Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charge distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

EVs@Scale Next-Gen Profiles - EV Profile Capture 2023

As part of the U.S. DOE EVs@Scale consortium Next-Gen Profiles (NGP) project, the profile capture of production electric vehicles undergoing high power charging (HPC) is conducted over a wide range of conditions to explore variance and performance. Charge session parameters are collected from both the electric vehicle (EV) and electric vehicle supply equipment (EVSE) at a rate of 10Hz and entered into a time-series database for analysis. These charge profiles are captured under nominal and off-nominal conditions, exploring the impact of battery state of charge (SOC), battery temperature, vehicle condition, smart charge management (SCM), and EVSE limitations. Nominal conditions are defined to be ideal conditions that should transfer the maximum allowable energy in the minimum possible amount of time. Nominal condition profiles are compared across EVs to characterize state-of-the-art EV charging performance against one another. Off-nominal condition profiles are compared against its nominal condition profile counterpart to highlight the variance across less desirable starting conditions within a single EV. Under nominal conditions, most EVs can achieve the original equipment manufacturer (OEM) rated peak-power and charge times. Peak power across EVs has variance due to the vehicle design, battery topology, charging strategy, etc. These 10-100% nominal preconditioned charge profiles across 13 EVs (11 light-duty (LD), 2 heavy-duty (HD)) were used for analysis in power curve analysis, power distribution, SOC and range comparison, thermal impacts of current draw, battery pack size and energy charged, and ramp rates. Power curve analysis show the uniqueness in power vs time curves across all EVs, breaking down the features of a typical profile and where variation is typically seen. Power distribution results showed that over 50% of charge time is spent below 50kW and only 12.1% is spent above 200kW. SOC and range performance yielded different top performing EVs when exploring goals of performance from SOC and range gained after 10-min (EV2) and 20-min (EV8), and time-to-achieve 80% SOC (EV8) and 200 miles of range (EV1). Current draw from 400-volt EVs had a higher thermal impact to cable/connector temperatures when compared to 800-volt EVs, due to a higher current requirement to achieve similar power levels. There was high variance in C rating, a useful metric when comparing the relationship between peak/average charge session power and relative battery pack size, across EVs under test. Ramp rates during initial power transfer were examined, fastest and slowest speeds ranging from 192.5kW/second to 2.6kW/second respectively. A similar analysis of ramp rates was also conducted for OCPP curtailment testing, where EVs underwent a 2-minute 65A curtailment request before returning to full-power charge. Under off-nominal conditions, most EVs experienced variation from the nominal condition profiles. EVs that underwent the full set of NGP defined testing conditions were compared, analysis of which was categorized by 800-volt and 400-volt EVs. It should be noted that the 800-volt EVs had significantly higher peak power ratings than the 400-volt EVs, and thus were more prone to variance. Initial state of charge, battery temperature, and vehicle condition had a considerable impact on peak power levels and charge time for the 800-volt vehicles under test. EVSE limited tests lowered achievable power down to 200kW, greatly impacted 800-volt charging power, and had little to no effect on 400-volt charging power. Adapter testing was performed on a single 400-volt EV, where power and current limitations were found but overall charge time was not significantly impacted. Adapter and boost converter testing was performed on a single 800-volt EV, where both charge power and charge time were greatly impacted. Charge profiles are unique, and comparing such requires analysis that examines starting conditions, vehicle and battery topologies,

Charging↗

Demonstration of a Novel Phase-Space Painting Method in a Coupled Lattice to Mitigate Space Charge in High-Intensity Hadron Beams

Multiturn charge-exchange injection is the primary method of creating high-intensity hadron beams in circular accelerators, and phase space painting during injection enables tailoring of the accumulated phase space distribution. A technique we call eigenpainting allows injection of particles into a single mode of a coupled ring, providing full four-dimensional control of the phase space distribution. Under ideal conditions, uniform eigenpainting generates a linear-force equilibrium distribution in the transverse plane, with zero volume in four-dimensional transverse phase space, even including space charge. Here, we have implemented eigenpainting for the first time in the spallation neutron source accumulator ring. Injecting 8.8 μ⁢C of an 800 MeV beam, we obtain a final ratio of intrinsic transverse emittances of ≈2.4. We analyze the effect of space charge on the final distribution through comparison of the reconstructed phase space to particle-in-cell simulations.

