Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diode effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Dielectric Covered Planar Antennas at Submillimeter Wavelengths for Terahertz Imaging

Most optical systems require antennas with directive patterns. This means that the physical area of the antenna will be large in terms of the wavelength. When non-cooled systems are used, the losses of microstrip or coplanar waveguide lines impede the use of standard patch or slot antennas for a large number of elements in a phased array format. Traditionally, this problem has been solved by using silicon lenses. However, if an array of such highly directive antennas is to be used for imaging applications, the fabrication of many closely spaced lenses becomes a problem. Moreover, planar antennas are usually fed by microstrip or coplanar waveguides while the mixer or the detector elements (usually Schottky diodes) are coupled in a waveguide environment. The coupling between the antenna and the detector/ mixer can be a fabrication challenge in an imaging array at submillimeter wavelengths. Antennas excited by a waveguide (TE10) mode makes use of dielectric superlayers to increase the directivity. These antennas create a kind of Fabry- Perot cavity between the ground plane and the first layer of dielectric. In reality, the antenna operates as a leaky wave mode where a leaky wave pole propagates along the cavity while it radiates. Thanks to this pole, the directivity of a small antenna is considerably enhanced. The antenna consists of a waveguide feed, which can be coupled to a mixer or detector such as a Schottky diode via a standard probe design. The waveguide is loaded with a double-slot iris to perform an impedance match and to suppress undesired modes that can propagate on the cavity. On top of the slot there is an air cavity and on top, a small portion of a hemispherical lens. The fractional bandwidth of such antennas is around 10 percent, which is good enough for heterodyne imaging applications.The new geometry makes use of a silicon lens instead of dielectric quarter wavelength substrates. This design presents several advantages when used in the submillimeter-wave and terahertz bands: a) Antenna fabrication compatible with lithographic techniques. b) Much simpler fabrication of the lens. c) A simple quarter-wavelength matching layer of the lens will be more efficient if a smaller portion of the lens is used. d) The directivity is given by the lens diameter instead of the leaky pole (the bandwidth will not depend anymore on the directivity but just on the initial cavity). The feed is a standard waveguide, which is compatible with proven Schottky diode mixer/detector technologies. The development of such technology will benefit applications where submillimeter- wave heterodyne array designs are required. The main fields are national security, planetary exploration, and biomedicine. For national security, wideband submillimeter radars could be an effective tool for the standoff detection of hidden weapons or bombs concealed by clothing or packaging. In the field of planetary exploration, wideband submillimeter radars can be used as a spectrometer to detect trace concentrations of chemicals in atmospheres that are too cold to rely on thermal imaging techniques. In biomedicine, an imaging heterodyne system could be helpful in detecting skin diseases.

Chattopadhyay, Goutam↗

Water additives improve the efficiency of violet perovskite light-emitting diodes

High external quantum efficiencies (EQEs) have been achieved for blue, green, red, and near-infrared perovskite light-emitting diodes (PeLEDs), and their energy efficiencies are approaching the efficiencies of III-V-based LEDs. Beyond the visible regime, ultraviolet light offers great promise for many applications such as disinfection. However, PeLEDs demonstrate poor performance in the violet/ultraviolet region, with reports of violet PeLED performance hindered by poor thin-film quality. In this work, we improve the uniformity of perovskite films by adding water into the precursor solution to engineer the crystallization process of spin-coated 2D perovskites. The resulting improved film uniformity, coupled with the reduction in nanoplate size, reduces leakage current and promotes faster recombination rates. The fabricated PeLEDs deliver bright violet emission at 408 nm with a maximum external quantum efficiency of 0.41%, a 5-fold increase over control devices. Furthermore, this work demonstrates viable steps toward cost-effective, efficient ultraviolet PeLEDs.

