Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Apparatus for disintegrating kidney stones

The useful life of the wire probe in an ultrasonic kidney stone disintegration instrument is enhanced and prolonged by attaching the wire of the wire probe to the tip of an ultrasonic transducer by means of a clamping arrangement. Additionally, damping material is applied to the wire probe in the form of a damper tube through which the wire probe passes in the region adjacent the transducer tip. The damper tube extends outwardly from the transducer tip a predetermined distance, terminating in a resilient soft rubber joint. Also, the damper tube is supported intermediate its length by a support member. The damper system thus acts to inhibit lateral vibrations of the wire in the region of the transducer tip while providing little or no damping to the linear vibrations imparted to the wire by the transducer.

Angulo, E. D.↗

Impact dynamics instrumentation

One of the tasks specified in the NASA Langley controlled impact demonstration (CID) work package was to furnish dynamic instrumentation sensors. The types of instrumentation sensors required were accelerometers for aircraft structural loads measurements, seat belt load cells to measure anthropomorphic dummy responses to the aircraft impact, and strain gage bending bridges to measure the aircraft fuselage and wing bending during impact. The objective in the selection of dynamic instrumentation for the CID was to provide 352 of the highest quality transducers and remain within budget allocation. The transducers that were selected for the CID evaluation process were each subjected to rigorous laboratory acceptance tests and to aircraft fuselage section drop tests at the LaRC Impact Dynamics Research Facility. Data compiled from this series of tests showed the selected transducers to be best suited for the CID mission requirement. The transducers installation technique on the airframe proved successful. The transducer quality assurance was guaranteed through rigorous acceptance testing. Data acquired was 97.0%.

Mccormck, R. F.↗

Ultrasonic depth gauge for liquids under high pressure

An ultrasonic depth gauge 20 for liquids under high pressure is comprised of a transducer assembly 21 and a supporting electronics unit 22. The transducer assembly is mounted into the bottom wall of a storage vessel 12 with its resonating surface directly exposed to the highly pressurized liquid 13 in the vessel. The transducer assembly consists of a conventional transducer element 38 rigidly bonded to the inside wall of a bored out conventional high-pressure plug 30 thereby forming a composite resonator 50. The element and the plug wall resonate as one upon electrical excitation of the element while the transducer element is completely shielded from any exposure to the liquid under high pressure. The composite resonator sends a vibration up to the surface of the liquid where it is reflected back to the composite resonator. The supporting electronics unit measures the vibrations round-trip transit time which is proportional to the depth 15 of the liquid.

Allan J Zuckerwar↗

Liquid metal drop ejection

The aim of this project was to demonstrate the possibility of ejecting liquid metals using drop on demand printing technology. The plan was to make transducers for operation in the 100 MHz frequency range and to use these transducers to demonstrate the ability to eject drops of liquid metals such as gallium. Two transducers were made by indium bonding piezoelectric lithium niobate to quartz buffer rods. The lithium niobate plates were thinned by mechanical polishing to a thickness of 37 microns for operation at 100 MHz. Hemispherical lenses were polished in the opposite ends of the buffer rods. The lenses, which focus the sound waves in the liquid metal, had an F-number equals 1. A mechanical housing was made to hold the transducers and to allow precise control over the liquid level above the lens. We started by demonstrating the ability to eject drops of water on demand. The drops of water had a diameter of 15 microns which corresponds to the wavelength of the sound wave in the water. A videotape of this ejection was made. We then used a mixture of Gallium and Indium (used to lower the melting temperature of the Gallium) to demonstrate the ejection of liquid metal drops. This proved to be difficult because of the oxide skin which forms on the surface of the liquid. In some instances, we were able to eject metal drops, however, this was not consistent and reproducible. An experiment was set up at NASA-Lewis to stabilize the process of drop on demand liquid metal ejection. The object was to place the transducer and liquid metal in a vacuum station so that no oxide would form on the surface. We were successful in demonstrating that liquid metals could be ejected on demand and that this technology could be used for making sheet metal in space.

