Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

The Mismeasure of Mergers: Revised Limits on Self-interacting Dark Matter in Merging Galaxy Clusters

In an influential recent paper, Harvey et al. derive an upper limit to the self-interaction cross section of dark matter (DM) (${\sigma }_{{\rm{DM}}}/m$ < 0.47 cm 2 g -1 at 95% confidence) by averaging the DM–galaxy offsets in a sample of merging galaxy clusters. Using much more comprehensive data on the same clusters, we identify several substantial errors in their offset measurements. Correcting these errors relaxes the upper limit on ${\sigma }_{{\rm{DM}}}/m$ to $\lesssim$2 cm 2 g -1 , following the Harvey et al. prescription for relating offsets to cross sections in a simple solid-body scattering model. Furthermore, many clusters in the sample violate the assumptions behind this prescription, so even this revised upper limit should be used with caution. Although this particular sample does not tightly constrain self-interacting DM models when analyzed this way, we discuss how merger ensembles may be used more effectively in the future. Finally, we conclude that errors inherent in using single-band imaging to identify mass and light peaks do not necessarily average out in a sample of this size, particularly when a handful of substructures constitute a majority of the weight in the ensemble.

79 ASTRONOMY AND ASTROPHYSICS↗

The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 2. How a mistake led BEIR I to adopt LNT

This paper reveals that nearly 25 years after the used Russell's dose-rate data to support the adoption of the linear-no-threshold (LNT) dose response model for genetic and cancer risk assessment, Russell acknowledged a significant under-reporting of the mutation rate of the historical control group. This error, which was unknown to BEIR I, had profound implications, leading it to incorrectly adopt the LNT model, which was a decision that profoundly changed the course of risk assessment for radiation and chemicals to the present. -- Highlights: • The BEAR I Genetics Panel made an error in denying dose rate for mutation. • The BEIR I Genetics Subcommittee attempted to correct this dose rate error. • The control group used for risk assessment by BEIR I is now known to be in error. • Correcting this error contradicts the LNT, supporting a threshold model.

54 ENVIRONMENTAL SCIENCES↗

Shrinking Self-Interaction Errors with the Fermi–Löwdin Orbital Self-Interaction-Corrected Density Functional Approximation

The self-interaction error (SIE) is one of the major drawbacks of practical exchange-correlation functionals for Kohn-Sham density functional theory. Despite this, the use of methods that explicitly remove SIE from approximate density functionals is scarce in the literature due to their relatively high computational cost and lack of consistent improvement over standard modern functionals. Here, we assess the performance of a novel approach recently proposed by Pederson, Ruzsinszky, and Perdew for performing self-interaction free calculations in density functional theory based on Fermi-orbitals. To this end, we employ test sets consisting of reaction energies that are considered particularly sensitive to SIE. We found that the parameter-free Fermi-Löwdin orbital self-interaction correction method combined with standard local spin density approximation (LSDA) and Perdew-Burke-Ernzerhof (PBE) functionals gives a much better estimate of reaction energies compared to their parent LSDA and PBE functionals for most of the reactions in these two sets. They also perform on par with the global PBE0 and range-separated LC-ωPBE hybrids, which partially eliminate the SIE by including Hartree-Fock exchange. This shows the potential of the Fermi-Löwdin orbital self-interaction corrected (FLOSIC) method for practical density functional calculations without SIE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MRI-Based Computed Tomography Metal Artifact Correction Method for Improving Proton Range Calculation Accuracy

