Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “entry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Structural basis for the antibody neutralization of Herpes simplex virus

The gD–E317-Fab complex crystal revealed the conformational epitope of human mAb E317 on HSV gD, providing a molecular basis for understanding the viral neutralization mechanism. Glycoprotein D (gD) of Herpes simplex virus (HSV) binds to a host cell surface receptor, which is required to trigger membrane fusion for virion entry into the host cell. gD has become a validated anti-HSV target for therapeutic antibody development. The highly inhibitory human monoclonal antibody E317 (mAb E317) was previously raised against HSV gD for viral neutralization. To understand the structural basis of antibody neutralization, crystals of the gD ectodomain bound to the E317 Fab domain were obtained. The structure of the complex reveals that E317 interacts with gD mainly through the heavy chain, which covers a large area for epitope recognition on gD, with a flexible N-terminal and C-terminal conformation. The epitope core structure maps to the external surface of gD, corresponding to the binding sites of two receptors, herpesvirus entry mediator (HVEM) and nectin-1, which mediate HSV infection. E317 directly recognizes the gD–nectin-1 interface and occludes the HVEM contact site of gD to block its binding to either receptor. The binding of E317 to gD also prohibits the formation of the N-terminal hairpin of gD for HVEM recognition. The major E317-binding site on gD overlaps with either the nectin-1-binding residues or the neutralizing antigenic sites identified thus far (Tyr38, Asp215, Arg222 and Phe223). The epitopes of gD for E317 binding are highly conserved between two types of human herpesvirus (HSV-1 and HSV-2). This study enables the virus-neutralizing epitopes to be correlated with the receptor-binding regions. The results further strengthen the previously demonstrated therapeutic and diagnostic potential of the E317 antibody.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An estimated 5% of new protein structures solved today represent a new Pfam family

This study uses the Pfam database to show that the sequence redundancy of protein structures deposited in the PDB is increasing. The possible reasons behind this trend are discussed. High-resolution structural knowledge is key to understanding how proteins function at the molecular level. The number of entries in the Protein Data Bank (PDB), the repository of all publicly available protein structures, continues to increase, with more than 8000 structures released in 2012 alone. The authors of this article have studied how structural coverage of the protein-sequence space has changed over time by monitoring the number of Pfam families that acquired their first representative structure each year from 1976 to 2012. Twenty years ago, for every 100 new PDB entries released, an estimated 20 Pfam families acquired their first structure. By 2012, this decreased to only about five families per 100 structures. The reasons behind the slower pace at which previously uncharacterized families are being structurally covered were investigated. It was found that although more than 50% of current Pfam families are still without a structural representative, this set is enriched in families that are small, functionally uncharacterized or rich in problem features such as intrinsically disordered and transmembrane regions. While these are important constraints, the reasons why it may not yet be time to give up the pursuit of a targeted but more comprehensive structural coverage of the protein-sequence space are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kensor: Coordinated Intelligence from Co-Located Sensors

Internet of Things (IoT) is becoming more pervasive in many installations, including homes, manufacturing plants, and industrial facilities of all kinds. The data that IoT produces is a reflection of usual behavior such as daily routines and scheduled tasks, but also from unexpected behavior due to unintentional or undesirable abnormalities. Here, we focus on achieving coordinated intelligence about normal and abnormal phenomena from multiple sensors that are geographically colocated in close proximity, monitoring and controlling a set of co-located devices. Given a set of co-located sensors, we seek an intelligent approach that would automatically determine the “normal” patterns of behaviors among the correlated sensors. After normal behavior is extracted, later monitoring should detect any deviant variations over time. An example application is an entry monitoring and alert system for facilities such as nuclear reactors, where badge readers, door locks, lights, weight trackers and other co-located sensors at the entry point are collectively tracked. To address this problem, we identify the possible solution approach that can be used to solve its different variants. The implemented model is developed as a combination of rules and Markov Chain methods.

