Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomically precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Development of Metallic Magnetic Calorimeters for High Precision Measurements of Calorimetric Re-187 and Ho-163 Spectra

The measurement of calorimetric spectra following atomic weak decays, beta (b) and electron capture (EC), of nuclides having a very low Q-value, can provide an impressively high sensitivity to a non-vanishing neutrino mass. The achievable sensitivity in this kind of experiments is directly connected to the performance of the used detectors. In particular an energy resolution of a few eV and a pulse formation time well below 1 microsecond are required. Low temperature Metallic Magnetic Calorimeters (MMCs) for soft X-rays have already shown an energy resolution of 2.0 eV FWHM and a pulse rise-time of about 90 ns for fully micro-fabricated detectors. We present the use of MMCs for high precision measurements of calorimetric spectra following the beta-decay of Re-187 and the EC of Ho-163. We show results obtained with detectors optimized for Re-187 and for Ho-163 experiments respectively. While the detectors equipped with superconducting Re absorbers have not yet reached the aimed performance, a first detector prototype with a Au absorber having implanted Ho-163 ions already shows excellent results. An energy resolution of 12 eV FWHM and a rise time of 90 ns were measured.

Ranitzsch, P. C.-O.↗

Progress towards a space-borne quantum gravity gradiometer

Quantum interferometer gravity gradiometer for 3D mapping is a project for developing the technology of atom interferometer-based gravity sensor in space. The atom interferometer utilizes atomic particles as free fall test masses to measure inertial forces with unprecedented sensitivity and precision. It also allows measurements of the gravity gradient tensor components for 3D mapping of subsurface mass distribution. The overall approach is based on recent advances of laser cooling and manipulation of atoms in atomic and optical physics. Atom interferometers have been demonstrated in research laboratories for gravity and gravity gradient measurements. In this approach, atoms are first laser cooled to micro-kelvin temperatures. Then they are allowed to freefall in vacuum as true drag-free test masses. During the free fall, a sequence of laser pulses is used to split and recombine the atom waves to realize the interferometric measurements. We have demonstrated atom interferometer operation in the Phase I period, and we are implementing the second generation for a complete gradiometer demonstration unit in the laboratory. Along with this development, we are developing technologies at component levels that will be more suited for realization of a space instrument. We will present an update of these developments and discuss the future directions of the quantum gravity gradiometer project.

laser cooling↗

A highly efficient atomically thin curved PdIr bimetallene electrocatalyst

Abstract The multi-metallene with an ultrahigh surface area has great potential in precise tuning of surface heterogeneous d-electronic correlation by surface strain effect for the distinctive surface electronic structure, which is a brand new class of promising 2D electrocatalyst for sustainable energy device application. However, achieving such an atomically thin multi-metallene still presents a great challenge. Herein, we present a new synthetic method for an atomic-level palladium-iridium (PdIr) bimetallene with an average thickness of only ∼1.0 nm for achieving superior catalysis in the hydrogen evolution reaction (HER) and the formic acid oxidation reaction (FAOR). The curved PdIr bimetallene presents a top-ranked high electrochemical active area of 127.5 ± 10.8 m2 gPd+Ir−1 in the reported noble alloy materials, and exhibits a very low overpotential, ultrahigh activity and improved stability for HER and FAOR. DFT calculation reveals that the PdIr bimetallene herein has a unique lattice tangential strain, which can induce surface distortion while concurrently creating a variety of concave-convex featured micro-active regions formed by variously coordinated Pd sites agglomeration. Such a strong strain effect correlates the abnormal on-site active 4d10-t2g-orbital Coulomb correlation potential and directly elevates orbital-electronegativity exposure within these active regions, resulting in a preeminent barrier-free energetic path for significant enhancement of FAOR and HER catalytic performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Concentric Ring Gas Atomization Die Design for Optimized Particle Production

