Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “blindness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Mixing stops at the LHC

We study the phenomenology of a light stop NLSP in the presence of large mixing with either the first or the second generation. R-symmetric models provide a prime setting for this scenario, but our discussion also applies to the MSSM when a significant amount of mixing can be accommodated. In our framework the dominant stop decay is through the flavor violating mode into a light jet and the LSP in an extended region of parameter space. There are currently no limits from ATLAS and CMS in this region. We emulate shape-based hadronic SUSY searches for this topology, and find that they have potential sensitivity. If the extension of these analyses to this region is robust, we find that these searches can set strong exclusion limits on light stops. If not, then the flavor violating decay mode is challenging and may represent a blind spot in stop searches even at 13 TeV. Thus, an experimental investigation of this scenario is well motivated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beyond Higgs couplings: Probing the Higgs with angular observables at future e$^{+}$e$^{-}$ colliders

Here, we study angular observables in the $ {e}^{+}{e}^{-}\to ZH\to {\ell}^{+}{\ell}^{-}b\overline{b} $ channel at future circular e$^{+}$ e$^{-}$ colliders such as CEPC and FCC-ee. Taking into account the impact of realistic cut acceptance and detector effects, we forecast the precision of six angular asymmetries at CEPC (FCC-ee) with center-of-mass energy $ \sqrt{s}=240 $ GeV and 5 (30) ab$^{-1}$ integrated luminosity. We then determine the projected sensitivity to a range of operators relevant for he Higgs-strahlung process in the dimension-6 Higgs EFT. Our results show that angular observables provide complementary sensitivity to rate measurements when constraining various tensor structures arising from new physics. We further find that angular asymmetries provide a novel means of both probing BSM corrections to the HZγ coupling and constraining the “blind spot” in indirect limits on supersymmetric scalar top partners.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Higgs portals for thermal Dark Matter. EFT perspectives and the NMSSM

We analyze a low energy effective model of Dark Matter in which the thermal relic density is provided by a singlet Majorana fermion which interacts with the Higgs fields via higher dimensional operators. Direct detection signatures may be reduced if blind spot solutions exist, which naturally appear in models with extended Higgs sectors. Explicit mass terms for the Majorana fermion can be forbidden by a $Z_3$ symmetry, which in addition leads to a reduction of the number of higher dimensional operators. Moreover, a weak scale mass for the Majorana fermion is naturally obtained from the vacuum expectation value of a scalar singlet field. The proper relic density may be obtained by the $s$-channel interchange of Higgs and gauge bosons, with the longitudinal mode of the $Z$ boson (the neutral Goldstone mode) playing a relevant role in the annihilation process. This model shares many properties with the Next-to-Minimal Supersymmetric extension of the Standard Model (NMSSM) with light singlinos and heavy scalar and gauge superpartners. In order to test the validity of the low energy effective field theory, we compare its predictions with those of the ultraviolet complete NMSSM. Extending our framework to include $Z_3$ neutral Majorana fermions, analogous to the bino in the NMSSM, we find the appearance of a new bino-singlino well tempered Dark Matter region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncovering acoustic signatures of pore formation in laser powder bed fusion

Abstract We present a machine learning workflow to discover signatures in acoustic measurements that can be utilized to create a low-dimensional model to accurately predict the location of keyhole pores formed during additive manufacturing processes. Acoustic measurements were sampled at 100 kHz during single-layer laser powder bed fusion (LPBF) experiments, and spatio-temporal registration of pore locations was obtained from post-build radiography. Power spectral density (PSD) estimates of the acoustic data were then decomposed using non-negative matrix factorization with custom $$\varvec{k}$$ k -means clustering (NMF $$\varvec{k}$$ k ) to learn the underlying spectral patterns associated with pore formation. NMF $$\varvec{k}$$ k returned a library of basis signals and matching coefficients to blindly construct a feature space based on the PSD estimates in an optimized fashion. Moreover, the NMF $$\varvec{k}$$ k decomposition led to the development of computationally inexpensive machine learning models which are capable of quickly and accurately identifying pore formation with classification accuracy of supervised and unsupervised label learning greater than 95% and 90%, respectively. The intrinsic data compression of NMF k , the relatively light computational cost of the machine learning workflow, and the high classification accuracy makes the proposed workflow an attractive candidate for edge computing toward in-situ keyhole pore prediction in LPBF.

