Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

VARI3D & PERSENT: Perturbation and Sensitivity Analysis

The nodal diffusion method is one of the most widely used approaches in modern reactor analysis. In the nodal diffusion method, a coarse multi-group set of “homogenized” parameters is constructed such that the complex geometry of a reactor core along with the energy dependence of neutron and gamma ray cross sections in a nuclear reactor are conserved in the simpler geometry. The homogenization is typically done on a fuel assembly level as is the case in the DIF3D code developed at Argonne National Laboratory. The nodal methodology is used primarily to predict fuel cycle behavior of nuclear systems of which there is a substantial amount of validation in the literature. Another use of the nodal method is to obtain reactivity coefficients and kinetics parameters for use in a safety analysis of a given nuclear reactor. While there are many ways to obtain reactivity worth and kinetics parameters, the work presented in this manuscript is unique as it provides the user with the ability to compute reactivity worths, kinetics parameters, and cross section sensitivities with a Cartesian and hexagonal geometry based transport code. This manuscript serves as a single manual for two separate codes: VARI3D and PERSENT. The VARI3D code (VARIational 3D) is based upon the classic finite difference diffusion theory solver available in DIF3D. The PERSENT code (PERturbation and SENitivity for Transport) is based upon the variational nodal method employed in DIF3D termed VARIANT. The VARIANT solver was added to DIF3D in 1995 and has seen continued development and use for the last 18 years. Because VARI3D primarily uses deprecated coding practices, rather than incorporating the perturbation and sensitivity treatments for transport within VARI3D, a new coding development was built using modern Fortran coding. The primary purpose of this manual is to describe the theory behind PERSENT (and by convenience, that of VARI3D) and discuss the input and output of PERSENT along with giving potential users an idea of how to use it. While this manuscript does describe the input and output of VARI3D, the PERSENT code is intended to be the replacement capability of VARI3D as PERSENT can generate nearly identical (if not superior) diffusion theory results. In this manuscript, the relevant aspects of generalized perturbation theory and exact perturbation theory that apply to both VARI3D and PERSENT are covered. The input and output of VARI3D is displayed by excerpting several of the example problems. Similarly, the input and output of PERSENT is displayed along with tips on how best to use the code. Note that the input and output of the inhomogeneous solver wrapped around DIF3D (DIF3D_IFS) is also discussed as it is needed to carry out some of the sensitivities in PERSENT such as reaction rate ratios. This manuscript describes several perturbation and sensitivity problems, and the results computed using PERSENT. From these sections, potential users should find that PERSENT provides not only the typical tables of numbers desired in perturbation and sensitivity analysis work, but also can visually plot the result for a more thorough understanding of the space and energy distribution (Section 5). Overall, PERSENT is observed to produce accurate reactivity worths and sensitivities for the displayed set of test problems and clearly demonstrates the need to have a transport-based sensitivity capability as evident from the thousands of percent errors observed in the 21-group hexagonal fast reactor problem (covered in Section 7). The uncertainty calculation capability is described in Section 3 and demonstrated in Section 7.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Observability of fidelity decay at the Lyapunov rate in few-qubit quantum simulations

In certain regimes, the fidelity of quantum states will decay at a rate set by the classical Lyapunov exponent. This serves both as one of the most important examples of the quantum-classical correspondence principle and as an accurate test for the presence of chaos. While detecting this phenomenon is one of the first useful calculations that noisy quantum computers without error correction can perform, a thorough study of the quantum sawtooth map reveals that observing the Lyapunov regime is just beyond the reach of present-day devices. We prove that there are three bounds on the ability of any device to observe the Lyapunov regime and give the first quantitatively accurate description of these bounds: (1) the Fermi golden rule decay rate must be larger than the Lyapunov rate, (2) the quantum dynamics must be diffusive rather than localized, and (3) the initial decay rate must be slow enough for Lyapunov decay to be observable. This last bound, which has not been recognized previously, places a limit on the maximum amount of noise that can be tolerated. The theory implies that an absolute minimum of 6 qubits is required. Recent experiments on IBM-Q and IonQ imply that some combination of a noise reduction by up to 100x per gate and large increases in connectivity and gate parallelization are also necessary. Finally, scaling arguments are given that quantify the ability of future devices to observe the Lyapunov regime based on trade-offs between hardware architecture and performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon (Non)Conservation in the Reduced Speed of Light Approximation and How to (Almost) Fix It

