Single reflector interference spectrometer and drive system therefor

In a Fourier interference spectrometer of the doublepass retroreflector type, a single mirror is employed in the path of both split beams of an incoming ray to cause them to double back through separate retroreflectors. Changes in optical path length are achieved by linear displacement of both retroreflectors using a motor driven lead screw on one for large, low frequency changes, a moving-coil actuator on the other for smaller, mid-frequency changes and a piezoelectric actuator on one of these two for small, high frequency changes.

Schindler, R. A.↗

A use of regression analysis in acoustical diagnostics of gear drives

A study is presented of components of the vibration spectrum as the filtered first and second harmonics of the tooth frequency which permits information to be obtained on the physical characteristics of the vibration excitation process, and an approach to be made to comparison of models of the gearing. Regression analysis of two random processes has shown a strong dependence of the second harmonic on the first, and independence of the first from the second. The nature of change in the regression line, with change in loading moment, gives rise to the idea of a variable phase shift between the first and second harmonics.

Balitskiy, F. Y.↗

The aerodynamic design of a compressor-drive turbine for use in a 75 kw automotive engine

The design of a single stage axial-flow turbine with a tip diameter of 11.15 cm is presented. The design specifications are given, and the aerodynamic design procedure is described. The aerodynamic information includes the results of flow path, velocity diagram, and blade profile studies. Predicted off-design performance characteristics are also presented.

Roelke, R. J.↗

Cold-air investigation of a 3 1/2-stage fan-drive turbine with a stage loading factor of 4 designed for an integral lift engine. 1: Turbine design and performance of first stage

The design of the 3 1/2-stage turbine is described, and the cold-air performance of the first stage, modified for axial inlet conditions, is presented. The performance of the modified single-stage turbine and of two comtemporary high-stage-loading-factor turbines is compared with that estimated with a reference prediction method.

Whitney, W. J.↗

An interactive driving simulation for driver control and decision-making research

Display techniques and equations of motion for a relatively simple fixed base car simulation are described. The vehicle dynamics include simplified lateral (steering) and longitudinal (speed) degrees of freedom. Several simulator tasks are described which require a combination of operator control and decision making, including response to wind gust inputs, curved roads, traffic signal lights, and obstacles. Logic circuits are used to detect speeding, running red lights, and crashes. A variety of visual and auditory cues are used to give the driver appropriate performance feedback. The simulated equations of motion are reviewed and the technique for generating the line drawing CRT roadway display is discussed. On-line measurement capabilities and experimenter control features are presented, along with previous and current research results demonstrating simulation capabilities and applications.

Allen, R. W.↗

Concentric-tube differential drive

Remote manipulator consists essentially of gear shafts that are placed concentrically with bevel gears located at each joint. Teleoperator's advantages include light weight accessibility of parts, continuous rotation of joints, possibility of underwater use, and possibility of miniaturization.

Marlow, R. E.↗

Cold-air performance of a tip turbine designed to drive a lift fan. 1: Baseline performance

Full admission baseline performance was obtained for a 0.4 linear scale of the LF460 lift fan turbine over a range of speeds and pressure ratios without leakage air. These cold-air tests covered a range of speeds from 40 to 140 percent of design equivalent speed and a range of scroll inlet to diffuser exit static pressure ratios from 2.0 to 4.2. Results are presented in terms of specific work, torque, mass flow, efficiency, and total pressure drop.

Haas, J. E.↗

Cold air performance of a tip turbine designed to drive a lift fan. 2: Partial admission

Partial admission performance was obtained for a 0.4 linear scale version of the LF460 lift fan turbine over a range of speed from 40 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratio from 2.2 to 5.0. The investigation was conducted in two parts, with each part using a different side of the turbine scroll to simulate loss of a gas generator. Each side had an arc of admission of 180. Results are presented in terms of specific work, torque, mass flow, and efficiency.

