Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Developing Flexible, Networked Lighting Control Systems That Reliably Save Energy in California Buildings

An important strategy to meet California's ambitious energy efficiency goals is to use innovative wireless communications, embedded sensors, data analytics and controls to significantly reduce lighting energy use in commercial buildings. This project developed a suite of networked lighting solutions to further this goal. The technologies include a platform for low-cost sensing, distributed intelligence and communications, the “PermaMote,” which is a self-powered sensor and controller for lighting applications. The project team also developed a task ambient daylighting system that integrates sensors with data-driven daylighting control using an open communication interface, called the “Readings-At-Desk” (RAD) system. To address the problem of building occupants being confused about how to operate traditional lighting control systems, the research team created content that could be the basis for a user interface standard for lighting controls. Finally, to address the difficulty of ensuring that advanced lighting control systems actually deliver their promised energy savings, the project team developed a new method for evaluating and specifying lighting systems’ performance. The research team validated these technologies in the laboratory, showing significant lighting energy savings, up to 73% for the PermaMote sensor system from occupancy control and daylight dimming features, compared to the same light source (LED replacement lamps) operated via simple on/off scheduling. The project team also developed a proposed standard lighting data model and user interface elements, which were contributed to the ANSI Lighting Systems Committee (C137) for standardization. Existing data models are incomplete and inconsistent, whereas the lighting-specific data model developed here is clear and comprehensive, to serve as a starting point for creating common, universally agreed upon semantic definitions of key lighting parameters, to promote interoperability. For the task on verifiable performance of lighting systems, the project team developed a more effective metric for capturing the actual energy impact of a lighting system over time — the energy usage intensity (kWh/ft2/year). Three commercial lighting systems were tested in FLEXLAB® using this new metric, and the tests show a wide range in the accuracy of the self-reported energy-use metric, from 0.5% to 28% error compared to direct measurement of lighting energy using dedicated submeters. Overall, the project team estimates that these advanced technologies can reduce California office lighting energy use by 20% (above and beyond normal advanced lighting controls mandated by Title 24), resulting in about 1,600 GWh/year in savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TA-16-0303 Crystal Grow Lab Renovation

The LANL High Explosives (HE) Crystal Lab at TA-40 Building 12 is a unique, and nearly the sole, national resource for the growth and sample preparation of large HE single crystals and related materials. This work has outgrown is current facility and is in dire need of both additional space and modern lab technology. The goal of this project is to renovate the 1950’s era building TA-16-303 to accommodate these operations and successfully relocate them from TA-40-12. Phase 1 of this project, completed in May of 2018, was to de-energize the facility and perform cleanup / remediation activities. Phase 2, the actual renovation of the facility, is currently underway and scheduled to achieve Occupancy by September of 2020.

99 GENERAL AND MISCELLANEOUS↗

First-principles Modeling and Design of Solid-State Interfaces for the Protection and Use of Lithium Metal Anodes

Li-ion batteries are one of the most advanced energy storage technologies in use today. Li-ion batteries are used in a multitude of applications ranging from consumer electronics, medical devices, sensors and grid storage. However, improving the capacity and energy density delivered by current Li-ion technology requires advanced materials research into novel chemical systems. In this project we have focused particularly in the use of solid-state electrolytes with lithium metal electrodes. Research into all solid-state batteries (ASSB) with Li metal electrodes has significantly expanded in recent years, however most studies reported experimental findings, which left substantial room for theoretical and modeling work as a tool to understand and determine design principles allowing reliable and safe use of ASSBs with Li metal. Among the remaining obstacles preventing reliable use of ASSBs with a Li metal electrode, the stability of the interface between the solid electrolyte and Li metal, and the propagation/dendrite formation of Li metal and resulting mechanical degradation of the electrolyte are key phenomenon that are yet to be fully understood. In the current project we have addressed these two coupled phenomena using first principles calculations and mesoscale continuum modeling. We have obtained chemical and electrochemical stability windows for several solid electrolyte materials. Additionally, from mathematical and numerical modeling of Li protrusion and dendrite initiation during plating and stripping we have determined design criteria in terms of chemical, electrochemical, and mechanical properties and operating conditions for which stable deposition can occur. We also considered the effects of mixed electronic-ionic conduction in solid electrolytes, which has more recently been suggested as another important mechanism involved in ASSB failure. Throughout our work we have successfully addressed important questions necessary for the use of ASSB’s. We have determined guiding principles for materials properties and operating conditions necessary to operate ASSB’s. And have proposed novel solid electrolyte materials with predicted chemical stability an ionic conductivity. Although this represents significant progress in our understanding, open questions remain in order to fully develop reliable and safely operate ASSBs with Li metal. Future work, building on this project will require further experimental, theoretical and simulation efforts to address remaining questions.