The "Reduced Speed of Light" (RSL) approximation is commonly used to speed up radiative transfer calculations in cosmological simulations. However, it has been shown previously that the RSL approximation leads to photon non-conservation when the radiation field is rapidly evolving in time. I show that these missing photons can be counted exactly for some numerical schemes. Adding them back into a simulation, however, is a much harder task. I show one example of such a scheme, which achieves sub-percent accuracy on simple tests. Unfortunately, the scheme performs much worse on semi-realistic simulations of cosmic reionization, leading to a faster overlap and significant errors in the point-wise comparison of the RSL radiation field with the reference simulation that maintains the full speed of light for the radiative transfer.

Gnedin, Nickolay Y. [Fermilab; Chicago U., KICP; C↗

INVESTIGATION OF HUMAN RELIABILITY ANALYSIS METHODS FOR ANALYZING PRE-INITIATORS

As a type of human actions defined in human reliability analysis (HRA), pre-initiator refers to the human actions that may lead to the unavailability of systems, typically committed during maintenance, test, or calibration. This paper investigates representative HRA methods used for analyzing pre-initiators. The HRA methods are Technique for Human Error Rate Prediction (THERP), Korean Standard HRA (K-HRA) and Standard Plant Risk HRA (SPAR-H). In this paper, characteristics of each HRA method are compared for qualitative and quantification aspects. Two pre-initiators, i.e., a calibration task and a valve restoration task, are analyzed using the HRA methods to compare human error probabilities. Then, insights from the analysis and additional research requirements are discussed in this paper.

99 GENERAL AND MISCELLANEOUS↗

INVESTIGATION OF HUMAN RELIABILITY ANALYSIS METHODS FOR ANALYZING PRE-INITIATORS

As a type of human actions defined in human reliability analysis (HRA), pre-initiator refers to the human actions that may lead to the unavailability of systems, typically committed during maintenance, test, or calibration. This paper investigates representative HRA methods used for analyzing pre-initiators. The HRA methods are Technique for Human Error Rate Prediction (THERP), Korean Standard HRA (K-HRA) and Standard Plant Risk HRA (SPAR-H). In this paper, characteristics of each HRA method are compared for qualitative and quantification aspects. Two pre-initiators, i.e., a calibration task and a valve restoration task, are analyzed using the HRA methods to compare human error probabilities. Then, insights from the analysis and additional research requirements are discussed in this paper.

99 GENERAL AND MISCELLANEOUS↗

Leveraging Machine Learning Capabilities for the Characterization of Irradiated Uranium: A Case Study of Analysis Methods for Nuclear Safeguards and Nuclear Forensics

Nondestructively determining the initial enrichment of irradiated uranium is a complex and laborious multivariable problem due to the presence of fission products. This work demonstrates the capabilities of machine learning to analyze gamma-ray spectral data to determine initial enrichment without knowledge of the decay time of the sample. The approach developed is agnostic to the particular scenario and is applicable to a wide variety of applications in nuclear forensics and nuclear safeguards. We irradiated 5 mg uranium standard reference materials at discrete enrichment values ranging from 0.02% to 97% 235 U (weight percent) in UT Austin’s Nuclear Engineering Teaching Laboratory TRIGA Mark II 1.1 MW research reactor, allowed each to decay for 8 hours, and then measured each sample via gamma-ray spectrometry for 50 hours post-irradiation yielding 1,400 individual gamma-ray spectra discretized into 8,192 energy bins. We then trained decision trees models to analyze individual gamma-ray spectra and estimate the associated initial enrichment without knowledge of the time since end of irradiation. We evaluated the performance of the models with a reserved test set not used for training or calibrating the model. A decision tree model constructed with this procedure achieved a mean absolute error in initial enrichment determination of 2.3% (weight percent 235 U). Next, we implemented a principal component analysis pre-processing routine of the gamma-ray spectrometry data to reduce the dimensionality of the dataset from 8,192 channels in the spectrum to 10 principal components while retaining over 99% of the inherent variance in the data. Decision tree models constructed with these data demonstrated decreased mean absolute error in enrichment determination, reduced computational time, and decreased complexity. A single decision tree model constructed with this procedure achieved a mean absolute error in initial enrichment determination of 0.05% (weight percent 235 U). Furthermore, we analyzed these models with learning curves to ensure that overfitting did not occur. The capabilities provided by these models can be naturally extended to other application-focused measurements in the fields of nuclear safeguards, nuclear forensics, and nuclear non-proliferation.