36 MATERIALS SCIENCE↗

Differentiation of pancreatic neuroendocrine tumors from pancreas renal cell carcinoma metastases on CT using qualitative and quantitative features

Purpose: To assess qualitative and quantitative imaging features on enhanced CT that may differentiate pancreatic neuroendocrine tumors (PNETs) from pancreatic renal cell carcinoma (RCC) metastases. Methods: This IRB-approved multi-center retrospective case–control study compared 43 resected PNETs and 28 resected RCC metastases with pre-operative enhanced CT identified consecutively between 2003 and 2017. Two blinded radiologists (R1/R2) independently assessed tumor location, attenuation (relative to pancreas), composition (solid/cystic/mixed), homogeneity (homogeneous/heterogeneous), calcification, multiplicity, and for main pancreatic duct (MPD) dilation. Tumors were segmented for quantitative texture analysis. Data were analyzed with Chi square, logistic regression, and receiver operating characteristic (ROC). Inter-observer agreement was assessed (Cohen’s kappa). Results: There was no difference in age, gender, location, attenuation, or composition (P > 0.05) between groups. PNETs were larger than RCC metastases (37 ± 23 mm vs. 26 ± 21 mm, P = 0.038), more frequently solitary (P < 0.001), subjectively more heterogeneous (P = 0.033/0.144, R1/R2), and associated with calcification (P = 0.002/0.004) and MPD dilation (P = 0.025/0.006). Agreement for subjective features was moderate-to-almost perfect (K = 0.4879–0.9481). Quantitative texture analysis showed higher entropy in PNETs (6.32 ± 0.49 versus 5.96 ± 0.53; P = 0.004) with no difference in other features studied (P > 0.05). Entropy had ROC area under the curve for diagnosis of PNET of 0.77 ± 0.06, with optimal sensitivity/specificity of 71.4/79.1%. Conclusions: Compared to pancreatic RCC metastases, PNETs are larger, more frequently solitary, contain calcification, show MPD dilation, and are subjectively and quantitatively more heterogeneous tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of a DIXON-based fat quantification technique for the measurement of visceral fat using a CT-based reference standard

Purpose: The purpose of the study is to determine whether a novel semi-automated DIXON-based fat quantification algorithm can reliably quantify visceral fat using a CT-based reference standard. Methods: This was an IRB-approved retrospective cohort study of 27 subjects who underwent abdominopelvic CT within 7 days of proton density fat fraction (PDFF) mapping on a 1.5T MRI. Cross-sectional visceral fat area per slice (cm{sup 2}) was measured in blinded fashion in each modality at intervertebral disc levels from T12 to L4. CT estimates were obtained using a previously published semi-automated computational image processing system that sums pixels with attenuation − 205 to − 51 HU. MR estimates were obtained using two novel semi-automated DIXON-based fat quantification algorithms that measure visceral fat area by spatially regularizing non-uniform fat-only signal intensity or de-speckling PDFF 2D images and summing pixels with PDFF ≥ 50%. Pearson’s correlations and Bland–Altman analyses were performed. Results: Visceral fat area per slice ranged from 9.2 to 429.8 cm{sup 2} for MR and from 1.6 to 405.5 cm{sup 2} for CT. There was a strong correlation between CT and MR methods in measured visceral fat area across all studied vertebral body levels (r = 0.97; n = 101 observations); the least (r = 0.93) correlation was at T12. Bland–Altman analysis revealed a bias of 31.7 cm{sup 2} (95% CI [− 27.1]–90.4 cm{sup 2}), indicating modestly higher visceral fat assessed by MR. Conclusion: MR- and CT-based visceral fat quantification are highly correlated and have good cross-modality reliability, indicating that visceral fat quantification by either method can yield a stable and reliable biomarker.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pain in percutaneous liver core-needle biopsy: a randomized trial comparing the intercostal and subcostal approaches

