Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Maximizing long-term biohydrogen production with Clostridium thermocellum for high solids conversion of lignocellulosic biomass

Biological hydrogen production from lignocellulosic biomass sustainably couples organic waste reduction with renewable energy generation. Efficient conversion is challenged by the structural complexity of lignocellulose and resulting recalcitrance to enzymatic degradation. Clostridium thermocellum natively breaks down biomass with highly effective hemi-/cellulases systems (i.e., cellulosomes) and generates hydrogen in anaerobic cultivation, creating a compelling platform for lignocellulosic biohydrogen production. Achieving commercially viable production rates requires balancing high biomass loading and throughput against uniform mixing conditions required for enzyme dispersion, pH and temperature control, and efficient hydrogen and metabolite removal in continuous operation. To address these barriers to process intensification, we implemented novel reactor and process designs for high-solids lignocellulosic biomass fermentations using the C. thermocellum KJC19-9 strain, genetically engineered for co-utilization of cellulose and hemicellulose sugars (i.e., xylose). Via computational fluid dynamics (CFD) modeling and experimental validation, we achieved a >50% improvement in biohydrogen production with an improved anchor-type impeller morphology, coupled to a threefold reduction in agitation rate. To further reduce rheological constraints and accumulation of toxic metabolites, we then transitioned the process to sequencing fed-batch operation. The resulting process generated 24.87 L H 2 L −1 from 160 g L −1 of deacetylated and mechanically refined (DMR)-pretreated corn stover biomass over 16 days while solubilizing >95% of influent cellulose and hemicellulose, setting a new performance benchmark for continuous production of biohydrogen from lignocellulose.

08 HYDROGEN↗

Multipoint Thomson scattering diagnostic for the Madison Symmetric Torus reversed-field pinch

The multipoint Thomson scattering diagnostic on the Madison Symmetric Torus (MST) is now fully operational with 21 spatial points, which cover the entire minor radius. Four full electron temperature profiles can be obtained during each MST discharge, with a variable delay between each profile. This system overcomes challenges that arise from the unique machine design, location, and plasma characteristics of MST. The machine design limits the maximum porthole diameter to 11.4 cm, requiring a compact, re-entrant, seven element lens for scattered light collection. Limited space near MST necessitates a long beam path for the two Nd:YAG lasers requiring a remote beam line adjustment system to suppress drift in the beam position due to thermal expansion of the building. Due to the remote location of the laser head, substantial design effort was put into the creation of a set of safety interlocks for the laser system. The dynamic nature of MST plasmas and the wide range of operating space require a versatile scattered light detection system consisting of filter polychromators with temperature controlled avalanche photodiode detectors. We also implement an insertable integrating sphere, which travels along the laser beam path through the vacuum vessel, for the alignment of both the fiber optics and the lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of plasma-generated negative oxygen ion impingement on magnetron sputtered amorphous SiO{sub 2} thin films during growth at low temperatures

Growth of amorphous SiO{sub 2} thin films deposited by reactive magnetron sputtering at low temperatures has been studied under different oxygen partial pressure conditions. Film microstructures varied from coalescent vertical column-like to homogeneous compact microstructures, possessing all similar refractive indexes. A discussion on the process responsible for the different microstructures is carried out focusing on the influence of (i) the surface shadowing mechanism, (ii) the positive ion impingement on the film, and (iii) the negative ion impingement. We conclude that only the trend followed by the latter and, in particular, the impingement of O{sup -} ions with kinetic energies between 20 and 200 eV, agrees with the resulting microstructural changes. Overall, it is also demonstrated that there are two main microstructuring regimes in the growth of amorphous SiO{sub 2} thin films by magnetron sputtering at low temperatures, controlled by the amount of O{sub 2} in the deposition reactor, which stem from the competition between surface shadowing and ion-induced adatom surface mobility.

