Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Six-degree-of-freedom Sensor Fish design and instrumentation

Fish passing through dams may be injured or killed despite advances in turbine design, project operations and other fish bypass systems. The Six-degree-of-freedom (6DOF) Sensor Fish device is an autonomous sensor package designed to characterize the physical conditions and physical stresses fish are exposed to when they pass through complex hydraulic environments. It has been used to identify the locations and operations where conditions are severe enough to injure or kill fish. During the design process, a set of governing equations of motion for the device was derived and simulated in order to understand the design implications of instrument selection and placement within the body of the device. The sensor package includes three rotation sensors, three acceleration sensors, a pressure sensor, and a temperature sensor with a sampling frequency of 2,000 Hz. Its housing is constructed of clear polycarbonate plastic. It is 24.5 mm in diameter and 90 mm in length, weighs about 43 grams, similar to the size and density of a yearling salmon smolt. The relative errors of both the linear acceleration and angular velocity measurements were determined to be less than 5% from laboratory acceptance tests. Since its development in 2005, the 6DOF Sensor Fish device has been successfully deployed at many major dams in the United States.

13 HYDRO ENERGY↗

Tank 49H salt batch supernate qualification for ARP/MCU

This report covers the laboratory testing and analyses of Tank 49H Qualification Sample Sets A and C, performed in support of initial radioactive operations of Actinide Removal Process (ARP) and Modular Caustic-Side Solvent Extraction Unit (MCU). Major goals of this work include checking that Tank 49H was well mixed after the last receipt of Tank 23H, characterizing Tank 49H supernate after solids are settled so that its composition can be compared to waste acceptance and hazard criteria, verifying actinide and strontium adsorption with a small scale test using monosodium titanate (MST) and filtration, checking MCU solvent performance when applied to the liquid produced from MST contact, and verifying that in-tank settling after a minimum of 30 days was at least as good or better at reducing solids content after a Tank 49H to Tank 50H transfer occurred than what was observed in less time in the lab. The first four items were covered by Sample Set A. The fifth item was covered by Sample Set C, which had several analyses after compositing as required in the nuclear criticality safety evaluation (NCSE).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SALTSTONE 1QCY11 TCLP RESULTS

A Saltstone waste form was prepared in the Savannah River National Laboratory (SRNL) from a Tank 50H sample and Z-Area premix material for the first quarter of calendar year 2011 (1QCY11). After the prescribed 28 day cure, samples of the saltstone were collected, and the waste form was shown to meet the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24 and R.61-79.268.48(a) requirements for a nonhazardous waste form with respect to RCRA metals and underlying hazardous constituents. These analyses met all quality assurance specifications of USEPA SW-846. The Saltstone Production Facility (SPF) receives waste from Tank 50H for treatment. In the first quarter of the 2011 calendar year (1QCY11), Tank 50H accepted transfers of approximately 15 kgal from the Effluent Treatment Project (ETP), approximately 15 kgal from Tank 710 - the H-Canyon General Purpose Evaporator, approximately 73 kgal from the H-Canyon Super Kukla campaign, approximately 285 kgal from the Actinide Removal Process/Modular Caustic Side Solvent Extraction Unit (ARP/MCU) Decontaminated Salt Solution Hold Tank (DSS-HT), and approximately 21 kgal from other sources. The Saltstone Grout Sampling plan provides the South Carolina Department of Health and Environmental Control (SCDHEC) with the chemical and physical characterization strategy for the salt solution which is to be disposed of in the Z-Area Solid Waste Landfill (SWLF). During operation, samples were collected from Tank 50H and grout samples prepared to determine the non-hazardous nature of the grout to meet the requirements of the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24(b) and R.61-79.268.48(a). Savannah River National Laboratory (SRNL) was asked to prepare saltstone from samples of Tank 50H obtained January 5, 2011 during 1QCY11 to determine the non-hazardous nature of the grout. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&W TSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals-arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver-analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. B&W TSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the UHCs benzene, phenols and total and amenable cyanide.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioactive waste immobilization of Hanford sludge in magnesium potassium phosphate ceramic forms

