Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Winnett Public School District Energy Improvements

The Winnett Public School District Energy Improvement Project was funded through the U.S. Department of Energy's Renew America's Schools Program, which supports rural and underserved school districts in upgrading aging facilities and improving energy performance. The completed improvements directly advance the program's objectives by replacing the District's outdated coal-fired heating system with a modern, high-efficiency propane boiler system, while also enhancing ventilation systems and building envelope performance throughout the school. These upgrades provide a more reliable heating system and improved indoor air quality, creating a healthier and more comfortable environment for students and staff. In addition, replacing the aging boiler system has reduced long-term maintenance demands for one of Montana's most rural school districts, allowing the District to redirect limited financial resources toward other critical needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent Systems Technologies and Utilization of Earth Observation Data

The addition of raw data and derived geophysical parameters from several Earth observing satellites over the last decade to the data held by NASA data centers has created a data rich environment for the Earth science research and applications communities. The data products are being distributed to a large and diverse community of users. Due to advances in computational hardware, networks and communications, information management and software technologies, significant progress has been made in the last decade in archiving and providing data to users. However, to realize the full potential of the growing data archives, further progress is necessary in the transformation of data into information, and information into knowledge that can be used in particular applications. Sponsored by NASA s Intelligent Systems Project within the Computing, Information and Communication Technology (CICT) Program, a conceptual architecture study has been conducted to examine ideas to improve data utilization through the addition of intelligence into the archives in the context of an overall knowledge building system (KBS). Potential Intelligent Archive concepts include: 1) Mining archived data holdings to improve metadata to facilitate data access and usability; 2) Building intelligence about transformations on data, information, knowledge, and accompanying services; 3) Recognizing the value of results, indexing and formatting them for easy access; 4) Interacting as a cooperative node in a web of distributed systems to perform knowledge building; and 5) Being aware of other nodes in the KBS, participating in open systems interfaces and protocols for virtualization, and achieving collaborative interoperability.

Ramapriyan, H. K.↗

Design of a Mechanical NaK Pump for Fission Space Power

Alkali liquid metal cooled fission reactor concepts are under development for spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid, which has specific pumping requirements. Traditionally, electromagnetic linear induction pumps have been used to provide the required flow and pressure head conditions for NaK systems but they can be limited in performance, efficiency, and number of available vendors. The objective of the project was to develop a mechanical NaK centrifugal pump that takes advantages of technology advances not available in previous liquid metal mechanical pump designs. This paper details the design, build, and performance test of a mechanical NaK pump developed at NASA Marshall Space Flight Center. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

Mireles, Omar R.↗

Ensemble Manufacturing Techniques for Steam Turbine Components Across Length Scales

Faster design to manufacturing requirements were sought for steam turbine components to meet the changing demands of today’s power grid of improved efficiency through operating temperature increases and enhanced operational flexibility from baseload to cyclic operations. Advances in multiple advanced manufacturing (AM) process enabled redesign of turbine components for extreme environments with the potential to reduce cost. AM is of particular interest to improve component functionality, higher temperature capability, and superior durability in large scale steam turbine applications. AM methods have an immense potential to open-up the design space by working directly with the 3D model to produce near-net shapes, enable fast design-manufacturing iterations, thereby significantly reducing product cost and lead-time up to 25 % from current baseline. However, these benefits cannot be fully realized due to the potential for unknown AM processing defects and their resultant effect upon component performance in service. Siemens is partnering with Oak Ridge National Laboratory (ORNL), Electric Power Research Institute (EPRI), and Connecticut Center for Advanced Technology (CCAT) to advance the knowledge of complex process-material interactions for desired microstructures and properties that are closely interlinked to component geometries across different length scales. The proposed program utilized an ensemble of multidisciplinary technologies to accelerate the development of materials, high-throughput experiments for their qualification, and design flexibility/topology optimization for repair/redesign of components to address critical failure mechanisms for improved performance and increased reliability of existing power plant components. The proposed activities, if successfully demonstrated for identified components, will enable paradigm shift in customized manufacturing and accelerated qualification/certification towards increased steam turbine component durability, increased turbine efficiency, and reduced CO 2 emissions in load-following environments compared to today’s technology. Technology maturation is built into the project as successful research will include customized process-component down-selection enabling AM methodologies to be incorporated directly into the existing supply chain. The specific activities of the proposed effort are: 1. Topology optimization of down-selected steam turbine parts that are amenable to additive and hybrid manufacturing for cost/performance improvement. 2. Process-structure-property relationships for five AM processes for steam turbine materials of interest to compare with conventional materials. 3. Perform part/assembly build process using advanced additive/hybrid machine tools followed by quality inspection of the built components for insight into qualification for production scale-up. Steam turbine rig testing of printed components under targeted, well monitored and characterized environmental conditions of for performance comparison of baseline and redesigned components.

