Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Development of high-resolution muon tracking systems based on micro-pattern detectors

A muon tracking system consisting of four 9 cm x 10 cm sized bulk Micromegas detectors with 128 {mu}m amplification-gap and two 10 cm x 10 cm triple GEM detectors is foreseen for high-precision tracking of 140 GeV muons at the H8 beamline at CERN with a rate of up to 10 kHz and an overall resolution below 40 {mu}m. Larger detectors with an active area of 0.5 m{sup 2} and more are under development for detector studies in high neutron or gamma ray background environments at the Gamma Irradiation Facility at CERN and the Munich tandem accelerator. Signal studies of both detector types have been performed by recording cosmic muon and 5.9 keV X-ray signals with a single charge-sensitive preamplifier using several gas-mixtures of Ar:CO{sub 2}. The signals were digitized using 1 GHz VME based flashADCs with 2520 sampling points. The analysis of the complete signal-cycles allows for the determination of rise times, pulse heights, timing fluctuations and discrimination of background, resulting in a FWHM energy resolution of about 20% and detection efficiencies of 99% and more. Models for signal formation in both detector types will be presented. The single detector spatial resolution of 80 {mu}m was measured using a fast Gassiplex based strip readout with readout strips of 150 {mu}m width and a pitch of 250 {mu}m. The Gassiplex readout, formerly used at the HERMES experiment, had to be substantially adapted. No more crosstalk or non-linearities were observed after reconfiguration of the multiplexing amplifier on the front-end boards. The observed spatial resolution is limited by multiple scattering of the cosmic muons used in the laboratory. We also report on the sensitivity to gamma- and neutron background and on the behaviour of spatial resolution as a function of background rates. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Gamma-ray Burst Detector Based on the Silicon Drift Detector Array and Scintillators

We propose a gamma-ray burst (GRB) detector combining the silicon drift detector (SDD) array and scintillators with broadband X-ray and gamma-ray coverage (0.5-1000 keV or more), high energy resolution (2-10%) and high time resolution ({approx}{mu}s) in space. To realize such compact high-performance detector without photomultiplier tubes, we constructed proto-type model using KETEK SDD with a detection area of 1 cm{sup 2} and BGO crystal. The detector shows a very good performance. Obtained FWHM energy resolution was 191 eV at 5.9 keV in the SDD, while 6.5 % at 662 keV in the BGO at -30 deg. C. Evaluation of the 7 channel SDD array and development of analog ASIC for its readout are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2010 Neutron Review: ORNL Neutron Sciences Progress Report

