Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tangential extreme ultraviolet and soft x-ray diagnostic system for time-resolved temperature measurement on the High Beta Tokamak-Extended Pulse

The High Beta Tokamak-Extended Pulse has recently incorporated a tangential multi-energy extreme ultraviolet and soft x-ray diagnostic system. This system enables measurements of the electron temperature and the examination of mode dynamics within the tokamak. While other systems have been built for poloidal views over similar temperature ranges, this is the first multi-energy tangential-view system designed to work in a temperature range below 200 eV in a tokamak. To facilitate these measurements, a filter wheel comprising five distinct groups of dual-filters has been developed and implemented. By employing a combination of 0.1 μm aluminum and 0.2 μm titanium filters, the system allows estimation of electron temperature profiles through reconstruction of the emission profile using the standard “double-foil” technique. The influence of impurities and filter oxide layers on measurement outcomes is examined. Results reveal that, while the absolute electron temperature values may exhibit some deviations, key characteristics like the electron temperature profile shape and inversion radius during sawtooth events remain consistent. This consistency confirms the system’s suitability for core plasma studies. This system has proven effective in detecting and analyzing internal magnetohydrodynamic phenomena, such as sawteeth.

Instruments & Instrumentation↗

Aligning the Thomson scattering and charge exchange recombination diagnostics using neutral beam emission at DIII-D

This work addresses discrepancies in the alignment of the H-mode pedestal profiles of the electron and ion properties in the DIII-D tokamak as measured by Thomson Scattering (TS) and Charge Exchange Recombination Spectroscopy (CER) diagnostics. While the alignment of these profiles is key for accurate studies of tokamak physics and plasma confinement, misalignments can occur due to inaccuracies, such as in magnetic equilibrium reconstructions required to map measurements in different poloidal and toroidal locations. Both FIDASIM, an established simulation package, and a simplified collisional radiative model are used to simulate neutral beam state densities and neutral beam emission. Simulated neutral beam emissions are calculated based on shifted TS profiles and compared to beam emission measurements from the Main Ion CER system to determine the best shift for aligning TS with CER. This analysis is performed on various DIII-D discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

Design and development of the magnetic diagnostic systems for the first operational phase of the SMART tokamak

A set of magnetic diagnostics has been designed, manufactured, and calibrated for the first operational phase of the small aspect ratio tokamak. The sensor suite comprises of Rogowski coils; 2D magnetic probes; and poloidal, saddle, and diamagnetic flux loops. Here, a set of continuous Rogowski coils has been manufactured for the measurement of plasma current and induced eddy currents in conductive elements. A set of flux loops and magnetic probes will be used as input for the reconstruction of the magnetohydrodynamic equilibrium. The quantity and position of these sensors have been verified to be sufficient with synthetic equilibrium reconstructions using the equilibrium fitting code and baseline scenarios computed with the Fiesta code. These sensors will also be used as input for the real-time control system, and magnetic probes will be used for the detection of plasma instabilities. The calibration procedure for the magnetic probes is described, and the results are shown. The signal conditioning and data acquisition systems are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

Analysis of an induced Langmuir wave by ponderomotive forces and its applicability for plasma diagnostics

We present a numerical study on the electron and ion density perturbation in low-temperature plasmas driven by the frequency detuning of two intense laser beams. Our study is performed in the hydrodynamic regime, which becomes applicable when the plasma grating period induced by the beating of the laser beams is greater than the Debye length and collective processes such as plasma oscillations can be excited. Our findings show a resonance in electron density perturbation as the frequency detuning approaches a value consistent with the Bohm–Gross dispersion relation in low- and high-pressure plasmas. We discuss the potential of this resonance as a diagnostic tool for precisely measuring electron temperature and density in low-temperature plasmas through coherent scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reaction-in-flight neutrons as a diagnostic for hydrodynamical mixing in double shell inertial confinement fusion capsules

We examine reaction-in-flight (RIF) neutrons as diagnostics for hydrodynamical mixing of high-Z shell material into the hotspot of double shell capsules that are designed for the National Ignition Facility. In particular, we consider the effects of different levels of mixing of tungsten shell material into the DT gas on RIF spectra. Using a set of 1D simulations from the radiation hydrodynamic code xRAGE to determine the temperature and density profiles of the mixed W-DT gas, we find that increasing the mass of mix systematically reduces the ratio of RIF neutrons to primary 14 MeV neutrons. The shape of the RIF spectrum also changes with mix, with the predicted spectrum softening in energy with increasing mix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward model-free temperature diagnostics of warm dense matter from multiple scattering angles

Warm dense matter plays an important role in astrophysical objects and technological applications, but the rigorous diagnostics of corresponding experiments is notoriously difficult. In this work, we present a model-free analysis of x-ray Thomson scattering (XRTS) measurements on isochorically heated graphite obtained at the Linac Coherent Light Source at multiple scattering angles. We demonstrate that the recent imaginary-time thermometry technique works for scattering data that have been measured in both forward and backward scattering geometry. This opens up the way toward a rigorous quantification of nonequilibrium effects in future experiments, where XRTS measurements are being obtained from multiple scattering angles from the same sample.

