Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Evaluation of Visualization Using a 50/50 (Contrast Media/Glucose 5% Solution) Technique for Radioembolization as an Alternative to a Standard Sandwich Technique

BackgroundRadioembolization (RE) with {sup 90}yttrium ({sup 90}Y) resin microspheres generally employs a sandwich technique with separate sequential administration of contrast medium (CM), followed by vehicle (e.g., glucose 5% [G5] solution), then {sup 90}Y resin microspheres (in G5), then G5, and then CM again to avoid contact of CM and microspheres under fluoroscopic guidance. This study evaluates the visualization quality and safety of a modified sandwich technique with a 50/50-mixture of CM (Imeron 300) and G5 for administration of {sup 90}Y resin microspheres.Materials and MethodsA retrospective analysis of 81 RE procedures in patients with primary or secondary liver tumors was performed. The quality of angiographic visualization of the hepatic vessels was assessed before the first injection and immediately before the whole dose has been injected. Visualization and flow rate were graded on a 5-point scale: 1 = very good to 5 = not visible/no antegrade flow. Univariate logistic regression models and multiple linear regression models were used to evaluate the prognostic variables associated with visualization and flow scores.ResultsVisualization quality was inversely related to flow rate, the lower the flow rate the better the grade of the visualization. Visualization quality was also inversely related to body-mass-index (BMI). Performing RE with the 50/50-CM/G5 mixture resulted in a mean injection time for 1 GBq of 15 min. No clinically significant adverse events, including radiation-induced liver disease were reported.ConclusionRE with a 50/50-mixture of CM and G5 for administration of {sup 90}Y resin microspheres in a modified sandwich technique is a safe administration alternative and provides good visualization of hepatic vessels, which is inversely dependent on flow rate and BMI. Injection time was reduced compared with our experience with the standard sandwich technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Viewing internal bubbling and microexplosions in combusting metal particles via x-ray phase contrast imaging

The combustion performance of metal particles for explosives, propellants, pyrotechnics, and bio-agent defeat can be optimized by controlling the chemistry, size, and coatings of the particles. Many pure and composite metal fuels used in these applications have been observed to microexplode during combustion. This causes particles to fragment, revealing fresh surfaces, which may enhance burn rates and efficiencies. Despite these potential benefits, few have attempted to control the bubbling and the microexplosion of metal powders as they combust in molten states. Here, we choose Al:Zr composite powders as a representative system to study bubbling and microexplosions and to identify active mechanisms. Using synchrotron x-rays and phase contrast imaging, we observe molten metal particles of various sizes as they burn in air at temperatures ranging from 2700 to 3500 K. We characterize bubble nucleation and growth in the interior of the particles during the combustion process, and we identify heterogeneous nucleation, slow growth and coalescence of bubbles, as well as rapid bubble growth leading to microexplosions. Bubble growth rates and Laplace pressures are calculated, and we find that during slow expansion growth rates are similar to classical predictions of bubble growth in superheated liquids. For rapid expansions we find that a critical growth rate of ~0.5m s –1 , independent of the initial particle size, is necessary to enable microexplosions. We calculate the rate of gas generation that is needed to enable this growth and we conclude that nitrogen is the gas most likely driving rapid bubble growth and fragmentation. Furthermore these results provide the first in situ observations of the mechanisms that control bubbling and microexplosions during the combustion of metal particles.

36 MATERIALS SCIENCE↗

Investigation of near-field jet stability of a single-hole injector based on fast X-ray phase contrast imaging and image feature matching