Here, this paper evaluates immobilization of Hanford K-Basin tank sludge in magnesium potassium phosphate ceramic forms. The waste forms were produced using two simulated non-radioactive sludge streams, each with distinct characteristics and composition. Ceramicrete with wollastonite as filler was used as the matrix for this purpose. The resulting waste forms were tested for their mechanical properties, radiation stability, and leaching resistance. In another series of tests, the samples were vitrified in borosilicate glass and glass waste forms were produced. The Product Consistency Test, the American Nuclear Society's ANS 16.1 test, and the Toxicity Characteristic Leaching Procedure, which are used to develop waste acceptance criteria in the United States for permanent storage of treated waste, were used for evaluation of the leaching resistance of all waste forms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Impedance Humidity Sensor Based on CVD Grown WSe 2 2D Films

2D materials-based planar devices have been sought after for gas and humidity sensor applications owing to their high sensitivity due to their ultrathin nature and increased surface area. Herein, 2D WSe 2 films-based planner devices were fabricated to evaluate their performance for potential application in humidity sensors. The structure and morphology of the WSe 2 sensing films were studied by Raman spectroscopy, photoluminescence, optical microscopy, and scanning electron microscopy (SEM) techniques. The relative humidity-dependent sensing performances of the 2D WSe 2 films were evaluated using current–voltage (I–V), relative impedance, and complex total impedance (electrochemical impedance spectroscopy, EIS) techniques. This sensor showed a very stable and repeatable performance investigated over the period of 18 months. The response and recovery times of the WSe 2 -based impedance sensors were found to be 40 and 30 s, respectively. The WSe 2 sensor exhibits a 2 ± 1% minimum hysteresis at a lower humidity level (50% RH) and around 8 ± 2% maximum hysteresis at relative humidity level (70% RH). This value of hysteresis is in the acceptable range during the initial investigation of any material to explore its potential for application in humidity sensors. The density functional theory (DFT) analysis was performed with the interaction from water molecules of the WSe 2 sample for a better understanding of the sensing mechanism of devices.

2D- WSe2↗

Modeling the Air Flow in the 3410 Building Filtered Exhaust Stack System

Additional ventilation capacity has been designed for the 3410 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and will include ductwork to incorporate the new fan into the existing stack. Stack operations will involve running various two-fan combinations at any given time. The air monitoring system of the existing two-fan stack was previously found to be in compliance with the ANSI/HPS N13.1-1999 standard, however it is not known if the modified (three-fan) system will comply. Subsequently, a full-scale three-dimensional (3-D) computational fluid dynamics (CFD) model of the modified stack system has been created to examine the sampling location for compliance with the standard. The CFD modeling results show good agreement with testing data collected from the existing 3410 Building stack and suggest that velocity uniformity and flow angles will remain well within acceptance criteria when the third fan and associated ductwork is installed. This includes two-fan flow rates up to 31,840 cfm for any of the two-fan combinations. For simulation cases in which tracer gas and particles are introduced in the main duct, the model predicts that both particle and tracer gas coefficients of variance (COVs) may be larger than the acceptable 20 percent criterion of the ANSI/HPS N13.1-1999 standard for each of the two-fan, 31,840 cfm combinations. Simulations in which the tracers are introduced near the fans result in improved, though marginally acceptable, COV values for the tracers. Due to the remaining uncertainty that the stack will qualify with the addition of the third fan and high flow rates, a stationary air blender from Blender Products, Inc. is considered for inclusion in the stack system. A model of the air blender has been developed and incorporated into the CFD model. Simulation results from the CFD model that includes the air blender show striking improvements in tracer gas mixing and tracer particle dispersion. The results of these simulations suggest the air blender should be included in the stack system to ensure qualification of the stack.

