Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Neutronics Analysis for ITER Diagnostic Generic Upper Port Plug

This paper presents new results of neutronics analysis performed for the updated design of the ITER Diagnostic Generic Upper Port Plug (DGUPP). Such analysis is performed regularly during the development of the ITER Ports design. Neutronics analysis is an important step in support of the development of ITER components irradiated by 14 MeV neutrons generated in D-T fusion thermonuclear reactions. The neutrons are born in the ITER tokamak plasma chamber and then impinge on the surrounding blanket and port plugs, after that they diffuse through shielding material of vacuum vessel components or could stream through the diagnostic channels and assembly gaps far away from plasma up to the bio-shield and in a small amount beyond it. While ITER machine is in operation it is inaccessible, after the shut-down it is planned to provide personnel access to the Upper Port Inter-Space Structure (UP ISS) behind the Port Plug via the corridors. Neutrons activate the ITER materials and those radioactive materials emit decay gammas during the shut-down causing a Shut-Down Dose Rate (SDDR) field distributed all around the activated materials. Decay gammas could also stream through the void channels. That emphasizes the need for calculation of decay gamma transport in evaluations of SDDR, which is reflected in the use of transport - activation interface code described in Section of Computational Modelling. The assessment of radiation environment (fluxes and SDDR) at DGUPP was focused on the port back-side area of UP ISS, where personnel access is planned along the ISS maintenance corridors. Minimization of SDDR at the front part of the ISS maintenance corridors was the target value for optimization of the DGUPP shielding and analysis of related neutronics effects. Following the dose ALARA (As Low As Reasonably Achievable) principle, every possibility to reduce SDDR should be investigated, emphasizing the importance of this analysis. The challenges of such analysis are inextricably connected with the engineering complexity of the ITER machine, with integration of many diagnostics systems having channels and gaps inside the ITER ports. Those gaps result in radiation streaming and negatively affect the shielding performance of the port plugs. The computational complication is caused by the need to model precisely the ITER geometry and then to run deep penetrating radiation transport in the substantially heterogenic toroidal geometry of ITER large-size tokamak, with 30 m height and diameter of its bio-shield. The whole mass of Upper Port Plug (UPP) could be up to 25 tons and it must be very precisely positioned inside the port opening in blanket and Vacuum Vessel. Facing the engineering challenges for the assembly of DGUPP, there were proposed two Project Change Requests (PCRs) No. 439 and 709 concerning the design updates of UPP/blanket interface and its remote handling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Combustion Feature Characterization using Computer Vision Diagnostics within Rotating Detonation Combustors

Rotating detonation engines (RDEs) theoretically achieve pressure gain by continuously propagating detonation waves in a cylindrical annulus. Research aims to implement them in gas turbines for improved propulsion and power generation efficiency. Current diagnostic methods, such as point measurements and optical diagnostics, face limitations due to high data acquisition rates required to analyze rapid detonation interactions. In contrast, image classification and time series classification achieve real-time capabilities with rates of 4 and 5 Hz, respectively. Object detection offers the highest time-step resolution at 20 μsec, while real-time methods require longer resolutions of 80 msec, highlighting the advancements in diagnostic capabilities for RDEs.

May, Kristyn Johnson↗

Time resolved X-ray diffraction using the FIDDLE diagnostic at NIF: Preliminary assessment of diffraction precision

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a new diagnostic at the National Ignition Facility (NIF) designed to observe in situ solid-solid phase changes at high pressures using time resolved X-ray diffraction. FIDDLE currently incorporates five Icarus Ultrafast X-ray Imager sensors that take 2 ns snapshots and can be tuned to collect X-rays for tens of ns. The platform utilizes the laser power at NIF for both the laser drive and the generation of 10 keV X-rays for ~10 ns using a Ge backlighter foil. We aim to use FIDDLE to observe diffraction at different times during compression to probe the kinetics of phase changes. Pb undergoes two solid-solid phase transitions during ramp compression: from FCC to HCP and HCP to BCC. Results will be reported on some of the first shots using the FIDDLE diagnostic at NIF on ramp compressed Pb to a peak pressure of ~110 GPa and a single undriven CeO2 calibration shot. A discussion of the uncertainties in the observed diffraction is included.

Vennari, C. E.↗

DEVICE CONTROL TOOL FOR CEBAF BEAM DIAGNOSTICS SOFTWARE

Continuously monitoring the beam quality in the CEBAF accelerator, a variety of beam diagnostics software created at Jefferson Lab makes a significant contribution to very high availability of the machine for nuclear physics experiments. The interface between this software and beam instrumentation hardware components is provided by a device control tool, which is optimized for beam diagnostics tasks. As a part of the device/driver development framework at Jefferson Lab, this tool is very easy to support and extend to integrate new beam instrumentation components. All device control functions are based on the configuration (ASCII text) files that completely define the used hardware interface standards (CAMAC, VME, RS-232, GPIB, etc.) and communication protocols. The paper presents the main elements of the device control tool for beam diagnostics software at Jefferson Lab.