Khuri-Yakub, B. T.↗

Inducer Hydrodynamic Load Measurement Devices

Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher-frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

Skelley, Stephen E.↗

Inducer Hydrodynamic Load Measurement Devices

Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

Skelley, Stephen E.↗

Piezoelectric Shunt Vibration Damping of F-15 Panel under High Acoustic Excitation

At last year's SPIE symposium, we reported results of an experiment on structural vibration damping of an F-15 underbelly panel using piezoelectric shunting with five bonded PZT transducers. The panel vibration was induced with an acoustic speaker at an overall sound pressure level (OASPL) of about 90 dB. Amplitude reductions of 13.45 and 10.72 dB were achieved for the first and second modes, respectively, using single- and multiple-mode shunting. It is the purpose of this investigation to extend the passive piezoelectric shunt-damping technique to control structural vibration induced at higher acoustic excitation levels, and to examine the controllability and survivability of the bonded PZT transducers at these high levels. The shunting experiment was performed with the Thermal Acoustic Fatigue Apparatus (TAFA) at the NASA Langley Research Center using the same F-15 underbelly panel. The TAFA is a progressive wave tube facility. The panel was mounted in one wall of the TAFA test section using a specially designed mounting fixture such that the panel was subjected to grazing-incidence acoustic excitation. Five PZT transducers were used with two shunt circuits designed to control the first and second modes of the structure between 200 and 400 Hz. We first determined the values of the shunt inductance and resistance at an OASPL of 130 dB. These values were maintained while we gradually increased the OASPL from 130 to 154 dB in 6-dB steps. During each increment, the frequency response function between accelerometers on the panel and the acoustic excitation measured by microphones, before and after shunting, were recorded. Good response reduction was observed up to the 148dB level. The experiment was stopped at 154 dB due to wire breakage from vibration at a transducer wire joint. The PZT transducers, however, were still bonded well on the panel and survived at this high dB level. We also observed shifting of the frequency peaks toward lower frequency when the OASPL was increased. Detailed experimental results will be presented.

Wu, Shu-Yau↗

Automated Guided-Wave Scanning Developed to Characterize Materials and Detect Defects

The Nondestructive Evaluation (NDE) Group of the Optical Instrumentation Technology Branch at the NASA Glenn Research Center has developed a scanning system that uses guided waves to characterize materials and detect defects. The technique uses two ultrasonic transducers to interrogate the condition of a material. The sending transducer introduces an ultrasonic pulse at a point on the surface of the specimen, and the receiving transducer detects the signal after it has passed through the material. The aim of the method is to correlate certain parameters in both the time and frequency domains of the detected waveform to characteristics of the material between the two transducers. The scanning system is shown. The waveform parameters of interest include the attenuation due to internal damping, waveform shape parameters, and frequency shifts due to material changes. For the most part, guided waves are used to gauge the damage state and defect growth of materials subjected to various mechanical or environmental loads. The technique has been applied to polymer matrix composites, ceramic matrix composites, and metal matrix composites as well as metallic alloys. Historically, guided wave analysis has been a point-by-point, manual technique with waveforms collected at discrete locations and postprocessed. Data collection and analysis of this type limits the amount of detail that can be obtained. Also, the manual movement of the sensors is prone to user error and is time consuming. The development of an automated guided-wave scanning system has allowed the method to be applied to a wide variety of materials in a consistent, repeatable manner. Experimental studies have been conducted to determine the repeatability of the system as well as compare the results obtained using more traditional NDE methods. The following screen capture shows guided-wave scan results for a ceramic matrix composite plate, including images for each of nine calculated parameters. The system can display up to 18 different wave parameters. Multiple scans of the test specimen demonstrated excellent repeatability in the measurement of all the guided-wave parameters, far exceeding the traditional point-by-point technique. In addition, the scan was able to detect a subsurface defect that was confirmed using flash thermography This technology is being further refined to provide a more robust and efficient software environment. Future hardware upgrades will allow for multiple receiving transducers and the ability to scan more complex surfaces. This work supports composite materials development and testing under the Ultra-Efficient Engine Technology (UEET) Project, but it also will be applied to other material systems under development for a wide range of applications.