Kotevska, Olivera↗

Trigger-based Incremental Data Processing with Unified Sync and Async Model

In recent years, more and more applications in the cloud have needs to process large-scale on-line datasets, which evolve over time as new entries are added and existing entries are modified. Several programming frameworks, such as Percolator and Oolong, are proposed for such incremental data processing and can achieve efficient processing with an event-driven abstraction. However, these frameworks are inherently asynchronous, leaving the heavy burden of managing synchronization to applications' developers, which further significantly restricts their usabilities. In this study, we propose a trigger-based incremental computing framework in the cloud, called Domino, with both synchronous and asynchronous mechanisms to coordinate parallel triggers. With this new framework, both synchronous and asynchronous applications can be seamlessly developed. Use cases and extensive evaluation results confirm that it can deliver sufficient performance, and also is easy to use for incremental applications in large-scale distributed computing.

97 MATHEMATICS AND COMPUTING↗

A Software Developer’s Guide to Informal Evaluation of Visual Analytics Environments Using VAST Challenge Information

The VAST Challenge has been a popular venue for academic and industry participants for over ten years. Many participants comment that the majority of their time in preparing VAST Challenge entries is discovering elements in their software environments that need to be redesigned in order to solve the given task. Fortunately, there is no need to wait until the VAST Challenge is announced to test out software systems. The Visual Analytics Benchmark Repository contains all past VAST Challenge tasks, data, solutions and submissions. This paper details the various types of evaluations that may be conducted using the Repository information. In this paper we describe how developers can do informal evaluations of various aspects of their visual analytics environments using VAST Challenge information. Aspects that can be evaluated include the appropriateness of the software for various tasks, the various data types and formats that can be accommodated, the effectiveness and efficiency of the process supported by the software, and the intuitiveness of the visualizations and interactions. Researchers can compare their visualizations and interactions to those submitted to determine novelty. In addition, the paper provides pointers to various guidelines that software teams can use to evaluate the usability of their software. While these evaluations are not a replacement for formal evaluation methods, this information can be extremely useful during the development of visual analytics environments.

evaluation↗

A new upper bound for the growth factor in Gaussian elimination with complete pivoting

Abstract The growth factor in Gaussian elimination measures how large the entries of an LU factorization can be relative to the entries of the original matrix. It is a key parameter in error estimates, and one of the most fundamental topics in numerical analysis. We produce an upper bound of for the growth factor in Gaussian elimination with complete pivoting — the first improvement upon Wilkinson's original 1961 bound of .

Bisain, Ankit [Department of Mathematics Massachus↗

DESIGN AND TESTING OF DIMES CARBON ABLATION RODS IN THE DIII-D TOKAMAK

We present the design of ATJ graphite rods developed for ablation experiments under high heat flux (up to 50 MW/m2) in the lower divertor of the DIII-D tokamak, a magnetic plasma confinement device. This work is motivated by the need to test ablation models relevant to carbon-based thermal shields used in high-speed spacecraft atmospheric entries, where the heat fluxes encountered can be comparable to those achieved in the DIII-D divertor plasma. Several different designs for the flowfacing side of the rod are analyzed, including "sharp nose," "blunt," and "concave". The last shape is studied for its potential to lower heat fluxes at the rod surface by increased radiation from trapped neutrals and reduced parallel plasma pressure. We also analyze the possibility of applying a thin (approximately 30 microns) layer of silicon carbide (SiC) to the exposed part of several carbon ablation rods to benchmark its erosion calculations and lifetime predictions. Such calculations are of interest as SiC represents a promising material for both thermal protection systems (TPS) and a fusion plasma-facing material (PFM). Preliminary results from the DIII-D rod ablation experiments are also discussed.

Orlov, Dmitri M.↗

Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-524: Web-Based Radiation Oncology Incident Reporting and Learning System (ROIRLS)

Purpose: Describe a Web-based Radiation Oncology Incident Reporting and Learning system that has the potential to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: The VA National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and near miss data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. Software used for this program is deployed on the VAs intranet as a Website. All data entry forms (adverse event or near miss reports, work product reports) utilize standard causal, RT process step taxonomies and data dictionaries defined in AAPM and ASTRO reports on error reporting (AAPM Work Group Report on Prevention of Errors and ASTROs safety is no accident report). All reported incidents are investigated by the radiation oncology domain experts. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The operational workflow is similar to that of the Aviation Safety Reporting System. This system is also synergistic with ROSIS and SAFRON. Results: The ROIRLS facilitates the collection of data that help in tracking adverse events and near misses and develop new interventions to prevent such incidents. The ROIRLS electronic infrastructure is fully integrated with each registered facility profile data thus minimizing key strokes and multiple entries by the event reporters. Conclusions: OIRLS is expected to improve the quality and safety of a broad spectrum of radiation therapy patients treated in the VA and fulfills our goal of Effecting Quality While Treating Safely The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations Inc. and is deployed on the VA intranet as a Website. The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations Inc. and is deployed on the VA intranet as a Website.