Drescher, Adam↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Reducing Southern Ocean Shortwave Radiation Errors in the ERA5 Reanalysis with Machine Learning and 25 Years of Surface Observations

Earth system models struggle to simulate clouds and their radiative effects over the Southern Ocean, partly due to a lack of measurements and targeted cloud microphysics knowledge. We have evaluated biases of downwelling shortwave radiation in the ERA5 climate reanalysis using 25 years (1995–2019) of summertime surface measurements, collected on the Research and Supply Vessel (RSV) Aurora Australis, the Research Vessel (R/V) Investigator, and at Macquarie Island. During October–March daylight hours, the ERA5 simulation of SW down exhibited large errors (mean bias = 54 W m -2 , mean absolute error = 82 W m -2 , root-mean-square error = 132 W m -2 , and R 2 = 0.71). To determine whether we could improve these statistics, we bypassed ERA5’s radiative transfer model for SW down with machine learning–based models using a number of ERA5’s gridscale meteorological variables as predictors. These models were trained and tested with the surface measurements of SW down using a 10-fold shuffle split. An extreme gradient boosting (XGBoost) and a random forest–based model setup had the best performance relative to ERA5, both with a near complete reduction of the mean bias error, a decrease in the mean absolute error and root-mean-square error by 25% ± 3%, and an increase in the R 2 value of 5% ± 1% over the 10 splits. Large improvements occurred at higher latitudes and cyclone cold sectors, where ERA5 performed most poorly. We further interpret our methods using Shapley additive explanations. Our results indicate that data-driven techniques could have an important role in simulating surface radiation fluxes and in improving reanalysis products.

54 ENVIRONMENTAL SCIENCES↗

Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions

Concurrent measurements of methane (CH 4 ) and ethane (C 2 H 6 ) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C 2 H 6 , while the water vapor correction dominated the CH 4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH 4 and 0.35–0.37 ppb C 2 H 6 . Laboratory intercomparisons showed network compatibility within 1.2 ppb CH 4 and 0.23 ppb C 2 H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH 4 . Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH 4 and 2 ppb C 2 H 6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.

03 NATURAL GAS↗

Analysis of Screening Current Effects in a Hybrid Nb$_{3}$Sn/REBCO Superconducting Accelerator Magnet Using a T - A Formulation

To explore the feasibility of using high-temperature superconducting (HTS) REBCO coated conductors in future accelerator magnets, two REBCO flat racetrack coils were fabricated using 4-mm wide EuBCO tapes at the High Energy Accelerator Research Organization (KEK). These coils were tested as an insert inside a Nb$_{3}$Sn common-coil dipole magnet, which provides a background field of up to $\sim$ 9.5T, at the Brookhaven National Laboratory (BNL). REBCO tapes offer exceptionally high critical current density under strong magnetic fields; however, they also exhibit significant magnetization due to screening currents, leading to magnetic field errors. Here, this study presents a 2D finite element model of screening current-induced fields (SCIF) in REBCO coils using the T-A formulation, along with the results obtained. Simulations were then performed for two KEK test cases: one where the REBCO conductors were oriented with the HTS tapes parallel to the background field, and another where the tapes were perpendicular to it. Since screening currents also influence the stress distribution and increase the peak stress in the coils, the mechanical effects of these currents were analyzed. The implications of these simulation and test results for the design of Nb$_{3}$Sn/REBCO superconducting accelerator magnets are discussed.

