Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error bars”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Head-up displays for STOL visual approaches

A simulation study was conducted to determine the effectiveness of a simple head-up display in improving glide-slope tracking performance during steep visual approaches in a STOL aircraft. The head-up display featured an attitude-stabilized horizon bar and glide-slope reference bar parallel to and 7.5 deg below the horizon bar. On some approaches a flight-path marker symbol showing the projected ground impact point was also displayed. Half of the approaches were flown in a conventional mode in which the pilot changed pitch attitude to correct for height errors. The remaining approaches were flown in a direct-lift mode in which the pilot modulated thrust to change the flight-path angle without pitching the aircraft.

Palmer, E. A.↗

Evidence for B+ -> K*0bar K*+

We present measurements of the branching fraction and fraction of longitudinal polarization for the decay B{sup +} {yields} {bar K}*{sup 0} K*{sup +} with a sample of 467 {+-} 5 million B{bar B} pairs collected with the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the SLAC National Accelerator Laboratory. We obtain the branching fraction {Beta}(B{sup +} {yields} {bar K}*{sup 0} K*{sup +}) = (1.2 {+-} 0.5 {+-} 0.1) x 10{sup ?6} with a significance of 3.7 standard deviations including systematic uncertainties. We measure the fraction of longitudinal polarization f{sub L} = 0.75{sub -0.26}{sup +0.16} {+-} 0.03. The first error quoted is statistical and the second is systematic.

43 PARTICLE ACCELERATORS↗

Mapping DNA polymerase errors by single-molecule sequencing

Genomic integrity is compromised by DNA polymerase replication errors, which occur in a sequence-dependent manner across the genome. Accurate and complete quantification of a DNA polymerase's error spectrum is challenging because errors are rare and difficult to detect. We report a high-throughput sequencing assay to map in vitro DNA replication errors at the single-molecule level. Unlike previous methods, our assay is able to rapidly detect a large number of polymerase errors at base resolution over any template substrate without quantification bias. To overcome the high error rate of high-throughput sequencing, our assay uses a barcoding strategy in which each replication product is tagged with a unique nucleotide sequence before amplification. Here, this allows multiple sequencing reads of the same product to be compared so that sequencing errors can be found and removed. We demonstrate the ability of our assay to characterize the average error rate, error hotspots and lesion bypass fidelity of several DNA polymerases.

60 APPLIED LIFE SCIENCES↗

Verification of Advective Bar Elements Implemented in the Sierra/Aria Thermal Response Code

A thorough code verification effort has been performed on a reduced order, finite element model for 1D fluid flow convectively coupled with a 3D solid, referred to as the 'advective bar' model. The purpose of this effort was to provide confidence in the proper implementation of this model within the SIERRA/Aria thermal response code at Sandia National Laboratories. The method of manufactured solutions is applied so that the order of convergence in error norms for successively refined meshes and timesteps is investigated. Potential pitfalls that can lead to a premature evaluation of the model's implementation are described for this verification approach when applied to this unique model. As a result, through observation of the expected order of convergence, these verification tests provide evidence of proper implementation of the model within the codebase.

42 ENGINEERING↗

Total pressure averaging in pulsating flows

A number of total-pressure tubes were tested in a non-steady flow generator in which the fraction of period that pressure is a maximum is approximately 0.8, thereby simulating turbomachine-type flow conditions. Most of the tubes indicated a pressure which was higher than the true average. Organ-pipe resonance which further increased the indicated pressure was encountered within the tubes at discrete frequencies. There was no obvious combination of tube diameter, length, and/or geometry variation used in the tests which resulted in negligible averaging error. A pneumatic-type probe was found to measure true average pressure, and is suggested as a comparison instrument to determine whether nonlinear averaging effects are serious in unknown pulsation profiles. The experiments were performed at a pressure level of 1 bar, for Mach number up to near 1, and frequencies up to 3 kHz.

Krause, L. N.↗

Visual PEF Reader - VIPER

This software graphically displays all pertinent information from a Predicted Events File (PEF) using the Java Swing framework, which allows for multi-platform support. The PEF is hard to weed through when looking for specific information and it is a desire for the MRO (Mars Reconn aissance Orbiter) Mission Planning & Sequencing Team (MPST) to have a different way to visualize the data. This tool will provide the team with a visual way of reviewing and error-checking the sequence product. The front end of the tool contains much of the aesthetically appealing material for viewing. The time stamp is displayed in the top left corner, and highlighted details are displayed in the bottom left corner. The time bar stretches along the top of the window, and the rest of the space is allotted for blocks and step functions. A preferences window is used to control the layout of the sections along with the ability to choose color and size of the blocks. Double-clicking on a block will show information contained within the block. Zooming into a certain level will graphically display that information as an overlay on the block itself. Other functions include using hotkeys to navigate, an option to jump to a specific time, enabling a vertical line, and double-clicking to zoom in/out. The back end involves a configuration file that allows a more experienced user to pre-define the structure of a block, a single event, or a step function. The individual will have to determine what information is important within each block and what actually defines the beginning and end of a block. This gives the user much more flexibility in terms of what the tool is searching for. In addition to the configurability, all the settings in the preferences window are saved in the configuration file as well