43 PARTICLE ACCELERATORS↗

Testing of optical diagnostics for ion-beam-driven WDM experiments at NDCX-1

We report on the testing of optical diagnostics developed for warm-dense-matter (WDM) experiments on the Neutralized Drift Compression Experiments (NDCX-1) at Lawrence Berkeley National Laboratory (LBNL). The diagnostics consist of a fast optical pyrometer, a streak camera spectrometer, and a VISAR.While the NDCX is in the last stage of commissioning for the target experiments, the diagnostics were tested elsewhere in an experiment where an intense laser pulse was used to generate the WDM state in metallic and carbon samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optomechanical design of a prompt gamma reaction history diagnostic

The National Ignition Facility and the Omega Laser Facility both have a need for measuring prompt gamma radiation as part of a nuclear diagnostic program. A new gamma-detection diagnostic using off-axis-parabolic mirrors has been built. Some new techniques were used in the design, construction, and tolerancing of this gamma ray diagnostic. Because of the wavelength requirement (250-700 nm), the optical element surface finishes were a key design consideration. The optical enclosure had to satisfy pressure safety concerns and shielding against electromagnetic interference induced by gammas and neutrons. Structural finite element analysis was needed to meet rigorous optical and safety requirements. The optomechanical design is presented. Alignment issues are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiple diagnostics in a high-pressure hydrogen microwave plasma torch

We present an experimental study of a hydrogen plasma produced by a microwave axial injection torch, launching the plasma in a helium-filled chamber. Three different diagnostic methods have been used to obtain the electron density and temperature as follows: The Stark intersection method of Balmer spectral lines (already tested in argon and helium plasmas); the modified Boltzmann-plot showing that the plasma is far from the local thermodynamic equilibrium but ruled by the excitation-saturation balance; and a study by the disturbed bilateral relations theory. All of these diagnostic techniques show a good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a diagnostic technique based on Cherenkov effect for measurements of fast electrons in fusion devices

A diagnostic technique based on the Cherenkov effect is proposed for detection and characterization of fast (super-thermal and runaway) electrons in fusion devices. The detectors of Cherenkov radiation have been specially designed for measurements in the ISTTOK tokamak. Properties of several materials have been studied to determine the most appropriate one to be used as a radiator of Cherenkov emission in the detector. This technique has enabled the detection of energetic electrons (70 keV and higher) and the determination of their spatial and temporal variations in the ISTTOK discharges. Measurement of hard x-ray emission has also been carried out in experiments for validation of the measuring capabilities of the Cherenkov-type detector and a high correlation was found between the data of both diagnostics. A reasonable agreement was found between experimental data and the results of numerical modeling of the runaway electron generation in ISTTOK.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics of underwater electrical wire explosion through a time- and space-resolved hard x-ray source

A time- and space-resolved hard x-ray source was developed as a diagnostic tool for imaging underwater exploding wires. A {approx}4 ns width pulse of hard x-rays with energies of up to 100 keV was obtained from the discharge in a vacuum diode consisting of point-shaped tungsten electrodes. To improve contrast and image quality, an external pulsed magnetic field produced by Helmholtz coils was used. High resolution x-ray images of an underwater exploding wire were obtained using a sensitive x-ray CCD detector, and were compared to optical fast framing images. Future developments and application of this diagnostic technique are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-view fast-ion D-alpha spectroscopy diagnostic at ASDEX Upgrade

A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional perturbative contributions to the spectra, such as D{sub 2}-molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The co-located arrangement of ECEI and MIR microwave imaging diagnostics on EAST tokamak

The co-located configuration of Passive Electron Cyclotron Emission Imaging (ECEI) and active Microwave Imaging Reflectometry (MIR) diagnostics systems has been successfully implemented on the EAST fusion reactor. These advanced 2D microwave diagnostic tools offer 10–20 mm poloidal spatial resolution through large aperture quasi optics. This arrangement not only optimizes the utilization of limited observation windows but also facilitates concurrent measurements of plasma density and electron temperature at specific toroidal positions. Furthermore, this co-located setup holds great promise for enhancing research into electron heat transport and other pivotal plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GaN-based W-band receiver chip development for fusion plasma diagnostics

