Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical detection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Influence of Design Variations on Systems Performance

High-risk aerospace components have to meet very stringent quality, performance, and safety requirements. Any source of variation is a concern, as it may result in scrap or rework. poor performance, and potentially unsafe flying conditions. The sources of variation during product development, including design, manufacturing, and assembly, and during operation are shown. Sources of static and dynamic variation during development need to be detected accurately in order to prevent failure when the components are placed in operation. The Systems' Health and Safety (SHAS) research at the NASA Ames Research Center addresses the problem of detecting and evaluating the statistical variation in helicopter transmissions. In this work, we focus on the variations caused by design, manufacturing, and assembly of these components, prior to being placed in operation (DMV). In particular, we aim to understand and represent the failure and variation information, and their correlation to performance and safety and feed this information back into the development cycle at an early stage. The feedback of such critical information will assure the development of more reliable components with less rework and scrap. Variations during design and manufacturing are a common source of concern in the development and production of such components. Accounting for these variations, especially those that have the potential to affect performance, is accomplished in a variety ways, including Taguchi methods, FMEA, quality control, statistical process control, and variation risk management. In this work, we start with the assumption that any of these variations can be represented mathematically, and accounted for by using analytical tools incorporating these mathematical representations. In this paper, we concentrate on variations that are introduced during design. Variations introduced during manufacturing are investigated in parallel work.

Tumer, Irem Y.↗

Electric organ discharges and electric images during electrolocation

Weakly electric fish use active electrolocation - the generation and detection of electric currents - to explore their surroundings. Although electrosensory systems include some of the most extensively understood circuits in the vertebrate central nervous system, relatively little is known quantitatively about how fish electrolocate objects. We believe a prerequisite to understanding electrolocation and its underlying neural substrates is to quantify and visualize the peripheral electrosensory information measured by the electroreceptors. We have therefore focused on reconstructing both the electric organ discharges (EODs) and the electric images resulting from nearby objects and the fish's exploratory behaviors. Here, we review results from a combination of techniques, including field measurements, numerical and semi-analytical simulations, and video imaging of behaviors. EOD maps are presented and interpreted for six gymnotiform species. They reveal diverse electric field patterns that have significant implications for both the electrosensory and electromotor systems. Our simulations generated predictions of the electric images from nearby objects as well as sequences of electric images during exploratory behaviors. These methods are leading to the identification of image features and computational algorithms that could reliably encode electrosensory information and may help guide electrophysiological experiments exploring the neural basis of electrolocation.

Review, Tutorial↗

Conformational Panorama and Chirality Controlled Structure–Energy Relationship in a Chiral Carboxylic Acid Dimer

Chirality recognition in dimers of tetrahydro-2-furoic acid (THFA) was studied in a conformer-specific manner using rotational spectroscopy and theoretical approaches. THFA shows a strong preference for the trans- over the cis-COOH configuration. Two drastically different scenarios are possible for the detectable (THFA) 2 : a kinetically preferred dimer bound by feeble interactions between two trans-THFAs or a thermodynamically favored dimer with a double hydrogen-bonded ring structure between two cis subunits. To identify the conformers responsible for the extremely dense rotational spectra observed, it was essential not only to locate several hundred homo/heterochiral (THFA) 2 minima in ab initio calculations but also to evaluate the energetic connectivities among the minima. The study further reveals an interesting chirality dependent structure-energy ordering relationship. A method for enantiomeric excess (ee) determination of THFA is presented using a recently proposed chiral self-tag approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generation of random geological models using multi-randomization for machine learning

