Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fire effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Forest fire advanced system technology (FFAST) conceptual design study

The National Aeronautics and Space Administration's Jet Propulsion Laboratory (JPL) and the U.S. Department of Agriculture (USDA) Forest Service completed a conceptual design study that defined an integrated forest fire detection and mapping system that will be based upon technology available in the 1990s. Potential system configuration options in emerging and advanced technologies related to the conceptual design were identified and recommended for inclusion as preferred system components. System component technologies identified for an end-to-end system include airborne mounted, thermal infrared (IR) linear array detectors, automatic onboard georeferencing and signal processing, geosynchronous satellite communications links, and advanced data integration and display. Potential system configuration options were developed and examined for possible inclusion in the preferred system configuration. The preferred system configuration will provide increased performance and be cost effective over the system currently in use. Forest fire management user requirements and the system component emerging technologies were the basis for the system configuration design. The conceptual design study defined the preferred system configuration that warrants continued refinement and development, examined economic aspects of the current and preferred system, and provided preliminary cost estimates for follow-on system prototype development.

Nichols, J. David↗

High Pressure Fire Loop Analysis

The scope will be limited to analyzing the effect of the EFC within the system and how one improperly installed coupling affects the rest of the HPFL system. The discussion will include normal operations, impaired flow, and service interruptions. Normal operations are defined as two-way flow to buildings. Impaired operations are defined as a building that only has one-way flow being provided to the building. Service interruptions will be when a building does not have water available to it. The project will look at the following aspects of the reliability of the HPFL system: mean time to failure (MTTF) of EFCs, mean time between failures (MTBF), series system models, and parallel system models. These calculations will then be used to discuss the reliability of the system when one of the couplings fails. Compare the reliability of two-way feeds versus one-way feeds.

42 ENGINEERING↗

Applications of advanced V/STOL aircraft concepts to civil utility missions, volume 1

The suitability of advanced V/STOL aircraft to civil utility applications was assessed for offshore oil support, forest fire support, transport, and humanitarian missions. The aircraft concepts considered were a lift fan aircraft, a tilt rotor aircraft, and an advanced helicopter. All the aircraft had a design payload of 2,268 kg. (5,000 lb.) with the maximum range varying from 2,224 km. (1,800 nm) for the lift fan STOL to 1,482 km (800 nm) for the advanced helicopter. The analysis of these missions considered such factors as aircraft performance, annual utilization, initial cost, and operating cost. It is concluded that all the advanced V/STOL aircraft concepts generally performed these missions better than contemporary aircraft. The lift fan aircraft and the tilt rotor aircraft were found to be effective for the offshore oil and the forest fire support missions. The lift fan aircraft in the VTOL mode was also found to be very attractive for the executive transport mission where the passenger time value was $30/hr. or more.

Source record↗

Ensemble PM2.5 Forecasting during the 2018 Camp Fire Event Using the HYSPLIT Transport and Dispersion Model

Biomass burning releases a vast amount of aerosols into the atmosphere, often leading to severe air quality and health problems. Prediction of the air quality effects from biomass burning emissions is challenging due to uncertainties in fire emission, plume rise calculation, and other model inputs/processes. Ensemble forecasting is increasingly used to represent model uncertainties. In this paper, an ensemble forecast was conducted to predict surface PM2.5 during the 2018 California Camp Fire event using the NOAA HYSPLIT dispersion model at 0.1- degree horizontal resolution. Different combinations of four satellite-based fire emission datasets (FEER, FLAMBE, GBBEPx and GFAS), two plume rise schemes (Briggs and Sofiev), various meteorology inputs and model setup options were used to create the forecast ensemble, for a total of 112 experiments. The performance of each ensemble member and the ensemble mean were evaluated using ground-based observations, with four statistical metrics and an overall rank. The ensemble spread of the 112 members reached 1000 μg/m3, highlighting the large uncertainty in wildfire forecast. The ensemble mean displayed the best performance. Each fire emission product contributed to one or more members among the top ten performers, revealing the forecasting dependence on both the quality of fire emissions data and model representation of emission, transport and removal processes. In addition, an ensemble size reduction technique was introduced. With the help of this technique, the ensemble size was reduced from 112 to 28 members and still produced an ensemble mean that yielded comparable or even better performance to that of the full ensemble.

