Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of Power System Black Start with Hydropower Generator and Battery Energy Storage: Preprint

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a blackstart- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFMcontrolled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active control of resistive wall mode via modification of external tearing index

Modification of the external tearing index, Δ ext ′ , by magnetic feedback is analytically investigated for the purpose of controlling the resistive plasma resistive wall mode (RP-RWM). The matching method is pursued by deriving expressions for the close-loop Δ ext ′ and by linking it to the counterpart from the inner layer. Various feedback coil configurations are found to generally reduce Δ ext ′ and stabilize the RWM, with either proportional or derivative control. Feedback modification of Δ ext ′ is found to be generally independent of the inner layer resistive interchange index D R , confirming that feedback action primarily modifies the solution in the outer ideal region for the RP-RWM. Exception occurs when either the inner layer favorable curvature effect becomes sufficiently large or the feedback action is sufficiently strong to introduce a rotating RP-RWM in the static plasma, leading to complex-valued close-loop Δ ext ′ . The perturbed magnetic energy dissipation in the outer region, associated with the eddy current in the resistive wall, is identified as the key physics reason for feedback induced complex Δ ext ′ . Similar results are also obtained for active control of the external kink instability, whose open-loop growth rate is significantly reduced by inclusion of the plasma resistivity. Within the single poloidal harmonic approximation, which is most suitable for the matching approach, external active coils combined with poloidal sensors are often found to be more efficient for feedback stabilization of the mode at large proportional gain values. This counter-intuitive result is explained as the lack of (non-resonant) poloidal harmonics for proper description of the feedback coil geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Manipulating Ferroelectric Topological Polar Structures with Twisted Light

Abstract The dynamic control of non‐equilibrium states represents a central challenge in condensed matter physics. While intense terahertz fields drive metal‐insulator transitions and ferroelectricity via soft phonon modes, recent theory suggests that twisted light with orbital angular momentum (OAM) offers a distinct route to manipulate ferroelectric order and stabilize topological excitations including skyrmions, vortices, and Hopfions. Control of ferroelectric polarization in quasi‐2D CsBiNb 2 O 7 (CBNO) is demonstrated using non‐resonant twisted ultra‐violet (UV) light (375 nm, 800 THz). Combining in situ X‐ray Bragg coherent diffractive imaging (BCDI), twisted optical Raman spectroscopy, and density functional theory (DFT), three‐dimensional (3D) ionic displacements, strain fields, and polarization changes are resolved in single crystals. Operando measurements reveal light‐induced strain hysteresis under twisted light–a hallmark of nonlinear, history‐dependent ferroelastic switching driven by OAM. Discrete, irreversible domain transitions emerge as the topological charge ℓ is cycled, stabilizing non‐trivial domain textures including vortex‐antivortex pairs, Bloch/anti‐Bloch points, and merons. These persist after OAM removal, indicating a memory effect. Competing mechanisms are discussed, including multiphoton absorption, strain‐mediated polarization switching, and defect‐wall interactions. The findings establish structured light as a tool for deterministic, reversible control of ferroic states, enabling optically reconfigurable non‐volatile devices.

Chemistry↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design Power Control Strategies of Grid-Forming Inverters for Microgrid Application

This paper develops and compares two control schemes in the application control layer of a non-phase-locked loop (non-PLL) grid-forming (GFM) inverter to gain insight and understanding into how the two schemes affect the dynamic responses of GFM inverters and the transition operation of microgrids. The first scheme adopts power tracking based on an outer current loop in grid-connected mode and droop control in islanded mode, and the second uses droop control in both grid-connected and islanded modes. Analytical study is developed to compare the performance of these two strategies from various aspects, including fundamental differences, transition operation, power tracking, and P-Q capability with low point-of-common-coupling (PCC) voltages. Extensive simulation testing is carried out to validate the control performance of these two control strategies, and the simulation testing confirms the findings of the analytic study. Finally, the second strategy is recommended because of its superior control performance and ease of implementation. The analysis and results are useful in developing reliable control schemes for non-PLL GFM inverters because increasing numbers of inverters will work as non-PLL grid-forming sources in future grids because of their improved stability and reliability.

grid-forming↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Report on Compositional Specification for Printed 316SS

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development and deployment of advanced materials and components fabricated via additive manufacturing (AM). A key challenge for the widespread adoption of AM is the variability in material properties, which can originate from powder feedstock, process parameters, geometry, and the machine. AM powder feedstock compositions are based on those developed for conventional manufacturing. However, the smaller melt pools combined with multiple melt cycles over the course of a build can have substantial effects on the local phase selection resulting from minor batch-to-batch feedstock variability. Therefore, this report focuses on coupling CALPHAD calculations with data mining and visualization to aid the development of compositional specifications for stainless steel 316, an important alloy for nuclear applications and suitable for AM. This work reports that δ-ferrite formation has a stronger dependence on the amount of nickel in the alloy despite nickel being an austenite stabilizer. These findings show the need for exercising a tighter control on the amount of nickel in the alloy compared with the amount of chromium, which is a ferrite stabilizer.