Purpose: Effective pain control during and after percutaneous core needle liver biopsy is important with regard to ethical considerations and patient comfort. In this randomized double-blind study, we compared post-biopsy pain in the patients undergoing liver core-needle biopsy using either subcostal or intercostal approaches. Methods: All patients referred for ultrasound-guided CNLB between July 2017 and January 2018 to our interventional radiology department were randomized into two groups. Biopsy was performed through intercostal approach in the first group and through subcostal approach in the second group. The intensity of pain 0, 2, and 4 h after the procedure was compared in two groups using a 100-mm visual analogue scale. All biopsies were performed without procedural IV sedation. If patients’ discomfort demanded administration of IV analgesics during or after the procedure, then the patients were excluded from the study. Results: In patients without routine procedural IV sedation, there was no significant difference in the pain level between the intercostal and subcostal groups immediately after the procedure (p = 0.055), but we found a significant difference in the pain level between the two groups 2 (7.5 mm, p = 0.001) and 4 (2 mm, p = 0.001) h after the procedure. Conclusion: The minimum amount of change in the VAS score that is considered clinically important is 13 mm on a 100-mm scale. Pain differences at 2 and 4 h in the two groups in this study were statistically but not clinically significant. Therefore, the authors suggest the use of subcostal route for ultrasound-guided liver biopsy whenever possible, but the results do not warrant the routine use of post-procedure analgesics in whom biopsy is performed via intercostal route.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conical ultrashort echo time (UTE) MRI in the evaluation of pediatric acute appendicitis

Purpose: Magnetic resonance imaging (MRI) sequences with conical k-space trajectories are able to decrease motion artifacts while achieving ultrashort echo times (UTE). We assessed the performance of free-breathing conical UTE MRI in the evaluation of the pediatric pelvis for suspected appendicitis. Methods: Our retrospective review of 84 pediatric patients who underwent MRI for suspected appendicitis compared three contrast-enhanced sequences: free-breathing conical UTE, breath-hold three-dimensional (3D) spoiled gradient echo (BH-SPGR), and free-breathing high-resolution 3D SPGR (FB-SPGR). Two radiologists performed blinded and independent evaluations of each sequence for image quality (four point scale), anatomic delineation (four point scale), and diagnostic confidence (five point scale). Subsequently, the three sequences were directly compared for overall image quality (− 3 to + 3 scale). Scores were compared using Kruskal–Wallis and Wilcoxon signed-rank tests. Results: UTE demonstrated significantly better perceived signal-to-noise ratio (SNR) and fewer artifacts than BH-SPGR and FB-SPGR (means of 3.6 and 3.4, 3.4 and 3.2, 3.1 and 2.7, respectively; p < 0.0006). BH-SPGR and FB-SPGR demonstrated significantly better contrast than UTE (means of 3.6, 3.4, and 3.2, respectively; p < 0.03). In the remaining categories, UTE performed significantly better than FB-SPGR (p < 0.00001), while there was no statistical difference between UTE and BH-SPGR. Direct paired comparisons of overall image quality demonstrated the readers significantly preferred UTE over both BH-SPGR (mean + 0.5, p < 0.00001) and FB-SPGR (mean + 1.2, p < 0.00001). Conclusions: In the evaluation of suspected appendicitis, free-breathing conical UTE MRI performed better in the assessed metrics than FB-SPGR. When compared to BH-SPGR, UTE demonstrated superior perceived SNR and fewer artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporal changes in MRI appearance of the prostate after focal ablation

