Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Effect of Evanescent Waves on the Dark Current of Thermophotovoltaic Cells

The output power of thermophotovoltaic (TPV) cells may be greatly increased when the gap between the emitter and cell is reduced to submicron distances (near-field regime), at which photon tunneling due to evanescent waves becomes important. Accurate modeling of TPV cells in these conditions is crucial for the design and optimization of near-field TPV systems. The conventional or standard modeling method uses the summation of the dark current and the short-circuit current, while the direct method applies the photon chemical potential. It has been shown that the two methods are linked through a modification of the direct method using Wien’s approximation. By contrasting different modeling approaches, we quantitatively analyze the effects of evanescent waves on the TPV cell performance parameters, especially the dark current, for different emitter and cell materials in the near-field regime. Our results show that the saturation current by radiative recombination is strongly affected by evanescent waves and the bandgap energy. The current-voltage characteristics calculated by different modeling methods are displayed to demonstrate that a constant saturation current typically used in the standard method could cause substantial error in the near-field regime. Finally, for a TPV system with an emitter operating at relatively low temperatures, we show that it is necessary to include the photon chemical potential in the computation of the net radiative heat transfer between the emitter and receiver.

14 SOLAR ENERGY↗

Simulation of an automatically-controlled STOL aircraft in a microwave landing system multipath environment

The simulated response is described of a STOL aircraft to Microwave Landing System (MLS) multipath errors during final approach and touchdown. The MLS azimuth, elevation, and DME multipath errors were computed for a relatively severe multipath environment at Crissy Field California, utilizing an MLS multipath simulation at MIT Lincoln Laboratory. A NASA/Ames six-degree-of-freedom simulation of an automatically-controlled deHavilland C-8A STOL aircraft was used to determine the response to these errors. The results show that the aircraft response to all of the Crissy Field MLS multipath errors was small. The small MLS azimuth and elevation multipath errors did not result in any discernible aircraft motion, and the aircraft response to the relatively large (200-ft (61-m) peak) DME multipath was noticeable but small.

Toda, M.↗

Shear testing of fiber reinforced metal matrix composites

This paper outlines the elements of a combined experimental/analytical methodology for accurate shear characterization of unidirectional composites in the linear and nonlinear range, with particular attention devoted to metal matrix composites. It is illustrated that consistent results can be obtained for a large class of composites from two commonly employed shear test methods currently in use by composites researchers when the influence of various factors that affect the determination of the actual shear response is properly analyzed. These factors include the effects of material anisotropy, specimen geometry, manner of load introduction, and test fixture design on the stress and deformation fields in the test section of off-axis and Iosipescu specimens. Common errors associated with the measurement of deformation fields and calculation of stress fields are discussed and quantified. Particular problems in the determination of the shear response of unidirectional boron/aluminum using the Iosipescu test are illustrated and discussed.

Pindera, Marek-Jerzy↗

NASA airborne Doppler lidar program: Data characteristics of 1981

The first flights of the NASA/Marshall airborne CO2 Doppler lidar wind measuring system were made during the summer of 1981. Successful measurements of two-dimensional flow fields were made to ranges of 15 km from the aircraft track. The characteristics of the data obtained are examined. A study of various artifacts introduced into the data set by incomplete compensation for aircraft dynamics is summarized. Most of these artifacts can be corrected by post processing, which reduces velocity errors in the reconstructed flow field to remarkably low levels.

Lee, R. W.↗

Modeling protein structures from predicted contacts with modern molecular dynamics potentials: accuracy, sensitivity, and refinement

Protein structure prediction has become increasingly popular and successful in recent years. An essential step for fragment-free, template-free methods is the generation of a final three-dimensional protein model from a set of predicted amino acid contacts that are often described by interresidue pairwise atomic distances. Here we explore the use of modern, open-source molecular dynamics (MD) engines, which have been continually developed over the last three decades with all-atom Hamiltonians to model biomolecular structure and dynamics, to generate accurate protein structures starting from a set of inferred pairwise distances. Additionally, the ability of MD empirical physical potentials to correct inaccuracies in the predicted geometries is tested. We rigorously characterize the effect of modeling parameters on results, the effect of different amounts of error in the predicted distances on the final structures, and test the ability of post-processing analysis to sort the best models out of a set of statistical replicas. We find that with exact distances and with noisy distances, the method can produce excellent structural models, and that the molecular dynamics force field seems to help correct errors in distance predictions, resisting the effects of applied noise.

