Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building data management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial Building Motor Protection Response Report

When voltages recover, motors may immediately reenergize and reaccelerate, or delay for a few minutes, or stay stalled. The estimated motor response is given for both the voltage sag magnitude and voltage sag duration. These response estimates are based on experience and available test data. Good data is available for voltage sag response for many components such as relays and contactors, but little data is available for both voltage sag and recovery response. The tables in Appendix A include data from recent voltage sag and recovery tests performed by SCE and BPA on air conditioners and energy management systems. The response of the motor can vary greatly depending on the type of protection and control. The time duration for the voltage sag consists of those times that are of interest for bulk power system modelers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calculator for Agricultural Water Use Fractions in California

Improved quantification of agricultural water use efficiency is a primary focus of California's Water Conservation Act. The California Department of Water Resources (CDWR), after extensive stakeholder consultation, has published methods and indicators to help identify opportunities for improved efficiency of irrigation management at various spatial scales. Additional 2017 legislation directs water suppliers to quantify water use efficiency using the CDWR metrics to support preparation of agricultural water management plans. The IrriQuest calculator derives the Crop Consumptive Use Fraction (CCUF), a foundational metric relating seasonal crop evapotranspiration (ET) to total applied water. Satellite normalized difference vegetation index (NDVI) data are used to develop fractional canopy cover timeseries. Additional key inputs include daily reference ET, irrigation volume, irrigation method, precipitation, soil texture and crop type. IrriQuest estimates of seasonal crop ET show less than 10% mean absolute error compared to ground-based measurements of several annual and perennial crops monitored by sensor deployment in commercial fields. Two additional indicators build on CCUF. The Agronomic Water Use Fraction adds consideration of water applied for beneficial purposes such as pre-plant soil preparation, soil salinity management, and climate control. Total Water Use Fraction additionally accounts for water applied for environmental purposes such as maintenance of wetland and riparian habitat. A convenient on-line portal is under development for CCUF estimation and a standalone spreadsheet is available for computation of all three use fractions.

Calculator↗

Space-based Sensor for Extreme Fire Weather Events

Catastrophic bushfires are becoming increasingly prevalent as climate change advances. Impacts extend beyond national borders. Multinational efforts can inform new science and management practices. Space-based sensors and integrated data facilities will play an important role. This paper describes a collaborative project between a consortium of Australian universities and NASA Centers to develop and implement a small satellite platform comprising highly integrated thermal and lightning sensors coupled with AI-based edge computing to help predict, detect, and track bushfires, supporting mitigation activities. This will fill an important capability gap since Australia does not currently have any sovereign Earth observation satellites. This program is enabled by and builds on Australia-NASA collaboration and will also support fire science and management activities in the broader global context.

wildfire↗

AI-Based Analytics and Energy Modeling Framework for Characterizing Urban Energy Systems

Developing location-specific district energy models is essential for understanding energy patterns and supporting efficient management and planning decisions. However, accurately characterizing these models remains challenging due to gaps in building characteristics and labor-intensive traditional modeling workflows. To address these challenges, we develop an AI-based framework that integrates top-down and bottom-up building energy data to automate urban energy model characterization. The framework trains multimodal deep learning models using heterogeneous ResStockTM datasets to infer missing building characteristics from varying levels of known information and generate simulation-ready inputs for district-scale energy modeling. It also employs a conditioning-based injection approach to generate ”what-if” scenarios, enabling users to explore retrofit, efficiency, and technology-upgrade pathways. Integrated within URBANoptTM, a bottom-up district energy modeling platform for simulating co-located buildings, the framework infers detailed building-level inputs required for bottom-up simulations. Both localized and generalized AI models are developed to learn relationships across categorical, numerical, and time-series data, enabling reconstruction of missing attributes and generation of targeted upgrade scenarios. We demonstrate this methodology on a residential neighborhood in Baltimore, MD, assessing internal consistency against ResStock reference data and URBANopt simulation, and comparing selected attributes against real-world building characteristics. Results show strong overall predictive accuracy in data completion and scenario generation, with localized and generalized models offering complementary trade-offs between precision and scalability. Overall, our automated framework streamlines energy modeling and provides a reliable framework for urban building energy characterization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling real-time multi-messenger astrophysics discoveries with deep learning