Biomass Burning↗

Design Guidelines for Shielding Effectiveness, Current Carrying Capability, and the Enhancement of Conductivity of Composite Materials

These guidelines address the electrical properties of composite materials which may have an effect on electromagnetic compatibility (EMC). The main topics of the guidelines include the electrical shielding, fault current return, and lightning protection capabilities of graphite reinforced polymers, since they are somewhat conductive but may require enhancement to be adequate for EMC purposes. Shielding effectiveness depends heavily upon the conductivity of the material. Graphite epoxy can provide useful shielding against RF signals, but it is approximately 1,000 times more resistive than good conductive metals. The reduced shielding effectiveness is significant but is still useful in many cases. The primary concern is with gaps and seams in the material just as it is with metal. Current carrying capability of graphite epoxy is adequate for dissipation static charges, but fault currents through graphite epoxy may cause fire at the shorting contact and at joints. The effect of lightning on selected graphite epoxy material and mating surfaces is described, and protection methods are reviewed.

Evans, R. W.↗

Fire, insect and disease‐caused tree mortalities increased in forests of greater structural diversity during drought

Abstract Structural diversity is an emerging dimension of biodiversity that accounts for size variations in organs among individuals in a community. Previous studies show significant effects of structural diversity on forest growth, but its effects on forest mortality are not known, particularly at a large scale. To address this knowledge gap, we quantified structural diversity using stem structural diversity (SSD) based on both tree diameter and height. We obtained U.S. Forest Service Forest Inventory and Analysis (FIA) data from over 2400 plots across southcentral U.S. forests that have suffered a recent drought. Using data from multiple sampling times, we calculated SSD and compared the relative importance of SSD, species diversity, functional diversity and other stand attributes in determining tree mortalities caused by fire, insects and diseases. We also used FIRETEC, a physics‐based fire model, to test the effect of SSD on canopy consumption by fire. Our results showed that (1) SSD was positively associated with tree mortalities caused by all three disturbances; (2) species richness was negatively associated with insect‐ and disease‐caused mortalities; (3) functional diversity was negatively associated with fire‐ and disease‐caused mortalities and (4) more phylogenetically related species had more similar mortality rates by insect and disease but not fire. Moreover, the FIRETEC model showed increasing canopy consumption by fire in stands with greater SSD. Together, the different tree mortalities during drought associated with SSD more consistently than the other biodiversity metrics were evaluated. Synthesis . Our results suggest that SSD could be considered in modelling forest dynamics and planning management to sustain forest health under disturbances.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity of Mesoscale Modeling of Smoke Direct Radiative Effect to the Emission Inventory: a Case Study in Northern Sub-Saharan African Region

An ensemble approach is used to examine the sensitivity of smoke loading and smoke direct radiative effect in the atmosphere to uncertainties in smoke emission estimates. Seven different fire emission inventories are applied independently to WRF-Chem model (v3.5) with the same model configuration (excluding dust and other emission sources) over the northern sub-Saharan African (NSSA) biomass-burning region. Results for November and February 2010 are analyzed, respectively representing the start and end of the biomass burning season in the study region. For February 2010, estimates of total smoke emission vary by a factor of 12, but only differences by factors of 7 or less are found in the simulated regional (15degW-42degE, 13degS-17degN) and monthly averages of column PM(sub 2.5) loading, surface PM(sub 2.5) concentration, aerosol optical depth (AOD), smoke radiative forcing at the top-of-atmosphere and at the surface, and air temperature at 2 m and at 700 hPa. The smaller differences in these simulated variables may reflect the atmospheric diffusion and deposition effects to dampen the large difference in smoke emissions that are highly concentrated in areas much smaller than the regional domain of the study. Indeed, at the local scale, large differences (up to a factor of 33) persist in simulated smoke-related variables and radiative effects including semi-direct effect. Similar results are also found for November 2010, despite differences in meteorology and fire activity. Hence, biomass burning emission uncertainties have a large influence on the reliability of model simulations of atmospheric aerosol loading, transport, and radiative impacts, and this influence is largest at local and hourly-to-daily scales. Accurate quantification of smoke effects on regional climate and air quality requires further reduction of emission uncertainties, particularly for regions of high fire concentrations such as NSSA.