60 APPLIED LIFE SCIENCES↗

SU-E-T-544: A Radiation Oncology-Specific Multi-Institutional Federated Database: Initial Implementation

Purpose: To implement a common database structure and user-friendly web-browser based data collection tools across several medical institutions to better support evidence-based clinical decision making and comparative effectiveness research through shared outcomes data. Methods: A consortium of four academic medical centers agreed to implement a federated database, known as Oncospace. Initial implementation has addressed issues of differences between institutions in workflow and types and breadth of structured information captured. This requires coordination of data collection from departmental oncology information systems (OIS), treatment planning systems, and hospital electronic medical records in order to include as much as possible the multi-disciplinary clinical data associated with a patients care. Results: The original database schema was well-designed and required only minor changes to meet institution-specific data requirements. Mobile browser interfaces for data entry and review for both the OIS and the Oncospace database were tailored for the workflow of individual institutions. Federation of database queries--the ultimate goal of the project--was tested using artificial patient data. The tests serve as proof-of-principle that the system as a whole--from data collection and entry to providing responses to research queries of the federated database--was viable. The resolution of inter-institutional use of patient data for research is still not completed. Conclusions: The migration from unstructured data mainly in the form of notes and documents to searchable, structured data is difficult. Making the transition requires cooperation of many groups within the department and can be greatly facilitated by using the structured data to improve clinical processes and workflow. The original database schema design is critical to providing enough flexibility for multi-institutional use to improve each institution s ability to study outcomes, determine best practices, and support research. The project has demonstrated the feasibility of deploying a federated database environment for research purposes to multiple institutions.

60 APPLIED LIFE SCIENCES↗

SU-E-T-572: Beam Characteristics and Treatment Planning Commissioning for a New Proton Therapy Unit

Purpose: A single-room proton system, the Mevion S250, was introduced into the arena of proton radiotherapy by Mevion Medical Systems. The first unit was installed and operates at the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital. The objective of this abstract is to report the system's beam characteristics and Eclipse commissioning. Methods: Commissioning data were acquired for modelling longitudinal fluence, virtual source position, effective source position, source size and Bragg peaks in Eclipse. Stoichiometric CT calibration was generated via ICRU44 human. Spread-out Bragg peaks (SOBP) were measured with Parallel Plate Chamber and profiles with solid state detector for model validation. Heterogeneity effects were measured with bone and lung inserts in the beam line. RT dose was computed in a virtual water phantom, and exported from Eclipse to compare with measurements at various depths and axis. SOBPs were fine-tuned with partial shining correction and entry correction to match measurements. Output factor was measured for each individual field with an ADCL ion chamber in a water tank and fitted to a polynomial function to cross-check the monitor unit verification. Results: Ranges of all 24 options were measured within ±1mm tolerance. Modulations met a ±1mm or ±2% tolerance. SOBP flatness met a ±3% tolerance. Distal fall off (80%-20%) were measured between 6mm and 7mm for all options. Virtual source positions varied between 177cm and 195cm, decreasing with field size and range. SOBP generated by Eclipse agreed with measurements within ±3% in the entry region, and ±1%/±1mm in other regions. Sanity check for output achieved 5% accuracy in 98% of cases. Conclusion: The commissioning of the first Mevions S250 proton therapy system met specifications. The unit has been put in clinical operation since 12/17/2013.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-01: A System for Automatically Calculating Organ and Effective Dose for Fluoroscopically-Guided Procedures

Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to read data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

SU-F-P-10: A Web-Based Radiation Safety Relational Database Module for Regulatory Compliance

