The pervasive and multifaceted influence of biocrusts on water in the world's drylands
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
RTI has developed a catalytic fast pyrolysis (CFP) process to produce biomass-based hydrocarbon replacement fuels. From a technology perspective, this advanced biofuels process produces liquid transportation fuels that can leverage capital expenditures in the existing petroleum distribution infrastructure. From a business perspective, this technology does not face potential market limitations caused by oxygenate blend limitations for light duty vehicle applications. A promising catalyst has been developed with excellent potential for deoxygenation to produce a hydrocarbon-rich biocrude that is more suitable for upgrading with traditional hydroprocessing technology. The role of the catalyst is to control the chemistry during biomass pyrolysis to produce a biocrude in a single step that has lower oxygen content and is more thermally stable than conventional biomass fast pyrolysis oil. Catalyst properties are optimized to minimize gas and coke production and improve catalytic deoxygenation and biocrude yields. Results from this project have demonstrated that biocrudes from catalytic fast pyrolysis contain <20 wt% oxygen, with the organic fraction as low as 12% oxygen. These oxygen numbers are > 50% lower compared to traditional fast pyrolysis oils. The biocrude produced from our CFP process can be upgraded to gasoline range hydrocarbons. A very conservative approach for upgrading included a preliminary stabilization step followed by a hydroprocessing step. The oxygen content in the upgraded product was decreased by 97% (to less than 3wt %) from the oxygen content of the biocrude sample. Additionally, the acid content was reduced by 99% from the acid content of the biocrude sample. In an optimized integrated process, the CFP step and the hydroprocessing (upgrading) step need to be carefully balanced to maximize the input biomass energy that is recovered in the finished biofuels. Hydrogen utilization and carbon recovery during both catalytic biomass pyrolysis and biocrude upgrading need to be optimized to maximize energy recovery in the finished biofuel. A nominal 1 ton per day (TPD) catalytic biomass pyrolysis system was designed based on the laboratory experimental data. The system was designed to achieve the short residence times (0.5–2 sec) and high heat transfer rates required for maximum liquid biocrude yields while optimizing process integration to maintain catalyst activity by continuous regeneration. The catalytic biomass pyrolysis reactor is a continuously circulating single-loop transport reactor design that is flexible enough to allow sensitivity studies around temperature, residence time, biomass feed rate, and catalyst-to-biomass ratio (i.e., catalyst circulation rate) for process optimization. For a nominal 100 lb/hr feed rate of dry biomass, the products include ~25 lb/hr char and coke, ~20 lb/hr permanent gases, and ~55 lb/hr condensable vapors. Pyrolysis temperatures are 350–600°C, and the system is operated close to ambient pressure. Production of the catalyst developed within the project was scaled up to provide enough material (200kg) for bench-scale testing. The 1TPD bench-scale unit was fabricated, installed and commissioned with this project. Biocrude samples from wood were produced in this unit with the CFP catalyst with material balance > 90%. The intermediate biocrude yields and chemical composition compare well with previous laboratory results and a hydroprocessing strategy for upgrading the resulting biocrude was developed. The experimental results obtained within this project were used to develop a process model for a 2000 TPD commercial facility. Detailed flow sheets were developed for all major unit operations in the process and provided a basis for an economic analysis to develop capital and operating costs. Estimates of the biofuel production costs were used to develop internal rates of return for the yields and compositions measured for the current state of technology at the end of this project and for the yields anticipated for an optimized (nth plant) scenario as additional process improvements are made.
The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.
