Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Advanced Anion Exchange Membranes with Tunable Water Transport for PGM-Free AEMFCs

This project advanced the synthesis, characterization, and testing of anion exchange membranes for use in fuel cells. Our goal was to improve the water transport in anion exchange membrane fuel cells to improve their performance and durability. Through the work in this project we: 1) developed new composite anion exchange membranes through polymer synthesis and membrane casting into mechanical supports; 2) optimized electrode architecture and cell conditions to achieve; 3) demonstrated an integrated approach to achieving over 1 W/cm 2 in an operating device. While we did not achieve 1000 hours of continuous operation, we demonstrated multiple runs of more than 300 hours of device performance at steady-state.

08 HYDROGEN↗

Joining Study for Formed Plate Heat Exchangers (Final Report)

Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.

36 MATERIALS SCIENCE↗

Al-Ce Alloy-Based Compact Heat Exchanger for Refrigerant Charge Reduction and Unprecedented Durability

• Oak Ridge National Laboratory and Eck Industries produced and characterized durable and corrosion resistant Al-Ce-Mg alloy-based heat exchanger. • Eck Industries successfully casted Al-Ce-Mg heat exchanger. • ORNL characterized reaction bonding between Al-2Ce-6Mg alloy and stainless-steel tube in a heat exchanger header. • Metallurgical bonds were achieved between stainless steel tubes and Al-Ce-Mg alloy cast headers. • ORNL performed corrosion testing on Al-Ce-Mg alloy/stainless steel tube reactive bond interface. • In most cases no significant changes to the reactive bond morphology or compositional distribution were observed in the samples after exposure to acid for 267h acid.

36 MATERIALS SCIENCE↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Considerations for Phase Change Material-Incorporated Heat Exchangers in Water Heating

In recent years, the buildings sector has seen major pushes towards decarbonization through innovations that promote deep electrification. 20% of an average household's energy use comes from water heating, and in the US, over half of all households still use gas water heaters. Of those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. However, HPWHs tend to have larger dimensions, preventing current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). This study outlines the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. To ensure optimal PCM utilization and tank storage capacity, this works seeks to co-maximize surface area and PCM volume; therefore, this research targets triply periodic minimal surface (TPMS) lattices, which boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives. Our current results indicate that tuning lattice properties can effectively produce geometries that provide enough energy storage to achieve a 50-gallon capacity out of a 40-gallon HPWH, even when placing the PCM heat exchanger inside the tank. Additionally, we demonstrate successful fabrication of lattices with these tuned properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Technical Report for U.S.-Japan Hadronic Physics Exchange Program for Studies of Hadron Structure and QCD

Nuclear physics explores the fundamental properties of matter -- how protons and neutrons emerge as quantum systems of elementary particles, how they form the atomic nuclei, and how they give rise to the wide variety of phenomena and applications at biological, technical, and astronomical scales. It is a global scientific effort centered around large-scale experimental user facilities (particle accelerators and detectors), advanced theoretical methods and concepts, and computational techniques and resources. Exchange of knowledge and ideas, scientific collaboration, and workforce development on a global scale are essential for the future of the field. The nuclear physics program envisaged in the 2023 DOE/NSF NSAC Long-Range Plan and pursued at the U.S. National Labs has strong synergies with programs at other facilities worldwide and will realize significant benefits from international collaboration. Nuclear physics is also recognized for promoting international cooperation in the broadest sense through joint construction and operation of experimental equipment, personal contacts between scientists, and education and training. The U.S.-Japan Hadronic Physics Exchange Program (USJPHE) supported collaborative scientific research in hadronic physics and quantum chromodynamics. USJHPE focused on subject areas related to the programs at current and future experimental facilities in the U.S.\ and Japan and supported both experimental and theoretical studies. USJHPE particularly aimed to realize synergies between the hadronic physics programs at Jefferson Lab 12 GeV and J-PARC resulting from the complementarity of electromagnetic and hadronic probes in the multi-GeV energy range. Subject areas of common interest included the quark-gluon structure of hadrons and nuclei, meson and baryon spectroscopy, strangeness and hypernuclear physics, and other related topics. USJHPE also supported research in hadronic physics and nuclear-physics-enabled tests of fundamental symmetries related to the programs at Brookhaven National Lab, Fermilab, KEK, Spring-8, and university-based facilities in the U.S. and Japan. USJHPE especially promoted collaboration between the U.S. and Japanese nuclear physics communities in developing the physics program and instrumentation for the future Electron-Ion Collider. USJHPE was intended to provide travel grants to U.S.-based scientists (primary institutional affiliation with a U.S.\ university, national laboratory, or other research center) to visit Japanese institutions and conduct collaborative research there. The program supported senior researchers, postdoctoral fellows, and students. Continuing the setup of the preceding grant period, J-PARC served as the Japanese “hub” for U.S. physicists for short- and long-term visits, and JLab served as the corresponding U.S. “hub”. The program was officially managed through the U. of Connecticut in Storrs, CT. Support for Japanese physicists visiting the U.S. was provided through funds from Japanese funding agencies. The USJHPE program promoted the scientific exchange and the collaborative spirit in hadronic physics between the two countries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ground heat exchanger design tool with rowwise placement of boreholes