Fuel spray is very effective in controlling the combustion process to improve engine performance and reduce emissions. Understanding the spray unstability during the injection process is of importance to improve the control of spray characteristics and engine operation. In this study, near-field biodiesel jets were recorded using fast X-ray phase contrast imaging and the flow features inside the jet were extracted using Speeded Up Robust Features (SURF) method. Here, the image similarity by feature matching was successfully used to represent the near-field jet stability. Based on the jet stability, an injection process can be divided into five stages: an unstable stage at needle opening, a partially stable transition stage at needle opening, a stable stage, a stable transition stage at needle closing and an unstable stage at needle closing. The ranges of needle lift for five stages were also determined. The jet unstability is highly related to the cavitation formation and gas purging process during needle opening. The variation of stable jet feature is dependent on the needle lift at needle closing. Higher needle lift for the similar jet feature at needle opening indicates a hydraulic delay compared to needle closing. Finally, the possible reasons of jet feature formation and feature detection used on the multi-hole injector are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Reduced volume of diabetic pancreatic islets in rodents detected by synchrotron X-ray phase-contrast microtomography and deep learning network

The pancreatic islet is a highly structured micro-organ that produces insulin in response to rising blood glucose. Here we develop a label-free and automatic imaging approach to visualize the islets in situ in diabetic rodents by the synchrotron radiation X-ray phase-contrast microtomography (SRμCT) at the ID17 station of the European Synchrotron Radiation Facility. The large-size images (3.2 mm × 15.97 mm) were acquired in the pancreas in STZ-treated mice and diabetic GK rats. Each pancreas was dissected by 3000 reconstructed images. The image datasets were further analysed by a self-developed deep learning method, AA-Net. All islets in the pancreas were segmented and visualized by the three-dimension (3D) reconstruction. After quantifying the volumes of the islets, we found that the number of larger islets (=>1500 μm 3 ) was reduced by 2-fold (wt 1004 ± 94 vs GK 419 ± 122, P < 0.001) in chronically developed diabetic GK rat, while in STZ-treated diabetic mouse the large islets were decreased by half (189 ± 33 vs 90 ± 29, P < 0.001) compared to the untreated mice. Our study provides a label-free tool for detecting and quantifying pancreatic islets in situ. It implies the possibility of monitoring the state of pancreatic islets in vivo diabetes without labelling.

59 BASIC BIOLOGICAL SCIENCES↗

The Effect of a Contrast Agent on Proton Beam Range in Radiotherapy Planning Using Computed Tomography for Patients With Locoregionally Advanced Lung Cancer

Purpose: We evaluated the effect of a contrast agent (CA) on proton beam range in a treatment planning system (TPS) for patients with locoregionally advanced lung cancer. Methods and Materials: Two sets of computed tomography (CT) images (with and without CA) were obtained from 20 patients with lung cancer. Because the increase in Hounsfield unit ( Increment HU) value of the heart and great vessels due to the effect of CA is most prominent among thoracic structures, to evaluate the effect of CA on proton beam range in the TPS, we compared the calculated distal ranges in the plan with CA-enhanced CT with those with corrected CT, in which the HU values of the heart and great vessels in the CA-enhanced CT were replaced by average HU values obtained from the unenhanced CT. Results: The mean Increment HU value and the longest length of the heart and great vessels within the proton beam path in the field that passed through these structures were 189 {+-} 29 HU (range, 110-250 HU) and 7.1 {+-} 1.1 cm (range, 2.6-11.2 cm), respectively. The mean distal range error in the TPS because of the presence of CA was 1.0 {+-} 0.7 cm (range, 0.2-2.6 cm). Conclusion: If CA-enhanced CT images are used for radiotherapy planning using a proton beam for the treatment of lung cancer, our results suggest that the HU values of the heart and great vessels should be replaced by the average HU values of soft tissue to avoid discrepancies between planned and delivered doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using electron channeling contrast imaging to inform and improve the growth of high-efficiency GaAs solar cells on nanopatterned GaAs substrates