3410 Building↗

Tonopah Test Range Air Monitoring: CY2018 Meteorological, Radiological, and Wind Transported Particulate Observations

In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This operation resulted in radionuclide-contaminated soils at the Double Tracks site and Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to the Clean Slate sites and at the TTR Sandia National Laboratories (SNL) Range Operations Center (ROC). The primary objective of the monitoring effort is to support the DOE Environmental Management Nevada Program (EM NV) in the safe remediation of the environmental legacy of nuclear device development and testing by determining if wind blowing across the Clean Slate sites is transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites, and to provide information for designing long-term monitoring of the sites. The monitoring program in 2018 included five stations. Station 400, located within TTR Area 3 and near the ROC, monitors conditions near the local workforce center. Stations 401 and 403 are located on the northern and southeastern perimeter fence lines, respectively, of the Clean Slate III site. Stations 404 and 405 are along the northern and eastern boundary fence, respectively, at Clean Slate II. The stations are generally downwind of the contaminated areas during either northwesterly or southerly winds, which are the predominant wind directions. The stations—which are similar in design to the Community Environmental Monitoring Program (CEMP) stations operating at locations surrounding the Nevada National Security Site and TTR—include meteorological instruments and continuous-flow, low-volume air samplers. Three pressurized ionization chambers for measuring gamma energy are in use at Stations 400, 401, and 403. Saltation sensors and saltation traps are deployed at the stations adjacent to the Clean Slate sites. Detailed meteorological data are recorded on data loggers, with periodic uploads via a satellite system to the Western Regional Climate Center (WRCC) at Desert Research Institute (DRI), to monitor instrument and site conditions. Air filter samples are collected every two weeks and the deposits in the saltation traps are collected when a sufficient sample mass for analysis has accumulated (generally a six- to eight-month interval). Monitoring at TTR in calendar year (CY) 2018 provided surveillance of both ambient conditions, and ground disturbance associated with remediation activities at Clean Slate II and III. The first half of CY2018 data from Stations 404 and 405 at Clean Slate II were collected during remediation activities at that site, and data collected during the final third of the year at Stations 401 and 403 at Clean Slate III coincided with remediation work at the site. Ambient conditions prevailed at Station 400 throughout the year. Dust transport by suspension and saltation is strongly dependent on wind speed. Concentrations of PM 10 (particulate matter of aerodynamic diameter ≤10 micrometers [μm], a size fraction of small particles that are suspended in the air and can be easily inhaled) remain low until winds exceed approximately 32 kilometers per hour (km/hr) (20 miles per hour [mph]). Saltation particle counts also increase above the same general threshold wind speed. Wind speeds in excess of 32 km/hr (20 mph) occur less than three percent of the time at the sites. Ground disturbing remediation activities were carried out at Clean Slate II from October 31, 2017, until July 26, 2018. Station 404 is located closest to the remediation area and is downwind of the area when winds are from the south. By late November, analysis of dust from the air sampler at Station 404 registered increases in plutonium-239+240 ( 239+240 Pu) concentrations. Peak plutonium concentrations, accompanied by elevated gross alpha concentrations and the detection of americium-241 ( 241 Am) by gamma spectroscopy, occurred between March and May 2018. During spring and early summer of 2018, elevated radionuclide concentrations were also measured in dust collected from the air sampler at Station 405, which is more than twice the distance from the remediation activity as Station 404. A minor but sustained increase in gross alpha concentration of suspended dust collected at Stations 400, 401, and 403 was also observed starting in May 2018 and continuing into August. Stations 401 and 403 are approximately 4.8 to 6.4 km (three to four miles) from Clean Slate II and Station 400 is approximately 13 km (eight miles) from that site. The radionuclide content of material that saltated into the passive Big Spring Number Eight (BSNE) traps during the Clean Slate II remediation period increased in both the traps facing toward and away from the fenced contamination area at Station 404, with the largest increases in concentration (almost five times the previous 239+240 Pu concentration) observed in the traps facing the fenced area. The radionuclide concentration in material in the trap facing away from the fence more than doubled from that measured in 2017. A similar increase was observed for the saltation trap facing away from the fenced area at Station 405, although no increase was observed for material captured in the trap facing the fenced area. Particles ranging in size from 50 to 500 µm generally move by saltation processes and are not expected to significantly contribute to dose for someone breathing in the standard