Background: Rural regions of the western United States have experienced a noticeable surge in both the frequency and severity of acute wildfire events, which brings significant challenges to both public safety and environmental conservation efforts, with impacts felt globally. Identifying factors contributing to immune dysfunction, including endocrinological phenotypes, is essential to understanding how hormones may influence toxicological susceptibility. Methods: This exploratory study utilized male and female C57BL/6 mice as in vivo models to investigate distinct responses to acute woodsmoke (WS) exposure with a focus on sex-based differences. In a second set of investigations, two groups were established within the female mouse cohort. In one group, mice experienced ovariectomy (OVX) to simulate an ovarian hormone-deficient state similar to surgical menopause, while the other group received Sham surgery as controls, to investigate the mechanistic role of ovarian hormone presence in driving immune dysregulation following acute WS exposure. Each experimental cohort followed a consecutive 2-day protocol with daily 4-h exposure intervals under two conditions: control HEPA-filtered air (FA) and acute WS to simulate an acute wildfire episode. Results: Metals analysis of WS particulate matter (PM) revealed significantly increased levels of 63 Cu, 182 W, 208 Pb, and 238 U, compared to filtered air (FA) controls, providing insights into the specific metal components most impacted by the changing dynamics of wildfire occurrences in the region. Male and female mice exhibited diverse patterns in lung mRNA cytokine expression following WS exposure, with males showing downregulation and females displaying upregulation, notably for IL-1β, TNF-α, CXCL-1, CCL-5, TGF-β, and IL-6. After acute WS exposure, there were notable differences in the responses of macrophages, neutrophils, and bronchoalveolar lavage (BAL) cytokines IL-10, IL-6, IL-1β, and TNF-α. Significant diverse alterations were observed in BAL cytokines, specifically IL-1β, IL-10, IL-6, and TNF-α, as well as in the populations of immune cells, such as macrophages and polymorphonuclear leukocytes, in both Sham and OVX mice, following acute WS exposure. These findings elucidated the profound influence of hormonal changes on inflammatory outcomes, delineating substantial sex-related differences in immune activation and revealing altered immune responses in OVX mice due to ovarian hormone deficiency. In addition, the flow cytometry analysis highlighted the complex interaction between OVX surgery, acute WS exposure, and their collective impact on immune cell populations within the hematopoietic bone marrow niche. Conclusions: In summary, both male and female mice, alongside females subjected to OVX and those who had sham surgery, exhibit significant variations in the expression of proinflammatory cytokines, chemokines, lung mRNA gene expression, and related functional networks linked to signaling pathways. These differences potentially act as mediators of sex-specific and hormonal influences in the systemic inflammatory response to acute WS exposure during a wildfire event. Understanding the regulatory roles of genes expressed differentially under environmental stressors holds considerable implications, aiding in identifying sex-specific therapeutic targets for addressing acute lung inflammation and injury.
The objective of this project was to advance two key technological components—aeration control strategies and process design methodologies—to support the development and broader adoption of suboxic biological nitrogen removal (SBNR). The project focused on achieving the following three goals: • Enhance Model Predictive Control (MPC) Technology: Advance the DO/Nmaster MPC platform from its initial 2018 pilot deployment at the Chico Water Resource Recovery Facility in California to full-scale integration. This included partnering with a blower technology commercialization partner and incorporating machine learning (ML) capabilities to enable nationwide deployment. • Bridge Knowledge Gaps in SBNR Process Design: Address fundamental gaps in SBNR process understanding through controlled pilot-scale testing at a dedicated pilot facility. These efforts supported the development of robust kinetic models to inform reliable SBNR control, operational strategies, and design frameworks. • Demonstrate Full-Scale Implementation of Low DO/SBNR with ML: Transition low dissolved oxygen (DO)/SBNR coupled with ML from pilot-scale trials to full-scale demonstration in flow-through biological nutrient removal (BNR) systems, with the goal of enabling scalable, nationwide adoption in activated sludge treatment processes. The project included demonstration of SBNR at the pilot scale as performed by Hampton Roads Sanitation District (HRSD) and at the full-scale as performed by the Los Angeles County Sanitation Districts' (LACSD) Pomona Water Reclamation Plant (POWRP).