36 MATERIALS SCIENCE↗

Safe Physics-Informed Machine Learning for Dynamics and Control

This tutorial paper focuses on safe physics-informed machine learning in the context of dynamics and control, providing a comprehensive overview of how to integrate physical models and safety guarantees. As machine learning techniques enhance the modeling and control of complex dynamical systems, ensuring safety and stability remains a critical challenge, especially in safety-critical applications like autonomous vehicles, robotics, medical decision-making, and energy systems. We explore various approaches for embedding and ensuring safety constraints, including structural priors, Lyapunov and Control Barrier Functions, predictive control, projections, and robust optimization techniques. Additionally, we delve into methods for uncertainty quantification and safety verification, including reachability analysis and neural network verification tools, which help validate that control policies remain within safe operating bounds even in uncertain environments. The paper includes illustrative examples demonstrating the implementation aspects of safe learning frameworks that combine the strengths of data-driven approaches with the rigor of physical principles, offering a path toward the safe control of complex dynamical systems.

Drgona, Jan↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilizing biochars to stabilize mercury in contaminated floodplain sediment: Implications on mercury remediation

Major weather events contribute to the mobility and remobilization of legacy mercury (Hg) contamination and sequestration within sediments. Remediation using biochar as a soil amendment is a useful technique to immobilize and decrease Hg toxicity. This study explored whether biochar application is effective at stabilizing labile mercury (LaHg) from floodplain sediment. Controlled mesocosms simulating contamination events and flooding conditions were conducted. Floodplain sediment, which experiences annual periodic flooding, was collected. Sediment was spiked with inorganic Hg, applied with different types of biochar, and experienced simulated flooding events. Four types of biochar, pure rice husk (RH), pure peanut hull (PH), sulfur-modified rice husk (SMRH), and sulfur-modified peanut hull (SMPH), were applied at 10 and 40 g/kg rates (i.e., RH 10, RH 40; PH 10, PH 40, SMRH 10, SMRH 40, SMPH 10, SMPH 40). Total Hg, methylmercury, and LaHg concentrations were analyzed by coupling with redox potential measurements. Results indicate that SMRH 10, PH 10, PH 40, SMPH 10, and SMPH 40 successfully remediate Hg by stabilizing and reducing LaHg species from floodplain sediment. However, a high Hg methylation potential was observed with unsulfated and sulfated peanut hulls (PH 10, PH 40, SMPH 10, and SMPH 40), as they tend to create a reducing microenvironment that favors sulfate reduction reactions. Additionally, sulfur-modified biochar tends to promote Hg methylation potential at high application rates (i.e., 40 g/kg). We thus recommend using SMRH at a relatively low application rate (SMRH 10) for the remediation of Hg from floodplain sediment.

54 ENVIRONMENTAL SCIENCES↗

A Convex Data-Driven Approach for Nonlinear Control Synthesis

We consider a class of nonlinear control synthesis problems where the underlying mathematical models are not explicitly known. We propose a data-driven approach to stabilize the systems when only sample trajectories of the dynamics are accessible. Our method is built on the density-function-based stability certificate that is the dual to the Lyapunov function for dynamic systems. Unlike Lyapunov-based methods, density functions lead to a convex formulation for a joint search of the control strategy and the stability certificate. This type of convex problem can be solved efficiently using the machinery of the sum of squares (SOS). For the data-driven part, we exploit the fact that the duality results in the stability theory can be understood through the lens of Perron–Frobenius and Koopman operators. This allows us to use data-driven methods to approximate these operators and combine them with the SOS techniques to establish a convex formulation of control synthesis. The efficacy of the proposed approach is demonstrated through several examples.

97 MATHEMATICS AND COMPUTING↗

Controlled Dy-doping to nickel-rich cathode materials in high temperature aerosol synthesis