respiratory zone for adult humans (1.5 to 1.7 m [4.9 to 5.6 ft] above ground level) because they are too large to be entrained in the air as suspended dust. Remediation activities at Clean Slate III began on September 5, 2018, and continued until a brief hiatus started on December 20, 2018. Although Station 401 is much closer to the remediation area than Station 403, the first increase in gross alpha and 239+240 Pu concentrations was noted in dust from filters collected at Station 403 in early November 2018. The highest radionuclide concentrations of 2018 at the Clean Slate III stations were recorded in air samples taken from Stations 401 and 403 in late December 2018 and these concentrations were comparable between the two station locations. Gamma rate data measured by the PICs was slightly higher than the annual average at Stations 401 and 403 after remediation activities began, but no single measurement was outside of the range observed in 2018 prior to remediation activities. No increase in radionuclide concentration was observed for the Clean Slate III remediation time period on air filters collected from the other stations. Radiological monitoring at Station 400—which is located at the ROC, and therefore the closest regularly staffed work location to the Clean Slate sites—recorded a higher mean gross alpha activity from dust collected on air sampler filters than in previous years. The individual biweekly air filters yielded measurements of gross alpha that were at or below the mean plus one standard deviation measured in CY2017, except for the period from April 25, 2018, through September 12, 2018. Nonetheless, gamma spectroscopy of all air filters from Station 400 identified only naturally occurring radionuclides, with no detection of americium-241 ( 241 Am) (which is used as an indicator of plutonium-241[ 241 Pu]). Alpha spectroscopy of selected air filters collected at Station 400 did not detect plutonium-238 ( 238 Pu) or 239+240 Pu above the analytical detection limit. Gross beta and gamma exposure rate data were comparable to data from regional CEMP stations. No saltation traps are deployed at Station 400. Considering the ambient monitoring periods during CY2018, the monitoring stations adjacent to the Clean Slate sites recorded above-background 238 Pu and 239+240 Pu concentrations (SNL, 1998; Turner et al., 2003) in samples collected by passive saltation traps and on selected air filters. These observations were consistent with previous years and indicated that radionuclide movement occurred under ambient conditions by processes of both saltation and suspension. The presence of radionuclides in all saltation traps, both upwind and downwind of the fenced contamination areas, was consistent with previous radiological survey results (EG&G, 1979) that show lower concentration radiologically contaminated material dispersed outside the fenced area. Although 239+240 Pu concentrations in the air filter samples were sometimes orders of magnitude higher than background, the concentrations were below risk-based action levels defined for an industrial area worker scenario (U.S. DOE, 2014). The interception of airborne dust with above-background radionuclide concentrations demonstrates that dispersal processes are continuing. Strong winds are the driver for both suspension and saltation of dust and soil. The recorded wind speed and PM10 during remediation activities at Clean Slate II and III identified discrete wind events lasting approximately five to eight hours each, which accounted for the greatest PM 10 concentrations at the monitoring stations. These events captured the effect of winds from the northwest and from the south. The observed differences in dust loading and radionuclide concentrations for the monitoring stations when they were either upwind or downwind of the contamination area identify the remediation area as a source of plutonium contaminated dust. The increase in concentration of radionuclides in airborne dust during the remediation activities, compared with measurements under previous ambient conditions (mean 239+240 Pu concentrations during remediation activities are approximately nine to 40 times higher compared to pre-remediation concentrations, depending on monitoring station), highlights the impact of land disturbance on wind-borne contaminant transport from the Clean Slate test areas. The meteorological and particulate matter monitoring indicated that conditions for wind-borne contaminant movement exist at the Clean Slate sites, and that transport of radionuclide-contaminated soil by both suspension and saltation occurred under ambient conditions and accelerated when the sites were disturbed. The 239+240 Pu alpha spectroscopy results indicated that airborne concentrations during remediation activities ranged from 2 × 10-16 to 380 × 10-16 µCi/ml. These results can be compared to the derived air concentration limit for 239 Pu of 6 × 10-11 µCi/ml for occupational workers contained in Code of Federal Regulations 10 CFR 835, Occupational Radiation Protection. Even though the air sampling results document an increase in concentration during remediation activities, the observed concentrations are less than 0.06 percent of the occupational limit. The Corrective Action Unit (CAU) closure strategy uses a risk-based approach, whereby acceptable contaminant concentrations are determined as a function of anticipated human exposure.