This presentation summarizes progress to date of the U.S. Department of Energy project, "Development of a computational framework for modeling golden eagles (Aquila chrysaetos) near wind farms," which focuses on stochastic behavioral modeling of soaring raptors across landscape, facility, and turbine spatiotemporal scales. This publicly available, open-source modeling framework includes behavioral models based on three different underlying principles: energy minimization at landscape scale, behavioral heuristics at landscape-facility scale, and data-driven behaviors at the facility-micro-scale. We will briefly overview the key advancements in the behavioral modeling state of the art, which leverages multiple high-resolution telemetry data sources combined with high-fidelity atmospheric flow modeling insights. We then present preliminary results from a validation study in Altamont, California. This new study involves a novel application of the Stochastic Soaring Raptor Simulator (SSRS), in a new geographic locale, to understand facility scale eagle movement patterns over time scales representative of a wind project's lifetime. For this desktop analysis (that does not depend on any high-performance computing resources), SSRS simultaneously considers a variety of wind conditions and eagle approach vectors toward a project site of interest. This work demonstrates the integration of publicly available landscape-scale atmospheric datasets, our recently improved engineering updraft models (see presentation from Thedin et al.), and our energy minimization behavioral models within the SSRS framework. While we only present results from a single behavioral model, the integration of these three modeling components forms the foundation for our more sophisticated behavioral models (see presentations from Brandes et al., Sandhu et al.) that are under active development. Results are presented in the form of presence maps, which may be applied to estimate risk to wildlife, augment ground survey data, inform wind-plant operations, or incorporated into wind-plant designs.
Here, this article presents a novel hierarchical speed planning framework for variable speed limits in mixed-autonomy traffic environments, leveraging server-side macroscopic control and vehicle-side microscopic execution. The framework integrates real-time traffic state estimation (TSE) and reinforcement learning (RL)-based control to mitigate congestion and improve traffic flow. A TSE enhancement module combines macroscopic data from sources like INRIX with high-resolution observations from connected autonomous vehicles (CAVs), enabling predictive modeling to address latency and noise. The target speed design module employs kernel smoothing and a buffer zone strategy to optimize traffic density and flow around bottlenecks. The proposed system was validated in the largest open-road test to date with 100 CAVs, demonstrating an overall 8% traffic density decrease, with a specific decrease of 7% upstream, 10% downstream, and a 52% decrease during the congestion formation phase at bottlenecks.
The IMMPE project, DE-FE0032284, was to enhance methane monitoring technologies and their applications across various natural gas asset classes. The scope included deploying advanced methane detection and monitoring technologies to identify and mitigate fugitive methane emissions, measuring emission rates, and assessing impacts. The findings included the successful mitigation of identified emissions and quantification of emission rates. A key outcome was the development of a comprehensive template and summary of recommendations for methane emissions monitoring, which is replicable for both upstream and downstream applications. Furthermore, the project emphasized the importance of education by providing training opportunities for technicians and regulators, thereby fostering awareness and promoting the adoption of cost-effective methane emissions monitoring and management techniques.
Here, to understand the system-level interactions between the entities in Carbon Capture, Utilization, and Storage (CCUS), an agent-based foundational modeling tool, CCUS-Agent, is developed for a large-scale study of transportation flows and infrastructure in the United States. Key features of the tool include (i) modular design, (ii) multiple transportation modes, (iii) capabilities for extension, and (iv) testing against various system components and networks of small and large sizes. Five matching algorithms for CO 2 supply agents (e.g., powerplants and industrial facilities) and demand agents (e.g., storage and utilization sites) are explored: Most Profitable First Year (MPFY), Most Profitable All Years (MPAY), Shortest Total Distance First Year (SDFY), Shortest Total Distance All Years (SDAY), and Shortest distance to long-haul transport All Years (ACAY). Before matching, the supply agent, demand agent, and route must be available, and the connection must be profitable. A profitable connection means the supply agent portion of revenue from the 45Q tax credit must cover the supply agent costs and all transportation costs, while the demand agent revenue portion must cover all demand agent costs. A case study employing over 5500 supply and demand agents and multimodal CCUS transportation infrastructure in the contiguous United States is conducted. The results suggest that it is possible to capture over 9 billion tonnes (GT) of CO 2 from 2025 to 2043, which will increase significantly to 22 GT if the capture costs are reduced by 40 %. The MPFY and SDFY algorithms capture more CO 2 earlier in the time horizon, while the MPAY and SDAY algorithms capture more later in the time horizon.
