Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Research and Development Studies for Reactor Neutrino Experiments in Turkey (RNET)

The program of the Reactor Neutrino Experiments of Turkey includes a small portable Water-based liquid scintillator detector to detect neutrinos from the Akkuyu nuclear power plant, planned to begin operating in 2023. The small near-field detector will weigh about 2-3 tons and will be placed less than 100 meters from the reactor cores. The Reactor Neutrino Experiments of Turkey program also includes a medium-size 30-ton Water-based liquid scintillator detector, which will be placed 1-2 km away from the reactor cores and will be used as a far detector. Both detectors and their responses to neutrino interactions were simulated using a GEANT4-based RAT-PAC simulation package. Here, we will share the technical and physical details of both detectors, and discuss the ongoing R&D effort for neutrino studies in Turkey.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near-infrared linear array spectrometer for space applications

A 128-element InSb linear detector array read out with a field effect transistor (FET) multiplexing scheme has been developed at the Jet Propulsion Laboratory. State-of-the-art NEP, uniform response, on-detector charge integration, and very low focal plane heat load compared to that of discrete detector arrays allows this type of array to open new possibilities for spaceborne near-infrared imaging spectrometers. Large number of cooled detector elements are feasible with the new technology, making it practical to design sensitive spectrometers even for spinning spacecraft where simultaneous wavelength coverage is necessary to avoid confusion of spatial with spectral variations.

Apt, J.↗

Wavelength Shifting in InP based Ultra-thin Quantum Well Infrared Photodetectors

We have demonstrated red-shifting of the wavelength response of a bound-to-continuum p-type ultra-thin InGaAs/Inp quantum well infrared photodetector after growth via rapid thermal annealing. Compared to the as-grown detector, the peak spectral response of the annealed detector was shifted to longer wavelength without any major degradation in responsivity characteristics.

Photodetector Thermal Annealing↗

IR detectors based on n-i-p-i superlattices

The principles of operation of n-i-p-i photodetectors are discussed. Special consideration is given to issues that are relevant to the performance of IR detectors such as noise, dark current, and surface effects. In addition, a novel IR detector that promises to provide information about the spectral distribution of the infrared radiation emitted from an object and, consequently, about its temperature, independent of the distance between detector and object is discussed. This detector makes use of the possibility to modulate the internal electric fields of an n-i-p-i superlattice with an applied voltage. By this technique the spectral responsivity of the detector may be controlled electrically and some information about the shape of the emission spectrum may be obtained.

Ruden, P. Paul↗

LWIR detector research in InAsSb/InAs

The InAsSb/InSb strained-layer system forms a type-II superlattice in the Sb-rich region of the phase diagram. The band gap of InAsSb/InSb strained-layer superlattices grown on lattice-matched buffers can be varied continuously to produce semiconducting systems with band gaps ranging from that of InSb (0.23 eV with an absorption edge at 5.5 microns at 77 K) to 0. The semiconductor to semimetal transition occurs at As concentrations of approximately 33 percent, with the precise value dependent upon the strain and quantum well dimensions. At higher As content, the system is a semimetal. The authors fabricated photovoltaic detectors with high D asterisk at 77 K at wavelengths beyond 10 microns, and both photovoltaic and photoconductive detectors have been demonstrated with response to 15 microns. The photoconductive detectors exhibit gain of up to 100. Details of the materials growth, studies of the band structure and properties, device processing and the detector performance observed to date in these systems are discussed.

Peercy, Paul S.↗

A Detailed FLUKA-2005 Monte Carlo Simulation for the ATIC Detector

We have performed a detailed Monte Carlo (MC) calculation for the Advanced thin Ionization Calorimeter (ATIC) detector using the MC code FLUKA-2005 which is capable of simulating particles up to 10 PeV. The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon Bight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy; using a fully active Bismuth Germanate @GO) calorimeter. It is equipped with a large mosaic of silicon detector pixels capable of charge identification and as a particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the middle and below a 0.75 nuclear interaction length graphite target. Our calculations are part of an analysis package of both A- and energy-dependences of different nuclei interacting with the ATIC detector. The MC simulates the responses of different components of the detector such as the Simatrix, the scintillator hodoscopes and the BGO calorimeter to various nuclei. We also show comparisons of the FLUKA-2005 MC calculations with a GEANT calculation and data for protons, He and CNO.

Gunasingha, R. M.↗

Comparison of Fluka-2006 Monte Carlo Simulation and Flight Data for the ATIC Detector

We have performed a detailed Monte Carlo (MC) simulation for the Advanced Thin Ionization Calorimeter (ATIC) detector using the MC code FLUKA-2006 which is capable of simulating particles up to 10 PeV. The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon flight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy; using a fully active Bismuth Germanate(BGO) calorimeter. It is equipped with a large mosaic of.silicon detector pixels capable of charge identification, and, for particle tracking, three projective layers of x-y scintillator hodoscopes, located above, in the middle and below a 0.75 nuclear interaction length graphite target. Our simulations are part of an analysis package of both nuclear (A) and energy dependences for different nuclei interacting in the ATIC detector. The MC simulates the response of different components of the detector such as the Si-matrix, the scintillator hodoscopes and the BGO calorimeter to various nuclei. We present comparisons of the FLUKA-2006 MC calculations with GEANT calculations and with the ATIC CERN data and ATIC flight data.