During 2010, the Neutron Sciences Directorate focused on producing world-class science, while supporting the needs of the scientific community. As the instrument, sample environment, and data analysis tools at High Flux Isotope Reactor (HFIR ) and Spallation Neutron Source (SNS) have grown over the last year, so has promising neutron scattering research. This was an exciting year in science, technology, and operations. Some topics discussed are: (1) HFIR and SNS Experiments Take Gordon Battelle Awards for Scientific Discovery - Battelle Memorial Institute presented the inaugural Gordon Battelle Prizes for scientific discovery and technology impact in 2010. Battelle awards the prizes to recognize the most significant advancements at national laboratories that it manages or co-manages. (2) Discovery of Element 117 - As part of an international team of scientists from Russia and the United States, HFIR staff played a pivotal role in the discovery by generating the berkelium used to produce the new element. A total of six atoms of ''ununseptium'' were detected in a two-year campaign employing HFIR and the Radiochemical Engineering Development Center at Oak Ridge National Laboratory (ORNL) and the heavy-ion accelerator capabilities at the Joint Institute for Nuclear Research in Dubna, Russia. The discovery of the new element expands the understanding of the properties of nuclei at extreme numbers of protons and neutrons. The production of a new element and observation of 11 new heaviest isotopes demonstrate the increased stability of super-heavy elements with increasing neutron numbers and provide the strongest evidence to date for the existence of an island of enhanced stability for super-heavy elements. (3) Studies of Iron-Based High-Temperature Superconductors - ORNL applied its distinctive capabilities in neutron scattering, chemistry, physics, and computation to detailed studies of the magnetic excitations of iron-based superconductors (iron pnictides and chalcogenides), a class of materials discovered in 2008. This research is yielding new insights into the relationship between magnetism and superconductivity and has established several key features of this family of high-temperature superconducting (HTS ) materials: the maximum magnetic field at which they can function, the nature of the electrons involved in the superconductivity, the dependence of the properties upon chemical substitution, and the character of the magnetic fluctuations in the material. The results suggest that despite important differences between these materials and the HTS copper oxides, a universal mechanism may be responsible for the unconventional superconductivity. (4) Coal Sequestration Research: A New Home for Greenhouse Gases - One possibility for slowing down the increasing levels of carbon dioxide (CO{sub 2}) in the atmosphere is to capture the gas in natural underground features such as coal seams. Critical to the feasibility of this technology is determining how much CO{sub 2} can be stored, no method for which has been found - until now. (5) Accelerator Reliability Passes 92% - In December 2010, SNS set a new record for itself when the accelerator ran at 1 MW with 100% reliability. Target Performance Exceeds All Expectations - The mercury target used at SNS is the first of its kind. During the design and planning for SNS, many people were skeptical that the target would work. In 2010, it was confirmed that the target was working not only well but much better than anyone would have imagined. (6) Changing the World of Data Acquisition - Researchers at SNS are starting to benefit from event-based data analysis. Event data mode captures and stores an individual data set for every single neutron that strikes a detector - precisely when and where the neutron is detected. This technique provides numerous advantages over traditional methods. Event data mode allows researchers to process their data at the highest resolution possible with no loss of data. This method of data collection provides a much more efficient way for users to gather data and get the most from their beam time. (7) New Laboratories for Users - The HFIR and SNS user communities continue to grow dramatically. In 2010, HFIR hosted 862 users and SNS 796, outpacing projections for both facilities. To meet the needs of those users, a new complex of 13 laboratories is now open for users at SNS. (8) Innovative Detectors Provide Relief from Helium-3 Shortage - Helium-3 ({sup 3}He) has been the gas of choice for gaseous detectors since the early days of neutron science. About two years ago, detector scientists worldwide faced the reality that stockpiles of {sup 3}He are dwindling rapidly, while demand for it has risen by a factor of five. The Neutron Sciences Detectors Group has developed two new types of detectors that don't rely on {sup 3}He: the Anger camera and the wavelength shifting fiber neutron detector, both of which use lithium ({sup 6}Li).

High Flux isotope reactor↗

A Low-Power, Radiation-Resistant, Silicon-Drift-Detector Array for Extraterrestrial Element Mapping

We are developing a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) for measuring the abundances of light surface elements (C to Fe) fluoresced by ambient radiation on remote airless bodies. The value of fluorescence spectrometry for surface element mapping is demonstrated by its inclusion on three recent lunar missions and by exciting new data that have recently been announced from the Messenger Mission to Mercury. The SDD-XRS instrument that we have been developing offers excellent energy resolution and an order of magnitude lower power requirement than conventional CCDs, making much higher sensitivities possible with modest spacecraft resources. In addition, it is significantly more radiation resistant than x-ray CCDs and therefore will not be subject to the degradation that befell recent lunar instruments. In fact, the intrinsic radiation resistance of the SDD makes it applicable even to the harsh environment of the Jovian system where it can be used to map the light surface elements of Europa. In this paper, we first discuss our element-mapping science-measurement goals. We then derive the necessary instrument requirements to meet these goals and discuss our current instrument development status with respect to these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an array of liquid-scintillator-based bar detectors: SABRE

We present that an array of neutron detectors based on liquid scintillator technology has been developed for nuclear reaction studies, in particular measurements with radioactive ion beams (RIBs). Reaction measurements with RIBs often involve low reaction yields and high gamma-induced backgrounds, which requires high solid angle coverage, high efficiency, and background reduction capability. The kinematics of the reaction neutrons require energy and position determination with good resolution, but preferably without a large number of readouts to minimize cost. To address these requirements, the Scintillation Array of Bars for Reaction Experiments (SABRE) consists of five 12” long, 2” diameter bar detectors filled with organic liquid scintillator and capped at both ends with individually read-out superbialkali photomultiplier tubes (PMTs). Finally, in-house purification of the scintillator mixtures resulted in improved light collection. Discussion of the liquid scintillator development and the design and commissioning of SABRE will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Effects of n-type, Low Resistivity, Spiral Silicon Drift Detector Hybrid Systems