36 MATERIALS SCIENCE↗

DEIMOS: A beamline dedicated to dichroism measurements in the 350–2500 eV energy range

The DEIMOS (Dichroism Experimental Installation for Magneto-Optical Spectroscopy) beamline was part of the second phase of the beamline development at French Synchrotron SOLEIL (Source Optimisée de Lumière à Energie Intermédiaire du LURE) and opened to users in March 2011. It delivers polarized soft x-rays to perform x-ray absorption spectroscopy, x-ray magnetic circular dichroism, and x-ray linear dichroism in the energy range 350–2500 eV. The beamline has been optimized for stability and reproducibility in terms of photon flux and photon energy. The main end-station consists in a cryo-magnet with 2 split coils providing a 7 T magnetic field along the beam or 2 T perpendicular to the beam with a controllable temperature on the sample from 370 K down to 1.5 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution photoelectron imaging of cold C{sub 60}{sup −} anions and accurate determination of the electron affinity of C{sub 60}

High-resolution photoelectron imaging and spectroscopy of cold C{sub 60}{sup −} anions are reported using a newly built photoelectron imaging apparatus coupled with an electrospray ionization source and a temperature-controlled cryogenic ion trap. Vibrationally resolved photoelectron spectra are obtained for the detachment transition from the ground state of C{sub 60}{sup −} to that of C{sub 60} at various detachment wavelengths from 354.84 nm to 461.35 nm. The electron affinity of C{sub 60} is accurately measured to be 2.6835 ± 0.0006 eV. Numerous unexpected vibrational excitations are observed in the photoelectron spectra due to the Jahn-Teller effect in C{sub 60}{sup −} and Hertzberg-Teller vibronic coupling in both C{sub 60}{sup −} and C{sub 60}. Both the relative intensities of vibrational peaks and their photoelectron angular distributions provide evidence for the vibronic couplings. The observed p-wave-like behavior in the angular distribution of the 0{sub 0}{sup 0} transition suggests that the electron is detached from an s-type orbital.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-property characterization chamber for geophysical-hydrological investigations of hydrate bearing sediments

With the increase in the interest of producing natural gas from methane hydrates as well as potential risks of massive hydrate dissociation in the context of global warming, studies have recently shifted from pure hydrate crystals to hydrates in sediments. Such a research focus shift requires a series of innovative laboratory devices that are capable of investigating various properties of hydrate-bearing sediments (HBS). This study introduces a newly developed high pressure testing chamber, i.e., multi-property characterization chamber (MPCC), that allows simultaneous investigation of a series of fundamental properties of HBS, including small-strain stiffness (i.e., P- and S-waves), shear strength, large-strain deformation, stress-volume responses, and permeability. The peripheral coolant circulation system of the MPCC permits stable and accurate temperature control, while the core holder body, made of aluminum, enables X-ray computer tomography scanning to be easily employed for structural and morphological characterization of specimens. Samples of hydrate-bearing sediments are held within a rubber sleeve inside the chamber. The thick sleeve is more durable and versatile than thin membranes while also being much softer than oedometer-type chambers that are incapable of enabling flow tests. Bias introduced by the rubber sleeve during large deformation tests are also calibrated both theoretically and experimentally. This system provides insight into full characterization of hydrate-bearing sediments in the laboratory, as well as pressure core technology in the field.

36 MATERIALS SCIENCE↗

Direct sunlight facility for testing and research in HCPV

A facility for testing different components for HCPV application has been developed in the framework of 'Fotovoltaico ad Alta Efficienza' (FAE) project funded by the Sicilian Regional Authority (PO FESR Sicilia 2007/2013 4.1.1.1). The testing facility is equipped with an heliostat providing a wide solar beam inside the lab, an optical bench for mounting and aligning the HCPV components, electronic equipments to characterize the I-V curves of multijunction cells operated up to 2000 suns, a system to circulate a fluid in the heat sink at controlled temperature and flow-rate, a data logging system with sensors to measure temperatures in several locations and fluid pressures at the inlet and outlet of the heat sink, and a climatic chamber with large test volume to test assembled HCPV modules.