Multi-messenger astrophysics is a fast-growing, interdisciplinary field that combines data, which vary in volume and speed of data processing, from many different instruments that probe the Universe using different cosmic messengers: electromagnetic waves, cosmic rays, gravitational waves and neutrinos. In this Expert Recommendation, we review the key challenges of real-time observations of gravitational wave sources and their electromagnetic and astroparticle counterparts, and make a number of recommendations to maximize their potential for scientific discovery. These recommendations refer to the design of scalable and computationally efficient machine learning algorithms; the cyber-infrastructure to numerically simulate astrophysical sources, and to process and interpret multi-messenger astrophysics data; the management of gravitational wave detections to trigger real-time alerts for electromagnetic and astroparticle follow-ups; a vision to harness future developments of machine learning and cyber-infrastructure resources to cope with the big-data requirements; and finally, the need to build a community of experts to realize the goals of multi-messenger astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-P-10: A Web-Based Radiation Safety Relational Database Module for Regulatory Compliance

Purpose: Maintaining compliance with Radioactive Materials Licenses is inherently a time-consuming task requiring focus and attention to detail. Staff tasked with these responsibilities, such as the Radiation Safety Officer and associated personnel must retain disparate records for eventual placement into one or more annual reports. Entering results and records in a relational database using a web browser as the interface, and storing that data in a cloud-based storage site, removes procedural barriers. The data becomes more adaptable for mining and sharing. Methods: Web-based code was written utilizing the web framework Django, written in Python. Additionally, the application utilizes JavaScript for front-end interaction, SQL, HTML and CSS. Quality assurance code testing is performed in a sequential style, and new code is only added after the successful testing of the previous goals. Separate sections of the module include data entry and analysis for audits, surveys, quality management, and continuous quality improvement. Data elements can be adapted for quarterly and annual reporting, and for immediate notification of user determined alarm settings. Results: Current advances are focusing on user interface issues, and determining the simplest manner by which to teach the user to build query forms. One solution has been to prepare library documents that a user can select or edit in place of creation a new document. Forms are being developed based upon Nuclear Regulatory Commission federal code, and will be expanded to include State Regulations. Conclusion: Establishing a secure website to act as the portal for data entry, storage and manipulation can lead to added efficiencies for a Radiation Safety Program. Access to multiple databases can lead to mining for big data programs, and for determining safety issues before they occur. Overcoming web programming challenges, a category that includes mathematical handling, is providing challenges that are being overcome.

61 RADIATION PROTECTION AND DOSIMETRY↗

Redesign of the Timeline Generator at Fermilab using a web-based Flutter application, GraphQL API and an IOC

The control system at Fermilab is undergoing an evolution with a shift towards web-based applications with connections to the EPICS infrastructure. The Timeline Generator (TLG) is an application that serves to coordinate events across the lab using different timing links. These links include the Tevatron clock (TCLK), a 10 MHz serial link with events encoded at 20Hz and Machine Data (MDAT), a communication link with states encoded at 720Hz. This paper covers the redesign of the major components of the TLG. This includes a web-based Flutter application for building timelines. A placement service is in use that has a GraphQL interface and uses a timeline input to compute a schedule of events and states. The Flutter application sends this computed schedule to the TLG IOC via a GraphQL interface to the Data Pool Manager (DPM). The TLG IOC runs on an Arria FPGA, the Accelerator Clock Generator (ACLK-GEN), which is responsible for writing the events and states on to the different timing links.