Layered nickel-rich materials are promising next-generation cathode materials for lithium ion batteries due to their high capacity and low cost. However, the poor thermal stability and longtime cycling performance hinders the commercial applications of high nickel materials. Doping with heteroatoms has been an effective approach for improving electrochemical performance of cathode materials. Controlling doping concentration and geometrical distribution is desired for optimal electrochemical performance, but it is challenging in traditional co-precipitation methods. In this work, controlled dysprosium (Dy) doping to NCM811 was studied in an aerosol synthesis method by controlling the precursor concentrations and heating parameters. The obtained materials were characterized by SEM, XRD, and XPS, and their electrochemical properties and thermal stability were evaluated. By controlling the doping concentration (1.5%), Dy-doped NCM811 was improved simultaneously in long-term cycling and high-rate performance. Here, the thermal-chemical stability of the Dy-doped cathode materials was examined in a microflow reactor with a mass spectrometer. The results showed that Dy-doping shifted the O 2 onset temperature to a higher temperature and reduced O 2 release by 80%, thus dramatically increasing the thermal-chemical stability and improving the fire safety of cathode materials. Since high temperature aerosol synthesis is a low-cost and scalable method, the findings in this work have broad implications for commercial synthesis of novel materials with controlled doping modification to achieve high electrochemical performance and safety in lithium ion batteries.

25 ENERGY STORAGE↗

Open-Loop Control Co-Design of Semisubmersible Floating Offshore Wind Turbines Using Linear Parameter-Varying Models

Here, this paper discusses a framework to design elements of the plant and control systems for floating offshore wind turbines in an integrated manner using linear parameter-varying models. Multiple linearized models derived from aero-elastic simulation software in different operating regions characterized by the incoming wind speed are combined to construct an approximate low-fidelity model of the system. The combined model is then used to generate open-loop, optimal control trajectories as part of a nested control co-design strategy that explores the system’s power production and stability using the platform pitch tilt as a proxy in the context of crucial plant and control design decisions. The radial distance between the central and outer columns and the diameter of the outer columns of the semisubmersible platform are the plant design variables. The platform stability and power production are studied for different plant design decisions. The effect of plant decisions on subsequent power production and stability response of the floating wind turbine is quantified in terms of the levelized cost of energy. The results show that the inner-loop constraints and the plant design decisions affect the turbine’s power and, subsequently, the cost of the system.

17 WIND ENERGY↗

Temperature dependent interfacial microstructure in HIP-bonded Al6061/Zr joints

Pressing (HIP) at 450 °C and 560 °C under 103 MPa for 90 minutes to evaluate interfacial diffusion and microstructural evolution. Sound metallurgical bonding was achieved at both temperatures, with Zr serving as an effective diffusion barrier. Microstructural analysis revealed the the formation of a (Al,Si)3Zr intermetallic layer at the Al/Zr interface, whose thickness increased from ~100 nm at 450 °C to ~2100 nm at 560 °C, consistent with temperature-driven diffusion kinetics. The thin and continuous reaction layer observed at 450 °C indicates controlled interdiffusion and minimal reaction zone growth, favorable for maintaining interface stability and ductility. At 560 °C, enhanced atomic mobility led to pronounced intermetallic development, confirming diffusion-controlled growth behavior. These results provide valuable insights for optimizing Al/Zr interface design and diffusion barrier performance in advanced structural and energy systems.

Al/Zr interface↗

State-Constrained Grid-Forming Inverter Control for Robust Operation of AC Microgrids

The control of grid-forming inverters has become an important problem to achieve high efficiency, reliability, and resilience of the future power grid. The distributed control that utilizes a sparse communication network has been proposed for AC microgrids, in which each DG only has access to the information of a small number of its neighboring DGs, reducing the computational complexity and improving the resiliency to faults and unknown parameters. However, these approaches have not provided a clear analysis of the coupling between active/reactive power injections and the voltage magnitude/frequency or a distributed updating law with a solid theoretical foundation. Additionally, in the existing approaches, tracking the references from the secondary control may violate operational constraints.

Xu, Ying↗

Building Automation

In this chapter, we focus on both need-based and vision-based control innovation for building automation for HVAC systems. After providing a brief background that describes different HVAC architectures and products, we describe the control challenges and opportunities from a needs-based point of view, at the equipment level, the systems level, and the building level. At the equipment level, increased use of continuously variable actuation such as variable speed compressors and fans, requires application of robust multivariable control that must consider various types of nonlinear behavior across increasingly larger operating envelopes. The objective at this level is to achieve robust and energy efficient operation. At the system level, coupled and interactive dynamics among subsystems are increasingly important to consider, and functional integration of these subsystems, along with set points and operating schedules are designed to minimize energy consumption and improve occupant comfort. At the building level, issues such as integration among other building systems, such as the building envelope and the electric grid, offer opportunities to develop new types of demand response and grid-interactive behaviors and technologies. At the higher levels, system dynamics and robust stability are less of an issue, similar to process control applications, while optimization and integration are more important, although dynamic stability is increasing an issue at the higher levels too. From a vision-driven innovation point of view, we describe three areas that will require sustained research efforts and will eventually impact building automation: Digital Twins, Model Predictive Control, and Grid Interactive Buildings.

Bortoff, Scott↗