25 ENERGY STORAGE↗

Document Management: A Focused Analysis on the Configuration Management Process at Y-12 National Security Complex

The configuration management process at Y-12 is a crucial process to ensure safe operations and compliance with Department of Energy (DOE) regulations and requirements. This process is evaluated utilizing systems-thinking methodology in order to understand the current operational flow, with the ultimate goal of building an easily understandable, representative model. This model offers insights on key areas of waste and provides a potential solution by modernizing rate limiting steps: a software implementation to update the traditional document management system and make it paperless. Stakeholders of the software implementation are identified in order to define characteristic requirements of an effective product and the anticipated benefit is evaluated. Ultimately, this project is an effort to increase the quality of life for all stakeholders, while improving the capacity, throughput, and effectiveness of a necessary process at Y-12.

42 ENGINEERING↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2021

Underlying each of the Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a Life-Cycle Cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample in order to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level financial data (Fujita, 2016). Major topics covered in this report include: Discount rate estimation methods and rationale; -Data sources used and data limitations; -Discount rate distributions for use in standards analysis; -Discount rate estimation methods and distributions specific to the small business subgroup analysis. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Historical Documentation of Buildings 0460 and 0463 at Technical Area 16 (Volume 1)

This report provides documentation as a standard mitigation measure to the adverse effects that occurred by the demolition of theses historic properties. To mitigate the adverse effects, LANL has followed Section 106 process contained in 36 CFR 800.6, resolution of adverse effects. In addition to these regulations and within this report, LANL has implemented the standards for documenting and reporting in accordance with the A Plan for the Management of the Cultural Heritage at Los Alamos National Laboratory, New Mexico (CRMP), LA-UR-19-21590, formerly LA-UR-15-27624. These standard reporting measures include archival-quality digital photographs of the building’s interior, exterior, outside landscape; updating LANL historic building survey forms including 11 in. x 17 in. copies (in a reduced scale) of key original and as-built drawings; identification and documentation of historically significant equipment and artifacts; a comprehensive list of LANL architectural drawings; construction-history maps of TA-16 including current Register Eligible and Ineligible Buildings; and a detailed use history of the building and technical division associated with its operation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2022

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: -Discount rate estimation methods and rationale -Data sources used and data limitations -Discount rate distributions for use in standards analysis -Discount rate estimation methods and distributions specific to the small business subgroup analysis A version of this analysis was most recently released in 2022. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2023

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process relying on the Capital Asset Pricing Model (CAPM) to estimate a business’ cost of equity, and by adding a risk adjustment factor to the risk-free rate associated with long-term U.S. Treasury bonds to estimate their cost of debt. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: • Discount rate estimation methods and rationale • Data sources used and data limitations • Discount rate distributions for use in standards analysis • Discount rate estimation methods and distributions specific to the small business subgroup analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Cost Electrochemical Compressor (ECC) Utilizing Green Refrigerants for HVAC Applications [Slides]

HVAC systems account for approximately 14 Quads or primary energy annually, or nearly 30% of all energy used in the U.S. commercial and residential buildings. Electrochemical compression (ECC) is a transformative solid-state technology and ECC based HVAC systems could result in 40% less energy use. The goal of the project was to develop the most efficient, noiseless, and most environmentally friendly cooling system based on integrating 2 (two) technologies: a) electrochemical compressors (ECC) to replace mechanical compressors for use in building heating, ventilation, and air conditioning (HVAC) applications and b) Ionic Liquid Desiccant Systems. The overall objective was to develop and build a scalable ILD/ECC-based air conditioning system operating with a COP of 4.5, with a price premium of $70 installed per kBTU/hr.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ARM Aerial Instrument Workshop Report