36 MATERIALS SCIENCE↗

Kinetic Temperature and Electron Density Measurement in an Inductively Coupled Plasma Torch using Degenerate Four-Wave Mixing

Laser wave mixing is presented as an effective technique for spatially resolved kinetic temperature measurements in an atmospheric-pressure radio-frequency inductively-coupled plasma. Measurements are performed in a 1 kW, 27 MHz RF plasma using a continuous-wave, tunable 811.5-nm diode laser to excite the 4s(sup 3)P2 approaches 4p(sup 3)D3 argon transition. Kinetic temperature measurements are made at five radial steps from the center of the torch and at four different torch heights. The kinetic temperature is determined by measuring simultaneously the line shape of the sub-Doppler backward phase-conjugate degenerate four-wave mixing and the Doppler-broadened forward-scattering degenerate four-wave mixing. The temperature measurements result in a range of 3,500 to 14,000 K+/-150 K. Electron densities measured range from 6.1 (+/-0.3) x 10(exp 15)/cu cm to 10.1 (+/-0.3) x 10(exp 15)/cu cm. The experimental spectra are analyzed using a perturbative treatment of the backward phase-conjugate and forward-geometry wave-mixing theory. Stark width is determined from the collisional broadening measured in the phase-conjugate geometry. Electron density measurements are made based on the Stark width. The kinetic temperature of the plasma was found to be more than halved by adding deionized water through the nebulizer.

Schafer, Julia↗

Laser diode ignition activities at Sandia National Laboratories

The topics are presented in viewgraph form and include the following: ignition subsystems, enhanced safety, optical ordnance power densities, optical ignition factors, low energy optical ordnance program, absorptance of 2-(5-cyanotetrazolato) pentaaminecobalt(III) perchlorate (CP) near 800 nm, power dependence of doped CP, system operational electrical requirements, dopant concentration effects for different CP particle sizes, ZR/KCLO4 optical ignition thresholds, and electrostatic discharge testing.

Merson, John A.↗

Application of emerging monitoring techniques at the Illinois Basin – Decatur Project

The Illinois Basin – Decatur Project is a large-scale carbon capture and storage demonstration project located in Decatur, Illinois, USA. In this project, one million metric tons of carbon dioxide (CO 2 ) was captured from an ethanol production facility and successfully injected into a deep saline reservoir over a period of three years. The scale of this project presented an opportunity to explore emerging technologies for effective long-term monitoring of the carbon capture and storage site. This research documents the application of three emerging monitoring techniques: (1) a prototype “open-path” sensor, a method of continuously monitoring atmospheric CO 2 by applying tunable diode laser absorption spectroscopy to provide a warning system for personnel safety along pipelines and at wellheads; (2) the Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE), an automated system for measuring two-dimensional spatial distribution of atmospheric CO 2 concentrations; and (3) periodic aerial imagery, a method of documenting surface-vegetation dynamics to detect vegetative responses to CO 2 leaks. The objective of this work was to assess the advantages and limitations of these monitoring techniques and quantify their reliability over an extended deployment at an active industrial site. These results will aid in determining viability of long-term monitoring on a commercial scale.

42 ENGINEERING↗

X-band system performance of the very large array

The Very Large Array (VLA) is being equipped to receive telemetry from Voyager 2 during the Neptune encounter in 1989. Cryogenically cooled amplifiers are being installed on each of the 27 antennas. These amplifiers are currently a mix of field effect transistors (FETs) and high electron mobility transistors (HEMTs) and exhibit zenith system temperatures that range from 30 to 52 K. The system temperatures and aperture efficiencies determined during the past year are summarized. The nominal values of the noise diode calibration are compared with derived values made under the assumption of a uniform atmosphere over the array. Gain values are determined from observations of unresolved radio sources whose flux densities are well known. The tests suggest that the completed VLA will have a ratio of gain to system temperature that is approximately 4.4 dB above that of a single 64 m antenna of the Deep Space Network.

Ulvestad, J. S.↗

Tunable diode laser absorption sensor for temperature and velocity measurements of O2 in air flows

A fast and nonintrusive velocity and temperature diagnostic based on oxygen absorption is presented. The system uses a GaAlAs tunable diode laser, ramped and modulated in wavelength at high frequency. Detection is performed at twice the modulating frequency, leading to second harmonic absorption lineshapes. Velocity is inferred from the wavelength shift of the absorption line center due to the Doppler effect. Temperature is determined by comparing experimental and calculated lineshapes. Capabilities of the technique for studies of transient high-speed flows are demonstrated in shock tube experiments. Good agreement is obtained with predicted temperatures and velocities when pressure-induced shifts are accounted for.