Davidson, Russ↗

Classical Non-Markovian Noise in Symmetry-Preserving Quantum Dynamics

In quantum dynamics, symmetries are vital for identifying and assessing conserved quantities that govern the evolution of a quantum system. When promoted to the open quantum system setting, dynamical symmetries can be negatively altered by system-environment interactions, thus, complicating their analysis. Previous work on noisy symmetric quantum dynamics has focused on the Markovian setting, despite the ubiquity of non-Markovian noise in a number of widely used quantum technologies. Here, in this Letter, we develop a framework for quantifying the impact of non-Markovian noise on symmetric quantum evolution via root space decompositions and the filter function formalism. We demonstrate analytically that symmetry-preserving noise maintains the symmetric subspace, while nonsymmetric noise leads to highly specific leakage errors that are block diagonal in the symmetry representation. We support our findings with numerical studies of a transverse-field Ising model and a quantum error detecting code subject to spatiotemporally correlated multiaxis noise. Our results are broadly applicable, providing new analytic insights into the control and characterization of open quantum system dynamics.

decoherence↗

Error growth in operational ECMWF forecasts

A parameterization scheme used at the European Centre for Medium Range Forecasting to model the average growth of the difference between forecasts on consecutive days was extended by including the effect of error growth on forecast model deficiencies. Error was defined as the difference between the forecast and analysis fields during the verification time. Systematic and random errors were considered separately in calculating the error variance for a 10 day operational forecast. A good fit was obtained with measured forecast errors and a satisfactory trend was achieved in the difference between forecasts. Fitting six parameters to forecast errors and differences that were performed separately for each wavenumber revealed that the error growth rate grew with wavenumber. The saturation error decreased with the total wavenumber and the limit of predictability, i.e., when error variance reaches 95 percent of saturation, decreased monotonically with the total wavenumber.

Kalnay, E.↗

Optics correction for the multi-pass FFAG ERL machine eRHIC

Gradient errors in the multi-pass Fixed Field Alternating Gradient (FFAG) Energy Recovery Linac (ERL) machine, eRHIC, distort the beam orbit and therefore cause emittance increase. The localization and correction of gradient errors are essential for an effective orbit correction and emittance preservation. In this report, the methodology and simulation of optics correction for the multi-pass FFAG ERL machine eRHIC will be presented.

43 PARTICLE ACCELERATORS↗

Technical Report: Evaluation of peripheral dose for flattening filter free photon beams

Purpose: To develop a comprehensive peripheral dose (PD) dataset for the two unflattened beams of nominal energy 6 and 10 MV for use in clinical care. Methods: Measurements were made in a 40 × 120 × 20 cm{sup 3} (width × length × depth) stack of solid water using an ionization chamber at varying depths (dmax, 5, and 10 cm), field sizes (3 × 3 to 30 × 30 cm{sup 2}), and distances from the field edge (5–40 cm). The effects of the multileaf collimator (MLC) and collimator rotation were also evaluated for a 10 × 10 cm{sup 2} field. Using the same phantom geometry, the accuracy of the analytic anisotropic algorithm (AAA) and Acuros dose calculation algorithm was assessed and compared to the measured values. Results: The PDs for both the 6 flattening filter free (FFF) and 10 FFF photon beams were found to decrease with increasing distance from the radiation field edge and the decreasing field size. The measured PD was observed to be higher for the 6 FFF than for the 10 FFF for all field sizes and depths. The impact of collimator rotation was not found to be clinically significant when used in conjunction with MLCs. AAA and Acuros algorithms both underestimated the PD with average errors of −13.6% and −7.8%, respectively, for all field sizes and depths at distances of 5 and 10 cm from the field edge, but the average error was found to increase to nearly −69% at greater distances. Conclusions: Given the known inaccuracies of peripheral dose calculations, this comprehensive dataset can be used to estimate the out-of-field dose to regions of interest such as organs at risk, electronic implantable devices, and a fetus. While the impact of collimator rotation was not found to significantly decrease PD when used in conjunction with MLCs, results are expected to be machine model and beam energy dependent. It is not recommended to use a treatment planning system to estimate PD due to the underestimation of the out-of-field dose and the inability to calculate dose at extended distances due to the limits of the dose calculation matrix.