Simulation-based design tools have been used since the late 1980s for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems. The ground heat exchanger simulations used in these tools rely on thermal response functions known as g-functions. Because of the significant computational burden in computing g-functions for even a single configuration, the design tools have relied on libraries of pre-computed g-functions. These g-functions were available for standard configuration shapes, such as lines, rectangles, open rectangles, L-shapes, and U-shapes. Standard shapes are often sub-optimal. For any building on a site, the available land may preclude use of a standard shape. For large GSHP systems with significantly imbalanced annual heat rejection and extraction loads, large rectangular fields may experience significant heat build-up (or heat draw-down) in the interior of the field. This paper describes a new ground heat exchanger design tool capable of automatically selecting and sizing both standard and irregular configurations. The focus of this paper is a method for creating, selecting and sizing irregular configurations where the available land area and "no-go" zones are described as irregular polygons.

Spitler, Jeffery↗

On the Representation of Hyporheic Exchange in Models for Reactive Transport in Stream and River Corridors

Efforts to include more detailed representations of biogeochemical processes in basin-scale water quality simulation tools face the challenge of how to tractably represent mass exchange between the flowing channels of streams and rivers and biogeochemical hotspots in the hyporheic zones. Multiscale models that use relatively coarse representations of the channel network with subgrid models for mass exchange and reactions in the hyporheic zone have started to emerge to address that challenge. Two such multiscale models are considered here, one based on a stochastic Lagrangian travel time representation of advective pumping and one on multirate diffusive exchange. The two models are formally equivalent to well-established integrodifferential representations for transport of non-reacting tracers in steady stream flow, which have been very successful in reproducing stream tracer tests. Despite that equivalence, the two models are based on very different model structures and produce significantly different results in reactive transport. In a simple denitrification example, denitrification is two to three times greater for the advection-based model because the multirate diffusive model has direct connections between the stream channel and transient storage zones and an assumption of mixing in the transient storage zones that prevent oxygen levels from dropping to the point where denitrification can progress uninhibited. By contrast, the advection-based model produces distinct redox zonation, allowing for denitrification to proceed uninhibited on part of the hyporheic flowpaths. These results demonstrate that conservative tracer tests alone are inadequate for constraining representation of mass transfer in models for reactive transport in streams and rivers.