Sahel and sub-Saharan African region↗

Cutting planes for the multistage stochastic unit commitment problem

As renewable energy penetration rates continue to increase in power systems worldwide, new challenges arise for system operators in both regulated and deregulated electricity markets to solve the security-constrained coal-fired unit commitment problem with intermittent generation (due to renewables) and uncertain load, in order to ensure system reliability and maintain cost effectiveness. In this paper, we study a security-constrained coal-fired stochastic unit commitment model, which we use to enhance the reliability unit commitment process for day-ahead power system operations. In our approach, we first develop a deterministic equivalent formulation for the problem, which leads to a large-scale mixed-integer linear program. Then, we verify that the turn on/off inequalities provide a convex hull representation of the minimum-up/down time polytope under the stochastic setting. Next, we develop several families of strong valid inequalities mainly through lifting schemes. In particular, by exploring sequence independent lifting and subadditive approximation lifting properties for the lifting schemes, we obtain strong valid inequalities for the ramping and general load balance polytopes. Lastly, branch-and-cut algorithms are developed to employ these valid inequalities as cutting planes to solve the problem. Our computational results verify the effectiveness of the proposed approach.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effects of Slag Ejection on Solid Rocket Motor Performance

In past firings of the Reusable Solid Rocket Motor (RSRM) both static test and flight motors have shown small pressure perturbations occurring primarily between 65 and 80 seconds. A joint NASA/Thiokol team investigation concluded that the cause of the pressure perturbations was the periodic ingestion and ejection of molten aluminum oxide slag from the cavity around the submerged nozzle nose which tends to trap and collect individual aluminum oxide droplets from the approach flow. The conclusions of the team were supported by numerous data and observations from special tests including high speed photographic films, real time radiography, plume calorimeters, accelerometers, strain gauges, nozzle TVC system force gauges, and motor pressure and thrust data. A simplistic slag ballistics model was formulated to relate a given pressure perturbation to a required slag quantity. Also, a cold flow model using air and water was developed to provide data on the relationship between the slag flow rate and the chamber pressure increase. Both the motor and the cold flow model exhibited low frequency oscillations in conjunction with periods of slag ejection. Motor and model frequencies were related to scaling parameters. The data indicate that there is a periodicity to the slag entrainment and ejection phenomena which is possibly related to organized oscillations from instabilities in the dividing streamline shear layer which impinges on the underneath surface of the nozzle.

Whitesides, R. Harold↗

Biomass burning aerosol radiative effects in the Southeast Atlantic depend strongly on meteorological forcing method

Biomass burning aerosols (BBAs) from African fires may strongly impact Earth’s radiation budget in the southeast Atlantic (SEA), but the sign and magnitude of the overall radiative effect (RE) remain uncertain. Aerosol–climate models are needed to separately quantify direct, indirect, and semi-direct REs. Here, we evaluate improved simulations with the UK Met Office's Unified Model and explore REs resulting from various methods used to match observed meteorology (nudging or running forecasts reinitialized at different frequencies). REs are calculated as differences in radiative fluxes between simulations with and without smoke emissions and with and without aerosol absorption. All model setups agree on net warming for the SEA dominated by the direct effect. Simulated smoke, clouds, and the direct effect agree better with observations than previous studies using the same model, though biases in aerosol extinction and liquid water path remain. Changes in cloud droplet number concentration due to BBA self-lofting influence how cleanly we can separate cloud effects into semi-direct and indirect effects. Total RE, which remains unaffected, ranges from +3.0 to +7.9 W m −2 . The 4.9 W m −2 spread arises mainly from simulated semi-direct effects. Forecasts three days long or less probably do not allow time for plausible differences in boundary layer properties due to semi-direct effects to accumulate. Free running simulations with and without smoke accumulate differences in meteorology that are likely spurious “butterfly effects”. We recommend future research quantifying BBA REs over weeks to months to use meteorological forcing techniques that allow aerosol absorption to affect the boundary layer.

