Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VAPOR PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Detection of Inorganic Salt-Based Homemade Explosives (HME) by Atmospheric Flow Tube–Mass Spectrometry

Using a commercial mass spectrometer interfaced with an atmospheric flow tube (AFT) allowed detection of a variety of inorganic compounds used as oxidizers in homemade explosives at picogram levels. The AFT provides reaction times between 3-5 seconds with flows of 6 L/min, enabling detection levels, after thermal desorption, similar to those previously demonstrated for RDX vapors in the low parts-per-quadrillion range. The thermal desorption of chlorate and perchlorate salts resulted in the production of the corresponding anions which have higher electron affinities than the nitrate reactant ions. A dielectric barrier discharge, used as the ionization source, produced the nitrate reactant ions. In some instances, the molecular salt formed adducts with the nitrate, chlorate, and/or perchlorate anions, giving insight into the original identity of the salt cation. Urea nitrate, guanidine nitrate, and potassium nitrate were also detected as adducts with the nitrate reactant ion. Direct room-temperature vapor detection of urea nitrate and hydrogen peroxide, which have relatively high vapor pressures compared to the other salts in this study, is also demonstrated. Room-temperature vapor detection of chlorate and perchlorate salts is possible by the addition of a dilute acid which converts the salt into a more volatile acidic form. A discussion of the instrumentation, methods used, and the ionization chemistry is provided.

chlorate, perchlorate, nitrate, detection, hydroge↗

Determination of the electrical conductivity of liquid Ge(0.95)Si(0.05)

We have measured the electrical conductivity of molten germanium-silicon Ge(0.95)Si(0.05) from the liquidus temperature (1050 C) up to 1220 C. The data were acquired with a unique apparatus which utilizes the standard four-probe technique. The basic unit consists of a fused silica enclosure that contains hermetic glass-to-tungsten seals that can support vacuum pressures down to 10(exp -7) Torr. With calibration, the measurement error for the low vapor pressure materials of this study was typically less than 7%. The temperature dependence of the electrical conductivity of a Ge(0.95)Si(0.05) melt was found to vary from approximately 22,300/ohm/cm at the liquidus temperature down to approximately 16,000/ohm/cm at 1220 C. The negative temperature coefficient as well as the magnitude of these data clearly indicate that the molten material is metallic in nature despite the semiconducting properties of the solid.

Rolin, T. D.↗

Evaluation of Volatile Species in Green Monopropellant Project

NASA is interested in green monopropellants to replace hydrazine in reaction control systems (RCSs). Some current NASA programs require reduced vapor pressure and low toxicity monopropellant (green) and superior performance (specific impulse and density) formulations. Earlier vapor phase studies of a candidate green monopropellant at the NASA White Sands Test Facility (WSTF) showed the presence of a volatile species that warranted further investigation. The purpose of this study was to further characterize the volatile species and to evaluate it. The evaluation was with respect to whether the volatile species was an impurity or how it is formed, and to use that information to examine whether its presence as an impurity can be eliminated during formulation. The evaluation also considered whether formation of the volatile impurity could be prevented while not compromising the propellant. To reduce variables associated with evaluation of the propellant formulation as a whole, a precursor to one of the individual components in the propellant formulation was subjected to a NASA Standard 6001B Flammability, Off-gassing, and Compatibility Requirements and Test Procedures "Determination of Off-gassed Products (Test 7)". Testing took place in the NASA WSTF Molecular Desorption and Analysis Laboratory. One gram of the precursor was placed in a flask within a specimen container. After thermal conditioning for 72 +/- 1 h at 50 +/- 3 deg C (122 +/- 5 deg F), the atmosphere inside the specimen container was analyzed for off-gassed compounds by cryotrap gas chromatography-mass spectrometry (GC-MS) and fixed sample loop GC-flame ionization detection (GC-FID). The specimen container used was glass to minimize potential catalytic surfaces. The identification of compounds was difficult due to the complexity of the vapor phase concentrations and overlapping chromatographic peaks and mass spectra. However, eleven compounds were specifically identified and five compounds or classes of compounds were reported as unidentified. Quantitation of most of the compounds, including unidentified compounds, was as methane. Quantitating compounds or classes of compounds that were detected but for which specific calibration is not established as methane is in accordance with the Test 7 standard protocol. The thermal decomposition temperature of the precursor was significantly higher than the test temperature. Based on thermal decomposition temperature and on an examination of the structure and chemistry of the identified volatile species, the presence of the volatile species appears to be chemically reasonable with respect to the propellant formulation and is at this time attributed to impurities. Further examination of the overall propellant formulation process (including the individual components' synthesis processes) and process quality control (including purity of reagents and possible decomposition reactions) is indicated.