54 ENVIRONMENTAL SCIENCES↗

Numerical and Experimental Study of a Novel Additively Manufactured Metal-Polymer Composite Heat-Exchanger for Liquid Cooling Electronics

In order to meet increasing power-dissipation requirements of the electronics industry, compact, low-cost, and lightweight heat exchangers (HXs) are desired. With proper design, materials, and manufacture, polymer composite heat exchangers could meet these requirements. This paper presents a novel crossflow air-to-water, low-cost, and lightweight metal-polymer composite HX. This HX, which is entirely additively manufactured, utilizes a novel cross-media approach that provides direct heat exchange between air and liquid sides by using connecting fins. A robust numerical model was developed, which includes the dimensional effects of additive manufacturing. The study consists of a simplified 3D CFD model based on ellipsoidal-shaped staggered tube banks for the laminar range. It then uses an analytical approach to compute entire HX performance. The model is validated experimentally within 8% for thermal performance, 12% for air-side impedance, and 18% for water-side impedance. Finally, HX is compared with a conventional CPU radiator and performs within 10% of the conventional unit for reasonable flow rates and pressure-drop ranges. Moreover, HX also provides added design and cost advantages over the conventional unit, which makes the HX a potential candidate for electronic cooling applications.

30 DIRECT ENERGY CONVERSION↗

Consistent responses of vegetation gas exchange to elevated atmospheric CO 2 emerge from heuristic and optimization models

Elevated atmospheric CO 2 concentration is expected to increase leaf CO 2 assimilation rates, thus promoting plant growth and increasing leaf area. It also decreases stomatal conductance, allowing water savings, which have been hypothesized to drive large-scale greening, in particular in arid and semiarid climates. However, the increase in leaf area could reduce the benefits of elevated CO 2 concentration through soil water depletion. The net effect of elevated CO 2 on leaf- and canopy-level gas exchange remains uncertain. To address this question, we compare the outcomes of a heuristic model based on the Partitioning of Equilibrium Transpiration and Assimilation (PETA) hypothesis and three model variants based on stomatal optimization theory. Predicted relative changes in leaf- and canopy-level gas exchange rates are used as a metric of plant responses to changes in atmospheric CO 2 concentration. Both model approaches predict reductions in leaf-level transpiration rate due to decreased stomatal conductance under elevated CO 2 , but negligible (PETA) or no (optimization) changes in canopy-level transpiration due to the compensatory effect of increased leaf area. Leaf- and canopy-level CO 2 assimilation is predicted to increase, with an amplification of the CO 2 fertilization effect at the canopy level due to the enhanced leaf area. The expected increase in vapour pressure deficit (VPD) under warmer conditions is generally predicted to decrease the sensitivity of gas exchange to atmospheric CO 2 concentration in both models. The consistent predictions by different models that canopy-level transpiration varies little under elevated CO 2 due to combined stomatal conductance reduction and leaf area increase highlight the coordination of physiological and morphological characteristics in vegetation to maximize resource use (here water) under altered climatic conditions.

54 ENVIRONMENTAL SCIENCES↗

A general method for the analysis of compact multifluid heat exchangers.

An analytical method of treating the complex heat-transfer processes involved in compact multifluid heat exchangers is described. The method is based on representing the heat transfer by means of the analogy between heat-transfer paths and electrical circuits. For plate-fin configurations, it includes the effects of heat exchange among nonadjacent fluids due to conduction through the fins of intervening passages. The application of the developed solution procedures to the design and analysis of multifluid heat exchangers is also discussed. Results obtained in using the electrical-analog method to examine the effects of conduction on performance are presented graphically in parametric form for a number of three-fluid plate-fin configurations. The discussion of the data presented includes a comparison with results given by alternative analytical procedures which neglect direct transfer between nonadjacent fluids.

Demetri, E. P.↗

Valence-bond study of the /H2, D2/ exchange reaction mechanism.

The exchange reaction of H2 with D2 to form 2 HD is important in that it is fundamentally the simplest four-body exchange reaction and should therefore represent a model system on which various theories of reactions dynamics might be tested. A number of theoretical and experimental investigations carried out on this system are reviewed. It is concluded that a Y yields T yields Y mechanism for the (H2, D2) exchange is not a low energy pathway that would make theory compatible with the shock-tube experiments of Bauer and Ossa (1966) and of Burcat and Lifshits (1967).