Purpose: Computed tomography (CT) artifacts can severely degrade dose calculation accuracy in proton therapy. Prompted by the recently increased popularity of magnetic resonance imaging (MRI) in the radiation therapy clinic, we developed an MRI-based CT artifact correction method for improving the accuracy of proton range calculations. Methods and Materials: The proposed method replaces corrupted CT data by mapping CT Hounsfield units (HU number) from a nearby artifact-free slice, using a coregistered MRI. MRI and CT volumetric images were registered with use of 3-dimensional (3D) deformable image registration (DIR). The registration was fine-tuned on a slice-by-slice basis by using 2D DIR. Based on the intensity of paired MRI pixel values and HU from an artifact-free slice, we performed a comprehensive analysis to predict the correct HU for the corrupted region. For a proof-of-concept validation, metal artifacts were simulated on a reference data set. Proton range was calculated using reference, artifactual, and corrected images to quantify the reduction in proton range error. The correction method was applied to 4 unique clinical cases. Results: The correction method resulted in substantial artifact reduction, both quantitatively and qualitatively. On respective simulated brain and head and neck CT images, the mean error was reduced from 495 and 370 HU to 108 and 92 HU after correction. Correspondingly, the absolute mean proton range errors of 2.4 cm and 1.7 cm were reduced to less than 2 mm in both cases. Conclusions: Our MRI-based CT artifact correction method can improve CT image quality and proton range calculation accuracy for patients with severe CT artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection

A novel method to detect and correct inaccuracies in a set of unconstrained dense correspondences between two images is presented. Starting with a robust, general-purpose dense correspondence algorithm, an initial pose estimate and dense 3D scene reconstruction are obtained and bundle-adjusted. Reprojection errors are then computed for each correspondence pair, which is used as a metric to distinguish high and low-error correspondences. An affine neighborhood-based coarse-to-fine iterative search algorithm is then applied only on the high-error correspondences to correct their positions. Such an error detection and correction mechanism is novel for unconstrained dense correspondences, for example not obtained through epipolar geometry-based guided matching. Results indicate that correspondences in regions with issues such as occlusions, repetitive patterns and moving objects can be identified and corrected, such that a more accurate set of dense correspondences results from the feedback-based process, as proven by more accurate pose and structure estimates.

99 GENERAL AND MISCELLANEOUS↗

Decoupled recovery of energy and momentum with correction of n = 2 error fields

Experiments applying known n = 2 “proxy” error fields (EFs) find that the rotation braking introduced by the proxy EF cannot be completely alleviated through optimal n = 2 correction with poorly matched poloidal spectra. This imperfect performance recovery demonstrates the importance of correcting multiple components of the n = 2 field spectrum and is in contrast to previous results with n = 1 EFs despite similar execution. Measured optimal n = 2 proxy EF correction currents are consistent with those required to null dominant mode coupling to the resonant surfaces and minimize the neoclassical toroidal viscosity (NTV) torque, calculated using ideal MHD plasma response computation. Unlike rotation braking, density pumpout can be fully corrected despite poorly matched spectra, indicating density pumpout is driven only by a single component proportional to the resonant coupling. Through precise n = 2 spectral control density pumpout and rotation braking can thus be decoupled. Rotation braking with n = 2 fields is also found to be proportional to the level of concurrent toroidal rotation, consistent with NTV theory. Lastly, plasmas with modest countercurrent rotation are insensitive to the n = 2 field with neither rotation braking nor density pumpout observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction for dynamic bias error in transmission measurements of void fraction

Dynamic bias errors occur in transmission measurements, such as X-ray, gamma, or neutron radiography or tomography. This is observed when the properties of the object are not stationary in time and its average properties are assessed. The nonlinear measurement response to changes in transmission within the time scale of the measurement implies a bias, which can be difficult to correct for. A typical example is the tomographic or radiographic mapping of void content in dynamic two-phase flow systems. In this work, the dynamic bias error is described and a method to make a first-order correction is derived. A prerequisite for this method is variance estimates of the system dynamics, which can be obtained using high-speed, time-resolved data acquisition. However, in the absence of such acquisition, a priori knowledge might be used to substitute the time resolved data. Using synthetic data, a void fraction measurement case study has been simulated to demonstrate the performance of the suggested method. The transmission length of the radiation in the object under study and the type of fluctuation of the void fraction have been varied. Significant decreases in the dynamic bias error were achieved to the expense of marginal decreases in precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Is ExacTrac x-ray system an alternative to CBCT for positioning patients with head and neck cancers?

