Rapid Analysis of Ingredients in Cream Using Ultrasonic Mist–Direct Analysis in Real-Time Time-of-Flight Mass Spectrometry

A novel method for the simultaneous detection of ingredients in pharmaceutical applications such as creams and lotions was developed. An ultrasonic atomizer has been used to produce a mist containing ingredients. The analyte molecules in the mist can be ionized by using direct analysis in real time (DART) at lower temperature than traditionally used, and we thus solved the problem of normal DART-MS measurement using a high-temperature gas. Thereby, molecular-related ions of heat-unstable components and nonvolatile components became detectable. The deprotonated molecular ion of glycyrrhizic acid (m/z 821), which is unstable at high temperatures, was detected without pyrolysis by ultrasonic mist–DART-MS using unheated helium gas, although it was not detected by normal DART-MS using heated helium gas. The cationized molecular ions of derivatives of polyethylene glycol fatty acid monoesters, which are nonvolatile compounds, were also detected as m/z peaks observed from 800 to 2300. Although the protonated molecular ion of tocopherol acetate was not detected in ionization by ultrasonic mist, it was detected by ultrasonic mist–DART-MS even in the emulsion. It was not necessary to dissolve a sample completely to detect its ions. This method enabled us to obtain the composition of pharmaceutical applications simply and rapidly. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Sequenced Flow Field Prediction in an Optima Spark-Ignition Direct-Injection Engine Using Bidirectional Recurrent Neural Network (bi-RNN) with Long Short-Term Memory

To further improve the energy conversion efficiency of internal combustion engine, the transient and complex air flow movement inside the cylinder needs to be better understood and controlled. Although the in-cylinder flow fields are highly stochastic with strong cycle-to-cycle fluctuations, machine learning can still provide an efficient way to learn and regress the complex flow movement process inside the cylinder. In this work, a bidirectional recurrent neural network (bi-RNN) model with long short-term memory was applied to predict the in-cylinder flow fields at different time steps using training data from mull-cycle particle image velocimetry (PIV) measurements. To evaluate the agreement between the true and predicted flow fields, structure and magnitude comparison indices are calculated both globally and locally. The comparison results show that the bi-RNN model can accurately predict the bulk flow and vortex motions from early intake stroke to compression stroke. This work demonstrates that the machine learning model has the potential to predict the underlying dynamics of the interaction between in-cylinder flows and provides a reliable way to improve temporal resolution in PIV flow data to better reveal transient in-cylinder flow features.

Bi-RNN model↗

Development of a new ion mobility time-of-flight mass spectrometer

Complex samples require multidimensional measurements with high resolution for full characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometry (IMS-Orbitrap MS) platform. To circumvent the timing difference between the fast IMS separation and the slow Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequence to multiplex ions into the drift tube and Orbitrap. The instrument was designed to operate in signal averaging (SA), single multiplexing (SM) and double multiplexing (DM) IMS modes to fully optimize the signal-to-ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data, while a new algorithm was developed for the DM analyses. The new algorithm is a two-step process that first recovers the SM data from the encoded DM data and then decoded the SM data. The algorithm also performs multiple refining procedures in order to minimize the demultiplexing artifacts traditionally observed in such scheme. The new IMS-Orbitrap MS platform was demonstrated for the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulae.

47 OTHER INSTRUMENTATION↗

Application of atomic layer deposited microchannel plates to imaging photodetectors with high time resolution

Novel microchannel plates have been constructed using borosilicate glass micro-capillary array substrates with 20 mu m and 10 mu m pores and coated with resistive, and secondary electron emissive, layers by atomic layer deposition. Microchannel plates in 33 mm, 50 mm and 20 cm square formats have been made and tested. Although their amplification, imaging, and timing properties are comparable to standard glass microchannel plates, the background rates and lifetime characteristics are considerably improved. Sealed tube detectors based on the Planacon tube, and a 25 mm cross delay line readout tube with a GaN(Mg) opaque photocathode deposited on borosilicate microchannel plates have been fabricated. Considerable progress has also been made with 20 cm microchannel plates for a 20 cm format sealed tube sensor with strip-line readout that is being developed for Cherenkov light detection.

Siegmund, O. H. W.↗

Orientational Pair Correlations in a Dipolar Molecular Liquid: Time-Resolved Resonant and Nonresonant Pump–Probe Spectroscopies

Orientational pair correlations (OPCs), when they are sufficiently strong in a liquid, contain information on the interplay between structure and dynamics that arise from intermolecular interactions. Consequently, the quantification of OPCs remains a subject of substantial interest in current experimental and theoretical work. In the case of benzonitrile, the importance of OPCs remains ambiguous owing to the use of model-dependent analyses or reliance on a single spectroscopic technique. In this work, IR polarization selective pump-probe (PSPP) and optical heterodyne-detected optical Kerr effect (OHD-OKE) experiments were used to quantify OPCs in benzonitrile. These methods measure single molecule and collective relaxation, respectively. Comparison of the orientational correlation function (PSPP) of the naturally abundant 13CN stretching mode and the polarizability anisotropy relaxation (OHD-OKE) of the liquid revealed that collective reorientation was a factor of 1.56 ± 0.08 slower than the single molecule reorientation time. The two types of measurements on dilute benzonitrile in carbon tetrachloride were the same within experimental error. These results support the proposition that OPCs exist and arise from the formation of parallel-aligned intermolecular structures in the neat liquid.

14 SOLAR ENERGY↗

Entangled Photon Correlations Allow a Continuous-Wave Laser Diode to Measure Single-Photon, Time-Resolved Fluorescence

Fluorescence lifetime experiments are a standard approach for measuring excited state dynamics and local environment effects. Here, we show that entangled photon pairs produced from a continuous-wave (CW) laser diode can replicate pulsed laser experiments without phase modulation. As a proof of principle, picosecond fluorescence lifetimes of indocyanine green are measured in multiple environments. Here, the use of entangled photons has three unique advantages. First, low power CW laser diodes and entangled photon source design lead to straightforward on-chip integration for a direct path to distributable fluorescence lifetime measurements. Second, the entangled pair wavelength is easily tuned by temperature or electric field, allowing a single source to cover octave bandwidths. Third, femtosecond temporal resolutions can be reached without requiring major advances in source technology or external phase modulation. Entangled photons could therefore provide increased accessibility to time-resolved fluorescence while also opening new scientific avenues in photosensitive and inherently quantum systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Bottom-Up Formation Mechanism of Solid Electrolyte Interphase Revealed by Isotope-Assisted Time-of-Flight Secondary Ion Mass Spectrometry

Understanding the solid electrolyte interphase (SEI) formation mechanism is critically important for the performance and durability of lithium-ion batteries. However, the details of how SEI builds up into a nanometer-thick layer from molecular level reduction reactions on negative electrodes are missing. Here, isotope-assisted time-of-flight secondary ion mass spectrometry analyses were designed to answer this fundamental question. By investigating the isotope ratio profile in SEI during the initial SEI formation cycle, it is discovered that the topmost SEI near the electrolyte formed first and the SEI near the electrode formed later. Furthermore, this new “bottom-up” SEI growth mechanism was then correlated to the electrolyte one-electron and two-electron reduction reaction dynamics, which in turn explains the formation of the two-layered organic–inorganic SEI composite structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