacement or thrombolysis occurred in one patient with an uncoated catheter and two patients with heparin-coated catheters (p = 0.9). No differences in catheter function during hemodialysis were seen between the two groups. In conclusion, the heparin-coated catheter did not show a significantly longer patency compared to the uncoated catheter. The flow characteristics of this device were comparable to those of the conventional uncoated catheter. A demonstrable benefit of the heparin-coated catheter in randomized trials is needed before a recommendation for routine implementation can be made.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PHYSLITE - A new reduced common data format for ATLAS

The High Luminosity LHC (HL-LHC) era brings unprecedented computing challenges that call for novel approaches to reduce the amount of real and Monte Carlo-simulated data that is stored, while continuing to support the rich physics program of the ATLAS experiment. With the beginning of LHC Run 3, ATLAS introduced a new common data format, PHYS, that replaces most of the analysis-specific formats that were used in Run 2, and therefore reduces the disk storage significantly. ATLAS also launched the prototype of another common format, PHYSLITE, that is about a third of the size of PHYS. PHYSLITE will be the main format for ATLAS at the HL-LHC and aims to serve 80% of all physics analyses. To simplify analysis workloads and further reduce disk usage it is designed to largely replace user-defined analysis n-tuples and consequently contains pre-calibrated objects. Various forms of validations are in place to ensure correct functionality for users. Developments continue towards HL-LHC to improve the PHYSLITE format further.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multimodal microfluidic platform for controlled culture and analysis of unicellular organisms

Modern live-cell imaging approaches permit real-time visualization of biological processes, yet limitations exist for unicellular organism isolation, culturing and long-term imaging that preclude fully understanding how cells sense and respond to environmental perturbations and the link between single-cell variability and whole-population dynamics. Here we present a microfluidic platform that provides fine control over the local environment with the capacity to replace media components at any experimental time point, and provides both perfused and compartmentalized cultivation conditions depending on the valve configuration. In this work, the functionality and flexibility of the platform were validated using both bacteria and yeast having different sizes, motility and growth media. The demonstrated ability to track the growth and dynamics of both motile and non-motile prokaryotic and eukaryotic organisms emphasizes the versatility of the devices, which with further scale-up should enable studies in bioenergy and environmental research.

59 BASIC BIOLOGICAL SCIENCES↗

A Digital Twin Framework Utilizing Machine Learning for Robust Predictive Maintenance: Enhancing Tire Health Monitoring

We introduce a novel digital twin (DT) framework for the predictive maintenance of long-term physical systems. Using monitoring tire health as an application, we show how the DT framework can be used to enhance automotive safety and efficiency, and how the technical challenges can be overcome using a three-step approach. First, to manage the data complexity over a long operation span, we employ data reduction techniques to concisely represent physical tires using historical performance and usage data. Relying on these data, for fast real-time prediction, we train a transformer-based model offline on our concise dataset to predict future tire health over time, represented as remaining casing potential (RCP). Based on our architecture, our model quantifies both epistemic and aleatoric uncertainties, providing reliable confidence intervals around predicted RCP. Second, to incorporate real-time data, we update the predictive model in the DT framework, ensuring its accuracy throughout its lifespan with the aid of hybrid modeling and the use of the discrepancy function. Third, to assist decision-making in predictive maintenance, we implement a tire state decision algorithm, which strategically determines the optimal timing for tire replacement based on RCP forecasted by our transformer model. This approach ensures that our DT accurately predicts system health, continually refines its digital representation, and supports predictive maintenance decisions. Furthermore, our framework effectively embodies a physical system, leveraging big data and machine learning (ML) for predictive maintenance, model updates, and decision-making.

advanced computing infrastructure↗

A Nonlocal-Gradient Descent Method for Inverse Design in Nanophotonics

Local-gradient-based optimization approaches lack nonlocal exploration abilityrequired for escaping from local minima when searching non-convex landscapes.A directional Gaussian smoothing (DGS) approach was recently proposed in [29]and used to define a truly nonlocal gradient, referred to as the DGS gradient, inorder to enable nonlocal exploration in high-dimensional black-box optimization.Promising results show that replacing the traditional local gradient with the nonlocalDGS gradient can significantly improve the performance of gradient-based methodsin optimizing highly multi-modal loss functions. However, the current DGS methodis designed for unbounded and uncontrained optimization problems, making itinapplicable to real-world engineering optimization problems where the tuningparameters are often bounded and the loss function is usually constrained byphysical processes. In this work, we propose to extend to the DGS approachto the constrained inverse design framework in order to find better optima ofmulti-modal loss functions. A series of adaptive strategies for smoothing radiusand learning rate updating are developed to improve the computational efficiencyand robustness. Our methodology is demonstrated by an example of designing ananoscale wavelength demultiplexer, and shows superior performance compared tothe state-of-the-art approaches. By incorporating volume constraints, the optimizeddesign achieves an equivalently high performance but significantly reduces theamount of material usage.