Purpose: The purpose of our study was to retrospectively evaluate and categorize temporal changes in MRI appearances of the prostate in patients who underwent focal therapy with MRI follow-up. Methods: The Institutional Review Board approved this retrospective study and waived the requirement for informed consent. Thirty-seven patients (median age 61; 48–70 years) with low-to-intermediate-risk, clinically organ-confined prostate cancer underwent focal ablation therapy from 2009 to 2014. Two radiologists reviewed post-treatment MRIs (n = 76) and categorized imaging features blinded to the time interval between the focal therapy and the follow-up MRI. Inter-reader agreement was assessed (kappa) and generalized linear regression was used to examine associations between an imaging feature being present/absent and days between ablation and MRI. Results: Inter-reader agreement on MRI features ranged from fair to substantial. Edema was found present at earlier times after ablation (median 16–25 days compared to MRIs without edema, median 252–514 days), as was rim enhancement of the ablation zone (18–22.5 days vs. 409–593 days), a hypointense rim around the ablation zone on T2-weighted images (53-57.5 days vs. 279–409 days) and the presence of an appreciable ablation cavity (48.5–60 days vs. 613–798 days, all p < 0.05). Enhancement of the ablation zone/scar (553–731 days vs. 61.5–162 days) and the formation of a T2-hypointense scar were found to be present on later MRI scans (514–553 days vs. 29–32 days, one reader). Conclusions: The MRI appearance of the prostate after focal ablation changes substantially over time. Identification of temporal patterns in the appearance of imaging features should help reduce image interpretation variability and errors when assessing post-therapeutic scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive role of PI-RADSv2 and ADC parameters in differentiating Gleason pattern 3 + 4 and 4 + 3 prostate cancer

Purpose: To compare the predictive roles of qualitative (PI-RADSv2) and quantitative assessment (ADC metrics), in differentiating Gleason pattern (GP) 3 + 4 from the more aggressive GP 4 + 3 prostate cancer (PCa) using radical prostatectomy (RP) specimen as the reference standard. Methods: We retrospectively identified treatment-naïve peripheral (PZ) and transitional zone (TZ) Gleason Score 7 PCa patients who underwent multiparametric 3T prostate MRI (DWI with b value of 0,1400 and where unavailable, 0,500) and subsequent RP from 2011 to 2015. For each lesion identified on MRI, a PI-RADSv2 score was assigned by a radiologist blinded to pathology data. A PI-RADSv2 score ≤ 3 was defined as “low risk,” a PI-RADSv2 score ≥ 4 as “high risk” for clinically significant PCa. Mean tumor ADC (ADC{sub T}), ADC of adjacent normal tissue (ADC{sub N}), and ADC{sub ratio} (ADC{sub T}/ADC{sub N}) were calculated. Stepwise regression analysis using tumor location, ADC{sub T} and ADC{sub ratio}, b value, low vs. high PI-RADSv2 score was performed to differentiate GP 3 + 4 from 4 + 3. Results: 119 out of 645 cases initially identified met eligibility requirements. 76 lesions were GP 3 + 4, 43 were 4 + 3. ADC{sub ratio} was significantly different between the two GP groups (p = 0.001). PI-RADSv2 score (“low” vs. “high”) was not significantly different between the two GP groups (p = 0.17). Regression analysis selected ADC{sub T} (p = 0.03) and ADC{sub ratio} (p = 0.0007) as best predictors to differentiate GP 4 + 3 from 3 + 4. Estimated sensitivity, specificity, and accuracy of the predictive model in differentiating GP 4 + 3 from 3 + 4 were 37, 82, and 66%, respectively. Conclusions: ADC metrics could differentiate GP 3 + 4 from 4 + 3 PCa with high specificity and moderate accuracy while PI-RADSv2, did not differentiate between these patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter-radiologist agreement using Society of Abdominal Radiology-American Gastroenterological Association (SAR-AGA) consensus nomenclature for reporting CT and MR enterography in children and young adults with small bowel Crohn disease

Purpose: To assess inter-radiologist agreement using the Society of Abdominal Radiology-American Gastroenterological Association (SAR-AGA) consensus recommendations for reporting CT/MR enterography exams in pediatric and young adult small bowel Crohn disease (CD). Methods: Institutional review board approval was obtained for this HIPAA-compliant retrospective investigation; the requirement for informed consent was waived. 25 CT and 25 MR enterography exams performed in children and young adults (age range: 6–23 years) between January 2015 and April 2017 with a distribution of ileal CD severity (phenotype) were identified: normal or chronic CD without active inflammation (40%), active inflammatory CD (20%), stricturing CD (20%), and penetrating CD (20%). Five fellowship-trained pediatric radiologists, blinded to one another, documented key imaging findings and standardized impressions based on SAR-AGA consensus recommendations. Inter-radiologist agreement was evaluated using Fleiss’ multi-rater kappa statistic (κ) with 95% confidence intervals (CI). Results: Inter-radiologist agreement was moderate for all key imaging findings except presence of ulcerations (κ 0.37 [95% CI 0.28–0.46]) and sacculations (κ 0.31 [95% CI 0.23–0.40]). Agreement for standardized impressions was substantial for stricturing disease (κ 0.79 [95% CI 0.70–0.87]) and moderate for presence of inflammation (κ 0.49 [95% CI 0.44–0.56]) and penetrating disease (κ 0.58 [95% CI 0.49–0.67]). No significant difference in agreement was found between CT and MRI. Conclusions: Agreement among five pediatric radiologists was moderate to substantial for SAR-AGA standardized impressions and fair to moderate for key imaging findings of pediatric and young adult CD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of recurrent pancreatic cancer: value of second-opinion interpretations of cross-sectional images by subspecialized radiologists