ABSTRACT Permafrost thaw represents one of Earth's largest climate feedback risks, potentially releasing vast carbon (C) stores as greenhouse gases (GHG). However, our ability to predict emissions remains limited by poor understanding of how changing organic matter (OM) composition affects microbial carbon processing. We test a metabolism‐centered redox framework, which views microbial processes as coupled oxidative‐reductive reactions, to mechanistically explain how organic matter metabolite quality controls greenhouse gas production in permafrost‐affected peatland ecosystems. Rather than relying solely on geochemical redox measurements, our approach examines how microbes balance electron flow through metabolic pathways. Using active layer peat (9–19 cm) from contrasting environments (bog and fen), we employed multi‐omics approaches, including metabolomics, metagenomics, and metatranscriptomics, to link OM chemistry to microbial function. Our results reveal distinct dissolved organic matter metabolite composition, with fen systems enriched in compounds with higher substrate quality (low molecular weight (MW) sugars with high H:C ratios and low aromaticity) and bog systems dominated by compounds with lower substrate quality (high MW phenols with lower H:C ratios and higher aromaticity). In fen samples, these sugar‐like compounds correlated with higher oxidative metabolism and methanogenesis, supported by increased glycolysis gene expression. Initially, electrons from increased oxidative metabolism were balanced through nitrate and sulfate reduction, but as these electron acceptors were depleted, methanogenesis increased to maintain redox balance. Fen samples showed rapid degradation of both high‐ and low‐substrate‐quality compounds, suggesting sufficient energy for efficient C cycling. Conversely, bog samples exhibited more polyphenolic compounds, lower glycolysis activity, and higher stress‐related gene expression, suggesting energy was diverted towards cell maintenance under acidic conditions rather than C processing. This approach suggests that predicting greenhouse gas emissions requires an understanding of how organic matter quality shapes microbial energy allocation strategies, providing a mechanistic framework for improving emission predictions from permafrost‐affected peatlands and similar ecosystems.
Approximately half of global energy consumption is used for heating and cooling. Because fossil fuels are used to meet most of this demand, heating and cooling of buildings produces a large portion of global greenhouse gas (GHG) emissions. The proposed project seeks to demonstrate the feasibility of a seasonal thermal energy storage concept called fracture thermal energy storage (FTES), which has the potential to dramatically lower energy requirements for heating and cooling and improve the resilience of building energy systems. FTES is a technique for building a highly efficient heat exchanger by creating a carefully designed set of fractures in the ground below a building. This heat exchanger allows thermal energy to be stored over seasonal timeframes—for example, hot thermal energy that is easily captured in the summer or energy from waste heat sources—to meet heating needs during colder months. FTES offers a solution with a relatively small footprint and lower cost compared to currently operating aquifer thermal energy storage (ATES) systems and could be used in the many areas without aquifers suitable for ATES. If commercialized, FTES systems could exceed the 2.5 TWh of energy storage per year from the more than 2,800 ATES systems in operation worldwide, which range from 0.1 MW to 30 MW. The savings in CO2 emissions per year are also expected to match or exceed individual ATES projects, with the largest, a 30 MW system used to provide heating and cooling to the University of Technology in Eindhoven in the Netherlands, estimated to save 13,000 tons of CO2 emissions per year. FTES utilizes mature drilling and fracturing technology and therefore has the potential to be rapidly commercialized once demonstrated. The ability to construct and establish flow through an FTES heat exchanger has been demonstrated by a previous project and the potential for efficient, large-capacity energy storage has been shown using numerical models. However, no experimental validation of these numerical estimates of thermal energy storage has been made. The first crucial need to advance FTES technology is to identify the sensitivity of key metrics such as thermal energy storage and production rates, capacities, and efficiencies to design parameters such as the number of fractures, depth/temperature of fractures, size of fractures, and circulation rates. The second crucial need is experimental testing of achievable thermal performance with optimized system design parameters. The proposed scope of work seeks to systematically address these two critical needs through a highly complementary international collaboration spanning theory, laboratory, and mesoscale field evaluation. The proposed work plan calls for using dimensional analysis and existing state-of-the-art numerical simulators to design carefully scaled laboratory and 10-meter-scale field tests of the thermal efficiency of FTES. The existing advanced laboratory and intermediate-scale field testbeds that will be used for this project will allow for detailed monitoring of the system performance during the test and of how the performance changes across time and length scales. These results will determine the feasibility of full- scale FTES systems. If the thermal performance is consistent with model predictions, the results will provide a strong economic justification for rapid commercialization of FTES technology in a wide range of geographical areas.
