Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Measurement Acceptance Region (MAR) Assessment Results Based On Sludge Batch 10 Projections from December 2021, February 2022 and August 2022

The Defense Waste Processing Facility (DWPF) is currently preparing to initiate processing of Sludge Batch 10 (SB10), which is comprised of material from Tanks 11H, 13H, 15H, and 26F, Alternate Feed Stock-2 and Sodium Reactor Experiment material from H-Canyon. Frit 473 (8B 2 O 3 -8Li 2 O-5Na 2 O-79SiO 2 , in weight percent) was recommended for sludge-only (SO) and coupled processing with the Salt Waste Processing Facility (SWPF) based on previous assessments of SB10 projections with the DWPF Product Composition Control System (PCCS) glass property models and their associated Measurement Acceptance Region (MAR) constraints. Due to the lower processing rate of Sludge Batch 9 (SB9), the heel in Tank 40 is anticipated to be greater than 40 inches at the projected start of SB10 processing to meet the upcoming Accelerated Basin Deinventory addition dates in Tank 51 for Sludge Batch 11. In December 2021 and February 2022, Savannah River Remediation System Planning provided updated SB10 Tank 40 blend projections based on heels of 74 inches, 84 inches, 94 inches and 103.4 inches. Savannah River Mission Completion (SRMC) subsequently pursued Wash Cycle Y to further reduce the total sulfur in the sludge batch and increase processing flexibility at DWPF. In August 2022, SRMC System Planning provided an updated SB10 Tank 40 blend projection with a 76 inch-heel representing Decant Y2 and 60 kilogallons of bearing water inleakage that is anticipated during the Tank 51 to Tank 40 transfer. The objectives of this task were to: • Determine the impact on the operating windows for SO and coupled processing • Determine whether any composition gaps exist between the already completed SB10 variability study and the reprojected SB10 glass composition region • Compare the SB10 reprojected glass composition region to the DWPF PCCS model development and validation ranges to ensure that compositional gaps do not exist between the data sets. This report documents the results of these evaluations. Calculation-based frit assessments were performed using the DWPF PCCS glass property models and their associated MAR constraints. Evaluated parameters for coupled processing included the following transfer volumes per Sludge Receipt and Adjustment Tank batch: 5700 gallons of Tank 40 sludge, 2400-4500 gallons of the SWPF monosodium titanate (MST) and sludge solids stream, and 15,000 gallons of strip effluent. Based on these MAR assessment results, Frit 473 remains viable for SB10 processing. A target waste loading (WL) of 36% is possible for SO operation and single strike (0.4 g/L MST) coupled processing up to 600 mg/L of SB9 insoluble sludge solids at a nominal transfer volume of ~2800 gallons. Increasing the single strike transfer volume to 4500 gallons may reduce the maximum WL below 40%. Operating windows are 12 percentage points for SO processing and 14-16 percentage points for coupled processing. Frit 625 allows for a target WL of 36% and is acceptable for use during the SB9 to SB10 transition to deplete remaining inventory as needed. Operating windows are 8 percentage points for SO processing and 12-14 percentage points for coupled processing. Predictive PCCS evaluations performed at DWPF will provide insight into batch-specific acceptability at desired WLs for compositions having expected oxide ratios during processing versus the extreme vertices (corner points) evaluated in this study. The reprojected SB10 glass composition region generally overlaps the previously evaluated SB10 variability study composition region. Thus, the minor composition shift of these updated SB10 projections indicates that no additional glasses are necessary to demonstrate acceptability relative to the chemical durability of the Environmental Assessment benchmark glass and predictability using the current PCCS models for durability. Based on a comparison of the PCCS model development and validation data to the reprojected SB10 glass composition region, the viscosity and liquidus temperature models will reliably predict SB10 compositions. No additional glasses are necessary to demonstrate predictability of these models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Statistical Standard Siren Measurement of the Hubble Constant from the LIGO/Virgo Gravitational Wave Compact Object Merger GW190814 and Dark Energy Survey Galaxies