Giuffrida, Eric [Carnegie Mellon University, Pitts↗

Convolutional Non-Homogeneous Poisson Process and its Application to Wildfire Ignition Risk Quantification for Power Delivery Networks

To quantify wildfire ignition risks on power delivery networks, the current practice predominantly relies on the empirically calculated fire danger indices, which may not well capture the effects of dynamically changing environmental factors. This article proposes a spatio-temporal point process model, known as the Convolutional Non-homogeneous Poisson Process (cNHPP), and applies the model to quantify wildfire ignition risks for power delivery networks. The proposed model captures both the current (i.e., instantaneous) and cumulative (i.e., historical) effects of key environmental processes (i.e., covariates) on wildfire risks, as well as the spatio-temporal dependency among different segments of the power delivery network. The computation and interpretation of the intensity function are thoroughly investigated. We apply the proposed approach to estimate wildfire ignition risks on major transmission lines in California, using historical fire data, meteorological and vegetation data obtained from the National Oceanic and Atmospheric Administration and National Aeronautics and Space Administration. Here, a comprehensive comparison study is performed to show the applicability and predictive capability of the proposed approach.

Non-homogeneous Poisson Process↗

Development of a Nitrogen and Magnesium Oxide based Class A, B & D Suffocating Fire System (SFSS) for Gloveboxes

Testing related to the development and performance of a “Proof of Concept” Nitrogen/Magnesium Oxide Suffocating Fire System (SFSS) was conducted at Fire and Pump Service Group (FPSG) located in Rancho Dominguez, California. The SFSS Engineering Team (SFSSET), consisting of FPSG and Los Alamos National Laboratory (LANL) personnel researched, developed a prototype, and conducted testing to determine effective means to deliver magnesium oxide (MgO) sand into a glovebox (GB) in a class D fire event. The prototypes development also established the effective coverage area of a magnesium oxide suppression system as well as demonstrated that the GB inert atmosphere could be maintained during and after the release of the MgO sand to control Class A, B and D fires. Previous testing conducted on nitrogen based SFSS provided evidence that the nitrogen based SFSS controlled Class A and B fires (Ralph Clayton, Los Alamos National Laboratory, Brandon Troc and Frank Broidy, Fire and Pump Service Group 2020).Final testing was conducted within a mock GB capable of simulating an inert glovebox atmosphere. Testing demonstrated that the inert atmosphere can be maintained during and after discharge of the MgO sand over a coverage area.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Synergy between land use and climate change increases future fire risk in Amazon forests

Tropical forests have been a permanent feature of the Amazon basin for at least 55 million years, yet climate change and land use threaten the forest's future over the next century. Understory forest fires, which are common under the current climate in frontier forests, may accelerate Amazon forest losses from climate-driven dieback and deforestation. Far from land use frontiers, scarce fire ignitions and high moisture levels preclude significant burning, yet projected climate and land use changes may increase fire activity in these remote regions. Here, we used a fire model specifically parameterized for Amazon understory fires to examine the interactions between anthropogenic activities and climate under current and projected conditions. In a scenario of low mitigation efforts with substantial land use expansion and climate change – Representative Concentration Pathway (RCP) 8.5 – projected understory fires increase in frequency and duration, burning 4–28 times more forest in 2080–2100 than during 1990–2010. In contrast, active climate mitigation and land use contraction in RCP4.5 constrain the projected increase in fire activity to 0.9–5.4 times contemporary burned area. Importantly, if climate mitigation is not successful, land use contraction alone is very effective under low to moderate climate change, but does little to reduce fire activity under the most severe climate projections. These results underscore the potential for a fire-driven transformation of Amazon forests if recent regional policies for forest conservation are not paired with global efforts to mitigate climate change.

