Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condensation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Effect of Strength of Soluble and Solid Acid Catalysts on Selectivity in Aldol Reactions

Aldol reactions can follow the classical condensation path and produce an α,β-unsaturated carbonyl compound and water, however in some cases, aldol chemistry may be steered towards a fission that gives an olefin and a carboxylic acid. This investigation examines how the strength of Brønsted acid sites—both in homogeneous and heterogeneous catalysis—controls these two pathways and their kinetics. The cross-aldol reaction between benzaldehyde and 3-pentanone served as test case. Batch reactions, conducted in toluene as solvent at a temperature of 140 °C under autogenous pressure, were analyzed by GC and in situ ATR-FTIR spectroscopy to determine product distributions and rate constants for condensation and fission pathways. A series of soluble acids including a family of sulfonic acids mostly favored the condensation pathway, with formic acid as the weakest in the series by its pKa being inactive for aldol chemistry. Significant amounts of fission products were rare except for the known selectivity of phosphoric acid, and the circumstances were difficult to delineate. For the sulfonic acid family, the logarithm of the first-order condensation rate constants scaled only roughly with pKa (water) values, whereas a good correlation was obtained with calculated deprotonation Gibbs energies in toluene. A series of H-forms of isomorphously substituted beta zeolites, HESiBEA with E = Al, Ga, Fe, or B, favored the fission pathway. Site density and site strength were characterized by calorimetric measurements of the heats of adsorption of isopropylamine, which decreased in the order Al > Ga, Fe > B. The logarithm of the site-normalized first-order fission rate constants scaled roughly with the heats of adsorption and correlated excellently with reported deprotonation energies. In conclusion, acid strength mainly affects activity and can be seen as a pre-requisite for either aldol condensation or fission chemistry, whereas additional, yet to be full clarified catalyst properties and reaction conditions are required to steer aldol chemistry towards fission selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sticking Coefficients of Fusion Reactor Impurities from Molecular Dynamics Simulations for the Design of Cryopumps

A cryopump can be utilized as an impurity removal component of a direct internal recirculation (DIR) system for the fusion fuel cycle. The DIR facilitates a low fuel inventory by continuously pumping unburnt fuel while removing impurities from the fusion exhaust stream. A cryopump can target multiple impurity species by maintaining a temperature lower than the gas triple-point temperature that promotes desublimation. The desublimation/condensation of gases in cryopumps can be characterized by the sticking coefficient, which is defined as the probability for a gas particle to stick to a (cryo-)surface upon collision. The sticking coefficient is one of the important design/operation parameters for cryopumps, and it depends on a variety of surface and gas properties. Here, in this study, molecular dynamics simulations were utilized to estimate the sticking coefficients of typical fusion gas impurity species N 2 , CO 2 , and CH 4 over a Cu surface for a range of gas temperatures and surface coverages. The molecular dynamics study showed that the sticking coefficients for gases decrease with an increase in gas temperature. The presence of a single full monolayer of condensate on the metallic surface showed an adverse effect on the sticking of gases; however the sticking improved with two full monolayers of condensate on the surface. The sticking of gases over the mixed condensate on a surface was more favorable than the condensate of the same species for N 2 and CH 4 , with an exception for CO 2 , which showed a decrease in sticking over the mixed condensate.

cryopump↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

Modeling and Optimal Design of a Desalination System Integrated Between a Glass-Covered Solar Collection Water Chamber and a Heat Dissipating Chimney

Abstract Solar thermal energy is trapped in a glass-covered water chamber/basin to provide the heat for evaporation of brackish water in a novel desalination system. To harvest clean water, a chimney is integrated with the water basin, which draws air into the chamber to be humidified by the vapor and then being ventilated via buoyance force. Uniquely, thermal conductive metal sheet is recommended to make the chimney, which allows the vapor in the humid air condenses easily when flowing up. The condensate at the inner wall of the chimney flows down to be collected as clean water. Mathematical modeling and numerical computation have been carried out to delineate the coupling of the buoyance-force-driven flow with the heat and mass transfer of air and water in the solar collection chamber and the condensation of vapor in the heat-dissipating chimney. The objective of the simulation and optimization of the system is to find the best match of the dimensions of the water chamber with a chimney to maximize the production of clean water and energy efficiency. The model has been used to simulation several cases (of water from 40 °C to 50 °C) with available experimental data from the authors’ previous work, and the agreement was satisfactory. The optimization studies found that there is a maximum air flowrate corresponding to a critical chimney height due to the requirement that the chimney is designated to dissipate heat as much as possible to condense water vapor. With the chimney height greater than the critical height, the airflow rate will have a slight decrease. Nevertheless, higher than a critical height is still needed for a chimney to condense more moisture. Optimized chamber diameters at different chimney heights are provided for reference of optimal system designs.