Equations of state↗

Preface to the Proceedings of the 25th Topical Conference on High-Temperature Plasma Diagnostics

The 25th Topical Conference on High-Temperature Plasma Diagnostics (HTPD 2024) was held in Asheville, NC, USA, at the Renaissance Asheville Downtown Hotel from 21 to 25 April 2024. This biennial conference brings together scientists and engineers from a variety of fields, including magnetic confinement fusion, inertial confinement fusion, space plasmas, astrophysics, and industrial applications, to discuss mutual problems in the development of instrumentation and experimental techniques for the characterization of high-temperature plasmas. As the 25th meeting, HTPD 2024 represents ∼50 years of ongoing international collaboration on these topics.

Biewer, Theodore [ORNL] (ORCID:0000000174563509)↗

Optimization and active stabilization of a far-infrared laser for NSTX-U high poloidal wavenumber scattering diagnostics

The far-infrared (FIR) laser output beam power and profile are important parameters in the laser-aided diagnostics, directly influencing the spatial resolution and signal-to-noise ratio of measurements. Here, this work focuses on developing a systematic control method to enhance FIR laser beam quality through optimized mirror alignment and real-time feedback-based precision cavity length tuning. A 150 W CO 2 laser, aligned with the waveguide axis using a HeNe reference laser, serves as the pump source. The sensitivity of FIR beam intensity to pump gas pressure and thermal expansion is investigated, revealing that even a 1 µm cavity expansion can significantly degrade output power stability to about two-thirds of its original value. To address this, a feedback control module has been designed and implemented for active cavity length adjustment, stabilizing the output power at ∼30 mW. In addition, maintaining a high formic acid gas pressure ($>$190 mTorr) within the cavity ensures reliable operation. The optimized FIR laser will be deployed on the National Spherical Torus eXperiment-U high poloidal wavenumber scattering system for studying electron-scale turbulence in tokamak plasmas.

Xu, Xinhang [Univ. of California, Davis, CA (Unite↗

X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids

We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.

Crystal lattices↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Results from the Alfvén Eigenmode Active Diagnostic during the 2019-2020 JET deuterium campaign

This paper presents results of extensive analysis of mode excitation observed during the operation of the Alfvén Eigenmode Active Diagnostic (AEAD) in the JET tokamak during the 2019-2020 deuterium campaign. Here, six of eight toroidally spaced antennas, each with independent power and phasing, were successful in actively exciting stable MHD modes in 479 plasmas. In total, magnetic resonances were detected with up to fourteen fast magnetic probes. In this work, we present the calculations of resonant frequencies $f_0$, damping rates γ < 0, and toroidal mode numbers $\textit{n}$, spanning the parameter ranges $f_0$ ≈ 30–250 kHz, –γ ≈ 0–13 kHz, and $\vert n \vert \leq {30}$. In general, good agreement is seen between the resonant and the calculated toroidal Alfvén Eigenmode frequencies, and between the toroidal mode numbers applied by the AEAD and estimated of the excited resonances. We note several trends in the database: the probability of resonance detection decreases with plasma current and external heating power; the normalized damping rate increases with edge safety factor but decreases with external heating. These results provide key information to prepare future experimental campaigns and to better understand the physics of excitation and damping of Alfvén Eigenmodes in the presence of alpha particles during the upcoming DT campaign, thereby extrapolating with confidence to future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Edge fluctuation measurements in EDA H-mode and QCE plasmas in ASDEX Upgrade using the correlation electron cyclotron emission diagnostic