36 MATERIALS SCIENCE↗

Advanced Envelope Research for Factory Built Housing, Phase 3. Whole-House Prototyping

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective envelope designs that can be effectively integrated into the plant production process while meeting the thermal requirements of the 2012 IECC standards. This work is part of a multiphase effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three methods for building high performance walls. Phase 2 focused on developing viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped narrow the research focus to perfecting a stud wall design with exterior continuous insulation (CI). This report describes Phase 3, which was completed in two stages and continued the design development effort, exploring and evaluating a range or methods for applying CI to factory built homes. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing. During this phase, a home was built with CI, evaluated, and placed in service. The experience of building a mock up wall section with CI and then constructing on line a prototype home resolved important concerns about how to integrate the material into the production process. First steps were taken toward finding least expensive approaches for incorporating CI in standard factory building practices and a preliminary assessment suggested that even at this early stage the technology is attractive when viewed from a life cycle cost perspective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benchmarking Demand Flexibility in Commercial Buildings and Flattening the Duck – Addressing Baseline and Commissioning Challenges

With the transition from our traditional electric grid to a cleaner grid with renewable power generation, there is a need to enable building loads to be flexible. Load shedding and shifting will be essential for flattening the “Duck” for decarbonization. This paper explored the trend in the timing of DR events as a reflection of the grid’s needs using recent four years of event data from 203 retail stores in 11 states. The events are becoming significantly shorter with 2-hour duration being the most popular; shifting to late afternoon and early evening is another trend beyond California. Benchmarking will be essential for accounting DF as a reliable grid resource. This paper addresses a challenging aspect of benchmarking – inaccuracies in counterfactual baseline methods can introduce significant DF metrics variations in addition to weather and building characteristics related factors. The conventional “10/10” with adjustment baseline method has inherent limitation by design for load shifting applications. Therefore, it is imperative to identify alternative methods. This study compared three hourly regression baseline methods with “10/10” methods using two groups of commercial buildings that participated in DR programs: (1) 121 big-box retail stores, and (2) 11 office buildings in CA. The 14-day hourly outdoor temperature regression method was found to produce least error in the tested datasets and is promising for load shifting. The paper also pointed out that commissioning issues can also be a significant barrier for achieving consistent DF performance, which building managers and utilities should be aware of.

Liu, Jingjing↗

Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States. LBNL performed its field-metering study from mid-April to late October 2014. The study, which monitored 19 sites in the Northeastern United States (4 in upstate New York and 15 near Philadelphia), collected real-time data on PAC energy consumption along with information regarding housing characteristics, consumer behavior, and environmental conditions that were expected to affect PAC performance. Given the limited number of test sites, this study was not intended to be statistically representative of PAC users in the United States but rather to understand the system response to the cooling demand and to some extent, the operating hours of the studied units. Specifically, the primary objectives of the field-metering study were to (1) expand knowledge of the installation, energy consumption profiles, consumer patterns of use, and environmental parameters related to PAC use; (2) develop distributions of hours of PAC operation for three operating modes: standby, 1 fan-only, and cooling; and (3) describe how individual consumers’ selection of PAC capacity, the area of the space to be cooled, the temperature set point, and environmental conditions affect energy use. Beginning to understand the energy consumption of PACs operating in American homes and commercial settings will help develop a more accurate energy use profile that characterizes relevant variables. This report on LBNL’s field-metering study of PAC energy use describes: a general definition of a PAC and how it operates (section 2); current practices and sources of data for estimating PAC energy use (section 3); the process LBNL used to select field-metering sites, along with characteristics of the sites and the PACs studied (section 4); data collection methods and instrumentation (section 5); analysis methods (section 6); results and discussion (section 7); and conclusions (section 8).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pre-Launch Performance Trending of Joint Polar Satellite System (JPSS) Advanced Technology Microwave Sounder (ATMS)