Evans, Nicholas J. [Oak Ridge National Laboratory ↗

Charge-Density-Specific Response of Grafted Polyelectrolytes to Electric Fields: Bending or Tilting?

The response of polyelectrolytes (PEs) to applied electric fields drive applications in energetics, diagnostics, materials development, and many more. Here we employ all-atom molecular dynamics (MD) simulations to probe the response of grafted PE brushes to axial electric fields. For PEs with large charge densities, the electric field triggers a left-right asymmetric distribution of counterions around the PE backbone: consequently, depending on the location (left or right), there is an unequal screening and an unequal force on the PE functional groups causing a bending-driven brush height reduction. However, for the weakly charged PEs, the electric field causes a uniform distribution of the counterions across the brush enforcing a uniform (without left-right asymmetry) partially unscreened PE brush: therefore, all the brush segments experience similar force causing a brush tilting-driven brush height reduction. As a result, such bending versus tilting responses is commensurate with the electric-field-driven increase (decrease) in the flexibility of strongly (weakly) charged PEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations: Preprint

This paper presents an analysis of voltage control strategies for heavy duty electric vehicle (EV) charging stations. The performance of three voltage control approaches including power factor control, preset volt-var curve control, and customized volt-var curve control, have been investigated and evaluated for three different sizes of charging stations, including single-port small charging station, three-port middle size charging station, and 6-port travel center. The charging stations have been placed on various locations of four different types of distribution systems, to obtain a comprehensive performance analysis of the three voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics have been designed to quantify the performance and contribute to the comprehensive analysis summary.

47 OTHER INSTRUMENTATION↗

Water-Assisted Proton Transport in Confined Nanochannels

Hydrated excess protons under hydrophobic confinement are a critical component of charge transport behavior and reactivity in nanoporous materials and biomolecular systems. In this study, excess proton confinement effects are computationally investigated for sub-2 nm hydrophobic nanopores by varying the diameters (d = 0.81, 0.95, 1.09, 1.22, 1.36, 1.63, and 1.90 nm), lengths (l ~3 and ~5 nm), curvature, and chirality of cylindrical carbon nanotube (CNT) nanopores. CNTs with a combination of different diameter segments are also explored. The spatial distribution of water molecules under confinement is diameter-dependent; however, proton solvation and transport are consistently found to occur in the water layer adjacent to the pore wall, showing an “amphiphilic” character of the hydrated excess proton hydronium-like structure. The proton transport free energy barrier also decreases significantly as the nanopore diameter increases and proton transport becomes almost barrierless in the d > 1 nm nanopores. Among the nanopores studied, the Zundel cation (H 5 O 2 + ) is populated only in the d = 0.95 nm CNT (7,7) nanopore. The presence of the hydrated excess proton and K + inside the CNT (7,7) nanopore induces a water density increase by 40 and 20%, respectively. The K + transport through CNT nanopores is also consistently higher in the free energy barrier than proton transport. Interestingly, the evolution of excess protonic charge defect distribution reveals a “frozen” single water wire configuration in the d = 0.81 nm CNT (6,6) nanopore (or segment), through which hydrated excess protons can only shuttle via the Grotthuss mechanism. Vehicular diffusion becomes relevant to proton transport in the “flat” free energy regions and in the wider nanopores, where protons do not primarily shuttle in the axial direction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multimodal spectroscopy of order parameter distributions

