At least 631 records · Page 35

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

14 SOLAR ENERGY↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY2016 Vehicle Systems Annual Progress Report

Vehicle Systems is concerned with advancing light-, medium-, and heavy-duty (HD) vehicle systems to support DOE’s goals of developing technologies for the U.S. transportation sector that enhance national energy security,increase U.S. competitiveness in the global economy, and support improvement of U.S. transportation and energy infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

Los Alamos National Laboratory Ombuds Office Biennial Report FY2017-2018

Visitors contact the Ombuds Office to obtain coaching, explore options, develop strategies, learn about LANL resources, understand formal processes and policies, or request a facilitated discussion/mediation. The number of visitors who contacted the office in FY17 and FY18 was 540 and 555, respectively - the highest annual numbers since FY08. The Ombuds Office supports professional workplace communication and conflict management skills through individual consultations, presentations, the resource library, and special events. Courses are regularly scheduled and available to the LANL workforce. Annually, an average of ~1950 participants attended Ombuds courses, workshops, and talks in FY17-18. The total number of individuals who attended presentations in FY17-18, both internal and external to LANL, was 4005. Staff continue to present annually at the International Ombudsman Association Conferences and New Mexico Alternative Dispute Resolution Symposiums. In this reporting period, the Laboratory Ombudsman was recruited to present communication and negotiation skills courses for several universities and prestigious national science and engineering organizations. The mission of the Ombuds Office is to enhance communication and mitigate conflict. Staff provide expertise, feedback and resources to employees, leaders and organizations in order to strengthen conflict and communication capabilities. A related function of the office is to identify and report trends, without breaching confidentiality or anonymity. Trends and concerns may be raised around policies and procedures - including potential future issues – or concerning unhealthy patterns within an organization. The underpinnings of Organizational Ombuds work at LANL are provided by the International Ombudsman Association (IOA) Standards of Practice, (IOA Standards of Practice, 2009; Code of Ethics, 2007). The four IOA tenets are neutrality/impartiality, independence, confidentiality and informality.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Powering Post-COVID-19 Resilient Recovery with Green Stimulus

As the coronavirus disease (COVID-19) pandemic spread globally in early 2020, many governments enacted lockdown measures as an initial containment response. These lockdowns, while effective in slowing infection rates, have also had substantial economic consequences. A series of supply and demand shocks, workforce and supply chain disruptions, and other impacts of the pandemic and ensuing lockdowns have upended the livelihoods for much of the world's population. This quick read spotlights how green stimulus plans and other recovery measures can support near-term recovery and enable longer-term power system resilience against future threats. The term “green stimulus” encompasses fiscal measures (i.e., governmental tax and spending actions) that support short-term economic activity that enhances environmental and natural resource quality over a longer term. The deployment of energy efficiency (EE) and renewable energy (RE) technologies, as well as associated initiatives (e.g., grid modernization, electrification of transport, and so on) have been demonstrably effective in providing this kind of short-run economic boost while simultaneously strengthening the resilience of the power sector. Along with green stimulus packages, concurrent action on the regulatory side—for example, the development of green building codes, updating grid interconnection standards, creating programs and marketplaces for demand-side efficiency, and others—can be a force multiplier in ensuring that public spending achieves maximum impact in near-term recovery and long-term power sector transformation

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Grizzly Development for Light Water Reactor and Advanced Reactor Applications in Fiscal Year 2021

This report summarizes work performed during Fiscal Year (FY) 2021 at Idaho National Laboratory (INL) for the U.S. Department of Energy’s Nuclear Engineering Advanced Modeling and Simulation (NEAMS) program for the Structural Materials and Chemistry Technical Area in the work package entitled “MS-21IN050106 - Structural Materials - INL.” This effort mainly focused on development and application of capabilities for engineering-scale analysis of nuclear reactor structural components in the Grizzly and BlackBear codes. These efforts include performance improvements and application of models for high-temperature component response, cluster dynamics modeling of precipitation in light water reactor pressure vessel steel, engineering-scale capability development in the areas of concrete simulation and reactor pressure vessel analysis, and preparation for and conducting an independent assessment of the adherence of these codes to software quality standards.

36 MATERIALS SCIENCE↗

PV System Owner's Guide to Identifying, Assessing, and Addressing Weather Vulnerabilities, Risks, and Impacts

The report is designed to help federal facility managers, engineers, contractors, and consultants identify the most common PV system vulnerabilities that could lead from mild to catastrophic loss of PV systems during severe weather events. The guide helps users understand the type and severity of severe weather that can occur at any given location, and provides pre- and post-storm operations and maintenance (O&M) measures that can reduce the potential for damage to a PV system during a severe weather event and help speed the recovery of a PV system damaged during a storm. The guide emphasizes safety in responding to damage from severe weather events.

