Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric sector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Viability of Vehicles Utilizing On-Board CO 2 Capture

Although battery electric and hydrogen fuel cell vehicles hold great promise for mitigating CO 2 emissions, there are still unaddressed sectors for electrified transport, e.g., the heavy-duty and long-range global shipping industry. In this Viewpoint, we examine the viability of CO 2 -neutral transportation using hydrocarbon or alcohol fuels, in which the CO 2 product is captured on-board the vehicle. This approach takes advantage of the unparalleled energy density of carbon-based fuels as needed for these energy-intensive applications. Here, a concept is developed considering the power technologies, infrastructure, and fuels required. Storage volume and mass requirements are calculated for a wide range of vehicle types and compared with those for other CO 2 -neutral options, namely hydrogen fuel cell and battery electric vehicles, and research and development needs to implement this technology are discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Subsonic Single Aft Engine Narrowbody (SUSAN) Freighter Concept and Market Analysis

The dedicated air cargo and freight market has the potential to be a critical early pathway for emerging technologies in low to zero emission propulsion. This study analyzes the cargo aviation market to understand current market trends and future market viability of a mid-sized all-electric or hybrid-electric concept aircraft. While cargo aviation’s overall emissions footprint is small relative to commercial passenger aviation, it remains an important and challenging transportation sector to decarbonize. Past research has focused on small, less than 19-seat electrified aircraft propulsion concepts that could serve both passenger and air cargo markets This study extends the electrified market space into larger aircraft classes, considering if a purpose-built large hybrid electric turboprop freighter can compete in the market currently served primarily by conversion narrowbody freighters. Specifically, this paper focuses on the mid-sized cargo market with payload ranges of 40,000-50,000lbs, and an all-electric range potential up to 750 miles. The concept aircraft is based on a 4-engine turboprop configuration, with mounted wing battery packs and an aft cargo door to allow for standardized palletization. The market analysis indicates broad market coverage with 73% of the existing mid-sized cargo network within the range of 750 miles. A breakeven analysis of operating and capital costs shows potential for market competition, however, additional energy and acquisition cost savings from the concept aircraft are needed. Evidence from the breakeven analysis also points to higher rates of aircraft utilization being a critical path to lowering costs and increasing cost effectiveness.

Jacob M. Wishart↗

Hybrid Electric Turboprop Commercial Freighter (HETCOF) Market Study

The dedicated air cargo and freight market has the potential to be a critical early pathway for emerging technologies in low to zero emission propulsion. This study analyzes the cargo aviation market to understand current market trends and future market viability of a mid-sized all-electric or hybrid-electric concept aircraft. While cargo aviation’s overall emissions footprint is small relative to commercial passenger aviation, it remains an important and challenging transportation sector to decarbonize. Past research has focused on small, less than 19-seat electrified aircraft propulsion concepts that could serve both passenger and air cargo markets. This study extends the electrified market space into larger aircraft classes, considering if a purpose-built large hybrid electric turboprop freighter can compete in the market currently served primarily by conversion narrowbody freighters. Specifically, this paper focuses on the mid-sized cargo market with payload ranges of 40,000-50,000lbs, and an all-electric range potential up to 750 miles. The concept aircraft is based on a 4-engine turboprop configuration, with wing mounted battery packs and an aft cargo door to allow for standardized palletization. The market analysis indicates broad market coverage with 73% of the existing mid-sized cargo network within the range of 750 miles. A breakeven analysis of operating and capital costs shows potential for market competition; however, this would require additional energy and acquisition cost savings from the concept aircraft. Evidence from the breakeven analysis also points to higher rates of aircraft utilization being a critical path to lowering costs and increasing cost effectiveness.

Hybrid Electric↗

Electric-Field De-Wetting for Enhanced Drying

Drying processes are one of the most energy intensive operations. Drying accounts for anywhere from 12 to 20% of the energy consumption in the industrial sector. While many different drying processes and thus technologies exist and each is appropriate for particular applications, convective heated-air dryers account for about 85% of all industrial dryers, where air is heated by the combustion of fossil fuels prior to being forced through the product. The electric-field dewetting concept evaluated has the potential to increase heat pumping efficiency by 30% assuming a typical sensible heat ratio of 70%. At full deployment, this can reduce drying energy by 25%. Further, the technology can benefit the performance of air-source heat pumps in general and broaden their application base resulting in greater energy reductions.