Bi, Sirui↗

ATR Firewater Pump Replacement

The objective of this project is to replace two faulty firewater pumps at INL's Advanced Test Reactor (ATR). Around ATR, firewater pumps can serve from one to all three of these functions: emergency core injection, emergency canal makeup, and firefighting. Both pumps serve firefighting functions but one also serves the function of emergency canal makeup, a nuclear function, so it is required to go through nuclear grade dedication. Both pumps are currently in the process of being procured.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Thermodynamic Model for the Hanford Tank Waste Operations Simulator - 12193

The Hanford Tank Waste Operations Simulator (HTWOS) is the current tool used by the Hanford Tank Operations Contractor for system planning and assessment of different operational strategies. Activities such as waste retrievals in the Hanford tank farms and washing and leaching of waste in the Waste Treatment and Immobilization Plant (WTP) are currently modeled in HTWOS. To predict phase compositions during these activities, HTWOS currently uses simple wash and leach factors that were developed many years ago. To improve these predictions, a rigorous thermodynamic framework has been developed based on the multi-component Pitzer ion interaction model for use with several important chemical species in Hanford tank waste. These chemical species are those with the greatest impact on high-level waste glass production in the WTP and whose solubility depends on the processing conditions. Starting with Pitzer parameter coefficients and species chemical potential coefficients collated from open literature sources, reconciliation with published experimental data led to a self-consistent set of coefficients known as the HTWOS Pitzer database. Using Gibbs energy minimization with the Pitzer ion interaction equations in Microsoft Excel,1 a number of successful predictions were made for the solubility of simple mixtures of the chosen species. Currently, this thermodynamic framework is being programmed into HTWOS as the mechanism for determining the solid-liquid phase distributions for the chosen species, replacing their simple wash and leach factors. Starting from a variety of open literature sources, a collection of Pitzer parameters and species chemical potentials, as functions of temperature, was tested for consistency and accuracy by comparison with available experimental thermodynamic data (e.g., osmotic coefficients and solubility). Reconciliation of the initial set of parameter coefficients with the experimental data led to the development of the self-consistent set known as the HTWOS Pitzer database. Using Microsoft Excel to formulate the Gibbs energy minimization method and the multi-component Pitzer ion interaction equations, several predictions of the solubility of solute mixtures at various temperatures were made using the HTWOS Pitzer database coefficients. Examples of these predictions are shown in Figure 3 and Figure 4. A listing of the entire HTWOS Pitzer database can be found in RPP-RPT-50703. Currently, work is underway to install the Pitzer ion interaction model in HTWOS as the mechanism for determining the solid-liquid phase distributions of select waste constituents during tank retrievals and subsequent washing and leaching of the waste. Validation of the Pitzer ion interaction model in HTWOS will be performed with analytical laboratory data of actual tank waste. This change in HTWOS is expected to elicit shifts in mission criteria, such as mission end date and quantity of high-level waste glass produced by WTP, as predicted by HTWOS. These improvements to the speciation calculations in HTWOS, however, will establish a better planning basis and facilitate more effective and efficient future operations of the WTP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of instrumentation containing an embedded digital device - 257

The U.S. nuclear power industry primarily relies on mature, well-proven analog technology as the basis for most instrumentation and control (I and C) equipment employed in its nuclear power plants (NPPs). However, the market for this legacy instrumentation is very small and availability of such equipment for spare parts or replacement is increasingly limited. Frequently, modern I and C equipment contains embedded digital devices (EDDs), such as microprocessors and programmable logic devices. While the enhanced functional capabilities provided by the digital components offer improved performance, reliability, and maintainability, the corresponding complexity of sophisticated digital implementations also exacerbate concerns about an increased potential for undetected systematic faults, which can lead to common-cause failure (CCF). As part of a research project sponsored by the U.S. Department of Energy, an investigation has been conducted of commercially available instrumentation marketed for nuclear or industrial application. The objective was to identify the usage of EDDs and to determine the types of functional roles allocated to the devices. Examples of the equipment surveyed include smart sensors, sequencers for emergency diesel generators, pumps, valve actuators, motor control centers, breakers, priority logic modules, and uninterruptible power sources. Where sufficient detail was found, an evaluation was performed to ascertain the nature and role of the digital technology implemented in the instrumentation. The information gained through this investigation serves as technical input for defining a classification approach for EDDs based on the functional impact of the device. For example, the role of an EDD can involve any of the following functions: performance monitoring and diagnostics, information extraction and communication, instrument condition monitoring and protection, or execution of core instrument functions. Classifying digital devices according to their role in the operation of the instrumentation in which they are embedded can enable determination of the potential functional impact of failure of that device and contribute to determination of the potential safety significance of a CCF event disabling all instances of that device. This paper will report on the findings of the investigation of instrumentation with EDDs and indicate considerations for the emerging classification approach. The higher-level goal of this effort is to determine whether a graded approach to qualification testing may be possible based on classification. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