Purpose: To evaluate the usefulness of a six-degrees-of freedom (6D) correction using ExacTrac robotics system in patients with head-and-neck (HN) cancer receiving radiation therapy.Methods: Local setup accuracy was analyzed for 12 patients undergoing intensity-modulated radiation therapy (IMRT). Patient position was imaged daily upon two different protocols, cone-beam computed tomography (CBCT), and ExacTrac (ET) images correction. Setup data from either approach were compared in terms of both residual errors after correction and punctual displacement of selected regions of interest (Mandible, C2, and C6 vertebral bodies).Results: On average, both protocols achieved reasonably low residual errors after initial correction. The observed differences in shift vectors between the two protocols showed that CBCT tends to weight more C2 and C6 at the expense of the mandible, while ET tends to average more differences among the different ROIs.Conclusions: CBCT, even without 6D correction capabilities, seems preferable to ET for better consistent alignment and the capability to see soft tissues. Therefore, in our experience, CBCT represents a benchmark for positioning head and neck cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DtaRefinery: a software tool for elimination of systematic errors from parent ion mass measurements in tandem mass spectra datasets

Hybrid two-stage mass spectrometers capable of both highly accurate mass measurement and MS/MS fragmentation have become widely available in recent years and have allowed for sig-nificantly better discrimination between true and false MS/MS pep-tide identifications by applying relatively narrow windows for maxi-mum allowable deviations for parent ion mass measurements. To fully gain the advantage of highly accurate parent ion mass meas-urements, it is important to limit systematic mass measurement errors. The DtaRefinery software tool can correct systematic errors in parent ion masses by reading a set of fragmentation spectra, searching for MS/MS peptide identifications, then fitting a model that can estimate systematic errors, and removing them. This results in a new fragmentation spectrum file with updated parent ion masses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recalculation of Soil Bulk Density Used in the Scorpius MCNP6 Model

The soil composition used in the Scorpius MCNP6.2 (Ref. 1) model was recently recalculated. Originally, it was “determined using the United States Geological Survey (USGS) Mercury Core Library and the Nevada National Security Site U.S. Geological Survey Databases (NNSS USGS) and Nevada National Security Site Petrographic, Geochemical, and Geophysical Database (NNSS PGG),” but the details had been lost. Reference 2 documents the updated soil composition determination. Reference 2 estimated the grain density of the soil instead of the bulk density. This report corrects that error. I am indebted to Garrett Euler (EES-17) for reading Ref. 2, pointing out its errors, and guiding me through the correct calculations. This report is organized as follows. For completeness, the composition calculations from Ref. 2 are repeated: Sec. II discusses the data that are reported in the PGG Access database, and Sec. III uses the data in the PGG Access database to compute the composition of the soil. Section IV estimates the bulk density of the soil. Section V evaluates the soil wall thickness in the Scorpius model. Section VI estimates the effect of the soil density change on previously calculated results. Section VII presents a summary and conclusions. Input files and output files are listed in appendices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Search for Lepton Flavor Violation in Two Body Muon and Pion Decay at Rest