We have developed a new thin-window, n-type, low-resistivity, spiral silicon drift detector (SDD) array - to be used as an extraterrestrial X-ray spectrometer (in varying environments) for NASA. To achieve low-energy response, a thin SDD entrance window was produced using a previously developed method. These thin-window devices were also produced on lower resistivity, thinner, n-type, silicon material, effectively ensuring their radiation hardness in anticipation of operation in potentially harsh radiation environments (such as found around the Jupiter system). Using the Indiana University Cyclotron Facility beam line RERS1, we irradiated a set of suitable diodes up to 5 Mrad and the latest iteration of our ASICs up to 12 Mrad. Then we irradiated two hybrid detectors consisting of newly, such-produced in-house (BNL) SDD chips bonded with ASICs with doses of 0.25 Mrad and 1 Mrad. Also we irradiated another hybrid detector consisting of previously produced (by KETEK) on n-type, high-resistivity SDD chip bonded with BNL's ASICs with a dose of 1 Mrad. The measurement results of radiated diodes (up to 5 Mrad), ASICs (up to 12 Mrad) and hybrid detectors (up to 1 Mrad) are presented here.

43 PARTICLE ACCELERATORS↗

The development, testing and characterisation of a straw tracking detector and readout system for the Fermilab muon g-2 experiment

The anomalous magnetic moments of leptons can be both measured and theoretically predicted with high precision, and as such provide stringent tests of the Standard Model (SM) of particle physics. The anomalous magnetic moment of the muon, $a_\mu$, in particular offers sensitivity to new physics within the reach of current experiments. The current world’s best measurement of aμ made at the Brookhaven National Laboratory (BNL) deviates from the SM prediction by over 3σ, providing a tantalising but inconclusive hint that contributions from new physics may be present. A new $a_\mu$ experiment is currently under construction at the Fermi National Accelerator Laboratory (Fermilab), known as the Fermilab muon g-2 experiment. Due to commence in 2017, this new experiment is expected to improve the experimental measurement precision of $a_\mu$ by a factor of 4, and is seeking to confirm or reject the current discrepancy. The experiment, like its BNL predecessor, will measure the precession of the $\mu^{+}$ spin in a magnetic storage-ring. This new experiment has three straw tracking detectors used to measure the beam profile of the stored $\mu^{+}$, as well as other dynamic properties of the beam. This thesis describes the design of these detectors, and the data acquisition system and subsequent data processing systems that have been developed to read them out and make their data available for physics analysis. The performance of the straw trackers and the readout systems at a number of beam tests and test stands is presented, in addition to Monte-Carlo simulations of the trackers in the final experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large area liquid argon detectors for interrogation systems

Measurements of the efficiency, pulse shape, and energy and time resolution of liquid argon (LAr) detectors are presented. Liquefied noble gas-based (LNbG) detectors have been developed for the detection of dark matter and neutrinoless double-beta decay. However, the same qualities that make LNbG detectors ideal for these applications, namely their size, cost, efficiency, pulse shape discrimination and resolution, make them promising for portal screening and the detection of Special Nuclear Materials (SNM). Two 18-liter prototype detectors were designed, fabricated, and tested, one with pure LAr and the other doped with liquid Xe (LArXe). The LArXe detector presented the better time and energy resolution of 3.3 ns and 20% at 662 KeV, respectively. The total efficiency of the detector was measured to be 35% with 4.5% of the total photons detected in the photopeak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cherenkov neutron detector for fusion reaction and runaway electron diagnostics

A Cherenkov-type neutron detector was newly developed and neutron measurement experiments were performed at Korea Superconducting Tokamak Advanced Research. It was shown that the Cherenkov neutron detector can monitor the time-resolved neutron flux from deuterium-fueled fusion plasmas. Owing to the high temporal resolution of the detector, fast behaviors of runaway electrons, such as the neutron spikes, could be observed clearly. It is expected that the Cherenkov neutron detector could be utilized to provide useful information on runaway electrons as well as fusion reaction rate in fusion plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress, Performance, and Prospects of Ultra-High Resolution Microcalorimeter Spectrometers

In 2005 the LANL/NIST team used a single high-resolution microcalorimeter detector to measure the gamma-ray spectrum of a plutonium sample. After more than a decade of research and development on this topic, both the technology and our general understanding of its capabilities have advanced greatly, such that a progress review is now timely. We examine the scenario of a large-scale reprocessing plant and conclude that current non-destructive analysis (NDA) methods are inadequate to safeguard such a facility to the desired levels, leading to undesirable dependence on massspectrometry (MS) destructive analysis (DA). The development of microcalorimeter detectors is intended to close the performance gap between NDA and DA methods to address the needs of nuclear facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Measurement of the Attenuation of Drifting Electrons in the MicroBooNE LArTPC