60 APPLIED LIFE SCIENCES↗

A study of the local pressure field in turbulent shear flow and its relation to aerodynamic noise generation

Work during the period of this report has been in three areas: (1) pressure transducer error analysis, (2) fluctuating velocity and pressure measurements in the NASA Lewis 6-inch diameter quiet jet facility, and (3) measurement analysis. A theory was developed and experimentally verified to quantify the pressure transducer velocity interference error. The theory and supporting experimental evidence show that the errors are a function of the velocity field's turbulent structure. It is shown that near the mixing layer center the errors are negligible. Turbulent velocity and pressure measurements were made in the NASA Lewis quiet jet facility. Some preliminary results are included.

Jones, B. G.↗

SU-G-TeP1-03: Beam Quality Correction Factors for Linear Accelerator with and Without Flattening Filter

Purpose: The impact of removing the flattening filter on absolute dosimetry based on IAEA’s TPR-398 and AAPM’s TG-51 was investigated in this study using Monte Carlo simulations. Methods: The EGSnrc software package was used for all Monte Carlo simulations performed in this work. Five different ionization chambers and nine linear accelerator heads have been modeled according to technical drawings. To generate a flattening filter free radiation field the flattening filter was replaced by a 2 mm thick aluminum layer. Dose calculation in a water phantom were performed to calculate the beam quality correction factor k{sub Q} as a function of the beam quality specifiers %dd(10){sub x}, TPR{sub 20,10} and mean photon and electron energies at the point of measurement in photon fields with (WFF) and without flattening filter (FFF). Results: The beam quality correction factor as a function of %dd(10){sub x} differs systematically between FFF and WFF beams for all investigated ionization chambers. The largest difference of 1.8% was observed for the largest investigated Farmer-type ionization chamber with a sensitive volume of 0.69 cm{sup 3}. For ionization chambers with a smaller nominal sensitive volume (0.015 – 0.3 cm{sup 3}) the deviation was less than 0.4% between WFF and FFF beams for %dd(10){sub x} > 62%. The specifier TPR{sub 20,10} revealed only a good correlation between WFF and FFF beams (< 0.3%) for low energies. Conclusion: The results confirm that %dd(10){sub x} is a suitable beam quality specifier for FFF beams with an acceptable bias. The deviation depends on the volume of the ionization chamber. Using %dd(10){sub x} to predict k{sub Q} for a large volume chamber in a FFF photon field may lead to not acceptable errors according to the results of this study. This bias may be caused by the volume effect due to the inhomogeneous photon fields of FFF linear accelerators.

60 APPLIED LIFE SCIENCES↗

An Efficient High-Order Solver for Diffusion Equations with Strong Anisotropy on Non-Anisotropy-Aligned Meshes

This paper concerns numerical solution of the diffusion equation with strong anisotropy on meshes not aligned with the anisotropic vector field. In order to resolve the numerical pollution for simulations on a non-anisotropy-aligned mesh and reduce the associated high computational cost we propose an effective preconditioner, extending our previous work. Similar to the anisotropy-aligned mesh case, we apply the auxiliary space preconditioning framework to design a preconditioner where a continuous finite element space is used as the auxiliary space for the discontinuous finite element space. The key component is an effective line smoother that can mitigate the high-frequency errors perpendicular to the magnetic field. We design a graph-based approach to find such a line smoother that is approximately perpendicular to the vector fields when the mesh does not align with the anisotropy. Finally, numerical experiments for several benchmark problems are presented, demonstrating the effectiveness and robustness of the proposed preconditioner when applied to Krylov iterative methods.