Carmichael, Linden [Fermilab]↗

Redesign of the Timeline Generator at Fermilab using a web-based Flutter Application, GraphQL API and an IOC

Redesign of the Timeline Generator at Fermilab using a web-based Flutter application, GraphQL API and an IOC ABSTRACT = The control system at Fermilab is undergoing an evolution with a shift towards web-based applications with connections to the EPICS infrastructure. The Timeline Generator (TLG) is an application that serves to coordinate events across the lab using different timing links. These links include the Tevatron clock (TCLK), a 10 MHz serial link with events encoded at 20Hz and Ma-chine Data (MDAT), a communication link with states encoded at 720Hz. This paper covers the redesign of the major components of the TLG. This includes a web-based Flutter application for building timelines. A placement service is in use that has a GraphQL interface and uses a timeline input to compute a schedule of events and states. The Flutter application sends this computed schedule to the TLG IOC via a GraphQL interface to the Data Pool Manager (DPM). The TLG IOC runs on an Arria FPGA, the Accelerator Clock Generator (ACLK-GEN), which is responsible for writing the events and states on to the different timing links.

Carmichael, Linden [Fermilab]↗

Launch and Landing Effects Ground Operations (LLEGO) Model

LLEGO is a model for understanding recurring launch and landing operations costs at Kennedy Space Center for human space flight. Launch and landing operations are often referred to as ground processing, or ground operations. Currently, this function is specific to the ground operations for the Space Shuttle Space Transportation System within the Space Shuttle Program. The Constellation system to follow the Space Shuttle consists of the crewed Orion spacecraft atop an Ares I launch vehicle and the uncrewed Ares V cargo launch vehicle. The Constellation flight and ground systems build upon many elements of the existing Shuttle flight and ground hardware, as well as upon existing organizations and processes. In turn, the LLEGO model builds upon past ground operations research, modeling, data, and experience in estimating for future programs. Rather than to simply provide estimates, the LLEGO model s main purpose is to improve expenses by relating complex relationships among functions (ground operations contractor, subcontractors, civil service technical, center management, operations, etc.) to tangible drivers. Drivers include flight system complexity and reliability, as well as operations and supply chain management processes and technology. Together these factors define the operability and potential improvements for any future system, from the most direct to the least direct expenses.

Source record↗

TPSAS-NF1676L-33992-DND

The CERES Science Team integrates and fuses observations from 6 CERES instruments aboard the Terra, Aqua, S-NPP, and NOAA-20 missions with data from more than 20 other unique data sources. Following the November 2017 launch of CERES Flight Model 6 (FM6) onboard NOAA20, CERES has now amassed over 80 instrument-years of valuable Earth radiation budget data. The rapidly growing volume of CERES data coupled with the introduction of new data products alongside improvements to existing science algorithms fosters the requirement for faster, more flexible, and scalable data production and orchestration. New virtualized, cloud-centric compute hardware hosted by the NASA Langley Research Center’s (LaRC) Atmospheric Sciences Data Center (ASDC) provides an ideal environment for these ever-increasing data production demands for CERES. This poster discusses updates to the implementation of the CERES Data Management Team’s (DMT) CERES AuTomAted job Loading sYSTem (CATALYST), a custom data processing workflow engine for CERES, to use on-demand computing resources to perform automated CERES data production processing in a Linux-based container environment. Linux containers provide CERES the flexibility to build multiple production environments in containers tailored for specific workloads and allow effortless provisioning of resources based on the CERES Science Team’s data production requirements.

Thomas N. Hillyer↗

Notification of Concurrence - K-25/K-27 D&D Project, ETTP - Change Number of EMWMF Waste Lots in the Waste Handling Plan for Demolition of the K-25 and K-27 Building Structures and Remaining Components Located at the ETTP, Oak Ridge, TN From Two to Three