In partnership with Linde plc (formerly Praxair, Inc.), Ames Laboratory will further develop and commercialize its concentric-ring high pressure gas atomization (CR-HPGA) gas-die technology with a goal to improve the precision of metal powder production in a desired size range and quality. The successful commercialization of this technology could reduce production cost of metal powders and improve reliability of this industrial process, increasing specialty alloy powder availability for new applications and adoption into additive manufacturing and multiple materials sectors. The project scope is to [1] utilize AMES compressible gas flow and melt break-up models to explore a wide swath of parameter space available for the CR-HPGA technology, identifying the most promising gas-die designs for fabrication, [2] verify and optimize the new gas-die design, fabricate it and select preferred operating parameters by gas-only flow imaging and aspiration pressure measurements, down-selecting gas compositions and atomization parameters for full scale testing, [3] perform pilot-scale atomization trials with Al and/or Cu alloys of a new CR-HPGA gas-die at selected parameters, [4] evaluate gas-die performance by comparing resulting powder size distribution and powder quality attributes with equivalent powders made by conventional close-coupled HPGA technology, and [5] assess (through Praxair partnership) reduction in operational costs of new CR-HPGA gas-die through the use of an inert gas recovery/recycling system. In partnership with Praxair, Inc., the team, led by Ames Laboratory senior metallurgist Iver Anderson, intend to demonstrate the performance of an optimized CR-HPGA gas-die design in a pilot scale atomizer and better understand the design and operational controls to increase overall benefits for precision metal powder production.

42 ENGINEERING↗

Bayesian averaging for ground state masses of atomic nuclei in a Machine Learning approach

We present global predictions of the ground state mass of atomic nuclei based on a novel Machine Learning algorithm. We combine precision nuclear experimental measurements together with theoretical predictions of unmeasured nuclei. This hybrid data set is used to train a probabilistic neural network. In addition to training on this data, a physics-based loss function is employed to help refine the solutions. The resultant Bayesian averaged predictions have excellent performance compared to the testing set and come with well-quantified uncertainties which are critical for contemporary scientific applications. We assess extrapolations of the model’s predictions and estimate the growth of uncertainties in the region far from measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Picometer sensitivity metrology for EUV absorber phase

With growing interest in EUV attenuated phase-shift masks due to their superior image quality for applications such as dense contact and pillar arrays, it is becoming critical to model, measure, and monitor the intensity and relative phase of multilayer and absorber reflections. We present a solution based on physical modeling of reflectometry data, which can achieve single picometer phase precision and sensitivity to changes in average film thickness below one atomic monolayer. We measure absorber and multilayer reflectivity to determine thin-film parameters with a multidimensional optimization and then acquire a new measurement of either multilayer or absorber to determine perturbations in surface contamination thickness. While it is difficult to assess the accuracy of the first step, the simplicity of the second step allows us to characterize our sensitivity to changes in contamination thickness. Thus, we apply this analysis using an initial set of measurements and repeated measurements after a period of storage. For the multilayer, the total contamination growth was 1068 pm, which occurred almost exclusively during storage (1085 pm) and decreased very slightly during repeated measurements (-17 pm). For the absorber, the behavior was quite different, with a total growth of 126 pm, which occurred much less during storage (28 pm) and primarily during repeated measurements (98 pm). Ultimately, the change in relative phase (absorber minus multilayer) was -0.86 deg for the multilayer and -1.12 deg for the absorber. We estimate the precision of the surface contamination measurement to be 3σ < 6 pm for measuring thickness and 3σ < 0.2 deg for measuring phase.