54 ENVIRONMENTAL SCIENCES↗

Distributed micro-releases of bioterror pathogens : threat characterizations and epidemiology from uncertain patient observables.

Terrorist attacks using an aerosolized pathogen preparation have gained credibility as a national security concern since the anthrax attacks of 2001. The ability to characterize the parameters of such attacks, i.e., to estimate the number of people infected, the time of infection, the average dose received, and the rate of disease spread in contemporary American society (for contagious diseases), is important when planning a medical response. For non-contagious diseases, we address the characterization problem by formulating a Bayesian inverse problem predicated on a short time-series of diagnosed patients exhibiting symptoms. To keep the approach relevant for response planning, we limit ourselves to 3.5 days of data. In computational tests performed for anthrax, we usually find these observation windows sufficient, especially if the outbreak model employed in the inverse problem is accurate. For contagious diseases, we formulated a Bayesian inversion technique to infer both pathogenic transmissibility and the social network from outbreak observations, ensuring that the two determinants of spreading are identified separately. We tested this technique on data collected from a 1967 smallpox epidemic in Abakaliki, Nigeria. We inferred, probabilistically, different transmissibilities in the structured Abakaliki population, the social network, and the chain of transmission. Finally, we developed an individual-based epidemic model to realistically simulate the spread of a rare (or eradicated) disease in a modern society. This model incorporates the mixing patterns observed in an (American) urban setting and accepts, as model input, pathogenic transmissibilities estimated from historical outbreaks that may have occurred in socio-economic environments with little resemblance to contemporary society. Techniques were also developed to simulate disease spread on static and sampled network reductions of the dynamic social networks originally in the individual-based model, yielding faster, though approximate, network-based epidemic models. These reduced-order models are useful in scenario analysis for medical response planning, as well as in computationally intensive inverse problems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then be generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the computation time decrease with the number of points and that no effects were observed on the dosimetric indices when varying the number of sampling points and the number of iterations, they were respectively fixed to 2500 and to 100. The computation time to obtain ten complete treatments plans ranging from 9 to 18 catheters, with the corresponding dosimetric indices, was 90 s. However, 93% of the computation time is used by a research version of IPSA. For the breast, on average, the Radiation Therapy Oncology Group recommendations would be satisfied down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of V100, dose homogeneity index, and D90.Conclusions: The authors have devised a simple, fast and efficient method to optimize the number and position of catheters in interstitial HDR brachytherapy. The method was shown to be robust for both prostate and breast HDR brachytherapy. More importantly, the computation time of the algorithm is acceptable for clinical use. Ultimately, this catheter optimization algorithm could be coupled with a 3D ultrasound system to allow real-time guidance and planning in HDR brachytherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Methylmercury and Ethylmercury Analytical Performance in SRR Samples Measured by SRNL and Eurofins Frontier Global Sciences