42 ENGINEERING↗

Fluctuations and turbulence in an electric field Bumpy Torus plasma

Fluctuation characteristics of plasma number density and electrostatic potential below the ion plasma and ion cyclotron frequencies in an electric field Bumpy Torus plasma were investigated experimentally, using digitally implemented spectral analysis techniques. The toroidal plasma was biased to high potentials by applying positive or negative voltage to electrodes located in the midplanes of two sectors of the toroidal array. The plasma was observed to be biased to 80 or 90% of the potential on the midplane electrodes, regardless of polarity. The radial electric field exceeded 1 kV/cm at the plasma boundary and penetrated inward to at least one-half of the plasma radius. When the imposed radial electric fields reached values characteristic of the experiment, the E/B drift velocities were comparable to the particle thermal velocities. The amplitude statistics of both the density and the potential fluctuations were found to be Gaussian for the most part, with near-zero skewness and a kurtosis of about 3.0. The spectral index of the density and potential fluctuations ranged from 2 to 6. The higher frequency components were found to propagate faster than the E/B drift velocity, which is the characteristic speed of the lower-frequency components.

Roth, J. R.↗

Valuing Resilience for Microgrids: Challenges, Innovative Approaches, and State Needs

The United States depends on the delivery of reliable, affordable, clean, and safe electricity. Electric utilities invest billions of dollars each year in generation, transmission, and distribution assets to meet this need. However, experiences with recent natural disasters of increasing frequency and duration demonstrate the shortcomings of this approach in the face of modern threats. Further, as customers rely on electricity for a broader range of important needs, such as transportation, as well as critical life-saving services and mission critical facilities such as water treatment, medical care, shelters, telecommunications, and more, the need to minimize the likelihood and impacts of outages grows. Against this backdrop, resilience has emerged as a key consideration to guide electricity spending, whether from utilities, customers, or taxpayers. Although reliability has been defined and measured for decades with broadly accepted metrics that measure how many customers lose power and at what frequency and duration, resilience considers the electricity system’s response to a disruption and its subsequent impacts on customers. Developing tools and methods to accurately assess the costs and benefits of resilience investments is a critical step toward the goal of mitigating the impacts of outages on customers and society. Today, electric system resilience is largely treated as an externality due to challenges estimating the costs of long-duration outages, impacts of outages on society, and increasing reliance on electricity for a growing set of interdependent services. These interdependencies include the water, wastewater, telecommunications, natural gas, and health sectors. Without knowing how much a given resilience investment will benefit customers or society more broadly, investors, policymakers, and regulators are less likely to make or approve such investments, and less able to prioritize those investments. State Energy Offices and public utility commissions (PUCs) lead the development of state-level energy policy and utility regulation, respectively, and each has interests in encouraging appropriate public and private investments in resilience. To this end, the National Association of State Energy Officials (NASEO) and National Association of Regulatory Utility Commissioners (NARUC), with the support of the U.S. Department of Energy (DOE) Office of Electricity (OE), formed a joint Microgrids State Working Group to explore the costs and benefits of microgrids, barriers to broader deployment of microgrids to meet resilience and other objectives, and policy and regulatory strategies to optimize investments in resilience, including but not limited to microgrids. Although no universally accepted valuation tool for resilience exists, National Laboratories, utilities, researchers, and state and federal agencies have collaborated to develop, apply, and improve a number of approaches to quantify resilience, several of which are still in progress at the time this report is published. This report seeks to share these important advances by discussing current definitions of resilience (Section 1), how microgrids are defined and used to meet resilience objectives (Section 2), new approaches to valuing resilience (Section 3), steps State Energy Offices and PUCs have taken to further resilience valuation efforts (Section 4), and finally, considerations and suggested next steps for State Energy Offices and PUCs (Section 5). Relevant examples of specific microgrid projects and resilience valuation efforts are included throughout the report. While this report is written specifically for NASEO and NARUC members, it may be useful for utilities, local governments, and individual customers interested in improving the way public and private dollars are spent to achieve resilience outcomes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leverage demand-side policies for energy security