14 SOLAR ENERGY↗

In-situ characterization of the optical and electronic properties in GeTe and GaSb thin films

GeTe and GaSb thin films obtained by pulsed laser deposition were investigated by spectroscopic ellipsometry at controlled temperatures. The GeTe films were fully amorphous, while the GaSb films were partially crystalized in the as-deposited state. The Tauc-Lorentz model was employed to fit the experimental data. From the temperature study of the optical constants, it was observed the crystallization in the 150–160 °C range of GeTe amorphous films and between 230 and 240 °C of GaSb amorphous phase. A second transition in the resonance energy and the broadening parameter of the Lorentz oscillator was observed due to the crystallization of Sb after 250 °C. The temperatures of 85 °C and 130 °C are noticed as the start of the relaxation of the amorphous GeTe phase and as-deposited GaSb. The peaks of the imaginary part of the dielectric function red shifted after the phase change, while the variation with temperature of the crystalline phase follows the Varshni law. The electron-phonon coupling constants are 2.88 and 1.64 for c-GeTe and c-GaSb, respectively. An optical contrast up to 60% was obtained for GeTe films and a maximum value of 7.5% is revealed in the case GaSb, which is altered by the partial crystallinity of the as-deposited films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing automotive fuel cell materials by soft x-ray scanning transmission x-ray microscopy

Proton-Exchange Membrane Fuel Cell (PEM-FC) based engines are being developed rapidly for near-term implementation in hydrogen fueled, mass production, personal automobiles. Research is focused on understanding and controlling various degradation processes (carbon corrosion, Pt migration, cold start), and reducing cost by reducing or eliminating Pt catalyst. We are using soft X-ray scanning transmission X-ray microscopy (STXM) at the S 2p, C 1s, O 1s and F 1s edges to study a variety of issues related to optimization of PEM-FC materials for automotive applications. A method to efficiently and accurately measure perfluorosulfonic acid distributions was developed and is being used to better understand how different loadings and preparation methods affect the ionomer distribution in the cathode. Progress towards an environmental cell capable of controlling the temperature and humidity of a PEM-FC sample in the STXM is described. Methods for studying the 3D chemical structure of PEM-FC are outlined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray nanoprobe project at Taiwan Photon Source

The hard X-ray nanoprobe facility at Taiwan Photon Source (TPS) provides versatile X-ray analysis techniques, with tens of nanometer resolution, including XRF, XAS, XEOL, projection microscope, CDI, etc. Resulting from the large numerical aperture obtained by utilizing Montel KB mirrors, the beamline with a moderate length 75 meters can conduct similar performance with those beamlines longer than 100 meters. The two silica-made Montel mirrors are 45 degree cut and placed in a V-shape to eliminate the gap loss and the deformation caused by gravity. The slope error of the KB mirror pair is less than 0.04 µrad accomplished by elastic emission machining (EEM) method. For the beamline, a horizontal DCM and two-stage focusing in horizontal direction is applied. For the endstation, a combination of SEM for quickly positioning the sample, a fly scanning system with laser interferometers, a precise temperature control system, and a load lock transfer system will be implemented. In this presentation, the design and construction progress of the beamline and endstation is reported. The endstation is scheduled to be in commissioning phase in 2016.

43 PARTICLE ACCELERATORS↗

Spin Seebeck effect in insulating SrFeO 3–δ films

In SrFeO 3–δ , noncollinear antiferromagnetic spin textures have led to the observation of the topological Hall effect and may give rise to novel magnetic excitations. Here, we measured the spin Seebeck effect in epitaxial, oxygen reduced SrFeO 3–δ films, which are nonferromagnetic and insulating at low temperatures. Here, we detected a spin Seebeck signal below 300K and the signal is enhanced below approximate to 100K, near the ordering temperature of incommensurate antiferromagnetism found in bulk single crystals of SrFeO 3–δ . The spin Seebeck signal increases in magnitude and develops a nonlinear dependence on the magnetic field at lower temperatures. Control experiments were used to verify that the measured signal arises from a spin current and to rule out magnetic proximity effects. Our work shows a detectable spin Seebeck signal in nonferromagnetic insulator SrFeO 3–δ .