Section 5.1 of the approved Waste Handling Plan for Demolition ofthe K-25 and K-2 7 Building Structures and Remaining Components Located at the East Tennessee Technology Park, Oak Ridge, Tennessee (WHP) includes two Environmental Management Waste Management (EMWMF) waste lots: (1) Asbestos-contaminated roofing/transite; and (2) Construction debris, such as nonasbestos roofing, structural steel/miscellaneous metal/equipment, nonradiological piping, wood, and miscellaneous small quantities of concrete. This concurrence form adds an additional EMWMF waste lot 6.47 for lavatory sink drains. Based on an analysis of the building structure characterization data, the only individual building structure with either an analytic carcinogenic or Hazard Index (HI) sum-of-fractions (SOF) greater than 1 is the lavatory sink drains (Table 1). The HI SOF for the lavatory sink drains is 1.34 (Table 2). When all media are combined with the material of construction calculations, the HI SOF is 1.22 (Table 3). However, when the lavatory sink drains are segregated from all other media, the HI SOF is only 0.256, which is well below the EMWMF waste acceptance criteria SOF limit of 1 (Table 4). Given the large volume (124, 625 cubic yards) of other building structure media with a small HI SOF of 0.256 and the small volume (one cubic yard) of lavatory sink drains with a large HI SOF of 1.34, a separate waste lot for lavatory sink drains is recommended. Lead is the primary contributor to the large HI SOF in the lavatory sink drains. Lead in the lavatory sink drains was shown using the Wilcoxon rank-sum test statistically to have higher concentrations than all other building structure media combined. Other analytes having statistically different median concentrations in the lavatory sink drains compared to all other media are antimony, arsenic, boron, cadmium, selenium, solver, vanadium, zinc, mercury, strontium, and Uranium-233/234 (Table 5). A separate waste lot for the lavatory sink drains minimizes the volume weighted sum-of fractions since a much smaller volume of waste will have the higher HI SOF of 1.34, while a much larger volume of waste will have a small HI SOF of 0.256.

54 ENVIRONMENTAL SCIENCES↗

MARSAME Release Report for TA46 Building 1

Environmental Protection and Compliance, Environmental Stewardship (EPC-ES) has identified materials associated with technical area 46, Building 1 (TA-46-001) that meet the criteria for unrestricted release to the public under Department of Energy (DOE) Order 458.1 Radiation Protection for the Public and the Environment (DOE 2013). We have also identified materials in certain rooms, e.g., ventilation systems and liquid drains and piping, which do not meet the criteria for unrestricted release and are to be treated as Low Level Waste (LLW). These conclusions are based on the known history of the structures combined with radiation survey data collected in 2018, and findings are consistent with DOE Order 458.1 and Los Alamos National Laboratory (LANL) Functional Series Document EPC-ES-FSD-004, Environmental Radiation Protection (LANL 2017). Sampling and data analysis, as described in this report, were sufficient to meet measurement quality objectives under the Multi-Agency Radiation Survey and Assessment of Materials and Equipment (MARSAME) manual (MARSAME 2009) and LANL procedures (LANL 2015). Final approvals for waste disposition will come from LANL’s Waste Management Program. The scope of this final release report includes structure TA-46-001. Floorplans for building 46-001 are provided in Figures 2 through 4. Metal materials included in this report are not subject to the DOE metal moratorium. While MARSAME provides guidance on statistical sampling for residual radionuclides in bulk materials, smaller miscellaneous items can be released via the release procedures outlined in LANL Policy 121 Radiation Protection (LANL 2018).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Managing the On-Board Data Storage, Acknowledgement and Retransmission System for Spitzer

The Spitzer Space Telescope has a two-phase downlink system. Recorded data are transmitted during one telecom session. Then commands are sent during the next session to delete those data that were received on the ground and to retransmit those data that were missed. We must build science sequences that are as efficient as possible to make the best use of our supply of liquid helium. One way to improve efficiency is to use only the minimum time needed during telecom sessions to transmit the predicted volume of data. But, we must also not fill the on-board storage and must allow enough time margin to retransmit missed data. We describe tools and procedures that allow us to build science sequences that are single-fault tolerant in this regard and that allow us to recover quickly and safely from anomalies that affect the receipt or acknowledgment (i.e. deletion) of data.

on-board storage↗

Smart building management vs. intuitive human control—Lessons learnt from an office building in Hungary