ABSTRACT: The ultimate aim of hydraulic fracturing is to have a long and conductive flow path that extends from the wellbore into the formation. The effective fracture length is part of a hydraulically propped fracture which contributes to production. The difficulty in achieving economical production targets from shale reservoirs is at the forefront in many exploration companies. Fracture conductivity loss is related to; proppant embedment under depletion, proppant crushing, damage as a result of fracturing fluid, fines migration and proppant-pack permeability-damage are some of the factors that contribute to production decline after hydraulic fracturing in shale reservoirs. The Caney Shale is a calcareous organic-rich mudrock. Various studies have investigated the effect that clay on shale well productivity, however, there is currently no literature on the Caney shale in relation to horizontal wells; all available literature exists in vertical wells as well as on formations of the Caney that are shallow in comparison to an emerging play which is twice the depth. In this paper we investigate stress-dependent fracture conductivity of proppant-filled fractures and proppant embedment in Caney shale through laboratory and modeling studies. API fracture conductivity tests were conducted using 2% KCl on five locations within the Caney shale that consisted of selecting three brittle(reservoir) zones and two ductile zones. Confining pressures range from 1,000 psi to 12,000 psi at 210°F. Conductivity, permeability as well as embedment were measured during the test. Our experimental results have confirmed that improved fracture conductivity is attributed to; proppant size, the increase in porosity of the proppant pack, closure pressure changes and the reduction in fracture conductivity are a function of many factors such as fracture closure stress. The findings from this study could help the stimulation design by providing new insights into the critical factors that are to be determined to facilitate the choice of proppants as well as fracturing fluids for long term production and recovery from shale reservoirs. 1 INTRODUCTION The development of low permeability formations, like shales, has been aided by hydraulic fracturing of horizontal wells (Radonjic et al., 2020). Hydraulic fracturing fluid is injected at a high pressure to induce tensile fractures that can link to and stimulate natural fractures (Katende et al., 2021a,b). Preserving adequate conductivity in hydraulic fractures over the life of the wells is required for economic production; nevertheless, conserving such conductivity can be difficult in some circumstances, particularly in soft, clay-rich formations (Wang et al., 2021). Proppant particles help to keep the fractures open when the pumping stops and the fracturing fluid returns to the wellbore, producing one or more propped hydraulic fractures of varying length, breadth, and height (Katende et al., 2021a). The proppant pack within the hydraulic fracture boosts well output by providing a greater permeability flowpath for hydrocarbons (Duenckel et al., 2016). Proppant in the fracture is under complicated stress conditions, and the interplay between the rock formation and the proppant pack has a significant impact on proppant-pack permeability (Karazincir et al., 2019). Proppant may be embedded (Katende et al., 2021a) in the rock or crushed into small pieces if the proppant size and strength characteristics are not specified appropriately, resulting in a loss in proppant-pack permeability and fracture aperture, and consequently a fall in well output.