Philippe, L. C.↗

Infrared laser spectroscopy of jet-cooled carbon clusters: structure of triplet C6

We report the first structural characterization of the triplet isomer of C6. Forty-one rovibrational/fine structure transitions in the nu 4(sigma u) antisymmetric stretch fundamental of the C6 cluster have been measured by diode laser absorption spectroscopy of a supersonic carbon cluster beam. The observed spectrum is characteristic of a centrosymmetric linear triplet state with cumulene-type bonding. The measured ground state rotational constant B0 = 0.048 479 (10)cm-1 and the effective bond length r(eff) = 1.2868 (1) angstroms are in good agreement with ab initio predictions for the linear triplet (3 sigma g-) state of C6.

Non-NASA Center↗

Metrology System for a Large, Somewhat Flexible Telescope

A proposed metrology system would be incorporated into a proposed telescope that would include focusing optics on a rigid bench connected via a deployable mast to another rigid bench holding a focal-plane array of photon counting photodetectors. Deformations of the deployable mast would give rise to optical misalignments that would alter the directions (and, hence, locations) of incidence of photons on the focal plane. The metrology system would measure the relative displacement of the focusing- optics bench and the focal-plane array bench. The measurement data would be used in post-processing of the digitized photodetector outputs to compensate for the mast-deformation-induced changes in the locations of incidence of photons on the focal plane, thereby making it possible to determine the original directions of incidence of photons with greater accuracy. The proposed metrology system is designed specifically for the Nuclear Spectroscopic Telescope Array (NuSTAR) a proposed spaceborne x-ray telescope. The basic principles of design and operation are also applicable to other large, somewhat flexible telescopes, both terrestrial and spaceborne. In the NuSTAR, the structural member connecting the optical bench and the photodetector array would be a 10-m-long deployable mast, and there is a requirement to keep errors in measured directions of incidence of photons below 10 arc seconds (3 sigma). The proposed system would include three diode lasers that would be mounted on the focusing-optics bench. For clarity, only one laser is shown in the figure, which is a greatly simplified schematic diagram of the system. Each laser would be aimed at a position-sensitive photodiode that would be mounted on the detector bench alongside the aforementioned telescope photodetector array. The diode lasers would operate at a wavelength of 830 nm, each at a power of 200 mW. Each laser beam would be focused to a spot of .1-mm diameter on the corresponding position-sensitive photodiode. To reduce the effect of sunlight on the measurements, a one-stage light baffle and an 830-nm transmission filter of 10-nm bandwidth would be placed in front of the position- sensitive photodiode. For each metrology reading, the output of the position-sensitive detector would be sampled and digitized twice: once with the lasers turned on, then once with the lasers turned off. The data from these two sets of samples would be subtracted from each other to further reduce the effects of sun glints or other background light sources.

Liebe, Carl Christian↗

Using Light to Treat Mucositis and Help Wounds Heal

A continuing program of research and development is focusing on the use of controlled illumination by light-emitting diodes (LEDs) to treat mucositis and to accelerate healing of wounds. The basic idea is to illuminate the affected area of a patient with light of an intensity, duration, and wavelength (or combination of wavelengths) chosen to produce a therapeutic effect while generating only a minimal amount of heat. This method of treatment was originally intended for treating the mucositis that is a common complication of chemotherapy and radiation therapy for cancer. It is now also under consideration as a means to accelerate the healing of wounds and possibly also to treat exposure to chemical and radioactive warfare agents. Radiation therapy and many chemotherapeutic drugs often damage the mucosal linings of the mouth and gastrointestinal tract, leading to mouth ulcers (oral mucositis), nausea, and diarrhea. Hyperbaric-oxygen therapy is currently the standard of care for ischemic, hypoxic, infected, and otherwise slowlyhealing problem wounds, including those of oral mucositis. Hyperbaric-oxygen therapy increases such cellular activities as collagen production and angiogenesis, leading to an increased rate of healing. Biostimulation by use of laser light has also been found to be effective in treating mucositis. For hyperbaricoxygen treatment, a patient must remain inside a hyperbaric chamber for an extended time. Laser treatment is limited by laser-wavelength capabilities and by narrowness of laser beams, and usually entails the generation of significant amounts of heat.