Existing models and simulants of tank disposition media at the Savannah River Site (SRS) have presumed the presence of high concentrations of inorganic mercury. However, quarterly Tank 50 analyses have shown that mercury is present as organomercurial species at concentrations that may present challenges to its remediation and disposition and may challenge the Waste Acceptance Criteria (WAC) for Saltstone. Todate, methylmercury analyses for Savannah River Remediation (SRR) have been performed at an off-site laboratory by Eurofins Frontier Global Sciences (FGS) in Bothell, WA. Savannah River Remediation requested the development of methylmercury and ethylmercury determination capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins FGS. This document reports on this method development work as well as the comparative analyses conducted between the two laboratories. A series of optimization and validation experiments has been performed at SRNL, which has resulted in the development of on-site methylmercury and ethylmercury speciation capabilities using purge and trap (P&T) gas chromatography (GC) coupled with thermal desorption (TD) cold vapor – atomic fluorescence spectroscopy (CVAFS). Speciation has been achieved for both species, with a methylmercury method reporting limit (MRL) value of 1.13 pg and an overall uncertainty (1σ) of 5.1%. An ethylmercury MRL of 11.5 pg and an overall uncertainty (1σ) of 4.8% were obtained. These analytical parameters compare favorably with Eurofins FGS, which demonstrates uncertainties (1σ) for methylmercury and ethylmercury of 13% and 9.1%, respectively. Results obtained by SRNL from the routine analysis of Tanks 21, 40, 50, and 51 samples have provided statistically indistinguishable results compared with Eurofins FGS. Based upon the work performed by SRNL-AD and the data currently available, the following recommendations can be made: Further work should be performed to determine a “best practices” for sample holding time prior to analysis (both preserved and non-preserved samples), as well as any detrimental effects sample age may have on data quality. Analysis of ethylmercury is only recommended for tank samples that are reasonably expected to have significant quantities of ethylmercury, such as from the DWPF SMECT. Trace levels of ethylmercury in the presence of large quantities of methylmercury can be difficult or impossible to quantify. SRNL-AD development of methods for total mercury, purgeable mercury (which includes Hg(0) and dimethylmercury), inorganic mercury (Hg(I) and Hg(II)), dissolved mercury, and particulate mercury are underway and will be reported upon separately.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards fast and accurate predictions of radio frequency power deposition and current profile via data-driven modelling: applications to lower hybrid current drive

Three machine learning techniques (multilayer perceptron, random forest and Gaussian process) provide fast surrogate models for lower hybrid current drive (LHCD) simulations. A single GENRAY/CQL3D simulation without radial diffusion of fast electrons requires several minutes of wall-clock time to complete, which is acceptable for many purposes, but too slow for integrated modelling and real-time control applications. The machine learning models use a database of more than 16 000 GENRAY/CQL3D simulations for training, validation and testing. Latin hypercube sampling methods ensure that the database covers the range of nine input parameters ( $n_{e0}$ , $T_{e0}$ , $I_p$ , $B_t$ , $R_0$ , $n_{\|}$ , $Z_{{\rm eff}}$ , $V_{{\rm loop}}$ and $P_{{\rm LHCD}}$ ) with sufficient density in all regions of parameter space. The surrogate models reduce the inference time from minutes to $\sim$ ms with high accuracy across the input parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric property of mineral extracted from calamari and exposed to gamma rays

Dosimetric property of polymineral fraction, quartz mainly, obtained from calamari was investigated. The commercial calamari samples from China and Sud Africa were collected in the markets of Italy. All polymineral debris were extracted and isolated from the whole body of calamari. The surface of the polymineral samples was analyzed by using the Scanning Electron Microscopy (SEM) and their chemical composition was determined using Energy Dispersive Spectroscopy (EDS). The polymineral was exposed to gamma rays ({sup 60}Co) at different doses (0.5-80 Gy) to determine dosimetric property. Thermoluminescent (TL) glow curves showed two peaks centered at around 98-100 Degree-Sign C and 128-138 Degree-Sign C temperature range. The glow curves have been analyzed by using a deconvolution program. A linear dose response between 0.5 to 20 Gy was observed. The TL response of the samples as a function of the time storage, fading, presented a reduction of about 36-40 % at the end of 24 h. The reproducibility of the TL response after ten cycles of irradiation-readout showed an acceptable standard deviation in dosimetry. The polimineral fraction obtained from calamari shows an interesting dosimetric property and it may be useful for dosimetry in gamma radiation field.