36 MATERIALS SCIENCE↗

Surface Zeta Potential of ALD-Grown Metal-Oxide Films

Membranes are among the most promising technologies for energy-efficient and highly selective separations, and the surface-charge property of membranes plays a critical role in their broad applications. Atomic layer deposition (ALD) can deposit materials uniformly and with high precision and controllability on arbitrarily complex and large substrates, which renders it a promising method to tune the electrostatics of water/solid interfaces. However, a systematic study of surface-charge properties of ALD-grown films in aqueous environments is still lacking. In this work, 17 ALD-grown metal-oxide films are synthesized, and a comprehensive study of their water stability, wetting properties, and surface-charge properties is provided. Furthermore, this work represents a resource guide for researchers and ultimately for materials and process engineers, seeking to tailor interfacial charge properties of membranes and other porous water treatment components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum networks with neutral atom processing nodes

Abstract Quantum networks providing shared entanglement over a mesh of quantum nodes will revolutionize the field of quantum information science by offering novel applications in quantum computation, enhanced precision in networks of sensors and clocks, and efficient quantum communication over large distances. Recent experimental progress with individual neutral atoms demonstrates a high potential for implementing the crucial components of such networks. We highlight latest developments and near-term prospects on how arrays of individually controlled neutral atoms are suited for both efficient remote entanglement generation and large-scale quantum information processing, thereby providing the necessary features for sharing high-fidelity and error-corrected multi-qubit entangled states between the nodes. We describe both the functionality requirements and several examples for advanced, large-scale quantum networks composed of neutral atom processing nodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic Self-Locking of an OEO Containing a VCSEL

A method of dynamic self-locking has been demonstrated to be effective as a means of stabilizing the wavelength of light emitted by a vertical-cavity surface-emitting laser (VCSEL) that is an active element in the frequency-control loop of an optoelectronic oscillator (OEO) designed to implement an atomic clock based on an electromagnetically- induced-transparency (EIT) resonance. This scheme can be considered an alternative to the one described in Optical Injection Locking of a VCSEL in an OEO (NPO-43454), NASA Tech Briefs, Vol. 33, No. 7 (July 2009), page 33. Both schemes are expected to enable the development of small, low-power, high-stability atomic clocks that would be suitable for use in applications involving precise navigation and/or communication. To recapitulate from the cited prior article: In one essential aspect of operation of an OEO of the type described above, a microwave modulation signal is coupled into the VCSEL. Heretofore, it has been well known that the wavelength of light emitted by a VCSEL depends on its temperature and drive current, necessitating thorough stabilization of these operational parameters. Recently, it was discovered that the wavelength also depends on the microwave power coupled into the VCSEL. This concludes the background information. From the perspective that led to the conception of the optical injection-locking scheme described in the cited prior article, the variation of the VCSEL wavelength with the microwave power circulating in the frequency-control loop is regarded as a disadvantage and optical injection locking is a solution of the problem of stabilizing the wavelength in the presence of uncontrolled fluctuations in the microwave power. The present scheme for dynamic self-locking emerges from a different perspective, in which the dependence of VCSEL wavelength on microwave power is regarded as an advantageous phenomenon that can be exploited as a means of controlling the wavelength. The figure schematically depicts an atomic-clock OEO of the type in question, wherein (1) the light from the VCSEL is used to excite an EIT resonance in selected atoms in a gas cell (e.g., 87Rb atoms in a low-pressure mixture of Ar and Ne) and (2) the power supplied to the VCSEL is modulated by a microwave signal that includes components at beat frequencies among the VCSEL wavelength and modulation sidebands. As the VCSEL wavelength changes, it moves closer to or farther from a nearby absorption spectral line, and the optical power transmitted through the cell (and thus the loop gain) changes accordingly. A change in the loop gain causes a change in the microwave power and, thus, in the VCSEL wavelength. It is possible to choose a set of design and operational parameters (most importantly, the electronic part of the loop gain) such that the OEO stabilizes itself in the sense that an increase in circulating microwave power causes the VCSEL wavelength to change in a direction that results in an increase in optical absorption and thus a decrease in circulating microwave power. Typically, such an appropriate choice of operational parameters involves setting the nominal VCSEL wavelength to a point on the shorter-wavelength wing of an absorption spectral line.