We report that smart building management and control are adopted nowadays to achieve zero-net energy use in buildings. However, without considering the human dimension, technologies alone do not necessarily guarantee high performance in buildings. An office building was designed and built according to state-of-the-art design and energy management principles in 2008. Despite the expectations of high performance, the owner was facing high utility bills and low user comfort in the building located in Budapest, Hungary. The objective of the project was to evaluate the energy performance and comfort indices of the building, to identify the causes of malfunction and to elaborate a comprehensive energy concept. Firstly, current building conditions and operation parameters were evaluated. Our investigation found that the state-of-the-art building management system was in good conditions but it was operated by building operators and occupants who are not aware of the building management practice. The energy consumption patterns of the building were simulated with energy modelling software. The baseline model was calibrated to annual measured energy consumption, using actual occupant behaviour and presence, based on results of self-reported surveys, occupancy sensors and fan-coil usage data. Realistic occupant behaviour models can capture diversity of occupant behaviour and better represent the real energy use of the building. This way our findings and the effect of our proposed improvements could be more reliable. As part of our final comprehensive energy concept, we proposed intervention measures that would increase indoor thermal comfort and decrease energy consumption of the building. A parametric study was carried out to evaluate and quantify energy, comfort and return on investment of each measure. It was found that in the best case the building could save 23% of annual energy use. Lastly, future work includes the follow-up of: occupant reactions to intervention measures, the realized energy savings, the measurement of occupant satisfaction and behavioural changes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Deep reinforcement learning with online data augmentation to improve sample efficiency for intelligent HVAC control

Deep Reinforcement Learning (DRL) has started showing success in real-world applications such as building energy optimization. Much of the research in this space utilized simulated environments to train RL-agent in an offline mode. Very few research have used DRL-based control in real-world systems due to two main reasons: 1) sample efficiency challenge---DRL approaches need to perform a lot of interactions with the environment to collect sufficient experiences to learn from, which is difficult in real systems, and 2) comfort or safety related constraints---user's comfort must never or at least rarely be violated. In this work, we propose a novel deep Reinforcement Learning framework with online Data Augmentation (RLDA) to address the sample efficiency challenge of real-world RL. We used a time series Generative Adversarial Network (TimeGAN) architecture as a data generator. We further evaluated the proposed RLDA framework using a case study of an intelligent HVAC control. With a ≈28% improvement in the sample efficiency, RLDA framework lays the way towards increased adoption of DRL-based intelligent control in real-world building energy management systems.

Kurte, Kuldeep↗

EEB Hub Regional Sankey Diagram: Philadelphia Authority for Industrial Development Historical and Forecast Energy by Planned Use at the Philadelphia Navy Yard

The Energy Efficient Buildings Hub (EEB Hub) is a DOE-funded center, focused on improving the energy use in commercial and large-scale residential buildings. One of the Hub’s goals has been to develop the means and methods to reduce energy use in commercial buildings by 20 percent by 2020. Understanding energy use in buildings is a key component to managing energy use at multiple scales, from the building to the city, to the region. Sankey diagrams are an accessible tool to visualize energy flows, and help identify opportunities to deploy energy saving technologies. A campus-level Sankey diagram was previously generated from 2010-2011 data for ~100 metered Navy Yard buildings to quantify natural gas and electricity usage by principal building activity. As these properties are renovated, the energy consumption and building principal activities are being updated and modified. To depict the multi-year time lapse of regional electricity distribution in the Navy Yard, LLNL generated Sankey diagrams using data from 36 properties (buildings, developments, equipment) used to develop Philadelphia Authority for Industrial Development’s (PIDC) Navy Yard Master Energy Plan (NYEMP). The diagrams presented in this report depict ~10 building use types and the yearly changes in forecasted usage in GWh from 2011 to 2022. The forecast captures increases in regional energy use from planned building additions and renovations and yearly increases for existing buildings. From 2009 to 2022, there is approximately 5.6 million square feet of planned additions and renovations. The largest addition of properties are for office (~ 2.3 million square feet for dedicated office, and larger for shared office space) and residential space (~1 million square feet). Until 2014, the largest user of energy is for flex space, reaching a forecasted 11.4 GWh. In 2015-2016, the largest forecasted user is for a data center reaching ~25.7 GWh. After 2016, the largest consumers are either for office space (reaching 63.2 GWh forecast in 2022), or heavy industry (68 GWh forecast in 2022).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