Accelerator magnets↗

Field evaluation of semi‐automated moisture estimation from geophysics using machine learning

Geophysical methods can provide three-dimensional (3D), spatially continuous estimates of soil moisture. However, point-to-point comparisons of geophysical properties to measure soil moisture data are frequently unsatisfactory, resulting in geophysics being used for qualitative purposes only. This is because (1) geophysics requires models that relate geophysical signals to soil moisture, (2) geophysical methods have potential uncertainties resulting from smoothing and artifacts introduced from processing and inversion, and (3) results from multiple geophysical methods are not easily combined within a single soil moisture estimation framework. To investigate these potential limitations, an irrigation experiment was performed wherein soil moisture was monitored through time, and several surface geophysical datasets indirectly sensitive to soil moisture were collected before and after irrigation: ground penetrating radar, electrical resistivity tomography (ERT), and frequency domain electromagnetics (FDEM). Data were exported in both raw and processed form, and then snapped to a common 3D grid to facilitate moisture prediction by standard calibration techniques, multivariate regression, and machine learning. A combination of inverted ERT data, raw FDEM, and inverted FDEM data was most informative for predicting soil moisture using a random regression forest model (one-thousand 60/40 training/test cross-validation folds produced root mean squared errors ranging from 0.025–0.046 cm 3 /cm 3 ). This cross-validated model was further supported by a separate evaluation using a test set from a physically separate portion of the study area. Machine learning was conducive to a semi-automated model-selection process that could be used for other sites and datasets to locally improve accuracy.

54 ENVIRONMENTAL SCIENCES↗

A stochastic model of future extreme temperature events for infrastructure analysis

Applying extreme temperature events for future conditions is not straightforward for infrastructure resilience analyses. This work introduces a stochastic model that fills this gap. The model uses at least 50 years of daily extreme temperature records, climate normals with 10%-90% confidence intervals, and shifts/offsets for increased frequency and intensity of heat wave events. Intensity and frequency are shifted based on surface temperature anomaly from 1850-1900 for 32 models from CMIP6. A case study for Worcester, Massachusetts passed 85% of cases using the two-sided Kolmogorov-Smirnov -value test with 95% confidence for both temperature and duration. Future shifts for several climate scenarios to 2020, 2040, 2060, and 2080 had acceptable errors between the shifted model and 10- and 50-year extreme temperature event thresholds with the largest error being 2.67 degrees C. The model is likely to be flexible enough for other patterns of extreme weather such as extreme precipitation and hurricanes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-driven acoustic measurement of moisture content in flowing biomass

Measuring the moisture content in flowing biomass is critical to processes such as liquid biofuel conversion, such as biogasoline, biodiesel, bio jet kerosene, etc. However, biomass tends to flow in aggregates, which results in significant inhomogeneities in the amount of biomass flowing in front of a sensor at a given time, and there can be significant overlap in the material properties of dry vs wet biomass, leading to poor signal-to-noise ratio. We present a technique for identifying biomass moisture content using a series of acoustic pitch-catch measurements to quantify the sound speed and acoustic amplitude through the biomass, in conjunction with classical machine learning techniques, including Naive Bayes, Random Forest, and K-Nearest Neighbors classification. We amplify the differences between the acoustic measurements in different moisture levels by collecting a series of pulse-echo measurements, which we sort in order of ascending sound speed. We test the accuracy of the technique on experimentally-prepared batches of corn stover biomass with specified moisture levels and measure the average error in the estimated moisture level as a function of the number of pitch-catch measurements used. We observe average estimation errors as low as 6.7% by increasing the number of measurements and optimizing the hyperparameters. This work presents a novel method determining moisture content in flowing biomass with inhomogeneous flow. Additionally, this technique has application in optimizing biomass conversion processes, as well as other fields including, paper production, natural fiber processing, and mineral extraction.