Luo, Victor↗

Comparative Analysis of Imaging and Measurements of Micrometer-Scale Fracture Aperture Fields Within a Heterogeneous Rock Using PET and X-ray CT

Knowledge of the spatial distribution of fracture apertures is essential for reliable characterization of flow and transport processes in fractured systems and for better understanding of physicochemical matrix–fracture interactions. Here, we propose and test two image-based methods, thereby extending the current experimental capabilities to characterize aperture size distribution in structurally heterogeneous geologic porous media noninvasively. The first approach utilizes an inversion method based on the dataset acquired from positron emission tomography (PET) and the second approach considers an extension of the classic missing attenuation technique that relies on clinical X-ray computed tomography (X-ray CT). Independent sets of imaging experiments are conducted on a fractured basalt core with heterogeneous matrix properties and aperture distributions to compare the two methodologies. A repeat of each experiment is conducted to verify the proposed workflows. The performance of these two imaging techniques is systematically evaluated through the analysis of signal-to-noise ratio, minimum fracture size detectability, and measurement errors. While both approaches provide a reliable estimation of fracture aperture distributions, PET yields a signal-to-noise ratio that is substantially higher than the corresponding X-ray CT measurements. Furthermore, uncertainties of the aperture values for PET are considerably lower ($\bar {\sigma}_{\text {d}} = 15\%$) compared to those obtained from X-ray CT ($\bar {\sigma}_{\text {d}} = 29\%$), allowing for the detection of minimum aperture sizes of 20 $\mu$m with 70% confidence level. Finally, these approaches provide key experimental tools for better understanding dynamic hydromechanical fracture properties in geologic systems.

58 GEOSCIENCES↗

First measurement of Φ₃ with a model-independent Dalitz plot analysis of B ± →DK ± , D→K S ⁰π⁺π⁻ decay

We present the first measurement of the angle Φ₃ of the unitarity triangle using a model-independent Dalitz plot analysis of B ± →DK ± , D→K S ⁰π⁺π⁻ decays. The method uses, as input, measurements of the strong phase of the D→K⁰ S π⁺π⁻ amplitude from the CLEO Collaboration. The result is based on the full data set of 772×106 BB¯¯¯ pairs collected by the Belle experiment at the Υ(4S) resonance. We obtain Φ₃=(77.3 +15.1 –14.9 ±4.1±4.3)° and the suppressed amplitude ratio r B =0.145±0.030±0.010±0.011. Here the first error is statistical, the second is the experimental systematic uncertainty, and the third is the error due to the precision of the strong-phase parameters obtained by CLEO.

Aihara, H.↗

Validation of clear-sky fluxes for tropical oceans from the Earth Radiation Budget Experiment

The existence and magnitude of a systematic bias in the clear-sky longwave fluxes from the Earth Radiation Budget Experiment (ERBE) is investigated. The bias is apparently introduced because the ERBE method for scene identification does not account for large zonal gradients in longwave absorption by water vapor. The ERBE fluxes are compared to fluxes calculated with a radiative transfer model from ship radiosonde measurements. The comparison is based upon an analysis of 5 yr of coincident satellite and radiosonde observations for equatorial ocean regions. The differences between the ERBE and model fluxes are examined as functions of sea surface temperature (SST) and relative humidity. The authors use height-mean relative humidity bar-RH as an index of atmospheric moisture. The average offset between and model ERBE fluxes ranges between +2 and +6 W/sq m for SSTs above 295 K, and the gradients with respect to SST are nearly identical. However, the difference between the model and ERBE depends significantly on the tropospheric relative humidity. ERBE fluxes exceed model fluxes for bar-RH above 70%, and the maximum offset of +9 to +12 W/sq m is consistent with previous estimates. There are also indications that the clear-sky fluxes for bar-RH below 25% may be underestimated by about 10-15 W/sq m. Since extreme values of height-mean humidity are relatively infrequent, the net bias introduced in the ERBE monthly mean clear-sky fluxes is generally less than the systematic error in estimates introduced in the ERBE monthly mean clear-sky fluxes is generally less than the systematic error in estimates of the instantaneous fluxes. These findings support earlier work on the coupling between SST and the atmospheric greenhouse effect, in particular the existence of a super greenhouse effect for oceans warmer than 300 K. Recent reports of much larger systematic differences are not supported by this analysis. The results indicate that comparison of general circulation model (GCM) and ERBE clear-sky longwave fluxes will depend explicitly on atmospheric humidity.