Energy security is a top priority for governments, companies, and households because energy systems and the critical functions that they support are threatened by disruptions from wars, pandemics, climate change, and other shocks (1). More often than not, governments rely on policies focused on energy supply to enhance energy security while generally ignoring demand-side possibilities. Further, the indicators traditionally used to measure energy security are also tilted toward the supply side; this fails to capture the full spectrum of vulnerability to energy crises. Energy security assessments need to reflect the wider benefits of security related interventions more accurately. To that end, we develop a systematic approach to measuring the energy security impacts of policy interventions that explicitly considers energy demand (buildings, transport, and industry). Here, we determine that demand-side actions outperform conventional supply-side approaches at making countries more resilient. Energy demand links more directly than supply to the satisfaction of critical social functions and human well-being that are at the core of energy security. Yet, demand-side perspectives tend to be neglected or underrepresented in analysis and policy debates on energy security. Factors that contribute to this supply-side bias include the traditional sectoral organization of industries and policy institutions along fuels (coal, oil, and gas) and energy forms (electric utilities) as well as the decentralized and multivaried activities characteristic of energy demand (from vehicles to household appliances to manufacturing and more), which leads to a multitude of actors and institutional fragmentation. The basic fundamentals of energy systems and markets, where demand and supply are intricately linked, have also not yet risen from vague awareness to a central organizing principle among policy-makers for structuring the energy security discourse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electric and magnetic fields in the high-latitude magnetosphere

The configuration of high-latitude electric and magnetic fields is reviewed. Various results suggest that high-latitude magnetic field lines from the outermost regions of the dayside magnetosphere converge toward a point near the noon meridian. Plasma flows, the midday cusp, and a dawn-dusk electric field across the polar cap are characterized. The electric fields associated with plasma flows produce Hall currents on the polar cap which vary with sector structure. Some evidence indicates that polar cap convection may reverse during intervals of strong northward interplanetary field. It is concluded that most observations are consistent with an open field magnetosphere model.

Fairfield, D. H.↗

Tread drum for animals

A device for exercising animals such as primates is described, which includes a cylindrical housing mounted for rotation about a horizontal axis of revolution and has a cylindrical treadway portion on which the animal treads while the drum is rotated by means of a motorized drive. The treadway portion of the drum includes an electrode structure with sectors being independently energizable by means of a commutator and source of potential so that an electrical shock station is created behind a running-in-place station on the moving treadway. In this manner, if the animal should fall behind its running-in-place station, it may be shocked by treading on the energized electrode structure. One end of the tread drum comprises a transparent wall for unobstructed viewing of the animal being exercised.

Howard, W. H.↗

HF radar observations of Pc 5 field line resonances in the midnight/early morning MLT sector

The technique of F region sounding by HF coherent radar is applied to the study of field line resonances equatorward of a region of shear flow in the early morning sector. The motions were predominantly in the geomagnetic east-west direction, indicating north-south electric fields. These oscillations had pronounced peaks in their latitudinal power distribution. For the pulsation at 1.95 mHz, a latitudinal phase shift of 180 deg was observed across the peaks in all the look directions of the radar, and a longitudinal wavelength corresponding to an m value of 3 was obtained. For the 2.6-mHz pulsation, the phase shifts across the peaks had a variation with a look direction that indicated a significant longitudinal as well as latitudinal variation; for this activity, an m value of about 16 is estimated. These features are interpreted in terms of the field line resonance theory, and the possible sources of the pulsation energy are discussed.

Ruohoniemi, J. M.↗

Deployment Feasibility Futures Analysis of Natural Gas Combined Cycle with Carbon Capture in Five U.S. Regions

A broad suite of technologies will be required to enable the United States to meet the current goal of a zero-carbon power sector by 2035, while continuing to provide the U.S. consumer with reliable, secure, stable, and affordable electricity. This study was conducted to evaluate the competitiveness of a natural gas combined cycle (NGCC) with carbon capture and storage (CCS) in five independent system operating areas, the PJM interconnection (PJM) regional transmission organization, Midcontinent Independent System Operator (MISO), Western Electricity Coordinating Council’s (WECC) Northwest Power Pool (NWPP) region, the Electric Reliability Council of Texas (ERCOT) and the SERC Reliability Corporation (SERC) in the 2030 to 2035 time horizon. The modeling and simulation efforts focused on determining the dispatch characteristics and the economic feasibility of constructing an NGCC plant with CCS in each of those regions. The analysis indicates that a NGCC system with CCS can be economically viable in the ERCOT and PJM regions. Additional revenue stream and/or capacity payments are required in MISO, NWPP, and SERC to enable successful commercial deployment of a NGCC with CCS.