Patterned substrates provide opportunities for reducing the cost of high-efficiency III-V devices by incorporating mechanically weak layers beneficial for substrate reuse (e.g. by spalling). In this work, the functionality of electron channeling contrast imaging (ECCI) as a tool to efficiently understand and mitigate defect formation is exemplified by developing a process in which high-quality III-V material can be grown on nanopatterned GaAs substrates. Reactive ion etching used in the patterning process was found to damage the GaAs substrate surface, leading to the formation of stacking faults in the epitaxial material as observed by ECCI. Etching the patterned substrates in a 1 NH4OH: 1 H2O2: 50 DI H2O solution for 10 s prior to growth removed the substrate surface damage and stacking faults were no longer present. Growth of solar cell device structures initially produced samples with many macroscale flaws creating shunts in the devices, which complicated the assessment of material quality by device measurements. However, ECCI revealed that the epitaxial material surrounding macroscale flaws was free from any crystallographic defects such as stacking faults and threading dislocations. With this knowledge, we focused on refining the patterning process to eliminate the macroscale flaws. Solar cells were then grown on the improved nanopatterned substrates and exhibited device structures with defect densities less than 5 x 105 cm -2 and average conversion efficiency of 24.8%, nearly identical to devices grown on unpatterned epi-ready substrates (25.0%).

14 SOLAR ENERGY↗

Hyperintensity in the Dentate Nucleus on Nonenhanced T1-Weighted Magnetic Resonance Imaging Suggests Dechelation of Contrast Agents

With the exception of renal failure patients, gadolinium-based contrast agents (GBCAs) for magnetic resonance imaging (MRI) have a high tolerance and acceptability in patients needing to undergo an enhanced MRI. Now that enhanced MRIs are becoming increasingly popular and nephrogenic systemic fibrosis cases are becoming a rarity, a common belief is that these GBCAs are essentially “biologically inert” materials. However, recent reports have emerged querying the link between these GBCAs and hyperintensity in the dentate nucleus on unenhanced T1-weighted MRI in some patients. This review article outlines the basic chemistry and characteristics of currently approved GBCAs, summarizes the described research findings of gadolinium deposition in the dentate nucleus, and identifies areas for future research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pore habit of methane hydrate and its evolution in sediment matrix – Laboratory visualization with phase-contrast micro-CT

Describing the pore habit of methane hydrate in sediment matrices is essential for understanding natural distribution of methane hydrate, methane trace (transport and solidification) in the hydrate stability zone, physical properties of hydrate-bearing sediments, and the associated influence on potential gas production. Pore habit visualization in natural media at pore scale even with laboratory synthesized cores has been challenging due to the similar densities of methane hydrate from pore liquid. In this work, we used phase-contrast assisted micro-CT with potassium iodine-doped brine to visualize four phases: sand particles, pore fluid, methane hydrate and methane gas. This study visualizes the pore habit of methane hydrate at various stages including during hydrate formation in excess-gas systems, its evolution after brine injection to replace pore fluid, and hydrate formation in excess-water systems. Hydrate tends to adopt round and smooth surfaces when in contact with water while exhibits relatively angular interfaces when in contact with methane gas. Hydrate formation in excess-gas systems results in a partial cementing and partial mineral-coating pore habit, while hydrate in excess-water systems develops mainly as pore-filling, and locally cementing or mineral-coating where big gas pockets exist at the initial state. Pore liquid replacement from methane gas to brine triggers a shift of hydrate pore habit towards pore-filling. Methane hydrate evolution over time produces bigger hydrate particles but with less contact area with sand particles. The effects of hydrate pore habit become less important as hydrate particle size exceeds the pore size. Additionally, hydrate formation could trap residual methane gas and brine as inclusions.

58 GEOSCIENCES↗

Wetting mechanism and alteration of nano-sized shale pores: Insights from contrast variation small angle neutron scattering