The mission of the U.S. Department of Energy’s (DOE) Biological and Environmental Research (BER) program is to “support transformative science and scientific user facilities to achieve a predictive understanding of complex biological, earth, and environmental systems for energy and infrastructure security, independence, and prosperity.” (https://science.osti.gov/ber) Aligned with the BER central mission, the Earth and Environmental Systems Sciences Division (EESSD) plays a vital role in supporting the fundamental research to understand and predict Earth’s climate and environmental systems, and is also in a unique position to inform the development of sustainable solutions to the nation’s energy and environmental challenges. Specifically, EESSD manages two scientific user facilities: the Atmospheric Radiation Measurement (ARM) user facility and the Environmental Molecular Sciences Laboratory (EMSL). These facilities provide the broader scientific community with scientific expertise, technical capabilities, and unique data sets to facilitate science in areas of importance to DOE. As a multi-platform scientific user facility, ARM aims to fulfill the needs predominantly within the EESSD Atmospheric System Research (ASR) and the Earth and Environmental System Modeling (EESM) mission areas, and provide the critical measurements required to improve understanding of aerosol and cloud life cycles and their interactions, and their coupling with the Earth’s surface. Over the years, ARM has carried out piloted and unmanned aircraft campaigns under different organizational and operational paradigms (Schmid et al. 2014, 2016). Building on its success, the ARM Aerial Facility (AAF) continues to complement the ground-based observations with airborne in situ cloud, aerosol, and trace gas observations as well as measurements of atmospheric state and atmospheric radiation. During the past three years, ARM has managed field campaigns using unmanned aerial systems (UAS) and tethered balloon systems (TBS) at Oliktok Point in Alaska to improve understanding of atmospheric processes in the Arctic. In 2019, following a careful evaluation of scientific community needs, ARM acquired a Bombardier Challenger 850 regional jet to replace the vintage Grumman Gulfstream-159 turboprop aircraft previously used by AAF. With this new “laboratory in the sky”, AAF is evaluating its current and future aerial observation capabilities to continue satisfying the needs of the research community.

54 ENVIRONMENTAL SCIENCES↗

Quantum Zeno Control of Superconducting Qubit Coherence

The Quantum Zeno Effect (QZE) dictates how the dynamics of a quantum system can be modified through continuous or discrete measurements [1]. It has gained increasing attention in quantum computing community in recent years, both due to its inevitable implications for qubit readout as well as for its promise for enabling new methods of quantum state control such as reservoir engineering and Zeno-dragging. Here, we investigate Zeno effects implemented via weak measurements for controlling superconducting-qubit coherence during gate and readout operations in a multi-qubit setup. Building on prior observations [2] that measurement backaction can both suppress and enhance qubit relaxation, we predict and measure QZE-altered qubit coherence times by manipulating the spectral overlap of qubit spectrum with background noise sources. We also discuss modifications and opportunities for controllable QZE due to anharmonic effects in multi-level superconducting atoms. [1] S. Greenfield, A. Kamal, J. Dressel, E. Levenson-Falk, arXiv:2506.12679 (2025) [2] Thorbeck, Z. Xiao, L. Govia, A. Kamal, Phys. Rev. Lett. 132, 090602 (2024)

Seidel, Olivia [Texas U., Arlington; Fermilab]↗

A Multi-Dimensional Benefit Assessment of Automated Mobility Platforms (AMP) for Large Facilities

Automated Mobility Platform (AMP) is a general term for intelligently managed passenger mobility systems that leverage automation and electrification to improve system performance and sustainability through the integration of real-time data streams with advanced decision-making processes tailored for use in large facilities. Using airports as an example, the rapid growth in air travel demand has led to facility expansions and congested terminals, which directly impacts equity (e.g., increased challenges for passengers with reduced mobility [PRMs]) and sustainability - both of which are important metrics often neglected during the engineering design process. Therefore, to evaluate systems and inform critical decisions more effectively, a holistic evaluation framework is proposed that includes equity, sustainability, and infrastructure perspectives - referred to as a multidimensional benefit assessment. More specifically, the following analysis focuses on: (1) mobility, with emphasis on travel time and accessibility within an airport, contrasting existing systems with the proposed AMP system; (2) equity analysis, specifically to the PRM community, but with an eye to the whole of society; (3) energy consumption and greenhouse gas (GHG) emissions associated with intra-airport mobility, comparing and contrasting modes as well as impacts on overall airport operations efficiency; and (4) fundamental changes in building design enabled by AMPs for larger and more flexible, functional, and energy-efficient structures.