97 MATHEMATICS AND COMPUTING↗

Background Error Covariance Estimation Using Information from a Single Model Trajectory with Application to Ocean Data Assimilation

An attractive property of ensemble data assimilation methods is that they provide flow dependent background error covariance estimates which can be used to update fields of observed variables as well as fields of unobserved model variables. Two methods to estimate background error covariances are introduced which share the above property with ensemble data assimilation methods but do not involve the integration of multiple model trajectories. Instead, all the necessary covariance information is obtained from a single model integration. The Space Adaptive Forecast error Estimation (SAFE) algorithm estimates error covariances from the spatial distribution of model variables within a single state vector. The Flow Adaptive error Statistics from a Time series (FAST) method constructs an ensemble sampled from a moving window along a model trajectory.SAFE and FAST are applied to the assimilation of Argo temperature profiles into version 4.1 of the Modular Ocean Model (MOM4.1) coupled to the GEOS-5 atmospheric model and to the CICE sea ice model. The results are validated against unassimilated Argo salinity data. They show that SAFE and FAST are competitive with the ensemble optimal interpolation (EnOI) used by the Global Modeling and Assimilation Office (GMAO) to produce its ocean analysis. Because of their reduced cost, SAFE and FAST hold promise for high-resolution data assimilation applications.

Error Covariance↗

Background Error Covariance Estimation using Information from a Single Model Trajectory with Application to Ocean Data Assimilation into the GEOS-5 Coupled Model

An attractive property of ensemble data assimilation methods is that they provide flow dependent background error covariance estimates which can be used to update fields of observed variables as well as fields of unobserved model variables. Two methods to estimate background error covariances are introduced which share the above property with ensemble data assimilation methods but do not involve the integration of multiple model trajectories. Instead, all the necessary covariance information is obtained from a single model integration. The Space Adaptive Forecast error Estimation (SAFE) algorithm estimates error covariances from the spatial distribution of model variables within a single state vector. The Flow Adaptive error Statistics from a Time series (FAST) method constructs an ensemble sampled from a moving window along a model trajectory. SAFE and FAST are applied to the assimilation of Argo temperature profiles into version 4.1 of the Modular Ocean Model (MOM4.1) coupled to the GEOS-5 atmospheric model and to the CICE sea ice model. The results are validated against unassimilated Argo salinity data. They show that SAFE and FAST are competitive with the ensemble optimal interpolation (EnOI) used by the Global Modeling and Assimilation Office (GMAO) to produce its ocean analysis. Because of their reduced cost, SAFE and FAST hold promise for high-resolution data assimilation applications.

Data Assimilation↗

Performance comparison for Barnes model 12-1000, Exotech model 100, and Ideas Inc. Biometer Mark 2

Results of tests show that all channels of all instruments, except channel 3 of the Biometer Mark 2, were stable in response to input signals were linear, and were adequately stable in response to temperature changes. The Biometer Mark 2 is labelled with an inappropriate description of the units measured and the dynamic range is a inappropriate for field measurements causing unnecessarily high fractional errors. This instrument is, therefore, quantization limited. The dynamic range and noise performance of the Model 12-1000 are appropriate for remote sensing field research. The field of view and performance of the Model 100A and the Model 12-1000 are satisfactory. The Biometer Mark 2 has not, as yet, been satisfactorily equipped with an acceptable field of view determining device. Neither the widely used aperture plate nor the 24 deg cone are acceptable.

Robinson, B.↗

SU-F-T-384: Step and Shoot IMRT, VMAT and Autoplan VMAT Nasopharnyx Plan Robustness to Linear Accelerator Delivery Errors

Purpose: To identify the robustness of different treatment techniques in respect to simulated linac errors on the dose distribution to the target volume and organs at risk for step and shoot IMRT (ssIMRT), VMAT and Autoplan generated VMAT nasopharynx plans. Methods: A nasopharynx patient dataset was retrospectively replanned with three different techniques: 7 beam ssIMRT, one arc manual generated VMAT and one arc automatically generated VMAT. Treatment simulated uncertainties: gantry, collimator, MLC field size and MLC shifts, were introduced into these plans at increments of 5,2,1,−1,−2 and −5 (degrees or mm) and recalculated in Pinnacle. The mean and maximum doses were calculated for the high dose PTV, parotids, brainstem, and spinal cord and then compared to the original baseline plan. Results: Simulated gantry angle errors have <1% effect on the PTV, ssIMRT is most sensitive. The small collimator errors (±1 and ±2 degrees) impacted the mean PTV dose by <2% for all techniques, however for the ±5 degree errors mean target varied by up to 7% for the Autoplan VMAT and 10% for the max dose to the spinal cord and brain stem, seen in all techniques. The simulated MLC shifts introduced the largest errors for the Autoplan VMAT, with the larger MLC modulation presumably being the cause. The most critical error observed, was the MLC field size error, where even small errors of 1 mm, caused significant changes to both the PTV and the OAR. The ssIMRT is the least sensitive and the Autoplan the most sensitive, with target errors of up to 20% over and under dosages observed. Conclusion: For a nasopharynx patient the plan robustness observed is highest for the ssIMRT plan and lowest for the Autoplan generated VMAT plan. This could be caused by the more complex MLC modulation seen for the VMAT plans. This project is supported by a grant from NSW Cancer Council.