Generating high-fidelity geological models is essential for advancing machine learning (ML) methods in automated seismic interpretation. For instance, seismic images paired with corresponding fault labels are foundational for ML-based fault detection from seismic migration sections. While several open-access datasets of random geological models exist, open-source tools specifically designed to produce large volumes of such models for ML applications remain scarce. To address this gap, we present RGM (Random Geological Model), an open-source software package for efficiently generating 2D and 3D synthetic geological models tailored for ML workflows. RGM supports the creation of diverse model components, including medium property distributions (P-/S-wave velocities and density), seismic reflectivity images (i.e., synthetic migration sections), relative geological time, and discrete fault attributes such as probability, dip, strike, rake, and displacement. It also accommodates the creation of complex geological features such as salt bodies and unconformities. The model generation algorithm employs a multi-randomization strategy, yielding an effectively infinite-dimensional model space that encompasses a wide range of geological scenarios and associated seismic features. Furthermore, RGM incorporates a method to generate synthetic elastic migration images using analytical elastic reflection coefficients combined with frequency-dependent scaling. This functionality enables the creation of training datasets for ML models that leverage elastic seismic images. RGM is implemented in modern object-oriented Fortran, allowing users to flexibly control statistical parameters governing model variability. We demonstrate the capability, performance, and geological realism of the package through comprehensive 2D and 3D examples.

58 GEOSCIENCES↗

Detecting compounds in microfluidic droplets using mass spectrometry

Disclosed herein are devices and methods for detecting compounds in droplets using mass spectrometry. In some embodiments, the device comprises: a microfluidics-MS (microMS) device, wherein the microMS device comprises: a droplet-to-digital microfluidic device, wherein the droplet-to-digital microfluidic device comprises: a glass layer; an electrode layer comprising chrome electrodes etched onto one side of the glass layer; a dielectric layer configured for electrowetting; and a microfluidics layer comprising channels, pockets, and a droplet generator, for example a T-junction droplet generator, wherein the pockets are connected to the channels; and a mass spectrometry plate, wherein the mass spectrometry plate is reversibly sealed to the microfluidic device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved luminescence detection of peroxynitrite using a reactivity-based lanthanide probe

Peroxynitrite (ONOO - ) is a powerful and short-lived oxidant formed in vivo, which can react with most biomolecules directly. To fully understand the roles of ONOO - in cell biology, improved methods for the selective detection and real-time analysis of ONOO - are needed. We present a water-soluble, luminescent europium(III) probe for the rapid and sensitive detection of peroxynitrite in human serum, living cells and biological matrices. We have utilised the long luminescence lifetime of the probe to measure ONOO - in a time-resolved manner, effectively avoiding the influence of autofluorescence in biological samples. To demonstrate the utility of the Eu(III) probe, we monitored the production of ONOO - in different cell lines, following treatment with a cold atmospheric plasma device commonly used in the clinic for skin wound treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An innovative approach to the development of a portable unit for analytical flame characterization in a microgravity environment

The availability of manned laboratory facilities in space offers wonderful opportunities and challenges in microgravity combustion science and technology. In turn, the fundamentals of microgravity combustion science can be studied via spectroscopic characterization of free radicals generated in flames. The laser-induced fluorescence (LIF) technique is a noninvasive method of considerable utility in combustion physics and chemistry suitable for monitoring not only specific species and their kinetics, but it is also important for imaging of flames. This makes LIF one of the most important tools for microgravity combustion science. Flame characterization under microgravity conditions using LIF is expected to be more informative than other methods aimed at searching for effects like pumping phenomenon that can be modeled via ground level experiments. A primary goal of our work consisted in working out an innovative approach to devising an LIF-based analytical unit suitable for in-space flame characterization. It was decided to follow two approaches in tandem: (1) use the existing laboratory (non-portable) equipment and determine the optimal set of parameters for flames that can be used as analytical criteria for flame characterization under microgravity conditions; and (2) use state-of-the-art developments in laser technology and concentrate some effort in devising a layout for the portable analytical equipment. This paper presents an up-to-date summary of the results of our experiments aimed at the creation of the portable device for combustion studies in a microgravity environment, which is based on a portable UV tunable solid-state laser for excitation of free radicals normally present in flames in detectable amounts. A systematic approach has allowed us to make a convenient choice of species under investigation, as well as the proper tunable laser system, and also enabled us to carry out LIF experiments on free radicals using a solid-state laser tunable in the UV.