Strekalov, Dmitry↗

Atomic Ordering-Induced Ensemble Variation in Alloys Governs Electrocatalyst On/Off States

The catalytic behavior of a material is influenced by ensembles—the geometric configuration of atoms. Traditional approaches, mainly utilizing solid-solution alloys in electrocatalysis, have often overlooked the challenges posed by concurrent changes in the electronic structure (i.e. d-band center) when the composition is altered. Here, this study introduces a methodology that distinctly separates the geometric effects (i.e. ensembles) from the electronic structure. We compare the reactivity of compositionally identical, but structurally different Pd 3 Bi ordered intermetallic and solid-solution alloys. Remarkably, we find that Pd 3 Bi intermetallics display nearly no reactivity for the methanol oxidation (MOR), while their solid-solution counterparts have significant reactivity. This highlights a unique case where materials with identical chemical compositions demonstrate drastically different catalytic behavior underscoring the critical importance of ensembles in electrocatalysis. Specifically, Pd 3 Bi intermetallics form smaller ensembles (average coordination number: 4.5 ± 1.6) with almost no measurable MOR activity at room temperature, in contrast to the solid-solution Pd 3 Bi that exhibit larger ensembles (average coordination number: 6.8 ± 0.9) and considerable MOR reactivity (0.5 mA cm −2 Pd ). An ordered Pd 3 Bi alloy, with an intermediate ensemble size (average coordination number: 5.3 ± 1.2), displays moderate MOR activity (0.1 mA cm −2 Pd ), further confirming the direct correlation between ensemble size and catalytic activity. Notably, all Pd 3 Bi alloys maintain similar electronic structures, because the chemical composition of the alloys is fixed, indicating that the differences in reactivity are predominantly from changes to the ensemble size. Our findings offer an approach for precisely controlling catalytic activity through manipulating the geometric configuration of the atoms within an alloy, paving the way for more efficient catalyst design.

alloys↗

FPGA-Based Networked Phasemeter for a Heterodyne Interferometer

A document discusses a component of a laser metrology system designed to measure displacements along the line of sight with precision on the order of a tenth the diameter of an atom. This component, the phasemeter, measures the relative phase of two electrical signals and transfers that information to a computer. Because the metrology system measures the differences between two optical paths, the phasemeter has two inputs, called measure and reference. The reference signal is nominally a perfect square wave with a 50- percent duty cycle (though only rising edges are used). As the metrology system detects motion, the difference between the reference and measure signal phases is proportional to the displacement of the motion. The phasemeter, therefore, counts the elapsed time between rising edges in the two signals, and converts the time into an estimate of phase delay. The hardware consists of a circuit board that plugs into a COTS (commercial, off-the- shelf) Spartan-III FPGA (field-programmable gate array) evaluation board. It has two BNC inputs, (reference and measure), a CMOS logic chip to buffer the inputs, and an Ethernet jack for transmitting reduced-data to a PC. Two extra BNC connectors can be attached for future expandability, such as external synchronization. Each phasemeter handles one metrology channel. A bank of six phasemeters (and two zero-crossing detector cards) with an Ethernet switch can monitor the rigid body motion of an object. This device is smaller and cheaper than existing zero-crossing phasemeters. Also, because it uses Ethernet for communication with a computer, instead of a VME bridge, it is much easier to use. The phasemeter is a key part of the Precision Deployable Apertures and Structures strategic R&D effort to design large, deployable, segmented space telescopes.