14 SOLAR ENERGY↗

Atomistic theories and Simulations of Multiferroics

The goal of this award was to build a research program aimed at investigating puzzling complex phenomena in multiferroics, that are systems possessing electric and magnetic dipoles. We first emphasized the study of multiferroic nanostructures, that are 0D, 1D, 2D systems as well as superlattices and then also study multiferroics as a whole, i.e., bulks as well. In order to fully understand such complex systems, we also decided to study magnetic systems and ferroelectrics, both in their nanostructure and bulk forms. For that and in addition to use standard Density Functional Theory codes, we developed and used ab-initio tools that are able to model properties of large supercells (about a million atoms nowadays) at finite temperature and for any mechanical and boundary conditions. We also collaborated with experimentalists to fully understand the systems under study. The whole program resulted in 108 publications that are listed at the end of this report. In the following, I will put an emphasis on some publications before the last award period and also indicate a description of the last award period.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ombuds Office 2023 Biennial Report

The Los Alamos National Laboratory (LANL) Ombuds Charter requires the Ombuds Office to issue a report every two years to the Laboratory Director. The prior Ombuds Biennial Report was published in July of 2021, celebrating 25 years of Ombuds history at the Lab. This 2023 report details office transitions and new initiatives over the past two years, along with our ongoing conflict resolution work of one-on-one discussions, classes, presentations, workshops, and facilitations. The Ombuds Office supports the mission of LANL in myriad ways. We champion the LANL culture statement of “ How we do work is as important as What we do,” and we reinforce LANL’s values of integrity, service, excellence, and teamwork. Accordingly, the mission of the Ombuds Office is to support employees in their work, enhance communication, mitigate conflict, and encourage a positive working environment. The Ombuds Office adheres to the International Ombuds Association’s (IOA) Standards of Practice and Code of Ethics (see Appendix). As such, the Ombuds Office is informal, confidential, impartial, and independent. We do not advocate for managers or employees. We don’t tell people what to do; we don’t give advice. All of our services are voluntary. LANL employees seek out the Ombuds Office as a neutral place where they can collect their thoughts, whether in person, on the phone, or online. We help individuals explore and navigate tough issues. Employees expand their understanding of their options, assess what is within their control, and decide what is in their best interest. The Ombuds Office promotes smart, professional conflict management. This report highlights the work of the Ombuds Office and provides a closer look at both quantitative and qualitative data, including anecdotal information and endorsements. It concludes with a discussion of further opportunities to expand the reach of the Ombuds Office to more LANL employees.

99 GENERAL AND MISCELLANEOUS↗

High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP): Design Guidelines and Specifications for DC Distribution-Based Charging Hub

Managed under U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to design and develop a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration and control approaches for a DC distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for DC-coupled charging hub ('DC hub' for short). This report explains the design, development, and implementation process of the experimental platform for the DC hub. The utilization of DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges establishing the DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products as well as novel, in-house designed solutions to evaluate different use cases at rated power and voltage levels.

33 ADVANCED PROPULSION SYSTEMS↗

Molten Salt Corrosion Tests of Additively Manufactured Stainless Steel 316H

Molten salt reactors (MSRs) have drawn considerable interest due to their favorable safety features, high thermal efficiency, and compatibility with different fuel cycles. Yet, the success of MSRs hinges critically on the performance of structural materials to be used in these aggressive molten salt environments, where corrosion and material compatibility remain primary challenges to long-term reliability. Additively manufactured (AM) nuclear structural materials prompt the use of novel geometries and compositions to enhance material performance and reduce costs of constructing MSRs. The rapid solidification conditions inherent to AM processing impart distinctive microstructural features, including cellular sub-structures, dislocation densities, residual stress, and oxide inclusions, which can influence material performance in MSR components. While the mechanical properties of AM stainless steels have been widely studied, their corrosion behavior, particularly in molten salt environments, has received far less attention. Addressing these needs, the Advanced Materials and Manufacturing Technologies (AMMT) program provides a framework for systematically evaluating how unique microstructures produced by AM processes influence the performance of these materials in these demanding environments and for developing reproducible testing workflows that can support future code qualification efforts and standards development. Bridging this knowledge gap is essential for assessing the viability of AM alloys in MSRs and informing qualification strategies. A further challenge is the absence of standardized protocols for molten salt corrosion testing. Accordingly, this report provides an account of the corrosion evaluation of AM 316H stainless steel in NaCl 2 -MgCl 2 molten salt at 550 °C, with exposure times of 100 and 500 hours. It documents the experimental procedures implemented under the AMMT program, including salt preparation, exposure protocols, and post-test characterization methods, to establish reproducibility and transparency. Importantly, the study examines AM 316H samples in the as-fabricated condition, directly reflecting the surface state most relevant to engineering applications, and compares their behavior to machine-cut surfaces. Overall, preliminary evaluations have noted that surface conditions (e.g. morphology, contamination, etc.) have a noticeable impact on the corrosion resiliency. The impact of the corrosion is difficult to detect at 100h, unless, in the case of AM 316H, the specimen surface is decontaminated. After 500 h, as-fabricated surfaces of AM and wrought 316H display evidence of general versus preferential corrosion attack, respectively. Both AM and wrought 316H machine-cut surfaces exhibit a continuous Cr depletion zone, evident of general corrosion. While the estimated extent of corrosion appears within the same order of magnitude regardless of the surface condition, it is apparent that more predictable behavior is observed on machine-cut surfaces. Nonetheless, further investigation is necessary to fully elucidate the corrosion mechanism under these conditions.