Dubinskiy, Mark A.↗

In-Situ Measurement of Hall Thruster Erosion Using a Fiber Optic Regression Probe

One potential life-limiting mechanism in a Hall thruster is the erosion of the ceramic material comprising the discharge channel. This is especially true for missions that require long thrusting periods and can be problematic for lifetime qualification, especially when attempting to qualify a thruster by analysis rather than a test lasting the full duration of the mission. In addition to lifetime, several analytical and numerical models include electrode erosion as a mechanism contributing to enhanced transport properties. However, there is still a great deal of dispute over the importance of erosion to transport in Hall thrusters. The capability to perform an in-situ measurement of discharge channel erosion is useful in addressing both the lifetime and transport concerns. An in-situ measurement would allow for real-time data regarding the erosion rates at different operating points, providing a quick method for empirically anchoring any analysis geared towards lifetime qualification. Erosion rate data over a thruster s operating envelope would also be useful in the modeling of the detailed physics inside the discharge chamber. There are many different sensors and techniques that have been employed to quantify discharge channel erosion in Hall thrusters. Snapshots of the wear pattern can be obtained at regular shutdown intervals using laser profilometry. Many non-intrusive techniques of varying complexity and sensitivity have been employed to detect the time-varying presence of erosion products in the thruster plume. These include the use quartz crystal microbalances, emission spectroscopy, laser induced flourescence, and cavity ring-down spectroscopy. While these techniques can provide a very accurate picture of the level of eroded material in the thruster plume, it is more difficult to use them to determine the location from which the material was eroded. Furthermore, none of the methods cited provide a true in-situ measure of erosion at the channel surface while the thruster is in operation (i.e. none yield a continuous channel erosion measurement). A recent fundamental sensor development effort has led to a novel regression, erosion, and ablation sensor technology (REAST). The REAST sensor allows for measurement of real-time surface erosion rates at a discrete surface location. The sensor was tested using a linear Hall thruster geometry (see Fig. 1), which served as a means of producing plasma erosion of a ceramic discharge chamber. The mass flow rate, discharge voltage, and applied magnetic field strength could be varied, allowing for erosion measurements over a broad thruster operating envelope. Results are presented demonstrating the ability of the REAST sensor to capture not only the insulator erosion rates but also changes in these rates as a function of the discharge parameters.

Polzin, Kurt↗

Sample Preparation Method for Low-Level Total 129 I Measurements by ICP-MS

Trace-level measurements of iodine’s isotopic ( 129 I and 127 I) and chemical species distributions are needed for an accurate understanding of radioiodine migration in the Hanford subsurface. Pacific Northwest National Laboratory (PNNL) previously developed a novel analytical method for iodine characterization that uses ion chromatography (IC) coupled to inductively coupled mass spectrometry (ICP-MS). While the method can measure speciated forms of 129 I at levels below the drinking water standard, an interference from molybdenum (Mo) prevents the assay from quantifying the $\underline{total}$ 129 I concentration in many Hanford sample matrices. In this work, solvent extraction was evaluated as a sample preparation method for eliminating the Mo interference. A series of 10 experiments was conducted in which solutions containing known amounts of iodate or iodide were treated by solvent extraction, and the extracted solutions were analyzed for total iodine concentrations by ICP MS. Several extraction parameters such as reagent concentrations and chemical reaction times were systematically adjusted in attempts to optimize the extraction process. While solvent extraction was shown to be effective at removing Mo, there was a consistent inability to recover more than approximately 75% of the total iodine in most experiments. This would reduce the ability to detect 129 I at levels near the drinking water standard. Additionally, the extraction efficiencies in several experiments were highly variable, suggesting that solvent extraction could add significant uncertainty to radioiodine measurements. We recommend evaluating ion exchange as an alternative sample preparation approach in fiscal year (FY) 2024.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

$t_1$-Noise eliminated dipolar heteronuclear multiple-quantum coherence solid-state NMR spectroscopy