Rao, Shanti↗

Precision of ENDF and ENDL Formatted Data Files

The purpose is to ensure that today’s processing codes produced output to meet today’s accuracy needs. Since 1958 ENDL and about 1965 ENDF have each used a text format to define nuclear and atomic data in 11 columns for each data field. When these formats originated this was judged to be adequate to reproduce the accuracy of data at the time and to meet the needs of our applications. When these formats originated the dominant computer language of the day was FORTRAN and if written using an E11.4 format it would include only 4 or 5 digits of precision, e.g., 0.1234E-03 or 1.2345E-02, varying from one computer/system to another the result was not even unique. In the case of ENDF the 4 digit precision was not even adequate to uniquely define the atomic weight of the target, e.g., U238 = 92238 = 0.9224E+5 = WRONG! From its inceptions the ENDF format had a precision problem. One of my first tasks when in 1967 fresh out of graduate school I joined what later became the National Nuclear Data Center (NNDC), was to address this precision problem. By working with ENDF producers and users throughout the U.S. we verified, 1) E or D is not required to define FORTRAN readable numbers, e.g., E+4 or +4 are both o.k. 2) With ENDF energy eV and cross section in barns, 2 digit exponents are almost never required. 3) Since energy is never negative we could use the first of the 11 columns for a digit. Knowing this allowed us to produce ENDF/B-II to 6 or 7 digit precision, e.g., blank, decimal point, 2 or 3 digit exponent, e.g., ^1.23456-12 or ^1.234567-3. Below is an example of the actual ENDF/B-II data released. Note, the date 1970 and the atomic weight, ZA, uniquely defined to 6-digit accuracy, ^9.22350+ 4.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advancing Photo(Electro)Chemical Water Splitting: The Promise of Atomically Dispersed Single‐, Dual‐, and Alloy‐Site Catalysts

Single-atom catalysts (SACs) have rapidly gained prominence as an emerging class of electrocatalysts for water splitting, owing to their uniform and precisely defined active sites. By maintaining uniform reaction pathways, SACs minimize the formation of unwanted byproducts, thus exhibiting extremely high selectivity and atomic efficiency. A key determinant of SAC performance lies in the interfacial interaction between the isolated metal atoms and the supporting material under strong metal–support coordination, which is vital for maintaining long-term activity. However, despite these benefits, reproducibly synthesizing SACs with high metal loadings while retaining uniform dispersion remains a significant challenge. To address the intrinsic challenges of SACs, recent research has expanded into dual-atom catalysts (DACs) and single-atom alloy catalysts (SAACs), providing synergistic active sites and combining the benefits of SACs with bimetallic systems. Furthermore, this review systematically explores the latest advancements in synthesis methods and innovations for SACs for electrochemical water splitting. Additionally, it examines the evolution of catalyst design, emphasizing the unique structural and electronic characteristics of single-site, dual-site, and alloyed SAC systems and highlighting their critical roles in accelerating water-splitting reaction kinetics as well as the prevailing challenges and outlining promising directions for advancing hydrogen production via water electrolysis.

08 HYDROGEN↗

Correlating the three-dimensional atomic defects and electronic properties of two-dimensional transition metal dichalcogenides

The electronic, optical and chemical properties of two-dimensional transition metal dichalcogenides strongly depend on their three-dimensional atomic structure and crystal defects. Using Re-doped MoS 2 as a model system, here we present scanning atomic electron tomography as a method to determine three-dimensional atomic positions as well as positions of crystal defects such as dopants, vacancies and ripples with a precision down to 4 pm. We further measure the three-dimensional bond distortion and local strain tensor induced by single dopants. By directly offering these experimental three-dimensional atomic coordinates to density functional theory, we obtain more accurate electronic band structures than derived from conventional density functional theory calculations that relies on relaxed three-dimensional atomic coordinates. We anticipate that scanning atomic electron tomography not only will be generally applicable to determine the three-dimensional atomic coordinates of two-dimensional materials, but also will enable ab initio calculations to better predict the physical, chemical and electronic properties of these materials.