Purpose: Maintaining compliance with Radioactive Materials Licenses is inherently a time-consuming task requiring focus and attention to detail. Staff tasked with these responsibilities, such as the Radiation Safety Officer and associated personnel must retain disparate records for eventual placement into one or more annual reports. Entering results and records in a relational database using a web browser as the interface, and storing that data in a cloud-based storage site, removes procedural barriers. The data becomes more adaptable for mining and sharing. Methods: Web-based code was written utilizing the web framework Django, written in Python. Additionally, the application utilizes JavaScript for front-end interaction, SQL, HTML and CSS. Quality assurance code testing is performed in a sequential style, and new code is only added after the successful testing of the previous goals. Separate sections of the module include data entry and analysis for audits, surveys, quality management, and continuous quality improvement. Data elements can be adapted for quarterly and annual reporting, and for immediate notification of user determined alarm settings. Results: Current advances are focusing on user interface issues, and determining the simplest manner by which to teach the user to build query forms. One solution has been to prepare library documents that a user can select or edit in place of creation a new document. Forms are being developed based upon Nuclear Regulatory Commission federal code, and will be expanded to include State Regulations. Conclusion: Establishing a secure website to act as the portal for data entry, storage and manipulation can lead to added efficiencies for a Radiation Safety Program. Access to multiple databases can lead to mining for big data programs, and for determining safety issues before they occur. Overcoming web programming challenges, a category that includes mathematical handling, is providing challenges that are being overcome.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-91: Sparing Lung Function in Treatment Planning Using Dual Energy Tomography

Purpose: To propose an alternate treatment plan that minimizes the dose to the functional lung tissues. In clinical situation, the evaluation of the lung functionality is typically derived from perfusion scintigraphy. However, such technique has spatial and temporal resolutions generally inferior to those of a CT scan. Alternatively, it is possible to evaluate pulmonary function by analysing the iodine concentration determined via contrast-enhanced dual energy CT (DECT) scan. Methods: Five lung cancer patients underwent a scintigraphy and a contrast-enhanced DECT scan (SOMATOM Definition Flash, Siemens). The iodine concentration was evaluated using the two-material decomposition method to produce a functional map of the lung. The validation of the approach is realized by comparison between the differential function computed by DECT and scintigraphy. The functional map is then used to redefine the V5 (volume of the organ that received more than 5 Gy during a radiotherapy treatment) to a novel functional parameter, the V5f. The V5f, that uses a volume weighted by its function level, can assist in evaluating optimal beam entry points for a specific treatment plan. Results: The results show that the differential functions obtained by scintigraphy and DECT are in good agreement with a mean difference of 6%. In specific cases, we are able to visually correlate low iodine concentration with abnormal pulmonary lung or cancerous tumors. The comparison between V5f and V5 has shown that some entry points can be better exploited and that new ones are now accessible, 2.34 times more in average, without increasing the V5f - thus allowing easier optimization of other planning objectives. Conclusion: In addition to the high-resolution DECT images, the iodine map provides local information used to detect potential functional heterogeneities in the 3D space. We propose that this information be used to calculate new functional dose parameters such as the V5f. The presenting author, Andreanne Lapointe, received a canadian scholarship from MITACS. Part of the funding is from the compagny Siemens.

60 APPLIED LIFE SCIENCES↗

Crystal Structure of Human Adenovirus at 3.5 Å Resolution

Rational development of adenovirus vectors for therapeutic gene transfer is hampered by the lack of accurate structural information. Here, we report the x-ray structure at 3.5 angstrom resolution of the 150-megadalton adenovirus capsid containing nearly 1 million amino acids. We describe interactions between the major capsid protein (hexon) and several accessory molecules that stabilize the capsid. The virus structure also reveals an altered association between the penton base and the trimeric fiber protein, perhaps reflecting an early event in cell entry. The high-resolution structure provides a substantial advance toward understanding the assembly and cell entry mechanisms of a large double-stranded DNA virus and provides new opportunities for improving adenovirus-mediated gene transfer.