Collins, W. D.↗

Measurement of Ratios of Branching Fractions and CP-Violating Asymmetries of B+/- --> D*K +/- decays

The authors report a study of B{sup {+-}} {yields} D*K{sup {+-}} decays with D* decaying to D{pi}{sup 0} or D{gamma}, using 383 x 10{sup 6} B{bar B} pairs collected at the {Upsilon}(4S) resonance with the BABAR detector at the SLAC PEP-II B-Factory. The D meson decays under study include a non-CP mode (K{sup {+-}}{pi}{sup {-+}}), CP-even modes (K{sup {+-}}K{sup {-+}}, {pi}{sup {+-}}{pi}{sup {-+}}) and CP-odd modes (K{sub S}{sup 0}{pi}{sup 0}, K{sub S}{sup 0}{phi}, K{sub S}{sup 0}{omega}). They measure ratios (R*{sub CP{+-}}) of branching fractions of decays to CP eigenmode states and to flavor-specific states as well as CP asymmetries A*{sub CP{+-}} = -0.11 {+-} 0.09 {+-} 0.01, R*{sub CP+} = 1.31 {+-} 0.13 {+-} 0.04, and A*{sub CP-} = 0.06 {+-} 0.10 {+-} 0.02, R*{sub CP-} = 1.10 {+-} 0.12 {+-} 0.04, where the first error is statistical and the second error is systematic. Translating the results into an alternative parameterization, widely used for related measurements, they obtain x*{sub +} = 0.11 {+-} 0.06 {+-} 0.02 and x*{sub -} = 0.00 {+-} 0.06 {+-} 0.01. No significant CP-violating charge asymmetry is found in either the flavor-specific mode D {yields} K{sup {+-}}{pi}{sup {-+}} or in B{sup {+-}} {yields} D*{pi}{sup {+-}} decays.

43 PARTICLE ACCELERATORS↗

H{sub 2}(v = 0,1) + C{sup +}({sup 2} P) {yields} H+CH{sup +} STATE-TO-STATE RATE CONSTANTS FOR CHEMICAL PUMPING MODELS IN ASTROPHYSICAL MEDIA

State-to-state rate constants for the title reaction are calculated using the electronic ground state potential energy surface and an accurate quantum wave-packet method. The calculations are performed for H{sub 2} in different rovibrational states, v = 0, 1 and J = 0 and 1. The simulated reaction cross section for v = 0 shows a rather good agreement with the experimental results of Gerlich et al., both with a threshold of 0.36 eV and within the experimental error of 20%. The total reaction rate coefficients simulated for v = 1 are two times smaller than those estimated by Hierl et al. from cross sections measured at different temperatures and neglecting the contribution from v > 1 with an uncertainty factor of two. Thus, part of the disagreement is attributed to the contributions of v > 1. The computed state-to-state rate coefficients are used in our radiative transfer model code applied to the conditions of the Orion Bar photodissociation region, and leads to an increase of the line fluxes of high-J lines of CH{sup +}. This result partially explains the discrepancies previously found with measurements and demonstrates that CH{sup +} excitation is mostly driven by chemical pumping.

74 ATOMIC AND MOLECULAR PHYSICS↗

THE DISKMASS SURVEY. II. ERROR BUDGET

We present a performance analysis of the DiskMass Survey. The survey uses collisionless tracers in the form of disk stars to measure the surface density of spiral disks, to provide an absolute calibration of the stellar mass-to-light ratio ({Upsilon}{sub *}), and to yield robust estimates of the dark-matter halo density profile in the inner regions of galaxies. We find that a disk inclination range of 25{sup 0}-35{sup 0} is optimal for our measurements, consistent with our survey design to select nearly face-on galaxies. Uncertainties in disk scale heights are significant, but can be estimated from radial scale lengths to 25% now, and more precisely in the future. We detail the spectroscopic analysis used to derive line-of-sight velocity dispersions, precise at low surface-brightness, and accurate in the presence of composite stellar populations. Our methods take full advantage of large-grasp integral-field spectroscopy and an extensive library of observed stars. We show that the baryon-to-total mass fraction (F{sub bar}) is not a well-defined observational quantity because it is coupled to the halo mass model. This remains true even when the disk mass is known and spatially extended rotation curves are available. In contrast, the fraction of the rotation speed supplied by the disk at 2.2 scale lengths (disk maximality) is a robust observational indicator of the baryonic disk contribution to the potential. We construct the error budget for the key quantities: dynamical disk mass surface density ({Sigma}{sub dyn}), disk stellar mass-to-light ratio ({Upsilon}{sub *}{sup disk}), and disk maximality (F{sub *,max}{sup disk} {identical_to} V{sub *,max}{sup disk}/ V{sub c}). Random and systematic errors in these quantities for individual galaxies will be {approx}25%, while survey precision for sample quartiles are reduced to 10%, largely devoid of systematic errors outside of distance uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecule-charmonium mixing for the X(3872) in QCD Sum Rules