54 ENVIRONMENTAL SCIENCES↗

Synergy Between Land Use and Climate Change Increases Future Fire Risk in Amazon Forests

Tropical forests have been a permanent feature of the Amazon basin for at least 55 million years, yet climate change and land use threaten the forest's future over the next century. Understory forest fires, which are common under the current climate in frontier forests, may accelerate Amazon forest losses from climate-driven dieback and deforestation. Far from land use frontiers, scarce fire ignitions and high moisture levels preclude significant burning, yet projected climate and land use changes may increase fire activity in these remote regions. Here, we used a fire model specifically parameterized for Amazon understory fires to examine the interactions between anthropogenic activities and climate under current and projected conditions. In a scenario of low mitigation efforts with substantial land use expansion and climate change – Representative Concentration Pathway (RCP) 8.5 – projected understory fires increase in frequency and duration, burning 4–28 times more forest in 2080–2100 than during 1990–2010. In contrast, active climate mitigation and land use contraction in RCP4.5 constrain the projected increase in fire activity to 0.9–5.4 times contemporary burned area. Importantly, if climate mitigation is not successful, land use contraction alone is very effective under low to moderate climate change, but does little to reduce fire activity under the most severe climate projections. These results underscore the potential for a fire-driven transformation of Amazon forests if recent regional policies for forest conservation are not paired with global efforts to mitigate climate change.

Le Page, Yannick↗

Communications System Concept of Operations (ConOp) for Supporting Second Shift (SS) Operations

Wildland fires take place most often in remote areas without access to communications infrastructure. Communication during wildfire operations is crucial for safe and effective command and control of air assets, ground-based firefighters, and fire management. Without connectivity, Incident Command (IC) cannot exchange information, receive alerts or work with all parties involved in the wildfire suppression operation. Current policy directs IC to use voice radio communications, which require no prior infrastructure, to provide information needed for the command, control and safety of personnel and resources. Cellular communications are used only for logistical purposes unless no other method is available. To address some of the shortcomings of the current state of communications, the Advanced Capabilities for Emergency Response Operations (ACERO) Second Shift (SS) technical team is developing characteristics of an air-to-ground Mesh Radio System (MRS) and preparing for a future demonstration. The MRS will allow air and ground assets to automatically join a radio network without relying on existing infrastructure and exchange information critical to maintaining situation awareness and air traffic management by the onsite IC. The MRS will also give users more options for communications in addition to voice communications.

David Fuller↗

Preliminary analytical results using surface current integration for predicting effects of surface pillows on RF performance

An overview of the fast integral RF evaluation (FIRE) program is presented. This program uses surface current integration to evaluate RF performance of antenna systems. It requires modeling of surfaces in X, Y, Z coordinates along equally spaced X and Y grids with Z in the focal directon. The far field contribution of each surface point includes the effects of the Z-component of surface current which is not included in the aperture integration technique. Because of this, surface current integration is the most effective and inclusive technique for predicting RF performance on non-ideal reflectors. Results obtained from use of the FIRE program and an aperture integration program to predict RF performance of a LSS antenna concept are presented.