Millimeter-wave diagnostics have proven effective on various magnetic fusion devices worldwide, yet the formidable challenges posed by the harsh environments of future burning plasma devices, characterized by extreme temperatures, pressures, and radiation levels, remain a significant hurdle. To address these challenges, the utilization of wide bandgap Gallium Nitride (GaN)-based millimeter-wave diagnostics is a most promising solution for fusion reactor safety monitoring and control. A noteworthy W-band GaN-based system-on-chip receiver has been the demonstrated by employing HRL T3 40 nm GaN technology. This receiver chip, compactly designed with dimensions of 3 × 5 mm 2 , incorporates essential components such as the 75–110 GHz RF Low-Noise Amplifier (LNA), mixer, Intermediate Frequency (IF) amplifier, and Local Oscillator (LO) chain. This receiver chip will be packaged as a millimeter-wave receiver module and applied on the DIII-D National Fusion Facility, for fusion plasma edge shape monitoring for operational safety and dangerous disruption prediction. The laboratory measurement results have demonstrated suitable performance. Furthermore, this advancement is pivotal for accurate analysis of plasma behavior in the extreme conditions of burning plasma devices, driving progress in fusion research and technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Talbot-Lau X-ray Deflectometer electron density diagnostic for laser and pulsed power high energy density plasma experiments

Talbot-Lau X-ray Deflectometry has been developed as an electron density diagnostic for High Energy Density plasmas. The technique can deliver x-ray refraction, attenuation, elemental composition, and scatter information from a single Moiré image. An 8 keV Talbot-Lau interferometer was deployed using laser and x-pinch backlighters. Grating survival and electron density mapping was demonstrated for 25-29 J, 8-30 ps laser pulses using copper foil targets. Moire pattern formation and grating survival was also observed using a copper x-pinch driven at 400 kA, ~1 kA/ns. Lastly, these results demonstrate the potential of TXD as an electron density diagnostic for HED plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Report for "Modeling Electron Cloud Diagnostics for High-Intensity Proton Accelerators"

Electron clouds in accelerators such as the ILC degrade beam quality and limit operating efficiency. The need to mitigate electron clouds has a direct impact on the design and operation of these accelerators, translating into increased cost and reduced performance. Diagnostic techniques for measuring electron clouds in accelerating cavities are needed to provide an assessment of electron cloud evolution and mitigation. Accurate numerical modeling of these diagnostics is needed to validate the experimental techniques. In this Phase I, we developed detailed numerical models of microwave propagation through electron clouds in accelerating cavities with geometries relevant to existing and future high-intensity proton accelerators such as Project X and the ILC. Our numerical techniques and simulation results from the Phase I showed that there was a high probability of success in measuring both the evolution of electron clouds and the effects of non-uniform electron density distributions in Phase II.

43 PARTICLE ACCELERATORS↗

Challenges in Developing Electrodes, Electrolytes, and Diagnostics Tools to Understand and Advance Sodium-Ion Batteries

Here, considering the natural abundance and low cost of sodium resources, sodium-ion batteries (SIBs) have received much attention for large-scale electrochemical energy storage. However, smart structure design strategies and good mechanistic understanding are required to enable advanced SIBs with high energy density. In recent years, the exploration of advanced cathode, anode and electrolyte materials as well as advanced diagnostics have been extensively carried out. This review mainly focused on the challenging problems for the attractive battery materials (i.e. cathode, anode and electrolytes) and summarized the latest strategies to improve their electrochemical performance as well as presented recent progress of operando diagnostics to disclose the physic behind the electrochemical performance, and to provide guidance and approaches to design and synthesize advanced battery materials. Outlook and perspectives on the future research to build better SIBs are also provided.

25 ENERGY STORAGE↗

Diagnostic Yield of Computed Tomography-Guided Coaxial Core Biopsy of Undetermined Masses in the Free Retroperitoneal Space: Single-Center Experience

The purpose of this study was to evaluate the diagnostic yield of core biopsy in coaxial technique under guidance of computed tomography (CT) for retroperitoneal masses. We performed a retrospective analysis of CT-guided coaxial core biopsies of undetermined masses in the non-organ-bound retroperitoneal space in 49 patients. In 37 cases a 15-G guidance needle with a 16-G semiautomated core biopsy system, and in 12 cases a 16-G guidance needle with an 18-G biopsy system, was used. All biopsies were technically successful. A small hematoma was seen in one case, but no relevant complication occurred. With the coaxial technique, up to 4 specimens were obtained from each lesion (mean, 2.8). Diagnostic accuracy in differentiation between malignant and benign diseases was 95.9%. A specific histological diagnosis could be established in 39 of 42 malignant lesions (92.9%). Correct subtyping of malignant lymphoma according to the WHO classification was possible in 87.0%. Benign lesions were correctly identified in seven cases, although a specific diagnosis could only be made in conjunction with clinical and radiological information. In conclusion, CT-guided coaxial core biopsy provides safe and accurate diagnosis of retroperitoneal masses. A specific histological diagnosis, which is essential for choosing the appropriate therapy, could be established in most cases of malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