Greene, Benjamin↗

Temperature-dependent complex dielectric permittivity: a simple measurement strategy for liquid-phase samples

Abstract Microwaves (MWs) are an emerging technology for intensified and electrified chemical manufacturing. MW heating is intimately linked to a material’s dielectric permittivity. These properties are highly dependent on temperature and pressure, but such datasets are not readily available due to the limited accessibility of the current methodologies to process-oriented laboratories. We introduce a simple, benchtop approach for producing these datasets near the 2.45 GHz industrial, medical, and scientific (ISM) frequency for liquid samples. By building upon a previously-demonstrated bireentrant microwave measurement cavity, we introduce larger pressure- and temperature-capable vials to deduce temperature-dependent permittivity quickly and accurately for vapor pressures up to 7 bar. Our methodology is validated using literature data, demonstrating broad applicability for materials with dielectric constant ε' ranging from 1 to 100. We provide new permittivity data for water, organic solvents, and hydrochloric acid solutions. Finally, we provide simple fits to our data for easy use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Density-Tape Casting System

Centrifuge packs solids from slurry into uniform, dense layer. New system produces tapes of nearly theoretical packing density. Centrifugal system used to cast thin tapes for capacitors, fuel cells, and filters. Cylindrical rotary casting chamber mounted on high-speed bearings and connected to motor. Liquid for vapor-pressure control and casting slurry introduced from syringes through rotary seal. During drying step, liquid and vapor vented through feed tubes or other openings. Laminated tapes produced by adding more syringes to cast additional layers of different materials.

Collins, Earl R., Jr.↗

In situ observation of irradiation-induced enhancement to the desorption pressure of zirconium hydride in a nuclear reactor

We quantify the effect of a nuclear-reactor environment on the hydrogen isotope equilibrium vapor pressure over pure zirconium and zirconium hydride. A vacuum-sealed capsule containing a zirconium foil with 6 atom% deuterium was irradiated at a neutron flux of ~10 14 cm -2 s -1 at the University of Missouri Research Reactor (MURR). The internal stainless-steel (SS) sample holder acted as the heat source via gamma absorption. To measure low desorption pressures in a high-flux environment, we developed a method to transduce pressure from the measured sample temperature during irradiation, calibrating with known deuterium pressures in unirradiated capsules at various heating powers using an internal filament-heated system designed to mimic irradiation-induced heating. Our temperature-pressure transduction method operates similarly to a Pirani or thermocouple pressure gauge. The in-reactor measurements revealed a roughly 4-fold enhancement in desorption pressure after only 6 h of irradiation (~2 × 10 18 cm -2 neutron fluence) compared to thermal desorption in control experiments, indicating a nonthermal contribution from neutron irradiation. The slower temperature/pressure stabilization rate in the reactor suggests that desorption pressure enhancement increases with neutron fluence. Further, this enhancement signifies increased solubility of hydrogen isotopes in zirconium during irradiation. We propose that high-energy neutron collisions with hydrogen isotopes in hydrides lead to their decomposition at lower temperatures, supersaturating the surrounding αZr lattice and resulting in higher desorption pressure, which continues to rise as more hydrides dissolve with increasing neutron fluence.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pilot-Scale Silicone Process for Low-Cost Carbon Dioxide Capture Preliminary Techno-Economic Analysis

This report presents system and economic analysis for a carbon-capture unit which uses an aminosilicone-based solvent for CO{sub 2} capture in a pulverized coal (PC) boiler. The aminosilicone solvent is a 60/40 wt/wt mixture of 3-aminopropyl end-capped polydimethylsiloxane (GAP-1m) with tri-ethylene glycol (TEG) as a co-solvent. For comparison purposes, the report also shows results for a carbon-capture unit based on a conventional approach using mono-ethanol amine (MEA). The first year removal cost of CO{sub 2} for the aminosilicone-based carbon-capture process is $46.04/ton of CO2 as compared to $60.25/ton of CO{sub 2} when MEA is used. The aminosilicone-based process has <77% of the CAPEX of a system using MEA solvent. The lower CAPEX is due to several factors, including the higher working capacity of the aminosilicone solvent compared the MEA, which reduces the solvent flow rate required, reducing equipment sizes. If it is determined that carbon steel can be used in the rich-lean heat exchanger in the carbon capture unit, the first year removal cost of CO{sub 2} decreases to $44.12/ton. The aminosilicone-based solvent has a higher thermal stability than MEA, allowing desorption to be conducted at higher temperatures and pressures, decreasing the number of compressor stages needed. The aminosilicone-based solvent also has a lower vapor pressure, allowing the desorption to be conducted in a continuous-stirred tank reactor versus a more expensive packed column. The aminosilicone-based solvent has a lower heat capacity, which decreases the heat load on the desorber. In summary, the amino-silicone solvent has significant advantages over conventional systems using MEA.