MicroBooNE, an 85-ton active mass liquid-argon time-projection chamber (LArTPC) detector located on the Fermilab’s Booster Neutrino Beamline (BNB), is designed to both probe neutrino physics phenomena and further develop the LArTPC detector technology. MicroBooNE, the largest currently operating LArTPC detector in the world, began collecting data in fall 2015. The exceptional imaging capabilities of LArTPCs allow unprecedented study of neutrino interactions. A fundamental requirement for the performance of such detectors is to maintain electronegative contaminants such as oxygen and water at extremely low concentrations, which otherwise can capture the ionization electrons. This note presents a first measurement of the electron attenuation as a function of drift time, using cosmic ray muon data collected by MicroBooNE. The observed electron attenuation indicates that during stable purity period, the lowest electron drift-lifetime observed is 18.0 ms which corresponds to a charge loss of 12% over the full drift distance at an electric field of 0.273 kV/cm and an O 2 equivalent contamination of 17 ppt. This is an indication that the argon purification and recirculation system of MicroBooNE is performing successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a novel four-dimensional diode array

Purpose: The aim of this work is to develop effective calibration methods for a novel four-dimensional (4D) diode array for pretreatment verification of intensity-modulated radiation therapy (IMRT) and rotational therapy. Methods: A novel 4D diode array (ArcCHECK, Sun Nuclear, Melbourne, FL) was developed to meet the needs of appropriate and efficient quality assurance for IMRT and especially rotational radiotherapy. The diode array presents a consistent detector image in beam's eye view at arbitrary gantry angles due to isotropic arrangement of diodes in a three-dimensional (3D) cylindrical phantom. The 50 ms simultaneous update of all diodes on the detector array (fourth dimension) makes it capable of time-resolved beam delivery analysis with any rotational delivery techniques. The calibration procedure consisted of delivering and measuring a series of calibration beams with 5.8 deg. angular spacing surrounding the cylindrical diode array. Correction factors for diode intrinsic sensitivity and directional response dependence were derived from these measurements. A real-time algorithm to derive gantry angles based on the detector signal was developed to interpolate and apply the corresponding angular correction factors. Results: The calibration was validated with ion chamber scanned beam profiles in a 3D water tank. Excellent agreement was observed between diode array measurement and treatment planning system calculation. The accuracy of the gantry angle derivation algorithm was within 1 deg. which caused a less than 0.2% dosimetric uncertainty. Conclusions: With the proposed calibration method and the automatic gantry angle derivation algorithm, the 4D diode array achieved isotropic detector response and is suitable for both IMRT and rotational therapy pretreatment verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a new flux map processing code for moveable detector system in PWR

This paper presents an introduction to the development of the flux map processing code MAPLE developed by China Nuclear Power Technology Research Institute (CNPPJ), China Guangdong Nuclear Power Group (CGN). The method to get the three-dimensional 'measured' power distribution according to measurement signal has also been described. Three methods, namely, Weight Coefficient Method (WCM), Polynomial Expand Method (PEM) and Thin Plane Spline (TPS) method, have been applied to fit the deviation between measured and predicted results for two-dimensional radial plane. The measured flux map data of the LINGAO nuclear power plant (NPP) is processed using MAPLE as a test case to compare the effectiveness of the three methods, combined with a 3D neutronics code COCO. Assembly power distribution results show that MAPLE results are reasonable and satisfied. More verification and validation of the MAPLE code will be carried out in future. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron/hadron separation with the TRD based on GaAs pixel detectors

Transition Radiation Detectors (TRDs) are widely used for particle identification in both high-energy physics and astroparticle physics. They are typically equipped with gaseous detectors. The main limitation of these types of detectors is that TR photons and ionization losses cannot be decoupled, which significantly reduces the particle separation power. Recent advancements in the development of pixel detectors based on GaAs sensors offer a unique opportunity to effectively detect TR photons and separate them from ionization losses. Such detectors represent novel devices that combine precise tracking capabilities with particle identification (PID) properties. The present work is dedicated to an experimental study of particle identification properties of the TRD prototype based on 500 μ m-thick GaAs sensor bonded to a Timepix3 chip. Studies were performed at the CERN SPS and it was shown that at a particle momentum of 20 GeV/c, the probability of misidentifying a hadron as an electron is below 10 −2 for an electron detection efficiency of 98%–99%, and it is 1 . 6⋅10 −4 for electron detection efficiency of 90%. This performance surpasses the electron/hadron rejection power of all known TRDs by an order of magnitude for the same detector length.