Martin, Richard E.↗

Damage Assessment of Creep Tested and Thermally Aged Metallic Alloys Using Acousto-Ultrasonics

In recent years emphasis has been placed on the early detection of material changes experienced in turbine powerplant components. During the scheduled overhaul of a turbine, the current techniques of examination of various hot section components aim to find flaws such as cracks, wear, and erosion, as well as excessive deformations. Thus far, these localized damage modes have been detected with satisfactory results. However, the techniques used to find these flaws provide no information on life until the flaws are actually detected. Major improvements in damage assessment, safety, as well as more accurate life prediction could be achieved if nondestructive evaluation (NDE) techniques could be utilized to sense material changes that occur prior to the localized defects mentioned. Because of elevated temperatures and excessive stresses, turbine components may experience creep behavior. As a result, it is desirable to monitor and access the current condition of such components. Research at the NASA Glenn Research Center involves developing and utilizing an NDE technique that discloses distributed material changes that occur prior to the localized damage detected by the current methods of inspection. In a recent study, creep processes in a nickel-base alloy were the life-limiting condition of interest, and the NDE technique was acousto-ultrasonics (AU). AU is an NDE technique that utilizes two ultrasonic transducers to interrogate the condition of a test specimen. The sending transducer introduces an ultrasonic pulse at a point on the surface of the specimen while a receiving transducer detects the signal after it has passed through the material. The goal of the method is to correlate certain parameters of the detected waveform to characteristics of the material between the two transducers. Here, the waveform parameter of interest is the attenuation due to internal damping for which information is being garnered from the frequency domain. The parameters utilized to indirectly quantify the attenuation are the ultrasonic decay rate as well as various moments of the frequency power spectrum. A new, user-friendly, graphical interface AU system was developed at NASA Glenn. This system is an all-inclusive, multifunction system that controls the sending and receiving ultrasonic transducers as well as all posttest signal analysis. The system's postprocessing software calculates the multiple parameters used to study the material of interest.

Gyekenyesi, Andrew L.↗

Low-Pressure Generator Makes Cleanrooms Cleaner

Scientists at NASA's Kennedy Space Center work in cleanrooms: laboratories with high degrees of cleanliness provided by strict control of particles such as dust, lint, or human skin. They are contaminant-free facilities, where the air is repeatedly filtered, and surfaces are smooth to prevent particles from getting lodged. Technicians working in these environments wear specially designed cleanroom "bunny suits" and booties over their street clothes, as well as gloves and face masks to avoid any contamination that may be imparted from the outside world. Even normal paper is not allowed in cleanrooms, only cleanroom low-particulate paper. These are sensitive environments where precision work, like the production of silicon chips or hard disk drives, is performed. Often in cleanrooms, positive air pressure is used to force particles outside of the isolated area. The air pressure in the Kennedy cleanrooms is monitored using high-accuracy, low-differential pressure transducers that require periodic calibration. Calibration of the transducers is a tricky business. In prior years, the analysis was performed by sending the transducers to the Kennedy Standards Laboratory, where a very expensive cross-floated, labor- intensive, dead-weight test was conducted. In the early 1990s, scientists at Kennedy determined to develop a technique and find equipment to perform qualification testing on new low-differential pressure transducers in an accurate, cost-effective manner onsite, without requiring an environmentally controlled room. They decided to use the highly accurate, cost-effective Setra Model C264 as the test transducer. For qualification testing of the Setra, though, a portable, lower-cost calibrator was needed that could control the differential pressure to a high degree of resolution and transfer the accuracy of the Standards Laboratory testing to the qualification testing. The researchers decided that, to generate the low-differential pressure setpoints needed for qualification testing, very small gas volume changes could be made against the test article, and a corresponding pressure change would be detected by a pressure standard. This allowed the researchers to recreate cleanroom air pressure settings without the use of a cleanroom. Thus was born the low-differential pressure generator. In 1993, a prototype was developed using a pair of PVC tanks, a volume controller, and a 1-pound-per-square-inch pressure standard. By 1995, the prototype was perfected into the unit that is still used today.