Farrell, C. E.↗

Superheater Corrosion In Biomass Boilers: Today's Science and Technology

This report broadens a previous review of published literature on corrosion of recovery boiler superheater tube materials to consider the performance of candidate materials at temperatures near the deposit melting temperature in advanced boilers firing coal, wood-based fuels, and waste materials as well as in gas turbine environments. Discussions of corrosion mechanisms focus on the reactions in fly ash deposits and combustion gases that can give corrosive materials access to the surface of a superheater tube. Setting the steam temperature of a biomass boiler is a compromise between wasting fuel energy, risking pluggage that will shut the unit down, and creating conditions that will cause rapid corrosion on the superheater tubes and replacement expenses. The most important corrosive species in biomass superheater corrosion are chlorine compounds and the most corrosion resistant alloys are typically FeCrNi alloys containing 20-28% Cr. Although most of these materials contain many other additional additions, there is no coherent theory of the alloying required to resist the combination of high temperature salt deposits and flue gases that are found in biomass boiler superheaters that may cause degradation of superheater tubes. After depletion of chromium by chromate formation or chromic acid volatilization exceeds a critical amount, the protective scale gives way to a thick layer of Fe 2 O 3 over an unprotective (FeCrNi) 3 O 4 spinel. This oxide is not protective and can be penetrated by chlorine species that cause further acceleration of the corrosion rate by a mechanism called active oxidation. Active oxidation, cited as the cause of most biomass superheater corrosion under chloride ash deposits, does not occur in the absence of these alkali salts when the chloride is present as HCl gas. Although a deposit is more corrosive at temperatures where it is molten than at temperatures where it is frozen, increasing superheater tube temperatures through the measured first melting point of fly ash deposits does not necessarily produce a step increase in corrosion rate. Corrosion rate typically accelerates at temperatures below the first melting temperature and mixed deposits may have a broad melting temperature range. Although the environment at a superheater tube surface is initially that of the ash deposits, this chemistry typically changes as the deposits mature. The corrosion rate is controlled by the environment and temperature at the tube surface, which can only be measured indirectly. Some results are counter-intuitive. Two boiler manufacturers and a consortium have developed models to predict fouling and corrosion in biomass boilers in order to specify tube materials for particular operating conditions. It would be very useful to compare the predictions of these models regarding corrosion rates and recommended alloys in the boiler environments where field tests will be performed in the current program. Manufacturers of biomass boilers have concluded that it is more cost-effective to restrict steam temperatures, to co-fire biofuels with high sulfur fuels and/or to use fuel additives rather than try to increase fuel efficiency by operating with superheater tube temperatures above melting temperature of fly ash deposits. Similar strategies have been developed for coal fired and waste-fired boilers. Additives are primarily used to replace alkali metal chloride deposits with higher melting temperature and less corrosive alkali metal sulfate or alkali aluminum silicate deposits. Design modifications that have been shown to control superheater corrosion include adding a radiant pass (empty chamber) between the furnace and the superheater, installing cool tubes immediately upstream of the superheater to trap high chloride deposits, designing superheater banks for quick replacement, using an external superheater that burns a less corrosive biomass fuel, moving circulating fluidized bed (CFB) superheaters from the convective pass into the hot recirculated fluidizing medium and adding an insulating layer to superheater tubes to raise their surface temperature above the dew point temperature of alkali chlorides. These design changes offer advantages but introduce other challenges. For example, operating with superheater temperatures above the dew point of alkali chlorides could require the use of creep-resistant tube alloys and doesn't eliminate chloride corrosion. Improved test methods that can be applied within this project include automated dimensional metrology to make a statistical analysis of depth of penetration and corrosion product thickness, and simultaneous thermal analysis measurements to quantify the melting of complex ashes and avoid the unreliability of the standard ash fusion test. Other important developments in testing include the installation of individually-temperature-controlled superheater loops for corrosion testing in operating boilers and temperature gradient testing.

09 BIOMASS FUELS↗

Ammonia and nitric acid emissions from wetlands and boreal forest fires

Tests conducted during three (one boreal and two wetland) ecosystem fires have established the NH3- and HNO3-determination effectiveness of the 'tungsten oxide denuder' technique, using a low-flying helicopter to fly through biomass-burn smoke plumes. Both species were found to be present in the smoke plumes at levels much higher than background. Despite the differences between boreal and wetland ecosystems, HNO3 emissions were comparable; NH3 emissions, by contrast, were 5-8 times greater in the boreal fire than in the wetland fires. Biomass burning is found to make a significant role in the tropospheric ammonia budget.

Lebel, Peter J.↗