Pickenpaugh, Gavin↗

The Modeling of Synfuel Production Process: ASPEN Model of FT production with electricity demand provided at LWR scale

Synfuels, or electro-fuels (e-fuels) have the unique potential to significantly reduce greenhouse gas (GHG) emissions across the transportation sector. This is especially true for applications with substantial payloads and daily miles traveled, such as long-haul heavy-duty vehicles, rail locomotives, marine vessels and aviation aircrafts that are challenging to directly electrify via battery or fuel cell powertrain technologies. Synfuels, or electro-diesel/electro-jet fuels, have similar properties with the incumbent petroleum fuels, compatible with current infrastructure but have much lower GHG emissions relative to the petroleum counterpart, because they utilize waste carbon dioxide (CO2) streams and green hydrogen (H2) sourced from electrolysis. To achieve substantial reductions in GHG emissions, electricity sources must be zero carbon or near-zero carbon, which is the case with solar, wind, hydro and nuclear power. Compared to the intermittency of solar, wind and hydro, nuclear energy provides a steady energy source. In addition, it’s advantageous for nuclear power to produce synfuels because it provides not only near-zero carbon electricity to displace grid electricity, but also near-zero carbon steam to displace carbon-intensive natural gas combustion for steam generation. The availability of electricity and steam also enables more efficient green hydrogen production by using high-temperature electrolysis. In this work, Argonne National Laboratory (ANL) models a synfuel production process via the Fischer- Tropsch (FT) reaction by using nuclear power to provide electricity and steam. In 2021, using ASPEN Plus software, ANL established a detailed process model of a stand-alone FT production facility, assuming feedstocks of pure CO2 and H2. This stand-alone model can be expanded to integrate H2 production from nuclear power via low-temperature and high-temperature electrolysis at light-water reactor (LWR) scale. This report summarizes the stand-alone ASPEN Plus model results with a detailed mass and energy analysis. Our modeled facility produces 351 MT/day (130,000 gal/day) of FT fuel (a mixture of naphtha, jet fuel, and diesel) by converting 223 MT/day of H2 and 2,387 MT/day of CO2. The FT fuel production energy efficiency is 58% and the carbon conversion efficiency (from CO2 to FT fuel) is 46%. The production of green hydrogen requires 390–470 MWe of electricity, which is compared with the capacity of an LWR plant. For the stand-alone FT process, the detailed energy demand (electricity and heat) is summarized in the table below. Based on the energy supply source and the required temperature, potential insertion points of nuclear energy are identified. Based on the potential nuclear energy utilization, this report discusses potential modification options for expanding the system boundary to integrate nuclear power use, for example on-site hydrogen production via water electrolysis. Modeling of the integrated system is conducted by closely working with ANL and Idaho National Laboratory (INL) collaborators to harmonize design parameters of nuclear plants and the FT production process.

Zang, Guiyan↗

Integration of Electric Power Infrastructure into the Drinking Water Shared Risk Framework: Prototype Development

An existing shared risk framework designed for assessing and comparing threat-based risks to water utilities is being extended to incorporate electric power. An important differentiating characteristic of this framework is the use of a system-centric rather than an asset-centric approach. This approach allows anonymous sharing of results and enables comparison of assessments across different utilities within an infrastructure sector. By allowing utility owners to compare their assessments with others, they can improve their self-assessments and identification of "unknown unknowns". This document provides an approach for extension of the framework to electric power, including treatment of dependencies and interdependencies. The systems, threats, and mathematical description of associated risks used in a prototype framework are provided. The method is extensible so that additional infrastructure sectors can be incorporated. Preliminary results for a proof of concept calculation are provided.