Source record↗

Sensor tip for a robotic gripper and method of manufacture

A sensor tip (10) for use in a robotic hand has a three-dimensional compliant elastomeric body (12) with an outer boundary (22) having a circular base (24) and a convex surface (26) extending therefrom. Four strain transducers (14, 16, 18, and 20) produce electrical signals indicative of the strain at various positions near the boundary of the elastomeric body (12) resulting from forces exerted upon the sensor tip (10) by an object which the robotic hand is manipulating. The transducers (14, 16, 18, and 20) are positioned about the convex surface (26) so as to produce signals that may be decoupled to determine the normal and tangential forces and the applied torque. A buffer amplifier circuit (34), one for each of the transducers (14, 16, 18, and 20), receives the signals and provides quasi-steady state force information. The circuit (34) connects the respective transducer (40) in a feedback loop around an amplifier (36) and has desirable attributes for static charge buffering. The sensor tip (10) is calibrated to determine proportionality constants for the decoupling algorithm for use of a force delivering system (60), which uses voice coils (74) to apply a force that is linearly related to the current introduced to each of the coils (74). A method of manufacture of the sensor tip (10) results in improved bonding between the transducers (14, 16, 18, and 20) and the elastomeric body (12) for better performance and longer life of the sensor tip (10).

Lorenz, Robert D.↗

Sensor tip for a robotic gripper and method of manufacture

A sensor tip (10) for use in a robotic hand has a three-dimensional compliant elastomeric body (12) with an outer boundary (22) having a circular base (24) and a convex surface (26) extending therefrom. Four strain transducers (14, 16, 18, and 20) produce electrical signals indicative of the strain at various positions near the boundary of the elastomeric body (12) resulting from forces exerted upon the sensor tip (10) by an object which the robotic hand is manipulating. The transducers (14, 16, 18, and 20) are positioned about the convex surface (26) so as to produce signals that may be decoupled to determine the normal and tangential forces and the applied torque. A buffer amplifier circuit (34), one for each of the transducers (14, 16, 18, and 20), receives the signals and provides quasi-steady state force information. The circuit (34) connects the respective transducer (40) in a feedback loop around an amplifier (36) and has desirable attributes for static charge buffering. The sensor tip (10) is calibrated to determine proportionality constants for the decoupling algorithm for use of a force delivering system (60), which uses voice coils (74) to apply a force that is linearly related to the current introduced to each of the coils (74). A method of manufacture of the sensor tip (10) results in improved bonding between the transducers (14, 16, 18, and 20) and the elastomeric body (12) for better performance and longer life of the sensor tip (10).

Lorenz, Robert D.↗

Adaptive Pressure Profile Method to Locate the Isolator Shock Train Leading Edge Given Limited Pressure Information

To maximize the performance of high-speed air-breathing engines, such as dual-mode scramjets, the streamwise location of the shock train leading edge (STLE) is ideally placed as far upstream in the isolator as possible while avoiding engine unstart. Thus, it is of interest to quantify and control the STLE location as the vehicle travels along its flight trajectory. The STLE location is typically quantified using wall static pressure measurements but there are often restrictions on the number and placement of transducers, thus reducing the accuracy and overall capability of STLE detection methods. In this work, the Adaptive Pressure Profile (APP) method is introduced to address such sparsity concerns. This method is data driven and does not heavily rely on prior information about the flow regime or engine model. Instead, the \mname method uses real-time pressure measurements from a small number of transducers to adaptively learn the isolator pressure profile. This adaptively-learned profile is fit to the pressure data at each time instance to estimate STLE location. The \mname method produces accurate estimates even when (1) the STLE location is not bounded by two or more transducers or (2) when the STLE location is between two transducers that are situated several duct heights apart. Data from two direct-connect isolator models are used to evaluate the accuracy of the \mname method and demonstrate its robustness for different back-pressure scenarios and transducer configurations.

Robin L Hunt↗

Adaptive Pressure Profile Method to Locate the Isolator Shock Train Leading Edge Given Limited Pressure Information

To maximize the performance of high-speed air-breathing engines, such as dual-mode scramjets, the streamwise location of the shock train leading edge (STLE) is ideally placed as far upstream in the isolator as possible while avoiding engine unstart. Thus, it is of interest to quantify and control the STLE location as the vehicle travels along its flight trajectory. The STLE location is typically quantified using wall static pressure measurements but there are often restrictions on the number and placement of transducers, thus reducing the accuracy and overall capability of STLE detection methods. In this work, the Adaptive Pressure Profile (APP) method is introduced to address such sparsity concerns. This method is data driven and does not heavily rely on prior information about the flow regime or engine model. Instead, the \mname method uses real-time pressure measurements from a small number of transducers to adaptively learn the isolator pressure profile. This adaptively-learned profile is fit to the pressure data at each time instance to estimate STLE location. The \mname method produces accurate estimates even when (1) the STLE location is not bounded by two or more transducers or (2) when the STLE location is between two transducers that are situated several duct heights apart. Data from two direct-connect isolator models are used to evaluate the accuracy of the \mname method and demonstrate its robustness for different back-pressure scenarios and transducer configurations.