Wettability of tight shale is crucial for fluid flow and mass transport process in energy geosciences. However, understanding the interfacial chemistry and wetting mechanisms at sub-nano-pore scales remains a formidable challenge. Here, in this study, the Contrast Variation technique of Small Angle Neutron Scattering (CV-SANS) is employed to investigate shale’s interfacial chemistry using reagents that possess a range of different polarities, including water, n-decane, toluene, and dimethyl methanamide. Through five different experimental strategies, we have demonstrated a successful modification of shale wettability, ranging from enhancement, weakening, to reversal. Delving into the mechanisms, we illustrated the crucial role of pre-existing liquid films in these changes, where the uniquely co-existing polar and non-polar functional groups in dimethyl methanamide acted as a conduit for interfacial chemistry adjustments. Furthermore, a solvent immersion led to matrix dilation as well as liberation of residual oil-occupied pores, resulting in altered pore size distributions, with hydrogen bonding playing a significant role in the polar groups. Interestingly, despite shale exhibiting a stronger affinity for oil over water, hydrophilic solvents induced more substantial dilation than lipophilic ones. Collectively, this work elucidates the dynamic change of interfacial chemistry via the configuration of polarity using chemical reagents, and the CV-SANS technique underscores its invaluable utilities in decoding the interfacial wettability traits in nanopore space of shale.

58 GEOSCIENCES↗

Multiscale dynamic experiments on fiber-reinforced composites with damage assessment using high-speed synchrotron X-ray phase-contrast imaging

We report fiber-reinforced composites (FRCs) have been widely used as protection materials to replace heavier metals. However, predictive capabilities for the impact-induced failure of FRCs have not been well-developed. In this work, we introduced an integrated technique to visualize the dynamic failure of FRCs, with the modified Kolsky bar loading and the high-speed synchrotron X-ray phase-contrast imaging (PCI). We summarize our experimental studies across the FRCs’ structural levels by using this integrated technique, including single-fiber tensile experiments, fiber/matrix debonding experiments, and single-edge notched bending experiments on composite laminates. It is revealed that the high-speed synchrotron X-ray PCI technique possesses sufficient spatial resolution to identify the failure behavior of a single fiber in the 10-μm scale level, as well as temporal resolution to identify the time sequence of internal dynamic damage evolution. The technique can penetrate through the opaque composite sample and provide real-time visualization of small-scale damaging mechanisms such as the embedded fiber’s sliding in the matrix and the fiber’s transverse debonding with the matrix. At an expanding scale, the technique can identify the crack initiation and track the cracking behavior inside a single ply or between different plies of a composite laminate. High-speed visualization inside the material by this integrated technique provides critical deformation and failure information to develop physical understanding of the damage inside composites under impact.

47 OTHER INSTRUMENTATION↗

Contrast Mechanisms in Secondary Electron e-Beam-Induced Current (SEEBIC) Imaging

Abstract Over the last few years, a new mode for imaging in the scanning transmission electron microscope (STEM) has gained attention as it permits the direct visualization of sample conductivity and electrical connectivity. When the electron beam (e-beam) is focused on the sample in the STEM, secondary electrons (SEs) are generated. If the sample is conductive and electrically connected to an amplifier, the SE current can be measured as a function of the e-beam position. This scenario is similar to the better-known scanning electron microscopy-based technique, electron beam-induced current imaging, except that the signal in the STEM is generated by the emission of SEs, hence the name secondary electron e-beam-induced current (SEEBIC), and in this case, the current flows in the opposite direction. Here, we provide a brief review of recent work in this area, examine the various contrast generation mechanisms associated with SEEBIC, and illustrate its use for the characterization of graphene nanoribbon devices.

47 OTHER INSTRUMENTATION↗

Paramagnetic Mn 8 Fe 4 -co-Polystyrene Nanobeads as a Potential T 1 –T 2 Multimodal Magnetic Resonance Imaging Contrast Agent with In Vivo Studies