The Advanced Technology Microwave Sounder (ATMS) microwave radiometer instrument is utilized on-board NOAA’s Joint Polar Satellite System (JPSS) fleet of spacecraft to perform temperature and water vapor soundings of Earth’s atmosphere. Consisting of 22 channels over a frequency range from 22 to 183 GHz, ATMS provides high-impact observations for numerical weather prediction (NWP) models. A general description of the ATMS instrument is discussed in [1]. There are five ATMS flight units in the polar-orbiting JPSS program; three are currently on-orbit and two are pending launch. The first ATMS was flown on the Suomi National Polar-orbiting Partnership (SNPP) satellite, launched in 2011. The second ATMS was launched on the NOAA-20 (previously JPSS-1) satellite in 2017. The third ATMS was launched on the NOAA-21 (previously JPSS-2) satellite in 2022. The SNPP and NOAA-20 ATMS units are operational. The NOAA-21 ATMS unit is completing on-orbit commissioning and checkout, having achieved provisional maturity status in December 2022 with validated maturity expected in May 2023 [2]. The fourth and fifth ATMS units are planned for the JPSS-3 (launch ~2028) and JPSS-4 (launch ~2032) satellites [3]. This paper will focus on trending performance characteristics of each JPSS ATMS build from the pre-launch activities. Pre-launch trending of some parameters have been previously published up to the JPSS-3 mission [4][5]. This paper differs from and expands the scope of the prior work as it will include all five of the JPSS ATMS builds. The entire suite of JPSS ATMS units have completed their pre-ship instrument-level I&T and verification activities. These activities include a radiometric performance characterization of each instrument. In addition to comparing the performance across builds, the performance will also be compared to requirements and specifications where applicable. The on-orbit performance of the launched units will be excluded from the scope of this paper in order to focus on evaluations that are common across all builds. The post-launch performance of SNPP ATMS is detailed in [1][6][7][8]. The post-launch performance of NOAA-20 ATMS is detailed in [6][8][9]. The pre-launch characterization of the ATMS occurs at both subassembly-level and instrument-level testing. The antenna subsystem is tested at Northrop Grumman’s Compact Antenna Test Range (CATR) in Azusa, CA [9]. This testing characterizes the antenna pattern and the pointing performance of the scan drive mechanism and antenna subsystem. Trended parameters from this evaluation will include beam pointing accuracy, beamwidth, and beam efficiency. These parameters are captured in each instrument’s Calibration Data Book [10]. Instrument-level radiometric performance evaluation is primarily done during thermal vacuum (TVAC) calibration testing at Northrop Grumman’s Azusa, CA facility [9]. A general description of the calibration activities is presented in [1][9]. The testing involves inferring a scene target brightness temperature (TB) and comparing it to the actual scene TB while the instrument is at flight-like temperature and pressure environmental conditions. Trended parameters from this activity will include Noise Equivalent Delta Temperature (NEDT), nonlinearity, radiometric accuracy, gain stability, striping, and inter-channel noise correlation. The trending evaluation will allow for a direct comparison of the ATMS performance across builds. The paper will highlight observed performance improvements.

Edward J Kim↗

Energy Management Information Systems Technical Resources Report

Guide supports federal facility staff in understanding, designing, procuring, and implementing Energy Management Information Systems (EMIS) as a valuable component of their portfolio-level energy and water planning and management strategies. As a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance, EMIS tools present significant opportunities for federal sector energy savings and improved operational performance. EMIS are at the forefront of transforming energy management best practices by providing building owners and operators with well-organized building performance and energy consumption data, enabling a host of analytic capabilities. These capabilities include portfolio-wide energy benchmarking, data visualization, and key performance indicator tracking; automated fault detection and diagnostics (AFDD); artificial intelligence for predictive analytics and control; automated measurement and verification of energy conservation measures; and supervisory control enabling automated system optimization and demand management.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent Systems Technologies to Assist in Utilization of Earth Observation Data