Robin Hunt↗

Ultrasonic sensors and methods of using the ultrasonic sensors

An ultrasonic sensor comprises a transducer in operable communication with a power source, a waveguide comprising a metal and at least one of a fissile material or a fertile material in operable communication with the transducer and configured to propagate and reflect acoustic waves generated by the transducer, the transducer configured to convert reflected acoustic waves to an electric signal, a thermally insulative material proximate the waveguide, and a control system in operable communication with the transducer, the control system configured to determine at least a temperature of the waveguide based on the reflected acoustic waves. Related methods are also disclosed.

Woolstenhulme, Nicolas E.↗

Multiphysics modeling of printed surface acoustic wave thermometers

Surface acoustic wave (SAW) transducers are a class of sensors and actuators that operate on the fundamental principle of piezoelectricity. Aerosol jet printing and other additive manufacturing techniques have resulted in the low-cost fabrication of low-power and small-footprint SAW devices that are suitable for sensing in high-temperature and radioactive environments. In this work, we developed a series of temperature-dependent finite element models for a SAW transducer consisting of printed silver interdigitated transducers (IDTs) deposited onto piezoelectric lithium niobate. Modeling accuracy was evaluated experimentally from room temperature to 200 °C using an aerosol-jet-printed SAW thermometer. A time-domain study enabled visualization of the wave propagation and successfully guided the denoising of the scattering parameter measurement. Additionally, frequency-domain models using traditional modal analysis or the unique port boundary condition feature in COMSOL Multiphysics accurately predicted the temperature-driven natural frequency drift in the SAW thermometer. The finite element models developed in this study serve to facilitate the computer-aided design of future SAW transducers for applications in harsh environments.

47 OTHER INSTRUMENTATION↗

A 1-km photonic link connecting superconducting circuits in two dilution refrigerators

Superconducting quantum processors are a leading platform for implementing practical quantum computation algorithms. Although superconducting quantum processors with hundreds of qubits have been demonstrated, their further scale-up is constrained by the physical size and cooling power of dilution refrigerators. This constraint can be overcome by constructing a quantum network to interconnect qubits hosted in different refrigerators, which requires microwave-to-optical transducers to enable low-loss signal transmission over long distances. Although various designs and demonstrations have achieved high-efficiency and low-added-noise transducers, a coherent photonic link between separate refrigerators has not yet been realized. Here, in this work, we experimentally demonstrate coherent signal transfer between two superconducting circuits housed in separate dilution refrigerators, enabled by a pair of frequency-matched aluminium nitride electro-optic transducers connected via a 1-km telecom optical fibre. The optical frequency matching between two transducers is realized by an asymmetric photonic molecule design, and an overall 80 dB improvement in transduction efficiency over commercial electro-optic modulators is achieved, paving the way towards a fully quantum-enabled link. This work provides critical design guidelines for scalable superconducting quantum networks interconnected by photonic links.

nonlinear optics↗

Transducerless time domain reflectance measurement of semiconductor thermal properties

The dominant techniques for laser-based thermal measurement, time-domain thermoreflectance (TDTR) and frequency-domain thermoreflectance, generally require that samples be coated with a metal transducer layer. The properties of the transducer and its interface to the sample are then important to the interpretation of results, and heat conduction in the transducer layer can limit measurements of ultra-thin samples or in-plane conductivity. Here, we demonstrate the feasibility of measuring semiconductor samples using standard TDTR instrumentation, without the use of a metal transducer. A mathematical model accounting for non-zero laser penetration depth as well as both thermal and charge carrier effects is presented, and the ability of the model to describe and fit to experimental data for silicon and germanium samples is demonstrated. Though at this stage measurement uncertainties are larger than for traditional TDTR, we anticipate that the use of this technique will expand the range of samples that can be measured with existing TDTR setups.

36 MATERIALS SCIENCE↗