60 APPLIED LIFE SCIENCES↗

Calibration of EBT2 film using a red-channel PDD method in combination with a modified three-channel technique

Purpose: Ashland Inc. EBT2 and EBT3 films are widely used in quality assurance for radiation therapy; however, there remains a relatively high degree of uncertainty [B. Hartmann, M. Martisikova, and O. Jakel, “Homogeneity of Gafchromic EBT2 film,” Med. Phys. 37, 1753–1756 (2010)]. Micke et al. (2011) recently improved the spatial homogeneity using all color channels of a flatbed scanner; however, van Hoof et al. (2012) pointed out that the corrected nonuniformity still requires further investigation for larger fields. To reduce the calibration errors and the uncertainty, the authors propose a new red-channel percentage-depth-dose method in combination with a modified three-channel technique. Methods: For the ease of comparison, the EBT2 film image used in the authors’ previous study (2012) was reanalyzed using different approaches. Photon beams of 6-MV were delivered to two different films at two different beam on times, resulting in the absorption doses of ranging from approximately 30 to 300 cGy at the vertical midline of the film, which was set to be coincident with the central axis of the beam. The film was tightly sandwiched in a 30{sup 3}-cm{sup 3} polystyrene phantom, and the pixel values for red, green, and blue channels were extracted from 234 points on the central axis of the beam and compared with the corresponding depth doses. The film was first calibrated using the multichannel method proposed by Micke et al. (2010), accounting for nonuniformities in the scanner. After eliminating the scanner and dose-independent nonuniformities, the film was recalibrated via the dose-dependent optical density of the red channel and fitted to a power function. This calibration was verified via comparisons of the dose profiles extracted from the films, where three were exposed to a 60° physical wedge field and three were exposed to composite fields, and all of which were measured in a water phantom. A correction for optical attenuation was implemented, and treatment plans of intensity modulated radiation therapy and volumetric modulated arc therapy were evaluated. Results: The method described here demonstrated improved accuracy with reduced uncertainty. The relative error compared with the measurements of a water phantom was less than 1%, and the overall calibration uncertainty was less than 2%. Verification tests revealed that the results were close to those of the authors’ previous study, and all differences were within 3%, except those with a high-dose gradient. The gamma pass rates (2%/2 mm) of the treatment plan evaluated using the method described here were greater than 99%, and no obvious stripe patterns were observed in the dose-difference maps. Conclusions: Spatial homogeneity was significantly improved via the calibration method described here. This technique is both convenient and time-efficient because it does not require cutting the film, and only two exposures are necessary.

60 APPLIED LIFE SCIENCES↗

Using a Commercial Ethernet PHY Device in a Radiation Environment

This work involved placing a commercial Ethernet PHY on its own power boundary, with limited current supply, and providing detection methods to determine when the device is not operating and when it needs either a reset or power-cycle. The device must be radiation-tested and free of destructive latchup errors. The commercial Ethernet PHY's own power boundary must be supplied by a current-limited power regulator that must have an enable (for power cycling), and its maximum power output must not exceed the PHY's input requirements, thus preventing damage to the device. A regulator with configurable output limits and short-circuit protection (such as the RHFL4913, rad hard positive voltage regulator family) is ideal. This will prevent a catastrophic failure due to radiation (such as a short between the commercial device's power and ground) from taking down the board's main power. Logic provided on the board will detect errors in the PHY. An FPGA (field-programmable gate array) with embedded Ethernet MAC (Media Access Control) will work well. The error detection includes monitoring the PHY's interrupt line, and the status of the Ethernet's switched power. When the PHY is determined to be non-functional, the logic device resets the PHY, which will often clear radiation induced errors. If this doesn't work, the logic device power-cycles the FPGA by toggling the regulator's enable input. This should clear almost all radiation induced errors provided the device is not latched up.

Parks, Jeremy↗