We present a measurement of the Hubble constant H 0 using the gravitational wave (GW) event GW190814, which resulted from the coalescence of a 23 M ⊙ black hole with a 2.6 M ⊙ compact object, as a standard siren. No compelling electromagnetic counterpart has been identified for this event; thus our analysis accounts for thousands of potential host galaxies within a statistical framework. The redshift information is obtained from the photometric redshift (photo- z ) catalog from the Dark Energy Survey. The luminosity distance is provided by the LIGO/Virgo gravitational wave sky map. Since this GW event has the second-smallest localization volume after GW170817, GW190814 is likely to provide the best constraint on cosmology from a single standard siren without identifying an electromagnetic counterpart. Furthermore, our analysis uses photo- z probability distribution functions and corrects for photo- z biases. We also reanalyze the binary black hole GW170814 within this updated framework. We explore how our findings impact the H 0 constraints from GW170817, the only GW merger associated with a unique host galaxy. From a combination of GW190814, GW170814, and GW170817, our analysis yields H 0 =72.0$_{+12}^{–8.2}$ km s -1 Mpc -1 (68% highest-density interval, HDI) for a prior in H 0 uniform between [20 and 140] km s -1 Mpc -1 . The addition of GW190814 and GW170814 to GW170817 improves the 68% HDI from GW170817 alone by ~18%, showing how well-localized mergers without counterparts can provide a significant contribution to standard siren measurements, provided that a complete galaxy catalog is available at the location of the event.

79 ASTRONOMY AND ASTROPHYSICS↗

The Atacama Cosmology Telescope: Weighing Distant Clusters with the Most Ancient Light

We use gravitational lensing of the cosmic microwave background (CMB) to measure the mass of the most distant blindly selected sample of galaxy clusters on which a lensing measurement has been performed to date. In CMB data from the the Atacama Cosmology Telescope and the Planck satellite, we detect the stacked lensing effect from 677 near-infrared-selected galaxy clusters from the Massive and Distant Clusters of WISE Survey (MaDCoWS), which have a mean redshift of $\langle z\rangle =1.08$. There are currently no representative optical weak lensing measurements of clusters that match the distance and average mass of this sample. We detect the lensing signal with a significance of $4.2\sigma $. We model the signal with a halo model framework to find the mean mass of the population from which these clusters are drawn. Assuming that the clusters follow Navarro–Frenk–White (NFW) density profiles, we infer a mean mass of $\langle {M}_{500c}\rangle =\left(1.7\pm 0.4\right)\times {10}^{14}\,{M}_{\odot }$. We consider systematic uncertainties from cluster redshift errors, centering errors, and the shape of the NFW profile. These are all smaller than 30% of our reported uncertainty. This work highlights the potential of CMB lensing to enable cosmological constraints from the abundance of distant clusters populating ever larger volumes of the observable universe, beyond the capabilities of optical weak lensing measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Lab-On-a-Chip Application Development (LOCAD): Bridging Technology Readiness for Exploration

At Marshall Space Flight Center we have established a capability to investigate the use of microfluidics for space flight. The Lab-On-a-Chip Application Development (LOCAD) team has created a program for advancing Technology Readiness Levels (TRL) of 1 and 2 to TRL 6 and 7, quickly and economically for Lab-On-a-Chip (LOC) applications. Scientists and engineers can utilize LOCAD'S process to efficiently learn about microfluidics and determine if microfluidics is applicable to their needs. Once the applicability has been determined, LOCAD can then perform tests to develop the new fluidic protocols which are different from macro-scale chemical reaction protocols. With this information new micro-fluidic devices can be created and tested. Currently, LOCAD is focused on using microfluidics for both Environmental Monitoring & Control, and Medical Systems. Eventually, handheld portable units utilizing LOC technology will perform rapid tests to determine water quality, and microbial contamination levels. Since LOC technology is drastically reduced in physical size, it thereby reduces power, weight, volume, and sample requirements, a big advantage considering the resource constraints associated with spaceflight. Another one of LOCAD's current activities is the development of a microfluidic system to aid in the search for life on Mars.