The ability of the Mu2e experiment to probe, or discover beyond the Standard Model physics in direct Charged Lepton Flavor Violation $\mu^+$ and $\pi^+$ decay modes is estimated. These direct modes are searched for simultaneously with proposed Mu2e detector validation runs, and are complementary to the Mu2e main search goal, an indirect search for $\mu^- \to e^-$ conversion at the sensitivity level of $\sim 10^{-17}$. The $\mu^+$ validation run will operate at 50% nominal magnetic field and reduced proton beam intensity to less than 1/100th nominal, in order to observe the e+ spectrum from $\mu^+$ decay, at and below the Michel edge Ee . 53 MeV. The $\pi^+$ validation run, based on measuring the mono-energetic e+ emission in the decay $\pi^+ \to e+\nu$, at 76% of nominal magnetic field and reduced beam intensity less than 1/5th nominal. Both of these runs can be used to fix the momentum scale for the Mu2e conversion search. In addition the muon validation dataset can be used to correct for systematic errors in the detector response by mapping the well known to O(\u03B13) corrected theoretical Michel spectrum, to the observed spectrum. One direct search is for two-body Charged Lepton Flavor Violation $\mu^+ \to e^+X$ decay, where $X$ is a light new physics particle. This allows Mu2e to explore well motivated models including axion like particles with flavor violating couplings and massive $Z^0$ bosons with more sensitivity then present astrophysical and laboratory constraints. In two weeks of data-taking, Mu2e can achieve direct mode 90% confidence level branching ratio limits of $10^{-7}$ over the mass range $20 \le m_X \le 50$ MeV, improving the current experimental limit at $10^{-5}$ by two orders of magnitude. In the mass range $m_X \le 20$ MeV, assuming systematic error corrections can be made by correcting the Monte Carlo mapping, the achievable search sensitivity is found to be $2.3\times 10^{-7}$ for $m_X =0$, an order of magnitude improvement over the current best limit at $2.6\times 10^{-6}$, when assuming $V+A$ or isotropic coupling. The $\pi^+$ validation run, allows searching for $\pi^+ \to e^+N$ decay, where $N$ is a heavy neutral lepton such as a heavy sterile neutrino, in the mass region $20 \le m_N \le 65$ MeV. A branching ratio limit at 90% confidence level of $3\times 10^{-8}$ can be achieved in two weeks, an improvement of the current search sensitivity limit by an order of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correction

Residual position errors of the lymph node (LN) surrogates and humeral head (HH) were determined for 2 different arm fixation devices in radiotherapy (RT) of breast cancer: a standard wrist-hold (WH) and a house-made rod-hold (RH). The effect of arm position correction (APC) based on setup images was also investigated. A total of 113 consecutive patients with early-stage breast cancer with LN irradiation were retrospectively analyzed (53 and 60 using the WH and RH, respectively). Residual position errors of the LN surrogates (Th1-2 and clavicle) and the HH were investigated to compare the 2 fixation devices. The position errors and setup margins were determined before and after the APC to investigate the efficacy of the APC in the treatment situation. A threshold of 5 mm was used for the residual errors of the clavicle and Th1-2 to perform the APC, and a threshold of 7 mm was used for the HH. The setup margins were calculated with the van Herk formula. Irradiated volumes of the HH were determined from RT treatment plans. With the WH and the RH, setup margins up to 8.1 and 6.7 mm should be used for the LN surrogates, and margins up to 4.6 and 3.6 mm should be used to spare the HH, respectively, without the APC. After the APC, the margins of the LN surrogates were equal to or less than 7.5/6.0 mm with the WH/RH, but margins up to 4.2/2.9 mm were required for the HH. The APC was needed at least once with both the devices for approximately 60% of the patients. With the RH, irradiated volume of the HH was approximately 2 times more than with the WH, without any dose constraints. Use of the RH together with the APC resulted in minimal residual position errors and setup margins for all the investigated bony landmarks. Based on the obtained results, we prefer the house-made RH. However, more attention should be given to minimize the irradiation of the HH with the RH than with the WH.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correcting Turbulence-induced Errors in Fiber Positioning for the Dark Energy Spectroscopic Instrument

Highly multiplexed, robotic, fiber-fed spectroscopic surveys are observing tens of millions of stars and galaxies. For many systems, accurate positioning relies on imaging the fibers in the focal plane and feeding that information back to the robotic positioners to correct their positions. Inhomogeneities and turbulence in the air between the focal plane and the imaging camera can affect the measured positions of fibers, limiting the accuracy with which fibers can be placed on targets. For the Dark Energy Spectroscopic Instrument, we dramatically reduced the effect of turbulence on measurements of positioner locations in the focal plane by taking advantage of stationary positioners and the correlation function of the turbulence. We were able to reduce positioning errors from 7.3 to 3.5 μm, speeding the survey by 1.6% under typical conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPARC 3D Field Physics and Support of the Non-Axisymmetric Coil Assessment