36 MATERIALS SCIENCE↗

Measurement of Upsilon production in 7 TeV pp collisions at ATLAS

CERN-LHC. Measurements of the production cross sections for Upsilon 1S, 2S and 3S mesons in proton-proton collisions at a centre-of-mass energy of 7 TeV. The data sample used has an integrated luminosity of 1.8 fb-1 collected between March and August 2011. The data cover the Upsilon |y| region 0-2.25 and PT < 70 GeV/c. The data are given assuming unpolarized Upsilon production. Acceptance weights are also given in the link below for the effects of different polarization scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IER 557: Godiva Pulse Repeatability and Characterization (CED-3A Report)

Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5% molybdenum for strength. Godiva IV is proposed as the radiation source for IER 498: Design a Shielding Benchmark with a Metal Critical Source. IER 498 proposes a two-burst method to determine the performance of shielding samples, comparing the transmission of the source radiation to detectors with and without a shielding sample present. This eliminates the need for an absolute calibration and allows many uncertainties to cancel. However, the source term variability must be low compared to other sources of experimental uncertainty to ensure the overall uncertainty meets acceptable levels to provide useful measurements. The primary goal of this experiment is to quantify the source term variability, or reproducibility, of Godiva bursts, focusing on the 70 °C bursts planned for IER 498 measurements. Discussions during IER 498 noted that a number of bursts (on the order of six to ten) as identical as possible would be performed and that a 5-7% standard deviation in source intensity would be acceptable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demonstration of Optimal Benchmark Selection Website and Validation of the q c Coverage Metric Using HEU-SOL-THERM-013-003 Experiment

In the work documented in this interim report, the experiment selection toolkit web site was demonstrated and q C coverage metric methodology was validated for IEU-MET-FAST-002-001, MIX-COMP-THERM 004-004, and HEU-SOL-THERM-013-003 experiments. 𝑞 𝐶 is an information-theoretic measure based on mutual information that quantifies the ability of candidate benchmark experiments to reduce the bias and uncertainty of a target criticality safety application. The metric and an accompanying open-source Python toolkit with a web-based interface were tested against a benchmark set of 425 experiments drawn from the International Criticality Safety Benchmark Evaluation Project Handbook. The interface is hosted at https://edim.covdef.com. It accepts sensitivity data files produced by the TSUNAMI-IP module of the SCALE code system and supports both (i) deterministic analysis using the ENDF/B-VII.0 covariance library and (ii) stochastic analysis based on user-supplied keff samples. Demonstrations on representative applications across a range of material composition, spectrum, and form show that q C -guided benchmark selection achieves greater uncertainty reduction with fewer experiments and yields more stable posterior bias and uncertainty estimates than traditional similarity coefficient ( c k )–based selection, while also capturing valuable low-ck experiments that one-to-one metrics overlook.

Abdel-khalik, Hany S. [Indiana Univ.-Purdue Univ. ↗

Wasserstein Normalized Autoencoder for Anomaly Detection in ProtoDUNE Vertical-Drift Detector