ADVANCED PROPULSION SYSTEMS↗

The HRA/Solarium Project: Feedback Based on 20 Years of Experience in Treatment of Medium Level Waste - 20185

Since the 1980's the management of the historical site of Mol has been transferred to the National Agency for Radioactive Waste and Enriched Fissile Materials (ONDRAF/NIRAS). Belgoprocess is entrusted by ONDRAF/NIRAS with the operational waste management and site remediation. One of the major challenges has been the characterization, treatment and conditioning of approximately 200 m{sup 3} of medium level waste. These waste packages were stored in poor conditions in storage vaults ('HRA') or concrete containers ('Solarium'). They have been produced in various research programs and reactor operations at the Belgian nuclear energy research centre SCK.CEN, isotope production, decontamination and dismantling operations from the 1960's up to the 1980's. Despite the limited volume, this historical waste consists of a great variation of waste characteristics and waste configurations. To tackle these liabilities, a new processing facility was built in the 1990's to allow safe transfers, handling, characterization and treatment of these packages. Also some auxiliary facilities have been built to deal with the by-products, like emptied concrete containers. The engineering of the installation, safety procedures and (characterization) methodology that has been developed generically have been proved to be successful. Nevertheless, the specific nature of some items made it necessary to organize a step-by-step treatment in distinct campaigns in which some relevant extra (safety) measures had to be taken into account. This dynamic approach made it possible to process a great variety of waste types in order to to ensure that this legacy is no longer left for subsequent generations. After about 20 years of operations, there has been a great build-up of experience and feed-back concerning the waste management of these specific waste streams. Some cases will be highlighted to specify the approach followed for treatment of e.g.: - Na/NaK containing equipment; - spent radioactive sources; - fuel element residues; - medium level waste originating from activation experiments; - radium bearing medium level waste originating from Ac-227 production research. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Model Energy Codes End-Use Opportunity Analysis

Model energy codes (ASHRAE Standard 90.1 and IECC) has significantly impacted programs and policies aimed at improving energy efficiency both in United States and across the globe. Standard 90.1, first published in 1975 (originally referred to as Standard 90) provides minimum energy efficiency guidelines for designing, constructing, operating, and maintaining new construction and renovated buildings. It is updated continuously, with new editions published every 3 years. Pacific Northwest National Laboratory (PNNL) conducts simulated energy and cost savings analysis of model energy codes to determine their expected impact and to track progress toward net-zero goals and efficiency targets. Additionally, the simulation outputs are examined to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles. This end-use opportunity analysis of model energy codes provides ASHRAE technical committees and other interested parties a better understanding of how the Standard affects various building systems and end uses, specifically, those in the Standard that most prominently influence energy efficiency. Additionally, findings provide industry stakeholders guidance in identifying building types and end-uses with the most potential for energy efficiency improvements through energy codes and those that may require beyond code measures to meet energy use reduction targets. This paper summarizes features and functionalities of a webtool created by PNNL to explore and visualize the End-Use opportunity analysis.

ASHRAE 90.1, Energy Codes, Tableau↗

Capabilities for Water Sector Infrastructure Resilience - Prioritizing RD&D in a Target Rich, Resource Poor Sector

WSTB & Water Sector Security Program Expansion Objective: Incubate and shepherd a public-private consortium of joint seal US government sponsors and industry stakeholders to build out industrial control system (ICS) and operational technology (OT) architecture of the Idaho National Laboratory (INL) Water Security Test Bed (WSTB) asset to enable research, testing, and cyber workforce training related to evolving cyber-physical and physical vulnerabilities and threats in the water sector.

99 - GENERAL AND MISCELLANEOUS↗

All Systems Go: Regional Collaborations for Scaling AEC Innovation: Preprint

The high and rising cost of preserving and delivering housing in the U.S. requires changes to existing practices of finance, design, and construction. Innovative methods such as industrialized construction could offer the means to address housing undersupply while reducing delivery costs, operational costs and material waste in the building industry, but they face challenges to success and to scale. Simultaneously, construction and cleantech innovators themselves face skepticism from the traditional entrepreneurial ecosystem such as incubators and accelerators while attempting to navigate systems level challenges. To respond to this need, various public and private sector stakeholders have launched initiatives to support innovative companies. These include nonprofits such as Terner Labs and Ivory Innovations offering curated programming to architecture, engineering, and construction (AEC) startups; housing developers in Minnesota and California "bundling" multiple projects together to reach economies of scale with a consistent project team; public and private sector entities developing "catalogues" of pre-approved home designs in the U.S. and Canada. This exploratory paper documents several of these emerging ecosystem-development efforts to support innovative housing approaches, characterizing them by leading stakeholder and intervention strategy based on publicly available information. The paper finds that these initiatives share similar high level goals but vary in implementation, reflecting different stakeholder priorities, regional market and policy dynamics, and housing typologies. The early stage of these efforts offer limited data for comparing actual outcomes, but the paper highlights common qualitative themes and identifies opportunities for further research and potential coordination among these efforts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