We present a multimodal spectroscopic paradigm that enables independent measurement of charge and spin degrees of freedom (DOF) in strongly correlated materials. This spin-based technique probes symmetry-specific Hamiltonian parameters by analyzing how the time delay between applied pulses (τ) affects the response. We demonstrate ways in which charge DOF that couple through the quadrupolar interaction (inversion symmetric) can be independently measured even in the presence of large magnetic noise (inversion asymmetric). The method quantifies both the strength of the interactions and their distribution (noise). We provide protocols to directly and independently measure the distribution of interaction strengths, even when the average value of the interaction is zero. By independently measuring distributions of different forms of disorder, this methodology can elucidate which microscopic symmetry drives a phase transition. Here, we discuss potential applications to study complex phase transitions in strongly interacting quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control and Optimization of Energy Storage System in Power Distribution System

The widespread adoption of electric vehicles (EVs) and transportation electrification is encumbered by two chief barriers: i) the limited driving range of EVs in the market today and ii) inadequate fast-charging infrastructure for long-distance trips. Extreme fast charging (XFC) technology can recharge EVs in less than 10 minutes for 200 miles range. Firstly, a novel robust optimization-based mixed integer linear programming model is proposed to size a battery energy storage system (BESS) and PV system in an XFCS. In this part, it is assumed that the sizing and location of the XFCS are known. Secondly, the aforesaid assumption is relaxed, and a strategic multi-period coordinated planning model is proposed to optimally site and size BESS-assisted charging stations in a highway transportation network and PV systems in a power distribution network by considering the coupling between both networks. Optimal operation and control of BESS-assisted EV charging stations are vital to alleviate the adverse impact of extreme fast charging of EVs on the host power network. A joint solution is proposed to mitigate the steady state and transient impact of extremefast charging of EVs and ensure grid-friendly integration of XFCSs with the host grid. Lastly, to make the operation of the XFCS cost-effective, a multi-layered energy management framework is proposed for the XFCS by considering forecast uncertainties, monthly demand charges reduction, and BESS degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Electric Vehicle Charging and Discharging Strategies Under DER Compensation Programs: Preprint

The adoption of electric vehicles (EVs) is becoming increasingly popular because of environmental concerns, the greater availability of models, and increased cost-competitiveness with gas vehicles. Because EVs have both charging and discharging capabilities, they provide great potential to help electric utilities with grid operation. When the grid demand is high, EVs can discharge to the grid to reduce the peak load, and vice versa; therefore, electric utilities have designed different policies to encourage EV charging station operators to charge or discharge at certain time periods. The New York State Public Service Commission established the Value of Distributed Energy Resources (VDER), or the Value Stack, to compensate for energy created by distributed energy resources, including EVs. This paper presents an optimization-based approach to identify the "golden hours" and "golden spots," i.e., the effective time periods and geographic locations for EV charging station operators to charge or discharge under the VDER program that can provide them the highest benefit. The proposed methodology can be applied to other compensation mechanisms and distribution systems as well. By working with industry partner NineDot Energy, realistic charging station information is used in this study, and the proposed approach is tested on a distribution feeder. The results from this study can help electric utilities and EV charging station operators determine the ideal charging/discharging time and the ideal locations for the charging station(s) in their distribution systems to achieve maximized benefit.

electric vehicle↗

Revenue-Maximizing Shared Parking and Electric Vehicle Charging Management in Multi-Unit Dwellings

In urban areas, searching for parking and electric vehicle (EV) charging can result in cruising, congestion, and environmental externalities. Recognizing the business opportunity of offering private parking and charging infrastructure access within multi-unit dwellings (MUDs) during daytime, we model a shared parking and EV charging management system. We maximize the revenue of MUD charging hubs in mixed land use, catering to public demand. Our approach accounts for the objectives of the two stakeholders involved: a demand model is fitted on the choices of EV charging users, and the supply model optimizes the allocation of parking and charging requests in an MUD parking lot. A binary integer linear programming model for the allocation of parking and charging spaces with a rolling horizon is integrated with matching rules that handle both parking and charging requests. In our numerical experiments in a neighborhood of Chicago, Illinois, we estimate the performance of the MUD parking and charging system with metrics that include revenue, number of matchings, and utilization rates. At any given time, MUDs with lower prices attract more charging requests, particularly those of longer duration, resulting in higher revenue and greater charging utilization. Dynamic pricing facilitates a more equitable distribution of requests; as MUD parking lots reach capacity and their fees increase, other MUDs become more competitive, attracting additional requests. Comparing our method against first-come-first-served and optimal-solution benchmarks, we demonstrate our model’s effectiveness in dynamically managing mixed parking and charging demand in MUD charging hubs.