Spearing, Scott F.↗

In-Space Assembly Capability Assessment for Potential Human Exploration and Science Applications

Human missions to Mars present several major challenges that must be overcome, including delivering multiple large mass and volume elements, keeping the crew safe and productive, meeting cost constraints, and ensuring a sustainable campaign. Traditional methods for executing human Mars missions minimize or eliminate in-space assembly, which provides a narrow range of options for addressing these challenges and limits the types of missions that can be performed. This paper discusses recent work to evaluate how the inclusion of in-space assembly in space mission architectural concepts could provide novel solutions to address these challenges by increasing operational flexibility, robustness, risk reduction, crew health and safety, and sustainability. A hierarchical framework is presented to characterize assembly strategies, assembly tasks, and the required capabilities to assemble mission systems in space. The framework is used to identify general mission system design considerations and assembly system characteristics by assembly strategy. These general approaches are then applied to identify potential in-space assembly applications to address each challenge. Through this process, several focus areas were identified where applications of in-space assembly could affect multiple challenges. Each focus area was developed to identify functions, potential assembly solutions and operations, key architectural trades, and potential considerations and implications of implementation. This paper helps to identify key areas to investigate were potentially significant gains in addressing the challenges with human missions to Mars may be realized, and creates a foundation on which to further develop and analyze in-space assembly concepts and assembly-based architectures.

Jefferies, Sharon A.↗

Impacts of In-Space Assembly as Applied to Human Exploration Architectures

Human missions to Mars present several major challenges that must be overcome, including delivering multiple large mass and volume elements, keeping the crew safe and productive, meeting cost constraints, and ensuring a sustainable campaign. Traditional methods for executing human Mars missions minimize or eliminate in-space assembly (iSA), which provides a narrow range of options for addressing these challenges and limits the types of missions that can be performed. This paper discusses recent work to evaluate how the inclusion of in-space assembly in space mission architectural concepts could provide novel solutions to address these challenges by increasing operational flexibility, robustness, risk reduction, crew health and safety, and sustainability. Several assembly focus areas identified through previous work were developed and evaluated to identify high-potential iSA applications that can have meaningful impacts on the challenges facing Mars missions. Architecture trade options were developed and assessed through sensitivity analyses, resulting in identification of six iSA-based architecture solutions that could be incorporated into Mars mission architectures with moderate levels of assembly. Assembly agent and infrastructure concepts were also developed that would be necessary to enable or facilitate the iSA operations. Several observations developed through the study are presented to inform future human mission architecture and campaign developments.

Jefferies, Sharon A.↗

The Atacama Cosmology Telescope: Weighing Distant Clusters with the Most Ancient Light

We use gravitational lensing of the cosmic microwave background (CMB) to measure the mass of the most distant blindly selected sample of galaxy clusters on which a lensing measurement has been performed to date. In CMB data from the the Atacama Cosmology Telescope and the Planck satellite, we detect the stacked lensing effect from 677 near-infrared-selected galaxy clusters from the Massive and Distant Clusters of WISE Survey (MaDCoWS), which have a mean redshift of (z)=1.08. There are currently no representative optical weak lensing measurements of clusters that match the distance and average mass of this sample. We detect the lensing signal with a significance of . We model the signal with a halo model framework to find the mean mass of the population from which these clusters are drawn. Assuming that the clusters follow Navarro–Frenk–White (NFW) density profiles, we infer a mean mass of (M(500c))=(1.7 ± 0.4) x 10^14M(ʘ). We consider systematic uncertainties from cluster redshift errors, centering errors, and the shape of the NFW profile. These are all smaller than 30% of our reported uncertainty. This work highlights the potential of CMB lensing to enable cosmological constraints from the abundance of distant clusters populating ever larger volumes of the observable universe, beyond the capabilities of optical weak lensing measurements.