Ignatius, Robert W.↗

Polarization/Spatial Combining of Laser-Diode Pump Beams

A breadboard version of an optical beam combiner is depicted which make it possible to use the outputs of any or all of four multimode laser diodes to pump a non-planar ring oscillator (NPRO) laser. The output of each laser diode has a single-mode profile in the meridional plane containing an axis denoted the 'fast' axis and a narrower multimode profile in the orthogonal meridional plane, which contains an axis denoted the 'slow' axis and a narrower multimode profile in the orthogonal meridional plane, which contains an axis denoted the 'slow' axis. One of the purposes served by the beam-combining optics is to reduce the fast-axis numerical aperture (NA) of the laser-diode output to match the NA of the optical fiber. Along the slow axis, the unmodified laser-diode NA is already well matched to the fiber optic NA, so no further slow-axis beam shaping is needed. In this beam combiner, the laser-diode outputs are collimated by aspherical lenses, then half-wave plates and polarizing beam splitters are used to combine the four collimated beams into two beams. Spatial combination of the two beams and coupling into the optical fiber is effected by use of anamorphic prisms, mirrors, and a focusing lens. The anamorphic prisms are critical elements in the NA-matching scheme, in that they reduce the fast-axis beam width to 1/6 of its original values. Inasmuch as no slow-axis beam shaping is needed, the collimating and focusing lenses are matched for 1:1 iumaging. Because these lenses are well corrected for infinite conjugates the combiner offers diffraction-limited performance along both the fast and slow axes.

Gelsinger, Paul↗

The C9 cluster - Structure and infrared frequencies

A structural characterization is presented for C9, the largest cluster predicted to have a linear ground state. IR laser diode absorption spectroscopy of a supersonic carbon jet is used to measure 51 lines of the nu6 (sigma u) antisymmetric stretch fundamental transition within the linear 1Sigma(g)+ ground electronic state of C9. The measured ground state rotational constant suggests an effective C-C bond length which is in good agreement with ab initio theory and consistent with cumulenic bonding in this cluster.

Heath, J. R.↗

Efficient energy extraction from a diode-pumped Q-switched Tm,Ho:YLiF4 laser

The operation of a diode-laser pumped thulium, holmium yttrium-lithium-fluoride laser (Tm,Ho:YLF) in Q-switched mode is reported. Output energies of 200 microjoules in pulses of 22 ns duration are recorded at Q-switch frequencies commensurate with an effective upper laser level lifetime of 6 ms. This lifetime is appreciably longer than that observed in other hosts permitting stored energy extraction of 64 percent, close to the projected maximum performance from these materials.

Mcguckin, B. T.↗

Space Qualification of Laser Diode Arrays

Laser instruments have great potential in enabling a new generation of remote-sensing scientific instruments. NASA s desire to employ laser instruments aboard satellites, imposes stringent reliability requirements under severe conditions. As a result of these requirements, NASA has a research program to understand, quantify and reduce the risk of failure to these instruments when deployed on satellites. Most of NASA s proposed laser missions have base-lined diode-pumped Nd:YAG lasers that generally use quasi-constant wave (QCW), 808 nm Laser Diode Arrays (LDAs). Our group has an on-going test program to measure the performance of these LDAs when operated in conditions replicating launch and orbit. In this paper, we report on the results of tests designed to measure the effect of vibration loads simulating launch into space and the radiation environment encountered on orbit. Our primary objective is to quantify the performance of the LDAs in conditions replicating those of a satellite instrument, determine their limitations and strengths which will enable better and more robust designs. To this end we have developed a systematic testing strategy to quantify the effect of environmental stresses on the optical and electrical properties of the LDA.

Troupaki, Elisavet↗

Antimicrobial Resources for Disinfection of Potable Water Systems for Future Spacecraft