Heteronuclear correlation (HETCOR) spectroscopy is one of the key tools in the arsenal of the solid-state NMR spectroscopist to probe chemical and spatial proximities between two different nuclei and enhance spectral resolution. Dipolar heteronuclear multiple-quantum coherence (D-HMQC) is a powerful technique that can be potentially utilized to obtain 1 H detected 2D HETCOR solid-state NMR spectra of any NMR active nucleus. A long-standing problem in 1 H detected D-HMQC solid-state NMR experiments is the presence of t 1 -noise which reduces sensitivity and impedes spectral interpretation. In this contribution, we describe novel pulse sequences, termed t 1 -noise eliminated (TONE) D-HMQC, that minimize t 1 -noise and can provide higher sensitivity and resolution than conventional D-HMQC. Monte-Carlo and numerical simulations confirm that t 1 -noise in conventional D-HMQC primarily occurs because random MAS frequency fluctuations cause variations in the NMR signal amplitude from scan to scan, leading to imperfect cancellation of uncorrelated signals by phase cycling. The TONE D-HMQC sequence uses 1 H π-pulses to refocus the evolution of 1 H CSA across each SR4 2 1 recoupling block, improving the stability of the pulse sequence to random MAS frequency fluctuations. The 1 H refocusing pulses also restore the orthogonality of in-phase and anti-phase magnetization for all crystallite orientations at the end of each recoupling block, enabling the use of 90° flip-back or LG spin-lock trim pulses to reduce the intensity of uncorrelated signals. We demonstrate the application of these methods to acquire 1 H detected 2D 1 H{ 35 Cl} and 1 H{ 13 C} HETCOR spectra of histidine·HCl·H 2 O with reduced t 1 -noise. To show generality, we also apply these methods to obtain 2D 1 H{ 17 O} spectra of 20%- 17 O fmoc-alanine and for the first time at natural abundance, 2D 1 H{ 25 Mg} HETCOR spectra of magnesium hydroxide. The TONE D-HMQC sequences are also used to probe 1 H– 25 Mg and 1 H– 27 Al proximities in Mg–Al layered double hydroxides and confirm the even mixing of Mg and Al in these materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the hydrolytic degradation of UF 4 in humid air

This manuscript describes the chemical transformations that occur during hydrolysis of uranium tetrafluoride (UF 4 ) due to its storage in humid air (85% and 50% relative humidity) at ambient temperatures. This hydrolysis was previously reported to proceed slowly or not at all (depending on the percent relative humidity); however, previous reports relied primarily on X-ray diffraction methods to probe uranium speciation. Here, we employ a battery of physiochemical probing techniques to explore potential hydrolysis, including Raman spectroscopy, powder X-ray diffraction, 19 F nuclear magnetic resonance spectroscopy, scanning electron microscopy, and focused ion beam microscopy with energy-dispersive X-ray spectroscopy. Of these, only Raman spectroscopy proved to be particularly useful at observing chemical changes to UF 4 . It was found that anhydrous UF 4 slightly oxidizes over the course of thirteen days to Schoepite-like uranium complexes and possibly UO 3 . In contrast, UF 4 exposed to 50% relative humidity slightly decomposes into UO 2 F 2 , Schoepite-like uranium complexes, and possibly a high order uranium oxide that eluded chemical assignment (U x O y ). Despite the rich chemical speciation observed in our Raman spectroscopy measurements, X-ray diffraction and 19 F NMR measurements on the same material showed no changes. Microscopy measurements suggest that the observed reactions between UF 4 and water occur primarily on the surface of UF 4 particulates via a method that is visually similar to surface corrosion of metals. Therefore, we postulate that NMR spectroscopy and X-ray diffraction, which are well-suited for bulk analysis, are less suited than Raman spectroscopy to observe the surface-based reactions that occur to UF 4 when exposed to humid air. Considering the importance of UF 4 in the production of nuclear fuel and weapons, the results presented herein are widely applicable to numerous nuclear science fields where uranium detection and speciation in humid environments is of value, including nuclear nonproliferation and nuclear forensics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Raman scattering to study reacting gas flow over a catalyst

l present a series of computational methods for analyzing and correcting Raman scattering from a reacting gas flow. My work focused on the laser diagnostic measurements of formaldehyde production over a silver catalyst, specifically the Raman spectroscopy component. This technique offers a non-intrusive, in situ way to measure the coupling between the gas phase and surface activity of a catalytic reaction at relevant industrial conditions. This report outlines the steps followed for correcting the non-idealities in the data due to both the detection optics and scattering mechanics. By implementing such refinement steps, l can generate an accurate 2D spatial map of the temperature profile, number densities for major species, and relative consumption of reactants throughout the reactor cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Phase Separation in Czochralski Grown Single Crystal Ilmenite