Mathew S. Madhavacheril↗

Quantifying Risk to Improve Medical System Design for Long Duration Artemis Missions: A Demonstration of NASA's IMPACT Tradespace Analysis Tool

BACKGROUND NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. A greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the evacuation of ill or injured crew. Mass, volume, and power will be limited while higher demands will be placed on the crews to manage medical events. NASA’s Moon to Mars exploration strategy outlines increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human system risk attributable to medical conditions and use these estimates to advance medical system design. METHODS IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a probabilistic risk assessment (PRA) and tradespace analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; a large increase in the number of medical resources and the flexibility of their use; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to mimic a foundational exploration Artemis mission. The DRM profile includes outbound transit on Orion, Gateway space station rendezvous in lunar orbit, 6 months on the Lunar surface with extravehicular activity (EVA), return rendezvous with Gateway, and transit back to Earth. RESULTS/DISCUSSION: Overall, IMPACT successfully quantified medical risk and derived an optimal medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to medical risk were decompression sickness, trauma, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions and performed as expected. This demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Arian Anderson↗

Development of a Single Level Assessment Module for Simulating the Human Factors Concept Trade Space

This paper is a synopsis of the design and development of the Single Level Assessment Module (SLAM), a habitation mockup aimed at simulating volumetric conditions for astronauts in transit to Mars. Utilizing repurposed materials to enable low cost and constrained by various other design requirements from its parent vehicle, the SLAM embodies a critical step towards understanding human/habitat dynamics and interactions within the framework of the Mars Transit Habitat (TH) concept trade space. The synopsis begins by outlining the design constraints and goals, focusing on material availability and functional area volume requirements. Through various 3D design solutions, the SLAM emerges as a versatile habitat prototype, capable of accommodating various functional areas within its reconfigurable framework. The construction phase is then explored, highlighting the practical challenges and solutions encountered in assembling the SLAM's components. From panel assembly to outfitting functional areas, the construction process demonstrates a methodical approach to realizing the habitat's design intent. Looking ahead, the paper outlines future work, emphasizing the SLAM's adaptability for analysis and its potential to inform the design trade space future habitation concepts across the Moon to Mars architecture. By incorporating hinges for reconfigurability and facilitating volume assessments, the SLAM emerges as a crucial tool in advancing NASA’s ability to assess focused habitation configurations in conjunction with the development of the Moon to Mars architecture. In conclusion, this paper showcases the iterative process of habitat design, from conceptualization to construction.

Keith Lindsey↗

Challenges of Remote Handling in Windowless Hot Cells - 18341

Facilities such as nuclear power stations and neutron sources produce radioactive waste, which must be handled in shielded containment chambers [hot cells]. Traditionally these hot cells are built with lead glass windows to allow direct observation by operators, however, as the complexity and size of handling operations increases, the restrictions imposed by such windows becomes problematic. For the International Thermonuclear Experimental Reactor [ITER] under construction in the South of France and the European Spallation Source [ESS] under construction in Lund, Sweden the hot cell must be capable of processing large, activated and contaminated components, requiring the dexterous tele-manipulation of high dose payloads in the cell. Using lead glass windows would severely restrict the operational envelope within the cell to the volumes directly in front of the windows. This places unreasonable constraints on the types of handling operations that can be carried out. Conversely, a windowless configuration is much more flexible and maximises the operational space for robotic manipulators. Windowless hot cells do however introduce their own challenges. This paper examines the difficulties introduced by lack of direct sight and describes solutions to overcome them. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Postoperative Radiotherapy for Prostate Cancer: A Comparison of Four Consensus Guidelines and Dosimetric Evaluation of 3D-CRT Versus Tomotherapy IMRT