electric vehicle, multi-unit dwelling, charging in↗

Considerations for Developing a Regulatory Roadmap for Distributed Energy Resource (DER) Integration in Colombia

The USAID-NREL Partnership in Colombia, in conjunction with SURE and USEA, selected four action plan teams from the Young Professionals Leadership Program to receive tailored NREL technical assistance to support action plan implementation. The four plans selected represent various aspects associated with planning for the efficient integration of DERs, including electric mobility, residential and commercial energy applications, distributed generation modeling, and regulatory considerations. In response to national grid modernization, decentralization, digitalization, and electrification trends, CREG is looking to update Colombia's electric distribution code, with an emphasis on the integration of electric vehicles and charging stations, but also energy storage systems, non-conventional sources of renewable energy, and other distributed energy resources (DERs). CREG aims to establish the general steps that must be carried out to update the distribution code for the integration of DERs, with a view to the design and development of new markets. The objective of the TA provided to CREG was to support them in identifying and outlining the general processes and approaches to consider when updating Colombia's distribution code for the integration of electric vehicles, distributed renewable energy systems, and energy storage systems, with a view to the design and development of new markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

V28 Test Report

The V28 containment vessel was procured by the US Army Recovered Chemical Material Directorate (RCMD) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the fourth EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the Code Case, is nine (9) pounds TNT- equivalent for up to 637 detonations. This report documents the results of explosive tests that were done on the vessel at Sandia National Laboratories in Albuquerque New Mexico to qualify the vessel for explosive use. The primary qualification test consisted of six, 1.5 pounds charges of Composition C-4 (equivalent to 11.25 pounds TNT) distributed around the vessel in accordance with the User Design Specification. This test was repeated due to a lack of proper clamp settings. Two additional tests using less explosive were performed, one identical in configuration to a test performed in the V27 qualification series as a baseline for comparison, and one where the separation distance of the charges was increased to extend the V27 analysis of distributed load effects on the P2 vessel. All vessel acceptance criteria were met.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Pricing Strategy of Electric Vehicle Aggregators Based on Locational Marginal Price to Minimize Photovoltaic (PV) Curtailment

The global climate crisis demands urgent action to mitigate global warming. Using renewable energy sources, such as solar and wind power, for electricity generation is crucial. This shift from centralized to distributed power systems, however, brings challenges, including voltage fluctuations and renewable energy curtailment. The rapid growth of the electric vehicle (EV) industry adds complexity, increasing overall electricity demand and straining the power supply during peak charging times. This paper proposes a scheduling strategy for EV aggregators to reduce renewable energy curtailment and stabilize grid operation by strategically scheduling EV charging. Using Multi -Agent Transport Simulation (MATSim), a traffic simulation tool, EV driving data in Denver, Colorado, USA, were modeled. The EV aggregator adjusts charging fees based on locational marginal prices, encouraging EVs to charge at different stations according to pricing. Simulations on an IEEE 33-bus system with distributed energy resources and EV charging stations validate the proposed algorithm, demonstrating its effectiveness in reducing curtailment by 12.55% and stabilizing grid operation.