36 MATERIALS SCIENCE↗

Vapor Phase Installation of CpCo(CO) 2 in MOF‐808

Metal-organic frameworks (MOFs), including MOF-808 present an opportunity for vapor phase installation of reactive centers that may serve as uniform sites for precision catalysis. The mechanism of cobalt installation in MOF-808 through atomic layer deposition (ALD) upon CpCo(CO )2 exposure is investigated through in situ FTIR spectroscopy complemented by density functional theory modeling. The role of subsequent H 2 O exposure in the hydrolysis of carbonyl and cyclopentadienyl ligands to complete the installation is also investigated. In situ FTIR study reveals that upon exposure of CpCo(CO) 2 to MOF-808 at 115 °C, a long-lived, stable intermediate is formed that presents carbonyl stretching vibrations similar to the undissociated precursor that are attributed to multiple chemisorbed carbonyl complexes. In MOF-808, cobalt species are initially absorbed near the BTC linker rather than directly on the nodes, revealing the importance of non-covalent interactions in the installation process. DFT suggests that H 2 O exposure promotes carbonyl elimination but leaves a cyclopentadienyl-capped cobalt that is more stable than the complete hydrolysis product. The simulations are consistent with cobalt installation in MOF-808 using CpCo(CO) 2 and H 2 O at 115 °C and further consistent with the lack of ALD thin film deposition of cobalt oxide thin films on planar supports.

36 MATERIALS SCIENCE↗

Franck-Condon Tuning of Optical Cycling Centers by Organic Functionalization

Laser induced electronic excitations that spontaneously emit photons and decay directly to the initial ground state (“optical cycling transitions”) are used in quantum information and precision measurement for state initialization and readout. To extend this primarily atomic technique to large, organic compounds, we theoretically investigate optical cycling of alkaline earth phenoxides and their functionalized derivatives. We find that optical cycle leakage due to wave function mismatch is low in these species, and can be further suppressed by using chemical substitution to boost the electron-withdrawing strength of the aromatic molecular ligand through resonance and induction effects. This provides a straightforward way to use chemical functional groups to construct optical cycling moieties for laser cooling, state preparation, and quantum measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

36 Hz integral linewidth laser based on a photonic integrated 4.0 m coil resonator

Laser stabilization sits at the heart of many precision scientific experiments and applications, including quantum information science, metrology, and atomic timekeeping. Many of these systems narrow the laser linewidth and stabilize the carrier by use of Pound–Drever–Hall (PDH) locking to a table-scale, ultrahigh quality factor (Q), vacuum spaced Fabry–Perot reference cavity. Integrating these cavities to bring characteristics of PDH stabilization to the chip scale is critical to reducing their size, cost, and weight, and enabling a wide range of portable and system-on-chip applications. We report a significant advance in integrated laser linewidth narrowing, stabilization, and noise reduction by use of a photonic integrated 4.0 m long coil resonator to stabilize a semiconductor laser. We achieve a 36 Hz 1 / π <#comment/> -integral linewidth, Allan deviation of 1.8 × <#comment/> 10 − <#comment/> 13 at 10 ms measurement time, and a 2.3 kHz/s drift—to the best of our knowledge, the lowest integral linewidth and highest stability demonstrated for an integrated waveguide reference cavity. This performance represents over an order of magnitude improvement in integral linewidth and frequency noise over previous integrated waveguide PDH stabilized reference cavities and bulk-optic and integrated injection locked approaches, and over two orders of magnitude improvement in frequency and phase noise than integrated injection locked approaches. Two different wavelength coil designs are demonstrated, stabilizing lasers at 1550 nm and 1319 nm. The resonator is bus-coupled to a 4.0 m long coil, with a 49 MHz free spectral range, mode volume of 1.0 × <#comment/> 10 10 µ <#comment/> m 3 , and 142 million intrinsic Q , fabricated in a CMOS compatible, ultralow loss silicon nitride waveguide platform. Our measurements and simulations show that the thermorefractive noise floor for this particular cavity is reached for frequencies down to 20 Hz in an ambient environment with simple passive vibration isolation and without vacuum or thermal isolation. The thermorefractive noise limited performance is estimated to yield an 8 Hz 1 / π <#comment/> -integral linewidth and Allan deviation of 5 × <#comment/> 10 − <#comment/> 14 at 10 ms, opening a stability regime that heretofore has been available only in fundamentally non-integrated systems. These results demonstrate the potential to bring the characteristics of laboratory-scale stabilized lasers to the integrated, wafer-scale compatible chip scale, and are of interest for a number of applications in quantum technologies and atomic, molecular, and optical physics, and with further developments below 10 Hz linewidth, can be highly relevant to ultralow noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