Purpose: To investigate the value of second-opinion interpretation of cross-sectional images by subspecialized radiologists to diagnose recurrent pancreatic cancer after surgery. Methods: The IRB approved and issued a waiver of informed consent for this retrospective study. Initial and second-opinion interpretations of 69 consecutive submitted MRI or CT follow-up after pancreatic cancer resection between January 1, 2009 and December 31, 2013 were evaluated by one oncologic imaging radiologist, who was blinded to patient’s clinical details and histopathologic data. The reviewer was asked to classify each interpretation in reference of the diagnosis of PDAC recurrence. It was also recorded if the radiologic interpretation recommended additional imaging studies to confirm recurrence. The diagnosis of recurrence was determined by pathology when available, otherwise by imaging follow-up, clinical, or laboratory assessments. Cohen’s kappa statistic was used to assess agreement between initial and second-opinion interpretations. The differences between the initial and second-opinion interpretations were examined using McNemar test or Bowker’s test of symmetry. Results: Disagreement on recurrence between the initial report and the second-opinion interpretation was observed in 32% of cases (22/69; k = 0.44). Second-opinion interpretations had a higher sensitivity and a higher specificity on recurrence compared to the initial interpretations (0.93 vs. 0.75 and 0.90 vs. 0.68, respectively), and the difference in specificity was significant (p = 0.016). Additional imaging studies were recommended more frequently in the initial interpretation (22% vs. 6%, p = 0.006). Conclusions: Our study shows the second-opinion interpretation by subspecialized radiologists improves the detection of pancreatic cancer recurrence after surgical resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-energy CT in the obese: a preliminary retrospective review to evaluate quality and feasibility of the single-source dual-detector implementation

Purpose: To determine the feasibility of performing dual-energy CT with a single-source spectral detector system in obese patients. Materials and methods: Retrospective, IRB-approved review of 28 patients weighing ≥ 270 lbs (122 kg) who underwent CT of the abdomen on a single-source spectral detector system was performed. Two blinded, independent radiologists rated relative preference between conventional CT images taken at 120 kVp (CCT120) and monoenergetic 70 keV equivalent (MonoE70) as well as iodine map image quality in the spleen, pancreas, kidneys, and liver. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between conventional CT and MonoE70 images and correlated with body habitus markers of weight, height, and abdominal diameter. Results: MonoE70 images were preferred by radiologists 100% of the time (1-sample t test, p < 0.0001) over conventional CCT120 images. Noise was significantly lower; SNR and CNR were significantly higher in MonoE70 images than in CCT120 images (paired t tests, p < 0.0001). Mean iodine map rating (scale 1–5) was 4.54 ± 0.58, denoting near homogenous and complete iodine mapping through the spleen, pancreas, kidneys, and liver for the majority of patients. Body habitus markers were not significantly correlated with image preference score; noise; MonoE70 SNR; MonoE70 CNR; change in noise, SNR, or CNR from CCT120 to MonoE70, or iodine map quality; ordinal and linear regression, p = 0.2547, p = 0.6837, p = 0.1888, p = 0.5489, p = 0.9830, p = 0.8849, p = 0.8741, p = 0.1522, respectively. Conclusion: The single-source spectral detector implementation of dual-energy CT provides viable, high-quality imaging for obese patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic accuracy of MRI with extracellular vs. hepatobiliary contrast material for detection of residual hepatocellular carcinoma after locoregional treatment