33 ADVANCED PROPULSION SYSTEMS↗

Design of non-fluorinated proton exchange membranes from Poly(Terphenyl fluorenyl isatin) with fluorene-linked sulfonate groups and microblock structures

Proton exchange membranes (PEMs) are essential components in energy storage and conversion devices, such as fuel cells and electrolyzers. Here, in this study, we developed a series of non-fluorinated PEMs from poly(terphenyl fluorenyl isatin) with fluorene-pendent disulfonate groups. These polymers feature a microblock structure composed of hydrophobic blocks, hydrophilic blocks, and alternating blocks, arising from the differences in reactivity, concentration, and solubility between the hydrophobic p-terphenyl and hydrophilic disulfonated fluorene monomers. As a result, the sulfonic acid groups are unevenly distributed along the polymer chains, forming densely charged regions (IEC = 3.52 meq/g) with large ion clusters and lightly charged regions (IEC = 2.16 meq/g) with small ion clusters. This microstructure, combined with the degree of sulfonation, significantly influences the overall properties of the membranes, including robust mechanical strength (47.1–63.2 MPa), high thermal stability (up to 270 °C), low swelling ratio (18–25% at 80 °C), and high proton conductivity (136–169 mS/cm in deionized water at 80 °C). The PFLSH60 membrane demonstrated comparable fuel cell performance to Nafion 212. Its hydrogen crossover current density was more than two times lower (0.86 mA/cm 2 for PFLSH60 compared to 1.83 mA/cm 2 for Nafion 212) under testing conditions of 80 °C and 100% RH. This significantly reduced crossover improves fuel utilization in fuel cell stacks. This work offers valuable insights into the design of robust, high-performance PEMs by systematically analyzing the relationships between membrane structure, properties, and performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stable Solid Electrolyte Interphase Layer Formed by Electrochemical Pretreatment of Gel Polymer Coating on Li Metal Anode for Lithium–Oxygen Batteries

Lithium (Li)-oxygen (O2) batteries (LOBs) exhibit the highest theoretical specific energy density among candidates of the next-generation energy storage systems, but the instability of Li metal anode (LMA), air electrode, and electrolyte largely limit the practical energy density of these batteries. Herein, we report an effective method to protect LMA against side reactions between LMA and crossover contaminants such as highly reactive oxygen moieties. A solid electrolyte interphase (SEI) layer rich in inorganic components was formed on a LMA coated with polyethylene oxide thin-film through an in-situ electrochemical pre-charging step under oxygen atmosphere. This uniformly distributed stiff SEI layer interacted with flexible polymer matrix and formed a submicron-sized gel-like polymer layer. This polymer supported SEI layer leads to much longer cycle life (130 vs. 65 cycles) as compared to those of pristine cell under the same testing conditions (1.0 mAh cm-2 at 0.2 mA cm-2 in the voltage range of 2 to 5 V without any catalysts). It is also very effective during low voltage (2 to 4.5 V) cycling with a redox mediator (0.1 and 0.15M (2,2,6,6-tetramethylpiperidin-1-yl) oxidanyl). Therefore, this approach can be used to stabilize LMA/electrolytes interphase and improve the cycle life of rechargeable LOBs.

lithium-oxygen batteries, lithium metal anodes, ar↗

Approaching disorder-tolerant semiconducting polymers

Doping has been widely used to control the charge carrier concentration in organic semiconductors. However, in conjugated polymers, n-doping is often limited by the tradeoff between doping efficiency and charge carrier mobilities, since dopants often randomly distribute within polymers, leading to significant structural and energetic disorder. Here, we screen a large number of polymer building block combinations and explore the possibility of designing n-type conjugated polymers with good tolerance to dopant-induced disorder. We show that a carefully designed conjugated polymer with a single dominant planar backbone conformation, high torsional barrier at each dihedral angle, and zigzag backbone curvature is highly dopable and can tolerate dopant-induced disorder. With these features, the designed diketopyrrolopyrrole (DPP)-based polymer can be efficiently n-doped and exhibit high n-type electrical conductivities over 120 S cm -1 , much higher than the reference polymers with similar chemical structures. This work provides a polymer design concept for highly dopable and highly conductive polymeric semiconductors.

36 MATERIALS SCIENCE↗