Haas, J. E.↗

Cold-air investigation of a 31/2-stage fan-drive turbine with a stage loading factor of 4 designed for an integral lift engine. 2: Performance of 2-, 3- and 3 1/2-stage configurations

The stage work distribution among the three stages was very close to the design value. The specific work output-mass flow characteristics of the three stages were closely matched. The efficiency of the 3 1/2 stage turbine at design specific work output and design speed was within 0.008 of the estimated value, and this agreement was felt to demonstrate the adequacy of the prediction method in the high stage loading factor regime.

Whitney, W. J.↗

Acoustic performance of two 1.83-meter-diameter fans designed for a wind-tunnel drive system

A parametric study was made of the noise generated by two 1.83-m (6-ft) diameter fans operating up to a maximum pressure ratio of 1.03. One fan had 15 rotor blades, 23 stator blades, and a maximum rotational speed of 1200 rpm. The other fan had 9 rotor blades, 13 stator blades, and a maximum speed of 2,000 rpm. The fans were approximately 1/7-scale models of the 12.2-m (40-ft) diameter fans proposed for repowering the NASA-Ames 40- by 80 foot wind tunnel. The fans were operated individually in a 23.8-m (78-ft) long duct. Sound pressure levels in the duct were used to determine radiated acoustic power as fan speed, blade angle, and mass flow were varied. Results show that the low speed fan was slightly quieter than the high speed fan and, when scaled to full scale, would be 16 db quieter than the present wind tunnel fans. The fan noise varied directly with thrust regardless of whether thrust was varied by rotational speed or blade setting for the ranges studied.

Soderman, P. R.↗

Effect of digitally computed drives on performance of continuous linear systems

The dependence of the Bode response upon digital sample rate for first and second order linear continuous systems driven by a digital computer is derived. Open loop lead compensation introduced within the digital computer in order to increase the system bandwidth is also examined in terms of derived Bode responses. This introduction of lead terms within the digital computer is shown to be effective at operating frequencies below the Nyquist frequency. In most practical applications, empirical determination of these lead coefficients appears to be a sufficient compensation method.

Parrish, R. V.↗

Hybrid drive for motor vehicles with a preponderantly intermittent method of operation

A flywheel hybrid propulsion system is compared with a conventional propulsion system in a test vehicle under intermittent operation. An energy balance is presented for the conventional propulsion system. Results so far indicate especially high energy conversion of the gyro component under dynamic operation along with favorable internal combustion engine conditions.

Schreck, H.↗

Cold-air performance of a tip turbine designed to drive a lift fan

Performance was obtained over a range of speeds and pressure ratios for a 0.4 linear scale version of the LF460 lift fan turbine with the rotor radial tip clearance reduced to about 2.5 percent of the rotor blade height. These tests covered a range of speeds from 60 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratios from 2.6 to 4.2. Results are presented in terms of equivalent mass flow, equivalent torque, equivalent specific work, and efficiency.

Haas, J. E.↗

Cold-air performance of a tip turbine designed to drive a lift fan. 3: Effect of simulated fan leakage on turbine performance

Performance data were obtained experimentally for a 0.4 linear scale version of the LF460 lift fan turbine for a range of scroll inlet total to diffuser exit static pressure ratios at design equivalent speed with simulated fan leakage air. Tests were conducted for full and partial admission operation with three separate combinations of rotor inlet and rotor exit leakage air. Data were compared to the results obtained from previous investigations in which no leakage air was present. Results are presented in terms of mass flow, torque, and efficiency.

Haas, J. E.↗

Dynamics of drive systems for wind energy conversion

Calculations are performed to determine the dynamic effects of mechanical power transmission from the nacelle of a horizontal axis wind machine to the ground or to an intermediate level. It is found that resonances are likely at 2 or 4/REV, but they occur at low power only, and seem easily correctable. Large reductions are found in the harmonic torque inputs to the generator at powers near rated.

Martinez-Sanchez, M.↗