Engineering↗

Modeling of Glycolate Destruction in the Recycle Collection Tank

The Savannah River Site’s DWPF is being upgraded with the introduction of the NG flowsheet. Glycolic acid has been shown to be a superior alternative to formic acid for sludge processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology, 3) pH stability, and 4) adjustment of melter oxidation/reduction potential. Further, the use of glycolic acid virtually eliminates the potential for catalytic hydrogen generation in DWPF processing DWPF process condensates are collected and returned to the Savannah River Site (SRS) CSTF. The RCT collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle will have a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, Savannah River National Laboratory (SRNL) provided to Savannah River Remediation (SRR) at their request a Task Technical and Quality Assurance Plan (TTQAP) to quantify and mitigate glycolate returns via DWPF’s recycle stream. The request included testing of a process to oxidize glycolate and other organic species that are responsible for hydrogen generation from thermolysis. Following that work SRR provided a Task Technical Request (TTR) that requested process modeling. In 2021 a TTQAP was issued to cover the modeling work. Modeling draws data from laboratory scale studies using chemical simulants and radioactive waste samples. Chemical kinetic modeling was performed to evaluate the feasibility of using sodium permanganate to destroy glycolate in the RCT. The results from the laboratory studies were summarized in a series of reports. Reference 9 is a report of lab scale processing of actual DWPF Slurry Mix Evaporate Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) samples in the SRNL Shielded Cells. Tests at caustic conditions demonstrated sodium permanganate was effective in converting glycolate to oxalate, and permanganate (Mn 7+ ) is reduced to manganate (Mn 6+ ) with no significant formation of carbon dioxide or carbonate. Equation (1) was found to best describe the observed reaction of glycolate with permanganate under nominal (60 to 145 mg/L in RCT) glycolate entrainment conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acetonitrile Destruction and Fate of Organics in the Reverse Osmosis System at the ETF

The Hanford Site Effluent Treatment Facility (ETF) currently treats aqueous waste streams that include condensates from the 242-A evaporator, leachate from the Environmental Restoration Disposal Facility (ERDF), as well as laboratory wastes and, in the future, will treat liquid effluents from the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and Integrated Disposal Facility (IDF) leachate. Liquid effluents from the WTP will have significant concentrations of acetonitrile. Acetonitrile is formed by reaction of nitrates and sugar in the WTP low activity waste (LAW) melters and is prevalent in the submerged bed scrubber (SBS) and wet electrostatic precipitator (WESP) liquid effluents from WTP off-gas treatment. When these liquids are concentrated in the WTP Effluent Management Facility (EMF) evaporator in the direct feed low activity waste (DFLAW) flow-sheet, testing has shown that the majority of the acetonitrile partitions to the evaporator condensate. Since the evaporator condensate is directed to the ETF, this creates a potential issue with the ETF waste acceptance criteria. Consequently, there is a need to validate flow-sheet assumptions on the fate of acetonitrile and other organics within the ETF. The present plan includes the addition of a steam stripper to the ETF to remove acetonitrile. There is, therefore, also a need to determine a suitable method to destroy acetonitrile in the overhead condensate stream from the new steam stripper. Washington River Protection Solutions, LLC (WRPS) previously contracted with Atkins and the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) to perform development and testing work to evaluate potential methods for destruction of acetonitrile in WTP secondary liquid effluents. Based on the results of that work, WRPS requested that follow-on testing be conducted to further evaluate acetonitrile destruction in the steam stripper condensate using ultraviolet oxidation (UV/OX) with persulfate. WRPS also requested testing to assess the rejection rate of organics in the reverse osmosis (RO) system installed in the ETF. This report presents the results from testing to address those needs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of the thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery efficiency, and the acid dew point is a key parameter for this optimization. In this work, we analyze and discuss the theory of the sulfuric acid condensation process and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface, and the surface temperature of the window is slowly decreased until condensation is first observed, yielding an accurate measurement of the dew point. The basis of the instrument is that a collimated beam from a diode laser generates scattered light when encountering surface condensate, and a sophisticated array detector is used to sensitively monitor the light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, we propose a calibration system based on a liquid bubbler, which can generate a stable gas flow with known sulfuric acid dew point, to test the dew point meter. Test results show that the dew point meter can accurately measure the acid dew point over a wide range.