36 - MATERIALS SCIENCE↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Stations Tool for Automated Permitting (S-TAP) User Manual

The Stations Tool for Automated Permitting (S-TAP) is a spreadsheet-based plan review questionnaire designed to help automate and expedite the electric vehicle supply equipment (EVSE) permitting process. This manual goes into detail on the development of the tool and guidance for use cases of the tool.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Activities in Support of Continuing the Service of Nuclear Power Plant Safety-Related Concrete Structures

Nuclear power plant (NPP) concrete structures are described. In-service inspection and testing requirements in the U.S. are summarized. The license renewal process in the U.S. is outlined and its current status provided. Operating experience related to performance of the concrete structures is presented. Basic components of a program to manage aging of the concrete structures are identified and described: (1) Degradation mechanisms, damage models, and material performance; (2) Assessment and remediation: i.e., component selection, in- service inspection, non-destructive examinations, and remedial actions; and (3) Estimation of performance at present or some future point in time: i.e., application of structural reliability theory to the design and optimization of in-service inspection/maintenance strategies, and determination of the effects of degradation on plant risk. Finally, areas are noted where additional research would be of benefit to aging management of nuclear power plant concrete structures.

codes and standards↗

Design, Implementation, and Evaluation of a Hybrid DS/FFH Spread-Spectrum Radio Transceiver

In recent years there has been great interest in using hybrid spread-spectrum (HSS) techniques for commercial applications, particularly in the Smart Grid, in addition to their inherent uses in military communications. This is because HSS can accommodate high data rates with high link integrity, even in the presence of significant multipath effects and interfering signals. A highly useful form of this transmission technique for many types of command, control, and sensing applications is the specific code-related combination of standard direct-sequence modulation with "fast" frequency-hopping, denoted hybrid DS/FFH, wherein multiple frequency hops occur within a single data-bit time. In this paper, we present the efforts carried out at Oak Ridge National Laboratory toward exploring the design, implementation, and evaluation of a hybrid DS/FFH spread-spectrum radio transceiver using a single Field Programmable Gate Array (FPGA). The FPGA allows the various subsystems to quickly communicate with each other and thereby maintain tight synchronization. We also investigate various hopping sequences against robustness to interference and jamming. Experimental results are presented that show the receiver sensitivity, radio data-rate/bit-error evaluations, and jamming and interference rejection capabilities of the implemented hybrid DS/FFH spread-spectrum system under widely varying design parameters.

data rate↗

Laboratories for the 21st Century Best Practices: Energy Recovery in Laboratory Facilities

Laboratories typically require 100% outside air for ventilation at higher rates than other commercial buildings. Minimum ventilation is typically provided at air change per hour (ACH) rates in accordance with codes and adopted design standards including Occupational Safety and Health Administration (OSHA) Standard 1910.1450 (4 to 12 ACH – non-mandatory) or the 2011 American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Applications Handbook, Chapter 16 – Laboratories (6 to 12 ACH). While OSHA states this minimum ventilation rate “should not be relied on for protection from toxic substances released into the laboratory” it specifically indicates that it is intended to “provide a source of air for breathing and for input to local ventilation devices (e.g., chemical fume hoods or exhausted bio-safety cabinets), to ensure that laboratory air is continually replaced preventing the increase of air concentrations of toxic substances during the working day, direct air flow into the laboratory from non-laboratory areas and out to the exterior of the building.” The heating and cooling energy needed to condition and move this outside air can be 5 to 10 times greater than the amount of energy used in most office buildings. In addition, when the required ventilation rate exceeds the airflow needed to meet the cooling load in low-load laboratories, additional heating energy may be expended to reheat dehumidified supply air from the supply air condition to prevent over cooling. In addition to these low-load laboratories, reheat may also be required in adjacent spaces such as corridors that pro-vide makeup air to replace air being pulled into negative-pressure laboratories.

Laboratories, Best Practices, Energy, Facilities↗

Technology Solutions Case Study: High-Performance Walls in Hot-Dry Climates

In this project,the Alliance for Residential Building Innovation (ARBI) team worked with builders in California to implement wall assemblies meeting a U-value lower than 0.050 Btu/h-ft2-°F. ARBI and its project team members helped builders identify preferred wall designs that met the requirements of their architects, structural engineers, and purchasing agents and that were acceptable to their subcontractors. Construction methods were observed and documented and construction costs obtained from builders were used to inform cost estimates for a range of advanced wall system types and insulation types. Wall framing types of 2 × 6 (16- and 24-in. on center [o.c.]) and double stud were modeled in Building Energy Optimization (BEopt™) software with cavity insulation levels ranging from R-19 to R-33 (double stud) and exterior rigid insulation of R-4, R-6, and R-8.

ARBI↗