Freihaut, B.↗

Evidence of charge exchange pumping in calcium-xenon system

Charge exchange between xenon ions and calcium atoms may produce an inversion between the 5s or 4d and 4p energy levels of the calcium ions. A low power flowing xenon plasma seeded with calcium was utilized to determine if charge exchange or electron collisions populate the 5s and 4d levels Ca(+). Line intensity ratios proportional to the density ratios n5s/n4p and n4d/n4p were measured. From the dependence of these intensity ratios on power input to the xenon plasma it was concluded that charge exchange pumping of the 5s and 4d levels predominates over electron collisional pumping of these levels. Also, by comparing intensity ratios obtained using argon and krypton in place of xenon with those obtained in xenon the same conclusion was made.

Chubb, D. L.↗

Wall mounted heat exchanger characterization

Analytical models are presented for describing the heat and mass transfer and the energy distribution in the contents of a cryogenic propellant tank, under varying gravity levels. These models are used to analytically evaluate the effectiveness of a wall heat exchanger as a means of controlling the pressure in the tank during flight and during fill operations. Pressure and temperature histories are presented for tanks varying in size from 4 to 22.5 feet in diameter and gravity levels from 0-1. Results from the subscale test program, utilizing both non-cryogenic and cryogenic fluid, designed to evaluate a tank wall heat exchanger are described and compared with the analytical models. Both the model and test results indicate that a passive tank wall heat exchanger can effectively control tank pressure. However, the weight of such a system is considerably higher than that of an active mixer system.

Bullard, B. R.↗

Charge-exchange plasma generated by an ion thruster

The use of high voltage solar arrays greatly reduces or eliminates power processing requirements in space electric propulsion systems. This use also requires substantial areas of solar array to be at high positive potential relative to space and most of the spacecraft. The charge exchange plasma conducts electrons from the ion beam to such positive surfaces, and thereby electrically load the high voltage solar array. To evaluate this problem, the charge-exchange plasma generated by an ion beam was investigated experimentally. Based upon the experimental data, a simple model was derived for the charge-exchange plasma. This model is conservative in the sense that both the electron/ion density and the electron current density should be equal to, or less than, the preducted value for all directions in the hemisphere upstream of the ion beam direction. Increasing the distance between a positive potential surface (such as a high voltage solar array) and the thruster is the simplest way to control interactions. Both densities and currents vary as the inverse square of this distance.

Kaufman, H. R.↗

Charge exchange in zinc-neon

Excitation of the 4d and 5p levels of Zn+ by charge exchange bewteen Ne+ and Zn was investigated. From measured electron temperature and line intensity ratios it was concluded that charge exchange is the dominate mechanism for populating the 4d2D5/2 level of Zn+. Comparison of Zn-Ne and Zn-Ar results imply the same conclusion. No evidence for charge exchange as the dominant pumping mechanism for the 5p2Pl/2, 5p2P3/2, or 4d2D3/2 levels was obtained.

Chubb, D. L.↗

Ring current proton decay by charge exchange

Explorer 45 measurements during the recovery phase of a moderate magnetic storm have confirmed that the charge exchange decay mechanism can account for the decay of the storm-time proton ring current. Data from the moderate magnetic storm of 24 February 1972 was selected for study since a symmetrical ring current had developed and effects due to asymmetric ring current losses could be eliminated. It was found that after the initial rapid decay of the proton flux, the equatorially mirroring protons in the energy range 5 to 30 keV decayed throughout the L-value range of 3.5 to 5.0 at the charge exchange decay rate calculated by Liemohn. After several days of decay, the proton fluxes reached a lower limit where an apparent equilibrium was maintained, between weak particle source mechanisms and the loss mechanisms, until fresh protons were injected into the ring current region during substorms. While other proton loss mechanisms may also be operating, the results indicate that charge exchange can entirely account for the storm-time proton ring current decay, and that this mechanism must be considered in all studies involving the loss of proton ring current particles.

Smith, P. H.↗