36 MATERIALS SCIENCE↗

Tailoring low energy electron absorption via surface nano-engineering of cesiated chromium films

Here, we demonstrate that improved low energy electron absorption is achieved by suppressing the crystallinity of chromium thin-films grown on W[110], which points to a promising route for achieving highly efficient thermionic energy converters. Using low energy electron microscopy (LEEM) and in situ film growth, we show that substrate temperature control permits well-controlled fabrication of either epitaxial Cr[110] films or nanocrystalline Cr layers. We show that the work function of cesium saturated nanocrystalline Cr thin-films is ~0.20 eV lower than that of epitaxial Cr[110] films. Our LEEM measurements of absorbed and reflected currents as a function of electron energy demonstrate that nanocrystallinity of cesiated chromium films results in 96% electron absorption in the range up to 1 eV above the work function, compared to just 79% absorption in cesiated crystalline Cr[110] films. These results point to metal films with suppressed crystallinity as an economical and scalable means to synthesize nanoengineered surfaces with optimized properties for next generation anode materials in high performance thermionic energy converters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of substrate temperature on sputter-deposited boron carbide films

Sputter deposition of B4C films with tailored physical properties remains a challenge. Here, we systematically study how substrate temperature influences the properties of B4C films deposited by direct current magnetron sputtering onto planar substrates held at temperatures in the range of 100-510°C. Results show that all films are amorphous stoichiometric B4C, with low O content of ~1 at. %. Films deposited onto substrates at 100°C exhibit high compressive residual stress and decreased mechanical properties. Therefore, for elevated substrate temperatures in the range of 180-510°C, film mass density, surface roughness, Young’s modulus, and hardness are weakly dependent on substrate temperature. However, in this temperature range, an increase in substrate temperature leads to larger residual compressive stress accompanied by a corresponding reduction in the concentration of nanoscale inhomogeneities. At least for the landing atom ballistics conditions studied here, a substrate temperature range of ~185-250°C is optimum for growing films with near-zero intrinsic residual stress. The overall weak substrate temperature dependence of film properties revealed in this work is favorable for the development of a robust deposition process, particularly for the case of deposition onto non-planar substrates where temperature control is often challenging.

36 MATERIALS SCIENCE↗

Demonstration of improved laser preheat with a cryogenically cooled magnetized liner inertial fusion platform

We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed: an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ~89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. Furthermore, the integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.

47 OTHER INSTRUMENTATION↗

A liquid metal dropper for experiments on the wettability of liquid metals on plasma facing components

A liquid metal dropper has been developed as a part of the Ion-Gas-Neutral Interactions with Surfaces 2 (IGNIS-2) facility at The Pennsylvania State University. The dropper has the capability of directly applying drops to candidate plasma facing materials for nuclear fusion reactors to enable measurements of their liquid metal wetting properties. The results presented here are specific to the use of lithium in the dropper. This paper discusses the design choices of the liquid metal dropper and its chamber, including the heating and temperature control and the dropper’s motorized operation. Lithium drops of masses ranging from 0.05 g up to 0.13 g, equivalent to drop diameters between 5.6 mm to 1 cm, have been consistently dispensed by the dropper. A new algorithm is developed and used to automate the analysis of the contact angle between the liquid drops and substrate material for efficient analysis of video data recorded to study the wetting properties of candidate plasma-facing components.

Instruments & Instrumentation↗

Design improvements for a recirculating reactor: Enhanced temperature measurement and sample-isolated reactivity in steady-state kinetic studies

Building upon a previous recirculating reactor design [S.A. Tenney, K. Xie, J.R. Monnier, A. Rodriguez, R.P. Galhenage, S. Audrey, D.A. Chen, Rev. Sci. Instrum. 84, 104101 (2013)], we present significant improvements that address key limitations in steady-state kinetic measurements for heterogeneous catalysis. The enhanced reactor design features direct sample heating with a focused IR lamp and temperature measurement in direct contact with the sample, enabling more accurate temperature control and improved kinetic analysis. A critical advancement is the isolation of sample reactivity from reactor wall contributions, ensuring that only the sample contributes to measured reaction rates. This was a limitation in earlier designs where the entire reactor contributed to the observed reactivity. The system incorporates a bypass flow cell for direct comparison with powder catalysts under identical conditions using a standard plug-flow reactor configuration. We demonstrate these capabilities through CO oxidation experiments on Pt(111) single crystals and graphene-passivated Pt(111), highlighting the system's ability to differentiate catalytic activity in model systems and directly compare them with high surface area powder catalysts. This reactor is particularly suited for thin films and low surface area catalysts that are not effectively evaluated in traditional flow reactors, especially for samples with low numbers of active sites or slow reaction rates.

36 MATERIALS SCIENCE↗