54 ENVIRONMENTAL SCIENCES↗

Heat-Exchange Fluids for Sulfuric Acid Vaporizers

Some fluorine-substituted organic materials meet criteria for heat-exchange fluids in contact with sulfuric acid. Most promising of these are perfluoropropylene oxide polymers with degree of polymerization (DP) between 10 and 50. It is desirable to have DP in high range because vapor pressure of material decreases as DP increases, and high-DP liquids have lower loss due to vaporization.

Lawson, D. D.↗

Transient Simulation of Pressure Oscillations in the Fuel Feedline of the Fastrac Engine Thrust Chamber

During mainstage testing of the 60,000 lbf thrust Fastrac thrust chamber at MSFC's Test Stand 116 (TS 116), sustained, large amplitude oscillations near 530 Hz were observed in the pressure data. These oscillations were detected both in the RP-1 feedline, downstream of the cavitating venturi, and in the combustion chamber. The driver of the instability is believed to be feedline excitation driven by either periodic cavity collapse at the exit of the cavitating venturi or combustion instability. In covitating venturi, static pressure drops as the flow passes through a constriction resembling a converging-diverging nozzle until the vapor pressure is reached. At the venturi throat, the flow is essentially choked, which is why these devices are typically used for mass flow rate control and disturbance isolation. Typically, a total pressure drop of 15% or more across the venturi is required for cavitation. For much larger pressure differentials, unstable cavities can form and subsequently collapse downstream of the throat. Although the disturbances generated by cavitating venturis is generally considered to be broad-band, this type of phenomena could generate periodic behavior capable of exciting the feedline. An excitation brought about by combustion instability would result from the coupling of a combustion chamber acoustic mode and a feedline resonance frequency. This type of coupling is referred to as "buzz" and is not uncommon for engines in this thrust range.

Bullard, Brad↗

Equation of State for the Thermodynamic Properties of Trans-1,2-dichloroethene [R-1130(E)]

We present an empirical equation of state in terms of the Helmholtz energy for trans-1,2-dichloroethene [R-1130(E)]. The range of validity is from the triple-point temperature, 223.31 K to 525 K with pressures up to 30 MPa. It may be used to calculate all thermodynamic properties in the fluid phase, including liquid, gas, and supercritical regions. Comparisons are given with existing literature data and estimated uncertainties are provided. In addition, checks were made for correct extrapolation behavior so that the equation behaves in a physically realistic manner when used outside of its range of validity, enabling its use in mixture models. The estimated uncertainties (at a k = 2 or 95 % level of confidence) are based on comparisons with critically assessed data and are 0.25 % for vapor pressure for temperatures in the range 300 K < T < 454 K, rising to 1.5 % as the temperature decreases from 300 K to 265 K. For density in the liquid phase the estimated uncertainty is 0.14 % for temperatures 270 K < T < 410 K and for pressures up to 30 MPa. For the vapor phase the estimated uncertainty in density is 3 %. The uncertainty for liquid-phase heat capacity is 1 % at atmospheric pressure over the temperature range 268 K < T < 309 K, and the uncertainty for the speed of sound in the liquid phase is 0.25 % for temperatures 230 K < T < 420 K and for pressures up to 30 MPa. The uncertainties are larger outside of these specified ranges and in the critical region.

1,2-Dichloroethene↗

Nano-Pervaporation Membrane with Heat Exchanger Generates Medical-Grade Water

A nanoporous membrane is used for the pervaporation process in which potable water is maintained, at atmospheric pressure, on the feed side of the membrane. The water enters the non-pervaporation (NPV) membrane device where it is separated into two streams -- retentate water and permeated water. The permeated pure water is removed by applying low vapor pressure on the permeate side to create water vapor before condensation. This permeated water vapor is subsequently condensed by coming in contact with the cool surface of a heat exchanger with heat being recovered through transfer to the feed water stream.