09 BIOMASS FUELS↗

Imperfect slope measurements drive overestimation in a geometric cone model of lake and reservoir depth

Lake and reservoir (waterbody) depth is a critical characteristic that influences many important ecological processes. Unfortunately, depth measurements are labor-intensive to gather and are only available for a small fraction of waterbodies globally. Therefore, scientists have tried to predict depth from characteristics easily obtained for all waterbodies, such as surface area or the slope of the surrounding land. One approach for predicting waterbody depth simulates basins using a geometric cone model where the nearshore land slope and distance to the center of the waterbody are assumed to be representative proxies for in-lake slope and distance to the deepest point respectively. We tested these assumptions using bathymetry data from ~5000 lakes and reservoirs to examine whether differences in waterbody type or shape influenced depth prediction error. Here, we found that nearshore land slope was not representative of in-lake slope, and using it for prediction increases error substantially relative to models using true in-lake slope for all waterbody types and shapes. Predictions were biased toward overprediction in concave waterbodies (i.e., bowl-shaped; up to 18% of the study population) and reservoir waterbodies (up to 30% of the study population). Despite this systematic overprediction, model errors were fewer (in absolute and relative terms, irrespective of any specific slope covariate) for concave than convex waterbodies, suggesting the geometric cone model is an adequate representation of depth for these waterbodies. But because convex waterbodies are far more common (>72% of our study population), minimizing overall depth prediction error remains a challenge.

54 ENVIRONMENTAL SCIENCES↗

Redshift evolution and covariances for joint lensing and clustering studies with DESI Y1

ABSTRACT Galaxy–galaxy lensing (GGL) and clustering measurements from the Dark Energy Spectroscopic Instrument Year 1 (DESI Y1) data set promise to yield unprecedented combined-probe tests of cosmology and the galaxy–halo connection. In such analyses, it is essential to identify and characterize all relevant statistical and systematic errors. We forecast the covariances of DESI Y1 GGL + clustering measurements and the systematic bias due to redshift evolution in the lens samples. Focusing on the projected clustering and GGL correlations, we compute a Gaussian analytical covariance, using a suite of N-body and lognormal simulations to characterize the effect of the survey footprint. Using the DESI one percent survey data, we measure the evolution of galaxy bias parameters for the DESI luminous red galaxy (LRG) and bright galaxy survey (BGS) samples. We find mild evolution in the LRGs in $0.4 < z < 0.8$, subdominant to the expected statistical errors. For BGS, we find less evolution for brighter absolute magnitude cuts, at the cost of reduced sample size. We find that for a redshift bin width $\Delta z = 0.1$, evolution effects on DESI Y1 GGL is negligible across all scales, all fiducial selection cuts, all fiducial redshift bins. Galaxy clustering is more sensitive to evolution due to the bias squared scaling. Nevertheless the redshift evolution effect is insignificant for clustering above the 1-halo scale of $0.1h^{-1}$ Mpc. For studies that wish to reliably access smaller scales, additional treatment of redshift evolution is likely needed. This study serves as a reference for GGL and clustering studies using the DESI Y1 sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved energies and local energies with weighted variational Monte Carlo

Neural network parametrizations have increasingly been used to represent the ground and excited states in variational Monte Carlo (VMC) with promising results. However, traditional VMC methods only optimize the wave function in regions of peak probability. The wave function is uncontrolled in the tails of the probability distribution, which can limit the accuracy of the trained wave function. To improve the approximation accuracy in the probability tails, this paper interprets VMC as a gradient flow in the space of wave functions, followed by a projection step. From this perspective, arbitrary probability distributions can be used in the projection step, allowing the user to prioritize accuracy in different regions of state space. Motivated by this theoretical perspective, the paper tests a weighted VMC method on the antiferromagnetic Heisenberg model for a periodic spin chain. Compared to traditional VMC, weighted VMC reduces the error in the ground state energy by a factor of 2, and it reduces the errors in the local energies away from the mode by large factors of 10 2 –10 4 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