Ilmenite (FeTiOs) is a wide bandgap semiconductor with an energy gap of 2.58 eV. Ilmenite has properties suited for radiation tolerant applications, as well as a variety of other electronic applications. Single crystal ilmenite has been grown from the melt using the Czochralski method. Growth conditions have a profound effect on the microstructure of the samples. Here we present data from a variety of analytical techniques which indicate that some grown crystals exhibit distinct phase separation during growth. This phase separation is apparent for both post-growth annealed and unannealed samples. Under optical microscopy, there appear two distinct areas forming a matrix with an array of dots on order of 5 pm diameter. While appearing bright in the optical micrograph, atomic force microscope (AFM) shows the dots to be shallow pits on the surface. Magnetic force microscope (MFM) shows the dots to be magnetic. Phase identification via electron microprobe analysis (EMPA) indicates two major phases in the unannealed samples and four in the annealed samples, where the dots appear to be almost pure iron. This is consistent with micrographs taken with a scanning probe microscope used in the magnetic force mode. Samples that do not exhibit the phase separation have little or no discernible magnetic structure detectable by the MFM.

Wilkins, R.↗

Structural modification of fentanyls for their retrospective identification by gas chromatographic analysis using chloroformate chemistry

Abstract The one-step breakdown and derivatization of a panel of nine fentanyls to yield uniquely tagged products that can be detected by Electron Ionization Gas Chromatography-Mass Spectrometry (EI-GC-MS) is presented. The method involves the treatment of the synthetic opioids with 2,2,2-trichloroethoxycarbonyl chloride (TrocCl) at 60 °C for 3 h in dichloromethane and furnishes two products from one fentanyl molecule that can be used to retrospectively identify the original opioid. Parameters that were studied and fully optimized for the method included temperature, solvent, nature of scavenging base and reaction time. One of the two resulting products from the reaction bears the trichloroethoxycarbonyl (Troc) tag attached to the norfentanyl portion of the original opioid and greatly aids in the opioid detection and identification process. The methodology has been applied to the chemical modification of a panel of nine fentanyls and in all cases the molecular ion peak for the Troc-norfentanyl product bearing the distinctive trichloroethyl isotopic signature can be clearly observed. The method’s LLOD was determined to be 10 ng/mL while its LLOQ was found to be 20 ng/mL. This methodology represents the first application of chloroformates in the chemical modification of this class of synthetic opioids that are notoriously inert to common derivatization strategies available for GC–MS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly sensitive 2D X-ray absorption spectroscopy via physics informed machine learning

Abstract Improving the spatial and spectral resolution of 2D X-ray near-edge absorption structure (XANES) has been a decade-long pursuit to probe local chemical reactions at the nanoscale. However, the poor signal-to-noise ratio in the measured images poses significant challenges in quantitative analysis, especially when the element of interest is at a low concentration. In this work, we developed a post-imaging processing method using deep neural network to reliably improve the signal-to-noise ratio in the XANES images. The proposed neural network model could be trained to adapt to new datasets by incorporating the physical features inherent in the latent space of the XANES images and self-supervised to detect new features in the images and achieve self-consistency. Two examples are presented in this work to illustrate the model’s robustness in determining the valence states of Ni and Co in the LiNi x Mn y Co 1-x-y O 2 systems with high confidence.