The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.
The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.
There has been significant interest in the engineering of polymer topology to control rheology and mechanical stability in dilute solutions for applications involving extreme shear rate flows. However, methods to experimentally probe properties at relevant shear rates (≈ 10 4 –10 6 s –1 ) have remained ex situ, obscuring access to measures of polymer deformation and rheology that would otherwise provide mechanistic insight into the topology-dependent properties that control their behavior in extreme shear flows. In this study, we used novel in situ small angle neutron scattering measurements in a capillary rheometer (capillary rheo-SANS) to simultaneously measure solution viscosities and polymer deformations in high shear on a series of chemically homologous topology-defined polymers including linear, randomly branched, and star-shaped molecules. We demonstrate that differences in the onset of chain stretching and shear thinning of these polymers in dilute solution are controlled primarily by differences in their molecular relaxation time. These differences correlate with differences in chain scission inferred from ex situ measurements at more extreme shear rates. Together, the results demonstrate a direct coupling between chain deformation and scission, and suggest that the dominant effect of branching as a means to impart resilience against mechanical degradation is through differences in relaxation dynamics due to branching. We anticipate that these results will provide key insights to engineer topology-controlled polymers for rheological modification, mechanical stability, and controlled mechano-chemistry.
Electrifying heavy-duty trucks reduces on-road diesel emissions but shifts the burden of supplying energy to power-generation facilities. The combined effect of Inflation Reduction Act investments in grid decarbonization and truck electrification will alter the magnitude and distribution of air pollution burdens across the United States. These investments are intended to facilitate a just energy transition, with 40% of the benefits flowing to disadvantaged communities per the Justice40 Initiative. Here we evaluate the combined effects of Inflation Reduction Act grid decarbonization and truck electrification investments on a national scale to determine whether the air pollution benefits would meet this 40% goal for both disadvantaged communities and the most exposed racial–ethnic groups. We find that truck electrification and decarbonization reduce air-pollution-related premature mortality in disadvantaged communities. However, the relative disparity between disadvantaged and non-disadvantaged communities increases, suggesting that a disproportionate share of benefits accrue to non-disadvantaged communities. Whereas absolute disparity in grid emissions decreases over time for all racial–ethnic groups, relative disparity remains largely unchanged, with Black populations being the most exposed. Electrifying drayage corridors would result in comparatively large health benefits for disadvantaged communities, suggesting that increasing targeted electrification investments in short-haul routes near urban areas (for example, ports) could be promising.
This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.
This paper presents, to our knowledge, the first system-level engineering study to bio-mimic the cybernetics and flow dynamics of energy resources in natural ecosystems for the control of heterogeneous energy infrastructures in the built environment. To this end, we introduce a novel Biomimetic Pulsing State (BPS) control that functionally mimics mature ecosystems. A preliminary Modelica-based case study features a single-family residential building with electrical and HVAC subsystems. The BPS control objective is to minimize the energy exchange between the building and the grid for the purposes of future self-supporting buildings and grid stability. The building contains PV, a wind turbine, a battery storage system, and a fan coil/heat pump HVAC system served by an ambient district energy network. Evaluating the control performance (BPS vs. constant setpoint) over several renewable energy scenarios (net importer, net zero, net exporter), simulation results show how the building's HVAC system can dynamically adjust its electrical load and temperatures to the electrical system's net energy status in real-time with BPS control. As a net importer, the heat pump consumed 29% less energy and its peak power reduced by 15% with BPS control compared to the constant setpoint case, with the zone air temperature 1 degree C lower on average. As a net exporter, the heat pump effectively consumed the same energy, but the peak power increased by 34% with BPS control, while the zone air temperature was 1 degree C higher when renewable energy was abundant, preheating the home. BPS and constant setpoint control produced comparable results under a net zero scenario. While further evaluation is essential, BPS control may help communities meet their sustainability and resiliency targets as they transition towards fully distributed and renewable energy grids.