Cheng, Mao↗

Impact of phase state and non-ideal mixing on equilibration timescales of secondary organic aerosol partitioning

Abstract. Evidence has accumulated that secondary organic aerosols (SOAs) exhibit complex morphologies with multiple phases that can adopt amorphous semisolid or glassy phase states. However, experimental analysis and numerical modeling on the formation and evolution of SOA still often employ equilibrium partitioning with an ideal mixing assumption in the particle phase. Here we apply the kinetic multilayer model of gas–particle partitioning (KM-GAP) to simulate condensation of semi-volatile species into a core–shell phase-separated particle to evaluate equilibration timescales of SOA partitioning. By varying bulk diffusivity and the activity coefficient of the condensing species in the shell, we probe the complex interplay of mass transfer kinetics and the thermodynamics of partitioning. We found that the interplay of non-ideality and phase state can impact SOA partitioning kinetics significantly. The effect of non-ideality on SOA partitioning is slight for liquid particles but becomes prominent in semisolid or solid particles. If the condensing species is miscible with a low activity coefficient in the viscous shell phase, the particle can reach equilibrium with the gas phase long before the dissolution of concentration gradients in the particle bulk. For the condensation of immiscible species with a high activity coefficient in the semisolid shell, the mass concentration in the shell may become higher or overshoot its equilibrium concentration due to slow bulk diffusion through the viscous shell for excess mass to be transferred to the core phase. Equilibration timescales are shorter for the condensation of lower-volatility species into semisolid shell; as the volatility increases, re-evaporation becomes significant as desorption is faster for volatile species than bulk diffusion in a semisolid matrix, leading to an increase in equilibration timescale. We also show that the equilibration timescale is longer in an open system relative to a closed system especially for partitioning of miscible species; hence, caution should be exercised when interpreting and extrapolating closed-system chamber experimental results to atmosphere conditions. Our results provide a possible explanation for discrepancies between experimental observations of fast particle–particle mixing and predictions of long mixing timescales in viscous particles and provide useful insights into description and treatment of SOA in aerosol models.

54 ENVIRONMENTAL SCIENCES↗

A Numerical Study on the Energy Performance of a Novel Furnace With Acidic Gas Trap Absorbers

Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.

Laclair, Tim↗

Inverter-Based Operation of Maui: Electromagnetic Transient Simulations

As larger and larger power systems approach and reach 100% inverter-based resource (IBR) operation during some hours of the year, questions arise regarding the stability of such extremely-high IBR power systems, the potential need for grid-forming (GFM) inverter technology, and the potential need for synchronous condensers. Relatedly, questions also arise about the ability of conventional positive sequence power system modeling tools to capture high-IBR system dynamics. This presentation introduces electromagnetic transient (EMT) simulations in PSCAD of the near-future (year 2023) Maui power system at and near 100% IBR operation and compares those simulations to positive sequence (PSSE) simulations. The Maui PSCAD model is parallelized on 30 cores and includes the entire transmission system (>200 three-phase buses), >170 individual and aggregate IBR models, four wind plants, and three synchronous generators plus six synchronous condensers at two locations. We investigate system stability with varying levels of inertia using conventional grid-following IBR controls, and then we investigate the impact of GFM controls on stability. Results suggest that: 1) positive sequence simulations can miss key dynamics in extremely high IBR cases; 2) EMT simulations can also miss key dynamics if inverter inner control dynamics are not modeled; 3) synchronous condensers can stabilize a system in which 100% of the energy is supplied by IBRs, even conventional grid-following IBRs; 4) GFM controls on just some of the IBRs can stabilize a 100% IBR power system, even if that system has zero inertia (i.e. no synchronous condensers, though synchronous condensers may be needed for other purposes such as protection system operations).