42 ENGINEERING↗

Important powertrain dynamics for developing models for control of connected and automated electrified vehicles

Connected and Automated Vehicles (CAV) technology presents significant opportunities for energy saving in the transportation sector. CAV technology forecasts vehicle and powertrain power needs under various terrain, ambient, and traffic conditions. Integration of the CAV technology in Hybrid Electric Vehicles (HEVs) provides the opportunity for optimal vehicle operation. Indeed, Hybrid Electric Vehicle powertrains present high degrees of flexibility and possibility for choosing optimum powertrain modes based on the predicted traction power needs. In modeling complex CAV powertrain dynamics, the modeler needs to consider short-time scale powertrain dynamics, such as engine transients, and hysteresis of mode-switching for a multi-mode HEV. Therefore, the powertrain dynamics essential for developing powertrain controllers for a class of connected HEVs is presented. To this end, control-oriented powertrain dynamic models for a test vehicle consisting of full electric, hybrid, and conventional engine operating modes are developed. The resulting powertrain model can forecast vehicle traction torque and energy consumption for the specified prediction horizon of the test vehicle. The model considers different operating modes and associated energy penalty terms for mode switching. Thus, the vehicle controller can determine the optimum powertrain mode, torque, and speed for forecasted vehicle operation via utilizing connectivity data. The powertrain model is validated against the experimental data and shows prediction error of less than 5% for predicting vehicle energy consumption. The model is used to create energy penalty maps that can be used for CAV control, for example fuel penalty map for engine torque changes (10–40 Nm) at each engine speed. The results of model-based optimization show optimum switching delays ranging from 0.4 to 1.4 s to avoid hysteresis in mode switching.

Engineering↗

A multi-level load shape clustering and disaggregation approach to characterize patterns of energy consumption behavior

This study presents representative electrical load shapes, disaggregated to the end-use level, for over 5000 customer clusters across California’s residential, commercial, industrial and agricultural sectors. We developed a novel, multi-level load shape clustering approach for residential and commercial sectors leveraging interval meter data for over 350,000 California utility customers collected as a part of the Phase 4 California Demand Response (DR) Potential Study. The clustering approach allowed us to identify typical consumption patterns and categorize customers based on their daily load shape displayed throughout the year. For example, we were able to identify customers with particular energy technologies such as electric vehicles and rooftop solar, as well as building occupancy types such as restaurants, grocery stores and even unoccupied buildings, based solely on whole-building interval data. We then combined the load shape-based clusters with other customer information including building type, climate, geographical area, total consumption and low-income status, to create a set of customer clusters based on both demographics and usage patterns. Total cluster electricity demand was then disaggregated into a wide variety of end-uses using weather normalization and other publicly available end-use load shape datasets. The resulting disaggregated cluster load shapes will be released in anonymized form as part of the Phase 4 DR Potential Study. They will have wide-ranging applications in energy research and policy analysis, including estimation of energy efficiency (EE) and DR potential on the end-use level, time-dependent valuation of EE savings, building stock modeling, and developing customer targeting strategies for EE and DR programs.

Murthy, Samanvitha↗

Strong 𝐶⁢𝑃 violation and large-𝑁 𝑐 spin-flavor symmetry

We revisit the contribution of the QCD $\bar{𝜃}$ term to the 𝐶⁢𝑃-violating pion-nucleon couplings and the nucleon electric dipole moment in a combined large-𝑁 𝑐 and chiral perturbation theory framework. In particular, we approach this issue through the emergent spin-flavor symmetry of the baryon sector at large but finite 𝑁 𝑐 . We obtain good agreement with previous analyses for the pion-nucleon couplings and show that the large-𝑁 𝑐 framework indicates that tree-level contributions to the electric dipole moment possibly play a dominant role. The spin-flavor symmetry also enables us to provide novel constraints on 𝐶⁢𝑃-violating pion-Δ couplings, as well as the Δ electric dipole moment and Δ⁢𝑁 transition moment.

Baryons↗

Sparticle spectroscopy and dark matter in a U(1) B-L extension of MSSM

We consider a class of SUSY models in which the MSSM gauge group is supplemented with a gauged U(1) B-L symmetry and a global U(1) R symmetry. This extension introduces only electrically neutral states, and the new SUSY partners effectively double the number of states in the neutralino sector that now includes a blino (from B - L) and singlino from a gauge singlet superfield. If the DM density is saturated by a LSP neutralino, the model yields quite a rich phenomenology depending on the DM composition. The LSP relic density constraint provides a lower bound on the stop and gluino masses of about 3 TeV and 4 TeV respectively, which is testable in the near future collider experiments such as HL-LHC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