Gunasingha, R.M.↗

Production and installation of wavelength-shifting reflective light enhancers for the Short-Baseline Near Detector

We report on the design, production, and installation of a wavelength-shifting reflective system on the cathode of the Short-Baseline Near Detector (SBND), a liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam. To increase and homogenize scintillation-light collection, 64 double-sided plates were fabricated from FR4, laminated with specular reflector film and coated with 300 $μ$g/cm$^2$ of tetraphenyl butadiene (TPB) wavelength shifter using controlled physical vapor deposition. The coating uniformity was validated through dedicated measurements of deposited mass and profilometry studies. Because exposure to ambient blue/UV light could degrade the TPB, protective filtering and controlled storage conditions were implemented during handling and installation. The coated plates were assembled between conductive meshes for high-voltage compatibility and installed in situ during detector integration. This system constitutes the largest TPB-coated area deployed in a neutrino detector. It operates in conjunction with SBND's photon detection system, which consists of photomultiplier tubes and X-ARAPUCAs. Early light-collection measurements show high uniformity and light response across the detector, supporting improved triggering, calorimetry, and position reconstruction in SBND.

Acciarri, R. [Fermilab]↗

Gallium arsenide quantum well-based far infrared array radiometric imager

We have built an array-based camera (FIRARI) for thermal imaging (lambda = 8 to 12 microns). FIRARI uses a square format 128 by 128 element array of aluminum gallium arsenide quantum well detectors that are indium bump bonded to a high capacity silicon multiplexer. The quantum well detectors offer good responsivity along with high response and noise uniformity, resulting in excellent thermal images without compensation for variation in pixel response. A noise equivalent temperature difference of 0.02 K at a scene temperature of 290 K was achieved with the array operating at 60 K. FIRARI demonstrated that AlGaAS quantum well detector technology can provide large format arrays with performance superior to mercury cadmium telluride at far less cost.

Forrest, Kathrine A.↗

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/\mu}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/\mu}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$\pi$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical proximity detector

Sensitive, relatively inexpensive instrument uses phase-detection techniques to sense presence of objects. Phase-sensitive detectors, LED, photodiode with response matched to LED output, and filtering lens allow detector to operate over narrow radiation band, giving selectivity over stray light.

Hermann, W. A.↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Compressive sensing optical design and simulation tool

A system or method for designing optical systems includes generating a mathematical model of an imaging system; tracing a plurality of light rays from a source through the model of the imaging system in a forward direction and a backward direction incident upon an arbitrarily defined detector location; calculating the total light rays incident upon the arbitrarily defined detector location in response to the plurality of light rays; tracing a series of calibration images first through the computational or compressive imager mathematical model; measuring an output set of parameters based on a plurality of detected rays calibration images at the defined detector location; storing the output set of parameters in software, and determining an estimated system transfer function.

42 ENGINEERING↗

Extension of long wavelength response by modulation doping in extrinsic germanium infrared detectors

A new concept for infrared detectors based on multilayer epitaxy and modulation doping has been investigated. This permits a high doping concentration and lower excitation energy in the photodetecting layer as is necessary for longer wavelength response, without incurring the detrimental effects of increased dark current and noise as would be the case with conventional detector designs. Germanium photodetectors using conventional materials and designs have a long wavelength cutoff in the infrared at 138 microns, which can only be extended through the inconvenient application of mechanical stress or magnetic fields. As a result of this approach which was arrived at from theoretical considerations and subsequently demonstrated experimentally, the long wavelength cutoff for germanium extrinsic detectors was extended beyond 200 microns, as determined by direct infrared optical measurements.

Hadek, V.↗

The non-Z-squared response of the heavy nuclei cosmic ray detector on HEAO-3

A combination of ion chambers and Cerenkov radiators similar to the Heavy Nuclei Experiment flown on HEAO-3 was calibrated at the Bevalac heavy-ion accelerator using beams of Mn-25 nuclei at kinetic energies up to about 1700 MeV/nucleon and Au-79 nuclei up to about 1000 MeV/nucleon. The data show only a small deviation (about 2-3 charge units at Au) from the Z-squared scaling used previously (Binns et al., 1981, 1982, 1983) to analyze the HNE data. Although at lower energy, the calibration indicates that the published relative abundances of the Sn-50/Ba-56 group and the published upper-limit actinide abundances are not likely to be significantly affected by non-Z-squared effects.

Garrard, T. L.↗

Proportional counters as low energy photon detectors

We investigated the response of an argon-methane proportional counter to monochromatic X-rays in the range 99 to 277 eV. The apparent nonlinearities in mean pulse height as a function of photon energy and the detailed shape of the pulse height distribution for each energy can be predicted quite precisely using the extensive atomic data available for argon. Based on this understanding, we propose a semi-empirical system for using a limited amount of calibration data to predict the full response of counters employing less well-characterized gases. Such accurate models of proportional counters are required to maximize the spectral information that can be derived from observed pulse height distributions.

Jahoda, Keith↗

Intra-Pixel Response Characterization of a HgCdTe Near Infrared Detector with a Pronounced Crosshatch Pattern

The “crosshatch” pattern is a recurring “feature” of HgCdTe arrays, specifically the Teledyne HAWAII family of near infrared detectors. It is a fixed pattern of high frequency QE variations along 3 directions generally thought to be related to the crystal structure of HgCdTe. The pattern is evident in detectors used in WFC3/IR, WISE, JWST, and in candidate detectors for Euclid and WFIRST. Using undersampled point sources projected onto a HAWAII-2RG detector, we show that the pattern induces photometric variations that are not removed by a flat-field calibration, thus demonstrating that the QE variations occur on scales smaller than the 18 micron pixels. Our testbed is the Precision Projector Laboratory’s astronomical scene generator, which can rapidly characterize the full detector by scanning thousands of undersampled spots. If not properly calibrated, detectors showing strong crosshatch may induce correlated errors in photometry, astrometry, spectroscopy, and shape measurements.

Smith, Roger↗