36 MATERIALS SCIENCE↗

Trace Impurities Identified as Forensic Signatures in CMX-5 Fuel Pellets Using X-ray Spectroscopic Techniques

We report that small-particle analysis is a highly promising emerging forensic tool for analysis of interdicted special nuclear materials. Integration of microstructural, morphological, compositional, and molecular impurity signatures could provide significant advancements in forensic capabilities. We have applied rapid, high-sensitivity, hard X-ray synchrotron chemical imaging to analyze impurity signatures in two differently fabricated fuel pellets from the 5th Collaborative Materials Exercise (CMX5) of the IAEA Nuclear Forensics International Working Group. The spatial distributions, chemical compositions, and morphological and molecular characteristics of impurities were evaluated using X-ray absorption near-edge structure (XANES) and X-ray fluorescence chemical imaging to discover principal impurities, their granularity, particle sizes, modes of occurrence (distinct grains vs incorporation in the UO 2 lattice), and sources and mechanisms of incorporation. Differences in UO 2+x stoichiometry were detected at the microscale in nominally identical UO 2 ceramics (CMX5-A and CMX5-B), implying the presence of multiple UO 2 host phases with characteristic microstructures and feedstock compositions. Al, Fe, Ni, W, and Zr impurities and integrated impurity signature analysis identified distinctly different pellet synthesis and processing methods. For example, two different Al, W, and Zr populations in the CMX5-B sample indicated a more complex processing history than the CMX5-A sample. K-edge XANES measurements reveal both metallic and oxide forms of Fe and Ni but with different proportions between each sample. Altogether, these observations suggest multiple sources of impurities, including fabrication (e.g., force-sieving) and feedstock (mineral oxides). This study demonstrates the potential of synchrotron techniques to integrate different signatures across length scales (angstrom to micrometer) to detect and differentiate between contrasting UO 2 fuel fabrication techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Nitrate Ion Monitoring with Poly(3,4-ethylenedioxythiophene) (PEDOT) Materials

Nitrate (NO 3 ) pollution in groundwater, caused by various factors both natural and synthetic, contributes to the decline of human health and well-being. Current techniques used for nitrate detection include spectroscopic, electrochemical, chromatography, and capillary electrophoresis. It is highly desired to develop a simple cost-effective alternative to these complex methods for nitrate detection. Therefore, a real-time poly (3,4-ethylenedioxythiophene) (PEDOT)-based sensor for nitrate ion detection via electrical property change is introduced in this study. Vapor phase polymerization (VPP) is used to create a polymer thin film. Variations in specific parameters during the process are tested and compared to develop new insights into PEDOT sensitivity towards nitrate ions. Through this study, the optimal fabrication parameters that produce a sensor with the highest sensitivity toward nitrate ions are determined. With the optimized parameters, the electrical resistance response of the sensor to 1000 ppm nitrate solution is 41.79%. Furthermore, the sensors can detect nitrate ranging from 1 ppm to 1000 ppm. The proposed sensor demonstrates excellent potential to detect the overabundance of nitrate ions in aqueous solutions in real time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasmonic Terahertz Devices and Sensors Based on Carbon Electronics

Tunable terahertz (THz) photonic devices are imperative in a wide range of applications ranging from THz signal modulation to molecular sensing. One of the currently prevailing methods is based on arrays of metallic or dielectric resonators integrated with functional materials in response to an external stimulus, in which for the purpose of sensing the external stimuli may introduce inadvertent undesirable effects into the target samples to be measured. Here we developed an alternative approach by postprocessing nanothickness macro-assembled graphene (nMAG) films with widely tunable THz conductivity, enabling versatile solid-state THz devices and sensors, showing multifunctional nMAG-based applications. The THz conductivities of free-standing nMAGs showed a broad range from 1.2 x 10 3 S/m in reduced graphene oxide before annealing to 4.0 x 10 6 S/m in a nMAG film annealed at 2800 °C. We fabricated nMAG/dielectric/metal and nMAG/dielectric/nMAG THz Salisbury absorbers with broad reflectance ranging from 0% to 80%. The highly conductive nMAG films enabled THz metasurfaces for sensing applications. Taking advantage of the resonant field enhancement arising from the plasmonic metasurface structures and the strong interactions between analyte molecules and nMAG films, we have successfully detected diphenylamine with a limit of detection of 4.2 pg. Those wafer-scale nMAG films present promising potential in high-performance THz electronics, photonics, and sensors.

36 MATERIALS SCIENCE↗