36 MATERIALS SCIENCE↗

Quantification of Hepatitis C Virus Cell-to-Cell Spread Using a Stochastic Modeling Approach

It has been proposed that viral cell-to-cell transmission plays a role in establishing and maintaining chronic infections. Thus, understanding the mechanisms and kinetics of cell-to-cell spread is fundamental to elucidating the dynamics of infection and may provide insight into factors that determine chronicity. Because hepatitis C virus (HCV) spreads from cell to cell and has a chronicity rate of up to 80% in exposed individuals, we examined the dynamics of HCV cell-to-cell spread in vitro and quantified the effect of inhibiting individual host factors. Using a multidisciplinary approach, we performed HCV spread assays and assessed the appropriateness of different stochastic models for describing HCV focus expansion. To evaluate the effect of blocking specific host cell factors on HCV cell-to-cell transmission, assays were performed in the presence of blocking antibodies and/or small-molecule inhibitors targeting different cellular HCV entry factors. In all experiments, HCV-positive cells were identified by immunohistochemical staining and the number of HCV-positive cells per focus was assessed to determine focus size. We found that HCV focus expansion can best be explained by mathematical models assuming focus size-dependent growth. Consistent with previous reports suggesting that some factors impact HCV cell-to-cell spread to different extents, modeling results estimate a hierarchy of efficacies for blocking HCV cell-to-cell spread when targeting different host factors (e.g., CLDN1 > NPC1L1 > TfR1). This approach can be adapted to describe focus expansion dynamics under a variety of experimental conditions as a means to quantify cell-to-cell transmission and assess the impact of cellular factors, viral factors, and antivirals. IMPORTANCE. The ability of viruses to efficiently spread by direct cell-to-cell transmission is thought to play an important role in the establishment and maintenance of viral persistence. As such, elucidating the dynamics of cell-to-cell spread and quantifying the effect of blocking the factors involved has important implications for the design of potent antiviral strategies and controlling viral escape. Mathematical modeling has been widely used to understand HCV infection dynamics and treatment response; however, these models typically assume only cell-free virus infection mechanisms. Here, we used stochastic models describing focus expansion as a means to understand and quantify the dynamics of HCV cell-to-cell spread in vitro and determined the degree to which cell-to-cell spread is reduced when individual HCV entry factors are blocked. Finally, the results demonstrate the ability of this approach to recapitulate and quantify cell-to-cell transmission, as well as the impact of specific factors and potential antivirals.

59 BASIC BIOLOGICAL SCIENCES↗

Mutagenesis of Human Cytomegalovirus Glycoprotein L Disproportionately Disrupts gH/gL/gO over gH/gL/pUL128-131

Herein, cell-free and cell-to-cell spread of herpesviruses involves a core fusion apparatus comprised of the fusion protein glycoprotein B (gB) and the regulatory factor gH/gL. The human cytomegalovirus (HCMV) gH/gL/gO and gH/gL/pUL128-131 facilitate spread in different cell types. The gO and pUL128-131 components bind distinct receptors, but how the gH/gL portions of the complexes functionally compare is not understood. We previously characterized a panel of gL mutants by transient expression and showed that many were impaired for gH/gL-gB-dependent cell-cell fusion but were still able to form gH/gL/pUL128-131 and induce receptor interference. Here, the gL mutants were engineered into the HCMV BAC clones TB40/e-BAC4 (TB), TR, and Merlin (ME), which differ in their utilization of the two complexes for entry and spread. Several of the gL mutations disproportionately impacted gH/gL/gO-dependent entry and spread over gH/gL/pUL128-131 processes. The effects of some mutants could be explained by impaired gH/gL/gO assembly, but other mutants impacted gH/gL/gO function. Soluble gH/gL/gO containing the L201 mutant failed to block HCMV infection despite unimpaired binding to PDGFRα, indicating the existence of other important gH/gL/gO receptors. Another mutant (L139) enhanced the gH/gL/gO-dependent cell-free spread of TR, suggesting a “hyperactive” gH/gL/gO. Recently published crystallography and cryo-electron microscopy studies suggest structural conservation of the gH/gL underlying gH/gL/gO and gH/gL/pUL128-131. However, our data suggest important differences in the gH/gL of the two complexes and support a model in which gH/gL/gO can provide an activation signal for gB.

59 BASIC BIOLOGICAL SCIENCES↗