41 EE - Solar Energy Technologies Office (EE-4S)↗

Analysis of Electro-static Assisted Air Dehumidification

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 μm in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Ultra efficient turbo-compression cooling systems

Aspects of the present disclosure include a system for turbo-compression cooling. The system may be aboard a marine vessel. The system includes a power cycle and a cooling cycle. The power cycle includes a first working fluid, a waste heat boiler configured to evaporate the working fluid, a turbine, and a condenser. The condenser condenses the working fluid to a saturated or subcooled liquid. The cooling cycle includes a second working fluid, a first compressor configured to increase the pressure of the second working fluid, a condenser configured to condense the second working fluid to a saturated or subcooled liquid after exiting the first compressor, an expansion valve, and an evaporator. The turbine and first compressor are coupled one to the other. The waste heat boiler receives waste heat from engine jacket water and lubricating oil from a ship service generator. The evaporator cools water in a shipboard cooling loop.

Bandhauer, Todd M.↗

Acidic Gas Reduction For Residential Natural Gas Furnace

The United States has more than 119 million homes, and 47% of them rely on natural gas as their primary heating fuel. However, most U.S. homes still use noncondensing units with an annual fuel utilization efficiency (AFUE) of ~80%, rather than efficient condensing furnaces. This is due to the high cost of condensing furnaces, which usually use expensive corrosion resistant super-ferritic stainless steel alloy heatexchangers (HX) to avoid corrosion and fouling acid condensation, along with the cost and difficulty of retrofitting the venting used by the replaced furnace. Here, this article discusses a low-cost acidic gas reduction (AGR) catalyst technology that enables a novel condensing natural gas furnace with an ultraclean (i.e., nearly zero) flue gas and neutral condensate that is environmentally friendly.

03 NATURAL GAS↗

Analysis of New Data of Electro-static Assisted Air Dehumidification Processes

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 m in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Spatial BCS-BEC crossover in superconducting $\textit{p–n}$ junctions

Here, we present a theory of superconducting $\textit{p–n}$ junctions. To this end, we consider a two band model of doped bulk semiconductors with attractive interactions between the charge carriers and derive the superconducting order parameter, the quasiparticle density of states, and the chemical potential as a function of the semiconductor gap $Δ_0$ and the doping level ε. We verify previous results for the quantum phase diagram for a system with constant density of states in the conduction and valence band, which show BCS-superconductor to Bose-Einstein-condensation (BEC) and BEC-to-insulator transitions as a function of doping level and the size of the band gap. Then, we extend this formalism to a density of states which is more realistic for 3D systems and derive the corresponding quantum phase diagram, where we find that a BEC phase can only exist for small band gaps $Δ_0 < Δ ^{\ast}_0$. For larger band gaps, we find rather a direct transition from an insulator to a BCS phase. Next, we apply this theory to study the properties of superconducting $\textit{p–n}$ junctions. We derive the spatial variation of the superconducting order parameter along the $\textit{p–n}$ junction. As the potential difference across the junction leads to energy band bending, we find a spatial crossover between a BCS and BEC condensate, as the density of charge carriers changes across the $\textit{p–n}$ junction. For the two-dimensional system, we find two possible regimes, when the bulk is in a BCS phase, a BCS-BEC-BCS junction with a single BEC layer in the space charge region, and a BCS-BEC-I-BEC-BCS junction with two layers of BEC condensates separated by an insulating layer. In three dimensions we find that there can also be a conventional BCS-I-BCS junction for semiconductors with band gaps exceeding $Δ^{\ast}_0$. Thus, we find that there can be BEC layers in the well controlled setting of doped semiconductors, where the doping level can be varied to change and control the thickness of BEC and insulator layers, making Bose-Einstein condensates thereby possibly accessible to experimental transport and optical studies in solid-state materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superuniversality from disorder at two-dimensional topological phase transitions