We use QCD sum rules to test the nature of the meson X(3872), assumed to be a mixture between charmonium and exotic molecular [cq-bar][qc-bar] states with J{sup pc} = 1{sup ++}. We find that only a small range for the values of the mixing angle, 5 deg. {<=}{theta}{<=}13 deg., can provide simultaneously good agreement with the experimental value of the mass and the decay width, within the errors. In this range we get m{sub X} = (3.77{+-}0.18) GeV and {Gamma}(X{yields}J/{psi}{pi}{sup +{pi}-}) = (9.3{+-}6.9) MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MCS solutions for the TVA Watts Bar Unit 1 multi-physics depletion benchmark

The high-fidelity solution for exercises 1-3 of the recently developed TVA Watts Bar Unit 1 multi-physics and multi-cycle depletion benchmark using MCS was coupled with two different thermal-hydraulics (TH) codes: TH1D and COBRA-TF (CTF), and their solutions were compared. The solutions from MCS/CTF and MCS/TH1D for typical Pressurized Water Reactor (PWR) problems are quite close. And to evaluate MCS solutions for the benchmark, their results were also compared against measured data as well as publicly available high-fidelity solutions. The MCS criticality solutions at Hot Zero Power (HZP) deviate within 50 pcm against the reference solutions. While for the critical boron concentration (CBC) search calculations, the difference on the MCS calculated CBC is about 7 ppm, and the root-mean-squared (RMS) errors for the assembly power distribution and outlet coolant temperature are less than 0.5% and 1 Celsius degree respectively. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

OPTIMIZATION-BASED CONSTITUTIVE PARAMETER IDENTIFICATION FROM SPARSE TAYLOR CYLINDER DATA

The classic Taylor impact test imparts temporally and spatially varying fields of strain, strain rate, and temperature through the specimen. It is possible to exploit this complexity to directly identify constitutive model parameters from the deformed shape of the specimen. Where prior investigators have employed various mathematical fitting methods to identify or improve strength model parameters from Taylor cylinder profiles, we extend the method to employ a multi-objective genetic optimization algorithm to minimize the cylinder profile errors simultaneously on three cylinders impacted at different velocities. No experimental data other than the three Taylor cylinders is employed in developing the constitutive model parameter set, and generic starting coefficients are employed. To validate the accuracy of the resulting coefficients, both split Hopkinson pressure bar and axisymmetric expanding ring tests were conducted and compared to the resultant Johnson-Cook strength model. The derived strength model agreed well with experimental data available to date. Further work is necessary to evaluate the range of rates and temperatures over which parameters derived by this method may be applied.

97 MATHEMATICS AND COMPUTING↗

Processing Raman Spectra of High-Pressure Hydrogen Flames

The Raman Code automates the analysis of laser-Raman-spectroscopy data for diagnosis of combustion at high pressure. On the basis of the theory of molecular spectroscopy, the software calculates the rovibrational and pure rotational Raman spectra of H2, O2, N2, and H2O in hydrogen/air flames at given temperatures and pressures. Given a set of Raman spectral data from measurements on a given flame and results from the aforementioned calculations, the software calculates the thermodynamic temperature and number densities of the aforementioned species. The software accounts for collisional spectral-line-broadening effects at pressures up to 60 bar (6 MPa). The line-broadening effects increase with pressure and thereby complicate the analysis. The software also corrects for spectral interference ("cross-talk") among the various chemical species. In the absence of such correction, the cross-talk is a significant source of error in temperatures and number densities. This is the first known comprehensive computer code that, when used in conjunction with a spectral calibration database, can process Raman-scattering spectral data from high-pressure hydrogen/air flames to obtain temperatures accurate to within 10 K and chemical-species number densities accurate to within 2 percent.

Nguyen, Quang-Viet↗

The GPS Transmit Antenna Phase Center and Its Impact on Precise Geophysical Applications

The ionospheric-free (Lc) phase center of the GPS transmit antenna is modeled as a fixed constant in most geodetic software packages. We estimated a phase center offset for all GPS satellites and found large deviations from the nominal values. In particular, meter level deviation was observed for PRN 13 and somewhat smaller anomalies were observed for PRNs 6, 15, 19 and 31. We will present the estimation results for all GPS satellites and describe the estimation process as well as an error budget. We will present evidence that estimating the phase center offset improves the GPS orbits and discuss the impact of phase center mismodeling on various high-precision applications.

Bar-Sever, Y. E.↗