Purpose: Despite the benefits of adjuvant radiotherapy after radical prostatectomy, approximately one-half of patients relapse. Four consensus guidelines have been published (European Organization for Research and Treatment of Cancer, Faculty of Radiation Oncology Genito-Urinary Group, Princess Margaret Hospital, Radiation Therapy Oncology Group) with the aim of standardizing the clinical target volume (CTV) delineation and improve outcomes. To date, no attempt has been made to compare these guidelines in terms of treatment volumes or organ at risk (OAR) irradiation. The extent to which the guideline-derived plans meet the dosimetric constraints of present trials or of the Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) trial is also unknown. Our study also explored the dosimetric benefits of intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients treated with postoperative RT were included. The three-dimensional conformal radiotherapy (3D-CRT) plans were applied to cover the guideline-generated planning target volumes (66 Gy in 33 fractions). Dose-volume histograms (DVHs) were analyzed for CTV/planning target volume coverage and to evaluate OAR irradiation. The OAR DVHs were compared with the constraints proposed in the QUANTEC and Radiotherapy and Androgen Deprivation In Combination After Local Surgery (RADICALS) trials. 3D-CRT plans were compared with the tomotherapy plans for the Radiation Therapy Oncology Group planning target volume to evaluate the advantages of IMRT. Results: The CTV differed significantly between guidelines (p < 0.001). The European Organization for Research and Treatment of Cancer-CTVs were significantly smaller than the other CTVs (p < 0.001). Differences in prostate bed coverage superiorly accounted for the major volumetric differences between the guidelines. Using 3D-CRT, the DVHs rarely met the QUANTEC or RADICALS rectal constraints, independent of the guideline used. The RADICALS bladder constraints were met most often by the European Organization for Research and Treatment of Cancer consensus guideline (14 of 20). The tomotherapy IMRT plans resulted in significant OAR sparing compared with the 3D-CRT plans; however, the RADICALS and QUANTEC criteria were still missed in a large percentage of cases. Conclusion: Treatment volumes using the current consensus guidelines differ significantly. For the four CTV guidelines, the rectal and bladder DVH constraints proposed in the QUANTEC and RADICALS trials are rarely met with 3D-CRT. IMRT results in significant OAR sparing; however, the RADICALS dose constraints are still missed for a large percentage of cases. The rectal and bladder constraints of RADICALS should be modified to avoid a reduction in the CTVs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-BRC-12: Isotoxic Dose Escalation for Advanced Lung Cancer: Comparison of Different Boosting Strategiesfor Patients with Recurrent Disease

Purpose: To determine the dose level and timing of the boost in locally advanced lung cancer patients with confirmed tumor recurrence by comparing different boosting strategies by an impact of dose escalation in improvement of the therapeutic ratio. Methods: We selected eighteen patients with advanced NSCLC and confirmed recurrence. For each patient, a base IMRT plan to 60 Gy prescribed to PTV was created. Then we compared three dose escalation strategies: a uniform escalation to the original PTV, an escalation to a PET-defined target planned sequentially and concurrently. The PET-defined targets were delineated by biologically-weighed regions on a pre-treatment 18F-FDG PET. The maximal achievable dose, without violating the OAR constraints, was identified for each boosting method. The EUD for the target, spinal cord, combined lung, and esophagus was compared for each plan. Results: The average prescribed dose was 70.4±13.9 Gy for the uniform boost, 88.5±15.9 Gy for the sequential boost and 89.1±16.5 Gy for concurrent boost. The size of the boost planning volume was 12.8% (range: 1.4 – 27.9%) of the PTV. The most prescription-limiting dose constraints was the V70 of the esophagus. The EUD within the target increased by 10.6 Gy for the uniform boost, by 31.4 Gy for the sequential boost and by 38.2 for the concurrent boost. The EUD for OARs increased by the following amounts: spinal cord, 3.1 Gy for uniform boost, 2.8 Gy for sequential boost, 5.8 Gy for concurrent boost; combined lung, 1.6 Gy for uniform, 1.1 Gy for sequential, 2.8 Gy for concurrent; esophagus, 4.2 Gy for uniform, 1.3 Gy for sequential, 5.6 Gy for concurrent. Conclusion: Dose escalation to a biologically-weighed gross tumor volume defined on a pre-treatment 18F-FDG PET may provide improved therapeutic ratio without breaching predefined OAR constraints. Sequential boost provides better sparing of OARs as compared with concurrent boost.

60 APPLIED LIFE SCIENCES↗

Glass Composition Constraint Recommendations for Use in Life-Cycle Mission Modeling