In developing a cluster-nanocarrier design, as a magnetic resonance imaging contrast agent, we have investigated the enhanced relaxivity of a manganese and iron-oxo cluster grafted within a porous polystyrene nanobead with increased relaxivity due to a higher surface area. The synthesis of the cluster-nanocarrier for the cluster Mn 8 Fe 4 O 12 (O 2 CC 6 H 4 CH=CH 2 ) 16 (H 2 O) 4 , cross-linked with polystyrene (the nano-carrier), under miniemulsion conditions is described. By including a branched hydrophobe, iso-octane, the resulting nanobeads are porous and similar to 70 nm in diameter. The increased surface area of the nanobeads compared to nonporous nanobeads leads to an enhancement in relaxivity; r 1 increases from 3.8 to 5.2 ± 0.1 mM -1 s -1 , and r 2 increases from 11.9 to 50.1 ± 4.8 mM -1 s -1 , at 9.4 teslas, strengthening the potential for T 1 and T 2 imaging. Several metrics were used to assess stability, and the porosity produced no reduction in metal stability. Synchrotron X-ray fluorescence microscopy was used to demonstrate that the nanobeads remain intact in vivo . In depth, physicochemical characteristics were determined, including extensive pharmacokinetics, in vivo imaging, and systemic biodistribution analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Equation-of-state measured via x-ray phase contrast imaging for Epon 828/DEA epoxy

Epoxies are a broad class of polymer materials often used as adhesive, structural or binding materials. Epon 828 is an epoxy resin that can be polymerized with a variety of curing agents with the choice of curing agent potentially having an effect on the resulting epoxy polymer’s material properties. In this study, the dynamic behavior of Epon 828 epoxy resin cured with diethanolamine (DEA) is investigated through a series of tamped Richtmyer-Meshkov instability (RMI) experiments measured with x-ray phase-contrast imaging. The measured shock and particle velocities are combined with data in the literature to calibrate Mie-Grüneisen equations-of-state (EOS) for portions and combinations of the collective dataset. The calibrated Mie-Grüneisen EOS are validated against particle velocity profiles extracted from published literature using the Eulerian hydrocode CTH. Here, the Mie-Grüneisen EOS fit to only the tamped RMI experimental data presented here most closely follows the particle velocity profile in the published literature.

36 MATERIALS SCIENCE↗

High-speed x-ray phase contrast imaging and digital image correlation analysis of microscale shock response of an additively manufactured energetic material simulant

The performance of energetic materials subjected to dynamic loading significantly depends on their micro- and meso-scale structural morphology. The geometric versatility offered by additive manufacturing opens new pathways to tailor the performance of these materials. Additively manufactured energetic materials (AMEMs) have a wide range of structural characteristics with a hierarchy of length scales and process-inherent heterogeneities, which are hitherto difficult to precisely control. It is important to understand how these features affect AMEMs’ response under dynamic/shock loading. Therefore, temporally and spatially resolved measurements of both macroscopic behavior and micro- and meso-level processes influencing macroscopic behavior are required. In this paper, we analyze the shock compression response of an AMEM simulant loaded under several impact conditions and orientations. Furthermore, x-ray phase contrast imaging (PCI) is used to track features across the observed shock front and determine the linear shock velocity vs particle velocity equation of state, as well as to quantify the interior deformation fields via digital image correlation (DIC) analyses. Photon Doppler velocimetry is simultaneously used to measure the particle velocities of the specimens, which are consistent with those obtained from x-ray PCI. The DIC analyses provide an assessment of the average strain fields inside the material, showing that the average axial strain depends on the loading intensity and reaches as high as 0.23 for impact velocities up to 1.5 km/s. The overall results demonstrate the utility of x-ray PCI for probing “in-material” equation of state and interior strains associated with dynamic shock compression behavior of the AMEM simulant.

3D printing↗

A Pockels cell enabled heterodyne phase contrast imaging diagnostic for detection of ion cyclotron emission

This work describes a novel optical heterodyne detection scheme that significantly extends the frequency response of the phase contrast imaging method to detect electron density fluctuations in tens of megahertz frequency range. The system employs a variable frequency electro-optic modulator to allow operation at any frequency in the range 10–40 MHz without the need to realign the system. The frequency coverage of the system makes it suitable to measure the radial structure of the electron density component of ion cyclotron emission on devices having confining magnetic field of a few tesla, thus extending the purely temporal measurements provided so far by magnetic probes.

47 OTHER INSTRUMENTATION↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