Tsai, Chung-Yi↗

Photochemical trajectory modelling studies of the 1987 Antarctic spring vortex

Simulations of Antarctic ozone photochemistry performed using a photochemical model integrated along air parcel trajectories are described. This type of model has a major advantage at high latitudes of being able to simulate correctly the complex interaction between photolysis and temperature fields, which, because of the polar night cannot be represented accurately in a zonally averaged framework. Isentropic air parcel trajectories were computed using Meteorological Office global model analyses and forecast fields from positions along the ER-2 flight paths during the Airborne Antarctic Ozone Experiment in Austral Spring 1987. A photochemical model is integrated along these trajectories using the aircraft observations to initialize constituent concentrations. The model includes additional reactions of the ClO dimer and also bromine reactions, which are thought to play a significant role in Antarctica. The model also includes heterogeneous reactions which are invoked when the air parcel passes through a polar stratospheric cloud (PSC). The existence of a PSC is determined throughout the course of the model integration from the parcel temperature and the saturated vapour pressure of water over an assumed H2O/HNO3 mixture. The air parcel temperature is used to determine the saturated vapor pressure of HNO3 over the same mixture. Mixing ratios which exceed saturation result in condensation of the excess in the model and hence lead to a reduction of the amount of gas phase NO2 available for chemical reaction.

Austin, J.↗

The distribution of hydrocarbons in Neptune's upper atmosphere

The distribution of hydrocarbons in the upper atmosphere of Neptune is determined on the basis of data from the Voyager UVS solar occultation experiment. Densities are inferred from the transmission properties of the atmosphere measured by the UVS. The CH4 mole fraction in the lower stratosphere is between 0.0006 and 0.005. It is inferred that CH4 in Neptune's lower stratosphere is oversaturated by at least a factor of 10, and possibly by as much as a factor of 100. The density of C2H6 reaches values of 3 x 10 exp 9/cu cm near 100 microbar; a C2H6 production efficiency of 35 +15/-5 percent is derived. The eddy diffusion coefficient is approximately constant at a value of 10,000 sq cm/s at altitudes below 300 km and increases at higher altitudes as the pressure to the 0.75 power. A mole fraction of 0.001 is found to be consistent with the CH4 vapor pressure at 3.4 mbar; consequently, CH4 ice particles must reach this level to produce the inferred oversaturation.

Yelle, Roger V.↗

A Mechanism for Recent Production of Liquid Water on Mars

Though Mars is a cold, dry planet, with respect to the thermal stability of liquid water at low altitudes it is not terribly different from comparably cold places on Earth. In dry air such water would evaporate faster on Mars, at a rate comparable to a 60 C hot spring on Earth, but the heat loss associated with that evaporation would be mitigated by the poor thermal convection in the thin Martian air. Even at higher altitudes where the atmospheric pressure does not reach the triple point of water, liquid water might theoretically exist in a low-vapor pressure form such as wet soil, in a briny solution, or simply under a layer of dust or snow. The theoretical stability of liquid water does not suggest its occurrence, either on Mars or in Antarctica. In fact, global models have suggested that locations capable of providing sufficient heat for melting are, precisely for that reason, too dry for water to be present. However, the temperature of irregular local structures such as trenches or craters can be markedly warmer than those of the uniform surfaces of global models. The work described here suggests a plausible scenario in which seasonal liquid water might be produced locally, in sheltered locations, through a process of condensation, cold-trapping, buffering, and melting. While the amounts produced in the present climate would be small, copious amounts of meltwater may have been produced at other phases of the orbital cycle, as recently as 20,000 years ago.

Hecht, M. H.↗

Measuring Thermodynamic Properties of Metals and Alloys With Knudsen Effusion Mass Spectrometry

This report reviews Knudsen effusion mass spectrometry (KEMS) as it relates to thermodynamic measurements of metals and alloys. First, general aspects are reviewed, with emphasis on the Knudsen-cell vapor source and molecular beam formation, and mass spectrometry issues germane to this type of instrument are discussed briefly. The relationship between the vapor pressure inside the effusion cell and the measured ion intensity is the key to KEMS and is derived in detail. Then common methods used to determine thermodynamic quantities with KEMS are discussed. Enthalpies of vaporization, the fundamental measurement, are determined from the variation of relative partial pressure with temperature using the second-law method or by calculating a free energy of formation and subtracting the entropy contribution using the third-law method. For single-cell KEMS instruments, measurements can be used to determine the partial Gibbs free energy if the sensitivity factor remains constant over multiple experiments. The ion-current ratio method and dimer-monomer method are also viable in some systems. For a multiple-cell KEMS instrument, activities are obtained by direct comparison with a suitable component reference state or a secondary standard. Internal checks for correct instrument operation and general procedural guidelines also are discussed. Finally, general comments are made about future directions in measuring alloy thermodynamics with KEMS.

Copland, Evan H.↗