GaAs detectors↗

Characteristic Performance Evaluation of a new SAGe Well Detector for Small and Large Sample Geometries

Environmental scientific research requires a detector that has sensitivity low enough to reveal the presence of any contaminant in the sample at a reasonable counting time. Canberra developed the germanium detector geometry called Small Anode Germanium (SAGe) Well detector, which is now available commercially. The SAGe Well detector is a new type of low capacitance germanium well detector manufactured using small anode technology capable of advancing many environmental scientific research applications. The performance of this detector has been evaluated for a range of sample sizes and geometries counted inside the well, and on the end cap of the detector. The detector has energy resolution performance similar to semi-planar detectors, and offers significant improvement over the existing coaxial and Well detectors. Energy resolution performance of 750 eV Full Width at Half Maximum (FWHM) at 122 keV γ-ray energy and resolution of 2.0 - 2.3 keV FWHM at 1332 keV γ-ray energy are guaranteed for detector volumes up to 425 cm{sup 3}. The SAGe Well detector offers an optional 28 mm well diameter with the same energy resolution as the standard 16 mm well. Such outstanding resolution performance will benefit environmental applications in revealing the detailed radionuclide content of samples, particularly at low energy, and will enhance the detection sensitivity resulting in reduced counting time. The detector is compatible with electric coolers without any sacrifice in performance and supports the Canberra Mathematical efficiency calibration method (In situ Object Calibration Software or ISOCS, and Laboratory Source-less Calibration Software or LABSOCS). In addition, the SAGe Well detector supports true coincidence summing available in the ISOCS/LABSOCS framework. The improved resolution performance greatly enhances detection sensitivity of this new detector for a range of sample sizes and geometries counted inside the well. This results in lower minimum detectable concentrations compared to Traditional Well detectors. The SAGe Well detectors are compatible with Marinelli beakers and compete very well with semi-planar and coaxial detectors for large samples in many applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a New Clearance Monitor for Exemption of NPP Radioactive Wastes and its Performance Test - 17200

In nuclear power plants, it is common practice to clear radioactive wastes for free release by using clearance monitor with plastic scintillation detectors so as to reduce disposal costs. These monitors are possible in part thanks to the excellent detection levels achievable with high energy and high yield photons emitted from contaminants such as Cs-137 and Co-60. However, it is difficult for the monitors to separate Naturally Occurring Radioactive Materials (NORM) from the radioactive wastes because the plastic scintillation detectors have poor resolution compared to NaI or HPGe detectors. KHNP has developed a new clearance monitor for determining whether or not the radioactivity level of metal scraps satisfies regulatory criteria. The monitor is composed of 12 large area plastic scintillation detectors and 3 NaI scintillation detectors. The measuring chamber is surrounded by a 5 cm-thick lead shield with chamber dimensions of 1.5 m x 1.0 m x 1.0 m. Its algorithm has a function of measuring total gamma activity while analyzing gamma nuclides and identifying 27 hotspots in radioactive wastes. The detection limit of this system, according to the MCNP simulation, was determined to be about 45 Bq for Co-60 and 78 Bq for Cs-137 with the condition of an empty chamber and measuring time of 1 minute. We evaluated the self - shielding effect of waste for background correction factor and waste height (volume in the chamber) correction factor. We also tested its MDA, location determination of hot-spots, temperature compensation function and convenience of operation. In the future, we will plan to install it at a nuclear site for more tests including evaluating its durability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of Tantalum STJ X-ray Detectors at Elevated Count Rates

Here, we have developed an X-ray detector system based on Ta superconducting tunnel junctions (STJs) with an energy resolution below 10 eV under 1 keV. A principal advantage of STJs over other low-temperature detectors is their high count rate capability. In this work, we have optimized the operating conditions and digital pulse processing parameters for input count rates up to 25 kcps/pixel. Resolution below 10 eV is maintained up to 2.5 kcps/pixel, and at input rates of 25 kcps per pixel the resolution is 26 eV FWHM at 525 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