Commonwealth Fusion Systems (CFS) is deploying SPARC, a net-energy tokamak, by 2025. A notable challenge facing all tokamak approaches to fusion energy production is maintaining a stable plasma and thereby steady energy production. “Disruptions” to plasma operation are often encountered in devices when they operate at high normalized pressure, high normalized density, or high normalized current. SPARC is unique in that it is expected to demonstrate Q>=2 in a plasma with low normalized pressure and density, but with a more modest current limit buffer sufficient to avoid disruptions. Due to both the high normalized current and high magnetic field of the SPARC design, it is expected to decrease its relative resilience to instabilities driven by non-axisymmetry in the externally applied magnetic field, termed ‘error fields’. To prevent error field driven instabilities, a primary line of defense is strict engineering tolerances in magnet fabrication and installation. A secondary line of defense is a purpose-built set of magnetic coils to correct these errors, termed error field correction coils (EFCCs). The overarching goals of this INFUSE project were to evaluate the effectiveness of the EFCCs in the SPARC design and provide guidance as to how to improve this effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination and correction of distortions and systematic errors in low-energy electron diffraction

We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sum-rule corrections: A route to error cancellations in correlation matrix renormalisation theory

Here, we recently proposed the correlation matrix renormalisation (CMR) theory to efficiently and accurately calculate ground state total energy of molecular systems, based on the Gutzwiller variational wavefunction (GWF) to treat the electronic correlation effects. To help reduce numerical complications and better adapt the CMR to infinite lattice systems, we need to further refine the way to minimise the error originated from the approximations in the theory. This conference proceeding reports our recent progress on this key issue, namely, we obtained a simple analytical functional form for the one-electron renormalisation factors, and introduced a novel sum-rule correction for a more accurate description of the intersite electron correlations. Benchmark calculations are performed on a set of molecules to show the reasonable accuracy of the method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photometric and spectroscopic footprint corrections in the SLOAN Digital Sky Survey’s 6th data release

We identify and correct numerous errors within the photometric and spectroscopic footprints (SFs) of the Sloan Digital Sky Survey’s (SDSS) 6th data release (DR6). Within the SDSS’s boundaries hundreds of millions of objects have been detected. Yet we present evidence that the boundaries themselves contain a significant number of mistakes that are being revealed for the first time within this paper. Left unaddressed, these can introduce systematic biases into galaxy clustering statistics. Using the DR6 Main Galaxy Sample (MGS) targets as tracers, we reveal inconsistencies between the photometric and SF definitions provided in the Catalog Archive Server (CAS), and the measurements of targets therein. First, we find that 19.7 deg{sup 2} of the DR6 photometric footprint are devoid of MGS targets. In volumes of radii 7 h{sup −1} Mpc, this can cause errors in the expected number of galaxies to exceed 60%. Second, we identify seven areas that were erroneously included or excluded from the SF. Moreover, the tiling algorithm that positioned spectroscopic fibers during and between DRs caused many areas along the edge of the SF to be significantly undersampled relative to the footprint’s interior. Through our corrections, we increase the completeness 2.2% by trimming 3.6% of the area from the existing SF. The sum total of these efforts has generated the most accurate description of the SDSS DR6 footprints ever created.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate Measurement of Gain Saturation of Superconductor–Insulator–Superconductor Mixers with Logarithmic Power Detectors

Correct measurement of the power of a continuous wave signal superimposed on a broadband noise is a presupposition for the accuracy of the gain saturation measurement of a superconductor–insulator–superconductor mixer. In practice, the response of a logarithmic power detector to a mixture of broadband noise and continuous wave signal can be unexpectedly nonlinear. This nonlinearity can cause significant error if correction is not applied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