With the launch of several Earth observing satellites over the last decade, we are now in a data rich environment. From NASA's Earth Observing System (EOS) satellites alone, we are accumulating more than 3 TB per day of raw data and derived geophysical parameters. The data products are being distributed to a large user community comprising scientific researchers, educators and operational government agencies. Notable progress has been made in the last decade in facilitating access to data. However, to realize the full potential of the growing archives of valuable scientific data, further progress is necessary in the transformation of data into information, and information into knowledge that can be used in particular applications. Sponsored by NASA s Intelligent Systems Project within the Computing, Information and Communication Technology (CICT) Program, a conceptual architecture study has been conducted to examine ideas to improve data utilization through the addition of intelligence into the archives in the context of an overall knowledge building system. Potential Intelligent Archive concepts include: 1) Mining archived data holdings using Intelligent Data Understanding algorithms to improve metadata to facilitate data access and usability; 2) Building intelligence about transformations on data, information, knowledge, and accompanying services involved in a scientific enterprise; 3) Recognizing the value of results, indexing and formatting them for easy access, and delivering them to concerned individuals; 4) Interacting as a cooperative node in a web of distributed systems to perform knowledge building (i.e., the transformations from data to information to knowledge) instead of just data pipelining; and 5) Being aware of other nodes in the knowledge building system, participating in open systems interfaces and protocols for virtualization, and collaborative interoperability. This paper presents some of these concepts and identifies issues to be addressed by research in future intelligent systems technology.

Ramapriyan, Hampapuram K.↗

Split-pane electrochromic window control based on an embedded photometric device with real-time daylighting computing

Well-designed electrochromic (EC) glazing control can improve the energy performance of buildings and visual comfort of occupants in highly glazed buildings. Here in this paper, we designed and demonstrated a compact integrated EC glazing automation system to control tint states of a split-pane EC window according to variations of sky conditions. The control is based on monitoring the luminance distribution of the sky and real-time lighting computation for a building interior, using an embedded photometric device (EPD). It optimizes tint states of EC glazing to offer sufficient daylight provision and temper discomfort glare for occupants, which potentially mitigates excessive solar heat gain. ’In-situ’ experiments were conducted in a full-scale testbed to demonstrate the daylighting performance under various sky conditions. Finally, experimental results showed 83% of the working time for work-plane illuminance (WPI) and 95% of the time for daylight glare probability (DGP) were constrained in comfort range (WPIϵ[500, 2000] lux, DGP ≤ 0.35) by the automated EC glazing (controlled by EPD) under clear skies; 68% of the time for WPI and 94% of the time for DGP in confined range under clear skies with thin clouds; 62% of the time for WPI and 85% of the time for DGP in confined range under partly cloudy skies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Insulation Strategies of Cross-Laminated Timber Assemblies on Energy Use, Peak Demand, and Carbon Emissions

Cross-Laminated Timber (CLT) panels have many structural benefits but do not have much thermal resistance. We have developed a solution to insulate CLT structures that uses high-performance insulation panels that provide R-values up to R40/inch. The CLT panels are made of layers of wood laminates (three, five, seven or more). The solution replaces some of the wood laminates in the CLT production with the insulation panels in a staggered fashion so that the wood laminates maintain contact throughout the panel, ensuring the CLT panel’s structural integrity. The insulated CLT panels have factory-installed water-resistive barriers reducing the installation time by eliminating installing insulation and water-resistive barriers on site. Per simulations, the CLT/insulation panel achieved code-required insulation levels with commonly available insulation materials. The significance of the thermal mass of CLT/insulation hybrid building envelopes was quantified by comparing the whole building energy performance and peak demand of traditional low mass and CLT wall assemblies resulting in up to 7% reduction in peak demand for cooling in Knoxville, TN, in a multifamily building. Buildings contribute over 40 percent of carbon emissions. The proposed CLT/insulation hybrid building envelope addresses both operational and embodied carbon by having high thermal resistances due to the embedded insulation sections and eliminating the use of high embodied carbon materials such as steel and concrete. The carbon benefit is estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Boundary-Aware Adversarial Learning Domain Adaption and Active Learning for Cross-Sensor Building Extraction