ProtoDUNE Vertical Drift needs a selective triggering algorithm. The detector sits on Earth's surface, so cosmic activity dominates its data. Our goal in this paper is to trigger on neutrino events more robustly than the current deployed Analog-to-Digital Converter Simple Window (ADCSW) model and, eventually, search for signals of Beyond Standard Model (BSM) physics at DUNE as our ultimate North Star objective. As a step towards this goal, we evaluate a Wasserstein Normalized Autoencoder (WNAE) on simulated collection-plane only windows of shape $1\times10\times10$ where Neutrinos act as our BSM-proxy and Cosmic-ray Muons serve as our learned background. The network parameters are fitted using only cosmic-ray muon events as background in order to maintain an unsupervised pipeline. Training uses finite-step Langevin $x^-$ samples, positive-sample reconstruction energy, and an empirical sliced $2$-Wasserstein objective to learn a normalized Boltzmann energy model. We then calibrate on a nominal $5\,\mathrm{Hz}$ operating threshold calculated from cosmic validation data. Both WNAE and ADCSW accept 311 of 194,083 held-out cosmic background events at this $5\,\mathrm{Hz}$ threshold. We found that WNAE accepts 9,677 of 34,634 neutrino-proxy events $(27.9\pm0.24)\%$, compared with 10,076 $(29.1\pm0.24)\%$ for ADCSW, an observed WNAE-minus-ADCSW difference of $-1.15\%$. At another nominal $2\,\mathrm{Hz}$ target threshold, the corresponding efficiencies are $(20.5\pm0.22)\%$ and $(22.6\pm0.22)\%$, respectively. Of the WNAE-selected neutrino proxies at $5\,\mathrm{Hz}$, $(20.8\pm0.4)\%$ of the classified neutrino-proxy events are unique to WNAE, where the uncertainty is an absolute binomial standard error of $0.4\%$.

Zheng, Jake [U. Chicago (main)] (ORCID:00090002189↗

Wasserstein Normalized Autoencoder for Anomaly Detection in ProtoDUNE Vertical-Drift Detector

ProtoDUNE Vertical Drift needs a selective triggering algorithm. The detector sits on Earth's surface, so cosmic activity dominates its data. Our goal in this paper is to trigger on neutrino events more robustly than the current deployed Analog-to-Digital Converter Simple Window (ADCSW) model and, eventually, search for signals of Beyond Standard Model (BSM) physics at DUNE as our ultimate North Star objective. As a step towards this goal, we evaluate a Wasserstein Normalized Autoencoder (WNAE) on simulated collection-plane only windows of shape $1\times10\times10$ where Neutrinos act as our BSM-proxy and Cosmic-ray Muons serve as our learned background. The network parameters are fitted using only cosmic-ray muon events as background in order to maintain an unsupervised pipeline. Training uses finite-step Langevin $x^-$ samples, positive-sample reconstruction energy, and an empirical sliced $2$-Wasserstein objective to learn a normalized Boltzmann energy model. We then calibrate on a nominal $5\,\mathrm{Hz}$ operating threshold calculated from cosmic validation data. Both WNAE and ADCSW accept 311 of 194,083 held-out cosmic background events at this $5\,\mathrm{Hz}$ threshold. We found that WNAE accepts 9,677 of 34,634 neutrino-proxy events $(27.9\pm0.24)\%$, compared with 10,076 $(29.1\pm0.24)\%$ for ADCSW, an observed WNAE-minus-ADCSW difference of $-1.15\%$. At another nominal $2\,\mathrm{Hz}$ target threshold, the corresponding efficiencies are $(20.5\pm0.22)\%$ and $(22.6\pm0.22)\%$, respectively. Of the WNAE-selected neutrino proxies at $5\,\mathrm{Hz}$, $(20.8\pm0.4)\%$ of the classified neutrino-proxy events are unique to WNAE, where the uncertainty is an absolute binomial standard error of $0.4\%$.

Zheng, Jake [Chicago U.] (ORCID:0009000218901379)↗

New Method to Characterize Degradation of First Surface Aluminum Reflectors: Preprint

This paper reports the development of a new optical instrument capable of characterizing the aging process of enhanced first surface aluminum reflectors for concentrating solar power (CSP) application. Samples were exposed outdoors at different sites and in accelerated exposure tests. All samples exposed outdoors showed localized corrosion spots. Degradation originated from points of damage inthe protective coating, but propagated underneath the protective coating. The degraded samples were analyzed with a microscope and with a newly designed space-resolved specular reflectometer (SR)2 that is capable of optically detecting and characterizing the corrosion spots. The device measures the specular reflectance at three acceptance angles and the wavelengths with spatial resolution usinga digital camera's CMOS sensor. It can be used to measure the corrosion growth rate during outdoor and accelerated exposure tests. These results will allow a correlation between the degraded mirror surface and its specular reflectance.

14 SOLAR ENERGY↗