As human exploration adventures beyond low earth orbit, life support systems will require more innovation and research to become self-sustaining and durable. One major concern about future space travel is the ability to store and decontaminate water for consumption and hygiene. This project explores materials and technologies for possible use in future water systems without requiring point-of-use (POU) filtering or chemical additives such as iodine or silver that require multiple doses to remain effective. This experimentation tested the efficacy of a variety of antimicrobial materials against biofilm formation in a high shear CDC Biofilm Reactor (CBR) and some materials in a low shear Drip Flow Reactor (DFR) which(also utilizes ultra violet light emitting diodes (UVLEDs) as an antimicrobial resource. Most materials were tested in the CBR using the ASTM E 2562-07 1method involving the Pseudomonas aeruginosa and coupon samples that vary in their antimicrobial coatings and surface layer topographies. In a controlled environmental chamber (CEC), the CBR underwent a batch phase, continuous flow phase (CFP), and a harvest before analysis. The DFR portion of this experimentation was performed in order to assess the antimicrobial capabilities of ultraviolet-A LEDs (UV-A) in potable water systems. The ASTM E 2647-08 was modified in order to incorporate UV-A LEDs and to operate as a closed, re-circulating system. The modified DFR apparatus that was utilized contains 4 separate channels each of which contain 2 UV-A LEDs (1 chamber is masked off to serve as a control) and each channel is equipped with its own reservoir and peristaltic pump head. The 10 DFR runs discussed in this report include 4 initial experimental runs that contained blank microscope slides to test the UVA LEDs alone, 2 that incorporated solid silver coupons, 2 that utilized titanium dioxide (Ti02) coupons as a photocatalyst, and 2 runs that utilized silver coated acrylic slides. Both the CBR and DFR experiments were analyzed for microbial content via heterotrophic plate counts (HPC) and acridine orange direct counts (AODC). Ofthe materials used in the CBR, only two materials performed as anti~icrobials under high shear conditions (a reduction of 5 or more logs) showing a>7 log reduction in viable microbes.

Morford, Megan A.↗

Navigation Doppler Lidar Signal Processing Architecture and Algorithms

A coherent Doppler lidar has been developed to address the need for a high-performance, compact, and cost-effective velocity and altitude sensor onboard landing vehicles. One of the core subsystems within NDL is its signal processing architecture. The primary function of this subsystem is to digitize the analog output of the homodyned signal received from the photo-diode associated with each telescope, process this signal in the frequency domain, and then turn this information into velocity and range measurements. A secondary function of this subsystem is to setup and control the internal components within NDL and to enable the instrument to interface with external systems by receiving commands, sending telemetry, and synchronizing its measurements with external clocks and pulses. This paper will give an overview of the signal processing architecture within NDL. This will include a discussion on its fundamental processing components and the core signal processing algorithms. Command, telemetry and internal component controls will also be discussed as will how the signal processing architecture has also evolved over the years of development. We will discuss provisions for robust operation including Triple-Mode Redundancy (TMR) within NDL’s Field Programmable Gate Array (FPGA) and storage elements, a fault-tolerant boot process, and Error Detection and Correction (EDAC) on the Static Random-Access Memories (SRAMs). Finally, we conclude this paper with how this architecture could continue to evolve.

Doppler Lidar↗

Spectral and small-signal electroluminescence analysis of carrier dynamics in dual-color InGaN/GaN light-emitting diodes

Here, we study carrier transport, distribution, and recombination in dual-color c-plane InGaN/GaN LEDs using spectral analysis and small-signal electroluminescence (SSEL). The emissions from green and blue quantum wells (QWs) were experimentally separated and analyzed. Spectral analysis and SSEL independently demonstrate that emission from the green QW is dominant at low current densities, consistent with its narrower bandgap, while emission from the blue QW is more significant at higher current densities, consistent with its reduced quantum confined Stark effect and larger wavefunction overlap. In addition, we demonstrate that the carrier recombination in the QWs is non-uniform, with carrier transport dramatically affecting the carrier distribution between QWs and the recombination in a specific QW. Finally, our measurements suggest that the effective active region contributing most strongly to radiative recombination corresponds to approximately two to three QWs on the p-GaN side, indicating limited carrier transport to more distant QWs in the structures studied.

36 MATERIALS SCIENCE↗

Measurement and Simulation of the Variation in Proton-Induced Energy Deposition in Large Silicon Diode Arrays

The proton induced charge deposition in a well characterized silicon P-i-N focal plane array is analyzed with Monte Carlo based simulations. These simulations include all physical processes, together with pile up, to accurately describe the experimental data. Simulation results reveal important high energy events not easily detected through experiment due to low statistics. The effects of each physical mechanism on the device response is shown for a single proton energy as well as a full proton space flux.

Howe, Christina L.↗