The use of convolutional neural networks (CNNs) for building extraction from remote sensing images has been widely studied and many public datasets have been made available for accelerating development of these CNN models. Yet adapting pretrained models at scale in real-world scenarios remains a challenging task. The main barrier is that certain new labels are still needed to compensate for domain shifting between the labeled data and new images that potentially cover new geographic locations or that are from a different sensor. In this article, we propose to add informatively labeled samples from a new image pool under the paradigm of active learning. To select the most useful samples based on model uncertainty, we first tackle the problem of uncalibrated uncertainty estimation due to distribution shifting by adapting feature extractors with boundary-based adversarial learning. Calibrated uncertainty is used as the query criterion in the active learning process, where the most uncertain samples are selected for annotation and included for model retraining. The proposed workflow was tested with three data pairs in which each workflow represents a scenario often encountered in real-world applications, including adapting pretrained models to new images collected with different sensors or to new geographic areas where appearances and types of buildings are very different. Compared to several baselines, including random sampling, temperature scaling (a well-known uncertainty calibration technique), different query strategies, and active domain adaptation methods, the proposed workflow shows that strategically querying a smaller set of samples for labeling achieves comparable or better building extraction performance. The proposed method reduces the number of labeled samples required to achieve sufficient model accuracy, thus significantly reducing hundreds of person-hours for labeled data creation. In addition, we include a few considerations when deploying this workflow in a GPU cluster that can be easily adapted to achieve operational building extraction model retraining.

97 MATHEMATICS AND COMPUTING↗

Modeling the Risk of Radiation-Induced Acute Esophagitis for Combined Washington University and RTOG Trial 93-11 Lung Cancer Patients

Purpose: To construct a maximally predictive model of the risk of severe acute esophagitis (AE) for patients who receive definitive radiation therapy (RT) for non-small-cell lung cancer. Methods and Materials: The dataset includes Washington University and RTOG 93-11 clinical trial data (events/patients: 120/374, WUSTL = 101/237, RTOG9311 = 19/137). Statistical model building was performed based on dosimetric and clinical parameters (patient age, sex, weight loss, pretreatment chemotherapy, concurrent chemotherapy, fraction size). A wide range of dose-volume parameters were extracted from dearchived treatment plans, including Dx, Vx, MOHx (mean of hottest x% volume), MOCx (mean of coldest x% volume), and gEUD (generalized equivalent uniform dose) values. Results: The most significant single parameters for predicting acute esophagitis (RTOG Grade 2 or greater) were MOH85, mean esophagus dose (MED), and V30. A superior-inferior weighted dose-center position was derived but not found to be significant. Fraction size was found to be significant on univariate logistic analysis (Spearman R = 0.421, p < 0.00001) but not multivariate logistic modeling. Cross-validation model building was used to determine that an optimal model size needed only two parameters (MOH85 and concurrent chemotherapy, robustly selected on bootstrap model-rebuilding). Mean esophagus dose (MED) is preferred instead of MOH85, as it gives nearly the same statistical performance and is easier to compute. AE risk is given as a logistic function of (0.0688 Asterisk-Operator MED+1.50 Asterisk-Operator ConChemo-3.13), where MED is in Gy and ConChemo is either 1 (yes) if concurrent chemotherapy was given, or 0 (no). This model correlates to the observed risk of AE with a Spearman coefficient of 0.629 (p < 0.000001). Conclusions: Multivariate statistical model building with cross-validation suggests that a two-variable logistic model based on mean dose and the use of concurrent chemotherapy robustly predicts acute esophagitis risk in combined-data WUSTL and RTOG 93-11 trial datasets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technology Solutions Case Study: Predicting Envelope Leakage in Attached Dwellings

The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this “solo” test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. In an attempt to create a simplified tool for predicting leakage to the outside, Building America team Consortium for Advanced Residential Buildings (CARB) performed a preliminary statistical analysis on blower door test results from 112 attached dwelling units in four apartment complexes. Although the subject data set is limited in size and variety, the preliminary analyses suggest significant predictors are present and support the development of a predictive model. Further data collection is underway to create a more robust prediction tool for use across different construction types, climate zones, and unit configurations.

algorithm↗