The component concentration limits that most influence the predicted Hanford life-cycle HLW glass volume by HTWOS were re-evaluated. It was assumed that additional research and development work in glass formulation and melter testing would be performed to improve the understanding of component effects on the processability and product quality of these HLW glasses. Recommendations were made to better estimate the potential component concentration limits that could be applied today while technology development is underway to best estimate the volume of HLW glass that will eventually be produced at Hanford. The limits for concentrations of P2O5, Bi2O3, and SO3 were evaluated along with the constraint used to avoid nepheline formation in glass. Recommended concentration limits were made based on the current HLW glass property models being used by HTWOS (Vienna et al. 2009). These revised limits are: 1) The current ND should be augmented by the OB limit of OB ≤ 0.575 so that either the normalized silica (NSi) is less that the 62% limit or the OB is below the 0.575 limit. 2) The mass fraction of P2O5 limit should be revised to allow for up to 4.5 wt%, depending on CaO concentrations. 3) A Bi2O3 concentration limit of 7 wt% should be used. 4) The salt accumulation limit of 0.5 wt% SO3 may be increased to 0.6 wt%. Again, these revised limits do not obviate the need for further testing, but make it possible to more accurately predict the impact of that testing on ultimate HLW glass volumes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beams Arrangement in Non-Small Cell Lung Cancer (NSCLC) According to PTV and Dosimetric Parameters Predictive of Pneumonitis

The aim of this study is to propose and validate an original new class of solutions for three-dimensional conformal radiation therapy (3DCRT) treatment planning for non-small cell lung cancer (NSCLC) according to the different patterns of disease presentation (on the basis of tumor location and volume) and to explore beams arrangement (planar or no-planar solutions) to respect dose constraints to the lung parenchyma. Benchmarks matched to validate the new approach are interuser reproducibility and saving on planning time. Tumor location was explored and specific categories created according to the tumor volume and location. Therefore, by applying planar and no-planar 3D plans, we searched for an optimization of the beams arrangement for each category. Dose-volume histograms (DVHs) were analyzed and a plan comparison performed. Results were then validated (class solution planning confirmation) by applying the same strategy to another group of patients. This has been realized at two dose levels (50.4 and 59.4 Gy). Fifty-nine patients were enrolled in this dosimetric study. In the first 27 patients ('exploratory sample') three main planning target volume location categories were identified according to the pattern of the disease presentation: (1) centrally located; (2) peripheral T and mediastinal N (P+N); and (3) superior sulcus. Original class solutions were proposed for each location category. On the next 32 patients ('validation sample'), the treatment planning started directly with the recommended approach. Mean V{sub 20Gy} value was 18.8% (SD {+-} 7.25); mean V{sub 30Gy}:12% (SD {+-} 4.05); and mean lung dose: 11.6Gy (SD {+-} 5.77). No differences between the two total dose level groups were observed. These results suggest a simple and reproducible tool for treatment planning in NSCLC, allowing interuser reproducibility and cutting down on planning time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lagrangian and Dirac constraints for the ideal incompressible fluid and magnetohydrodynamics

The incompressibility constraint for fluid flow was imposed by Lagrange in the so-called Lagrangian variable description using his method of multipliers in the Lagrangian (variational) formulation. An alternative is the imposition of incompressibility in the Eulerian variable description by a generalization of Dirac’s constraint method using noncanonical Poisson brackets. Here it is shown how to impose the incompressibility constraint using Dirac’s method in terms of both the canonical Poisson brackets in the Lagrangian variable description and the noncanonical Poisson brackets in the Eulerian description, allowing for the advection of density. Both cases give the dynamics of infinite-dimensional geodesic flow on the group of volume preserving diffeomorphisms and explicit expressions for this dynamics in terms of the constraints and original variables is given. Since Lagrangian and Eulerian conservation laws are not identical, comparison of the various methods is made.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Primordial non-Gaussianity: Large-scale structure signature in the perturbative bias model