Purpose: To compare the diagnostic accuracy of extracellular gadolinium-based contrast-enhanced MRI (Gd-MRI) and gadoxetic acid-enhanced MRI (EOB-MRI) for the assessment of hepatocellular carcinoma (HCC) response to locoregional therapy (LRT) using explant correlation as the reference standard. Methods: Forty-nine subjects with cirrhosis and HCC treated with LRT who underwent liver MRI using either Gd-MRI (n = 26) or EOB-MRI (n = 23) within 90 days of liver transplantation were included. Four radiologists reviewed the MR images blinded to histology to determine the size and percentage of viable residual HCC using a per-lesion explant reference standard. Sensitivities, specificities, accuracies, and agreement with histology for the detection residual HCC were calculated. Results: Gd-MRI had greater agreement with histology (ICC: 0.98 [0.95–0.99] vs. 0.80 [0.63–0.90]) and greater sensitivity for viable HCC (76% [13/17 50–93%] vs. 58% [7/12; 28–85%]) than EOB-MRI; specificities were similar (84% [16/19; 60–97%] vs. 85% [23/27; 66–96%]). Areas under ROC curves for detecting residual viable tumor were 0.80 (0.64–0.92) for Gd-MRI and 0.72 (0.55–0.85) for EOB-MRI. Gd-MRI had greater inter-rater agreement than EOB-MRI for determining the size of residual viable HCC (ICC: 0.96 [0.92–0.98] vs. 0.85 [0.72–0.92]). Conclusion: Gd-MRI may be more accurate and precise than EOB-MRI for the assessment of viable HCC following LRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The role of contrast-enhanced computed tomography to detect renal stones

Purpose: To investigate the detectability of renal stones in corticomedullary and nephrographic phases on contrast-enhanced computed tomography (CT). Methods: All consecutive patients between January 2012 and February 2016 undergoing CT of the kidneys according to our department’s standard four-phase protocol and having at least one stone in the NC-phase (NCP) were included. Fifty patients with altogether 136 stones were eligible. Two radiologists in consensus evaluated the NCP from each examination and documented the number, location, and size of stones. Three abdominal radiologists blinded to the findings of the NCP reviewed independently the corticomedullary and nephrographic phases on two different occasions. They reported the number and location of stones in each kidney. For the inter-observer agreement the intra-class correlation coefficient (ICC) was estimated. The detection rate of renal stones was calculated for the three radiologists and compared between the two contrast-enhanced phases and the results were analyzed with concern to the size of the stones. Results: The ICC was 0.86. There was no statistically significant difference between corticomedullary and nephrographic phases (p = 0.94). The detection rate for stones measuring 3–5 mm was 82–88% and 98% for stones ≥ 6 mm. Conclusion: The detectability of renal stones ≥ 6 mm on contrast-enhanced CT is extremely high. This means that stones with a higher risk of not passing spontaneously can be safely diagnosed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corpus luteum with ovarian stromal edema is associated with pelvic pain and confusion for ovarian torsion

Purpose: To distinguish the corpus luteum with adjacent ovarian stromal edema as an entity associated with pelvic pain, with confounding ultrasound features that may lead to false-positive diagnosis of ovarian torsion. Methods: This is a blinded, retrospective study of 243 corpora lutea on transvaginal ultrasound. Imaging parameters included ovarian and corpus luteum volumes, central cystic space within the corpus luteum, vascularity around the corpus luteum, peripherally displaced follicles, and complex free fluid. Residual volume (ovarian volume minus corpus luteum volume) was used as a surrogate for ovarian stromal edema. Clinical parameters included age, pregnancy, and location/acuity of pain if present. Concern for ovarian torsion in radiology reports was documented. Results: 51.0% (124/243) of patients presented with pain. Multivariate regression analysis of factors significantly associated with pain (including age, p = 0.001; larger corpus luteum volume, p = 0.002; larger residual volume, p < 0.001; complex free fluid, p = 0.002; and peripherally displaced follicles, p < 0.001) left only increased residual volume as significantly associated with pain [OR 1.02–1.16; p = 0.01]. False-positive concern for ovarian torsion on ultrasound was present in 12.9% (16/124) of patients with pain, associated with enlarged ovaries (p < 0.001) and peripherally displaced follicles (p < 0.001). High correlation between location of pain and side of the corpus luteum was demonstrated in patients with pain < 14 days duration (p < 0.001). Conclusion: Corpus luteum with ovarian stromal edema is associated with pelvic pain and can mimic ovarian torsion on ultrasound. Further research should explore diagnostically useful differences between cases of ovarian torsion and cases of ovarian edema related to corpora lutea.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigating the role of DCE-MRI, over T2 and DWI, in accurate PI-RADS v2 assessment of clinically significant peripheral zone prostate lesions as defined at radical prostatectomy