The requirement of a plasma solution without large edge-localized modes (ELMs) for future fusion devices motivates the study of plasmas without Type I ELMs. The enhanced D–α (EDA) and quasi-continuous exhaust (QCE) scenarios are two such Type I ELM free plasmas, but their underlying physics principles are not fully understood. A database of EDA and QCE plasmas from ASDEX Upgrade was compiled and analyzed using the correlation electron cyclotron emission diagnostic in order to study differences between properties of the quasi-coherent mode (QCM) between these two regimes. Investigations into measured spectral properties of the QCM, radiated temperature fluctuations δT rad /T rad , and radial correlation lengths L c showed no differences between the two regimes. Spectral properties using the cross-power spectral density, G xy were similar between regimes, with the values measured to be a central frequency, $f$ $QCM$ ≈ 20 - 50 kHz; spectral width, Δ $f$ ≈ 5 - 40 kHz; δT rad /T rad ≈ 4-6%; and L c ≈ 1-2 cm. Investigations into a quantity representing the relative bandwidth Δ$f$/$f$ $QCM$ revealed differences between EDA and QCE plasmas when plotted radially, suggesting some type of interaction between the QCM in QCE plasmas with the surrounding broadband turbulence that is not present in EDA phases. Additionally, investigations into various drive terms for hypothesized instability drivers for the QCM are performed showing no difference in the parameter spaces of collisionality and the ion temperature, electron temperature, or electron pressure scale lengths between each regime indicating that there is no observable difference between the drive behind the QCM in each regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma dynamics, instabilities and OH generation in a pulsed atmospheric pressure plasma with liquid cathode: a diagnostic study

Abstract While plasma–liquid interactions have been an important focus in the plasma research community, the impact of the strong coupling between plasma and liquid on plasma properties and processes remains not fully understood. In this work, we report on the impact of the applied voltage, pulse width and liquid conductivity on the plasma morphology and the OH generation for a positive pulsed DC atmospheric pressure plasma jet with He–0.1% H 2 O mixture interacting with a liquid cathode. We adopted diagnostic techniques of fast imaging, 2D laser induced fluorescence of OH and Thomson scattering spectroscopy. We show that plasma instabilities and enhanced evaporation occur and have a significant impact on the OH generation. At elevated plasma energies, it is found that the plasma contracts due to a thermal instability through Ohmic heating and the contraction coincides with a depletion in the OH density in the core due to electron impact dissociation. For lower plasma energies, the instability is suppressed/delayed by the equivalent series resistor of the liquid electrode. An estimation of the energy flux from the plasma to the liquid shows that the energy flux of the ions released into the liquid by positive ion hydration is dominant, and significantly larger than the energy needed to evaporate sufficient amount of water to account for the measured H 2 O concentration increase near the plasma–liquid interface.

Physics↗

Experimental studies of plasma-antenna coupling with the JET Alfvén Eigenmode Active Diagnostic

Here, this paper presents a dedicated study of plasma-antenna (PA) coupling with the Alfvén Eigenmode Active Diagnostic (AEAD) in JET. Stable AEs and their resonant frequencies f, damping rates γ < 0, and toroidal mode numbers n are measured for various PA separations and limiter versus X-point magnetic configurations. Two stable AEs are observed to be resonantly excited at distinct low and high frequencies in limiter plasmas. The values of f and n do not vary with PA separation. However, |γ| increases with PA separation for the low-f, but not high-f, mode, yet this may be due to slightly different edge conditions. The high-f AE is detected throughout the transition from limiter to X-point configuration, though its damping rate increases; the low-f mode, on the other hand, becomes unidentifiable. The linear, resistive MHD code CASTOR is used to simulate the frequency scan of an AEAD-like external antenna. For the limiter pulses, the high-f mode is determined to be an n = 0 GAE, while the low-f mode is likely an n = 2 TAE. During the transition from limiter to X-point configuration, CASTOR indicates that n = 1 and 2 EAEs are excited in the edge gap. These results extend previous experimental studies in JET and Alcator C-Mod; validate the computational work performed by Dvornova et al; and provide guidance for the optimization of PA coupling in upcoming JET energetic particle experiments, for which the AEAD will aim to identify the contribution of alpha particles to AE drive during the DT campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alfvén eigenmode classification based on ECE diagnostics at DIII-D using deep recurrent neural networks

Modern tokamaks have achieved significant fusion production, but further progress towards steady-state operation has been stymied by a host of kinetic and MHD instabilities. Control and identification of these instabilities is often complicated, warranting the application of data-driven methods to complement and improve physical understanding. In particular, Alfvén eigenmodes are a class of ubiquitous mixed kinetic and MHD instabilities that are important to identify and control because they can lead to loss of confinement and potential damage to the walls of a plasma device. In the present work, we use reservoir computing networks to classify Alfvén eigenmodes in a large labeled database of DIII-D discharges, covering a broad range of operational parameter space. However, despite the large parameter space, we show excellent classification and prediction performance, with an average hit rate of 91% and false alarm ratio of 7%, indicating promise for future implementation with additional diagnostic data and consolidation into a real-time control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