I compute the effect on the power spectrum of tracers of the large-scale mass-density field (e.g., galaxies) of primordial non-Gaussianity of the form {phi}={phi}+f{sub NL}({phi}{sup 2}-<{phi}{sup 2}>)+g{sub NL}{phi}{sup 3}+..., where {phi} is proportional to the initial potential fluctuations and {phi} is a Gaussian field, using beyond-linear-order perturbation theory. I find that the need to eliminate large higher-order corrections necessitates the addition of a new term to the bias model, proportional to {phi}, i.e., {delta}{sub g}=b{sub {delta}}{delta}+b{sub {phi}}f{sub NL}{phi}+..., with all the consequences this implies for clustering statistics, e.g., P{sub gg}(k)=b{sub {delta}}{sup 2}P{sub {delta}}{sub {delta}}(k)+2b{sub {delta}}b{sub {phi}}f{sub NL}P{sub {phi}}{sub {delta}}(k)+b{sub {phi}}{sup 2}f{sub NL}{sup 2}P{sub {phi}}{sub {phi}}(k)+.... This result is consistent with calculations based on a model for dark matter halo clustering, showing that the form is quite general, not requiring assumptions about peaks, or the formation or existence of halos. The halo model plays the same role it does in the usual bias picture, giving a prediction for b{sub {phi}} for galaxies known to sit in a certain type of halo. Previous projections for future constraints based on this effect have been very conservative--there is enough volume at z < or approx. 2 to measure f{sub NL} to {approx}{+-}1, with much more volume at higher z. As a prelude to the bias calculation, I point out that the beyond-linear (in {phi}) corrections to the power spectrum of mass-density perturbations are naively infinite, so it is dangerous to assume they are negligible; however, the infinite part can be removed by a renormalization of the fluctuation amplitude, with the residual k-dependent corrections negligible for models allowed by current constraints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated Analysis of Airport Capacity and Environmental Constraints

LMI conducted an integrated analysis of airport capacity and environmental constraints. identifying and ranking the key factors limiting achievement of NextGen capacity goals. The primary metric used was projected throughput, which was estimated for the years 2015 and 2025 based on the unconstrained demand forecast from the Federal Aviation Administration, and planned improvements including those proposed in the NextGen plan. A set of 310 critical airports was identified.. collectively accounting for more than 99 percent of domestic air traffic volume; a one-off analytical approach was used to isolate the constraint being assessed. The study considered three capacity constraints (runway.. taxiway, and gate) and three environmental constraints (fuel, NO(x) emissions, and noise). For the ten busiest airports, runway and noise are the primary and secondary constraints in both 2015 and 2025. For the OEP 35 airports and overall for the remaining airports, the most binding constraint is noise. Six of the 10 busiest airports, will face runway constraints in 2025, and 95 will face gate constraints. Nearly every airport will be subject to constraints due to emissions and NOx. Runway and taxi constraints are more concentrated in the large airports: environmental constraints are present at almost every airport regardless of size.

Hasan, Shahab↗

Treatment Planning Constraints to Avoid Xerostomia in Head-and-Neck Radiotherapy: An Independent Test of QUANTEC Criteria Using a Prospectively Collected Dataset

Purpose: The severe reduction of salivary function (xerostomia) is a common complication after radiation therapy for head-and-neck cancer. Consequently, guidelines to ensure adequate function based on parotid gland tolerance dose-volume parameters have been suggested by the QUANTEC group and by Ortholan et al. We perform a validation test of these guidelines against a prospectively collected dataset and compared with a previously published dataset. Methods and Materials: Whole-mouth stimulated salivary flow data from 66 head-and-neck cancer patients treated with radiotherapy at the British Columbia Cancer Agency (BCCA) were measured, and treatment planning data were abstracted. Flow measurements were collected from 50 patients at 3 months, and 60 patients at 12-month follow-up. Previously published data from a second institution, Washington University in St. Louis (WUSTL), were used for comparison. A logistic model was used to describe the incidence of Grade 4 xerostomia as a function of the mean dose of the spared parotid gland. The rate of correctly predicting the lack of xerostomia (negative predictive value [NPV]) was computed for both the QUANTEC constraints and Ortholan et al. recommendation to constrain the total volume of both glands receiving more than 40 Gy to less than 33%. Results: Both datasets showed a rate of xerostomia of less than 20% when the mean dose to the least-irradiated parotid gland is kept to less than 20 Gy. Logistic model parameters for the incidence of xerostomia at 12 months after therapy, based on the least-irradiated gland, were D{sub 50} = 32.4 Gy and and {gamma} = 0.97. NPVs for QUANTEC guideline were 94% (BCCA data), and 90% (WUSTL data). For Ortholan et al. guideline NPVs were 85% (BCCA) and 86% (WUSTL). Conclusion: These data confirm that the QUANTEC guideline effectively avoids xerostomia, and this is somewhat more effective than constraints on the volume receiving more than 40 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