We investigate the effects of quenched randomness on topological quantum phase transitions in strongly interacting two-dimensional systems. We focus first on transitions driven by the condensation of a subset of fractionalized quasiparticles (“anyons”) identified with “electric charge” excitations of a phase with intrinsic topological order. All other anyons have nontrivial mutual statistics with the condensed subset and hence become confined at the anyon condensation transition. Furthermore, using a combination of microscopically exact duality transformations and asymptotically exact real-space renormalization group techniques applied to these two-dimensional disordered gauge theories, we argue that the resulting critical scaling behavior is “superuniversal” across a wide range of such condensation transitions and is controlled by the same infinite-randomness fixed point as that of the 2D random transverse-field Ising model. We validate this claim using large-scale quantum Monte Carlo simulations that allow us to extract zero-temperature critical exponents and correlation functions in (2+1)D disordered interacting systems. We discuss generalizations of these results to a large class of ground-state and excited-state topological transitions in systems with intrinsic topological order as well as those where topological order is either protected or enriched by global symmetries. When the underlying topological order and the symmetry group are Abelian, our results provide prototypes for topological phase transitions between distinct many-body localized phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced Anti-Fouling Coatings to Improve the Efficiency of Coal Power Plants

As the total cost of carbon to generate energy has become a global concern, operators are increasingly looking at all parts of the generation cycle to find areas where efficiency gains may be found. It has been long identified that fouling of heat exchangers is a persistent cause of up to 2.5% of global CO 2 emissions. Unfortunately, practice has also demonstrated that unless a powerful economic driver exists to encourage preemptive mitigation of fouling, there will always be a strong tendency for operators to minimize any form of intervention due to high costs and challenges in scheduling downtime. The objective of this proposed research effort was to demonstrate how existing power plants could lower their carbon emissions and significantly improve heat transfer efficiency using new surface treatment materials to control fouling in a variety of heat exchange equipment. The surface treatment material which was optimized and deployed in this effort is now known commercially as HeatX. It is a low-surface energy, water- and oil-repellent, abrasion resistant material which can be applied in-situ to a wide variety of previously worn/used/in-service substrates. Once applied, it provides a barrier against corrosion, scale deposit formation, and biofilm adhesion on the circulating water-containing tube-side. Alternatively, if applied to the tube exterior, the non-wetting nature of the surface was demonstrated to promote dropwise condensation, subsequently lowering condenser backpressure and increasing overall plant efficiency. As part of this cooperative effort, the Department of Energy’s support was crucial to de-risk and demonstrate the concept of HeatX, while validating both the performance and economic benefit in multiple pilot field studies. The HeatX material properties were optimized in this effort for full field applicability to heat exchangers and condensers, and Oceanit developed the necessary procedures and protocols to provide enough material to support extended length, multi-year demonstrations in the power generation, desalination, and refining industries, making this technology broadly applicable and ready for commercial transition. Field deployment case studies at thermal power plants have shown that the HeatX treatment can provide economic savings of up to $15,000 per day for an operator based on avoiding maintenance costs and lowering fuel usage. The complete mitigation of fouling effects can increase the efficiency of equipment by up to 7%, in a field where gains of 0.5% are generally seen as operationally significant. The HeatX treatment has also demonstrated exceptional lifetime and compatibility with a wide variety of seawater and hydrocarbon environments, further increasing both the return on investment and the effective emission reduction. Such efficiency improvements correlate to massive carbon savings. For every 1 GW of capacity, operators can see carbon emissions reductions of 300,000 tons of CO 2 per year. When looking at the bigger picture, improved condenser function across the U.S. has the potential to prevent 221.3 million tons of CO 2 emissions, equivalent to the sequestration capacity of 129 million acres of forest. If applied on a global scale, 1.26 billion metric tons of CO 2 could be averted from the atmosphere, the same amount of carbon sequestrated by 1.5 billion acres of forest annually or 262,000 wind turbines operating annually. As businesses across multiple industries take a more active role in focusing on environmental, social, and governance (ESG) solutions as part of their core business operations, HeatX will be an attractive technology for commercial investment.

01 COAL, LIGNITE, AND PEAT↗