Purpose: PI-RADS v2 dictates that dynamic contrast-enhanced (DCE) imaging be used to further classify peripheral zone (PZ) cases that receive a diffusion-weighted imaging equivocal score of three (DWI3), a positive DCE resulting in an increase in overall assessment score to a four, indicative of clinically significant prostate cancer (csPCa). However, the accuracy of DCE in predicting csPCa in DWI3 PZ cases is unknown. This study sought to determine the frequency with which DCE changes the PI-RADS v2 DWI3 assessment category, and to determine the overall accuracy of DCE-MRI in equivocal PZ DWI3 lesions. Materials and Methods: This is a retrospective study of patients with pathologically proven PCa who underwent prostate mpMRI at 3T and subsequent radical prostatectomy. PI-RADS v2 assessment categories were determined by a radiologist, aware of a diagnosis of PCa, but blinded to final pathology. csPCa was defined as a Gleason score ≥ 7 or extra prostatic extension at pathology review. Performance characteristics and diagnostic accuracy of DCE in assigning a csPCa assessment in PZ lesions were calculated. Results: A total of 271 men with mean age of 59 ± 6 years mean PSA 6.7 ng/mL were included. csPCa was found in 212/271 (78.2%) cases at pathology, 209 of which were localized in the PZ. DCE was necessary to further classify (45/209) of patients who received a score of DWI3. DCE was positive in 29/45 cases, increasing the final PI-RADS v2 assessment category to a category 4, with 16/45 having a negative DCE. When compared with final pathology, DCE was correct in increasing the assessment category in 68.9% ± 7% (31/45) of DWI3 cases. Conclusion: DCE increases the accuracy of detection of csPCa in the majority of PZ lesions that receive an equivocal PI-RADS v2 assessment category using DWI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardized report template for indeterminate renal masses at CT and MRI: a collaborative product of the SAR Disease-Focused Panel on Renal Cell Carcinoma

Purpose: To create a succinct yet comprehensive evidence-based structured report template for indeterminate renal masses characterized at CT and MRI. Methods: This IRB-exempt, iterative, multi-institutional quality improvement project was informed by published data derived from a multi-institutional survey and a multi-institutional review of CT and MRI radiology reports. A two-stage blinded Delphi process by the 16-member 12-institution Society of Abdominal Radiology Disease-Focused Panel on Renal Cell Carcinoma was conducted to create a structured report template for indeterminate renal masses evaluated at CT and MRI. Individual reporting characteristics were scored by members as ‘core,’ ‘optional,’ or ‘exclude.’ Threshold for inclusion was ≥ 80% support. If < 80% members considered a characteristic a ‘core’ feature, but ≥ 80% considered it either ‘core’ or ‘optional,’ it was considered an ‘optional’ feature. If neither was the case, the characteristic was excluded. Free-text comments were permitted. Characteristics considered ‘core’ by 50–99% of respondents in Round 1 (i.e., nonunanimous support) and uninvestigated free-text comments were assessed in Round 2. Core and optional structured reporting templates were derived. Results: The response rate was 100% in Round 1 (16/16) and Round 2 (16/16). In Round 1, 5 characteristics had unanimous support as ‘core’ features. Following Round 2, 13 characteristics had ≥ 80% support as ‘core’ features, and 10 characteristics had ≥ 80% support as ‘optional’ features. Structured report templates were derived. Discussion: Structured ‘core’ and ‘optional’ templates for indeterminate renal masses at CT and MRI were derived, which may improve compliance with reporting preferred and essential imaging characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