Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Baryon acoustic oscillations from the complete SDSS-III Lyα-quasar cross-correlation function at z = 2.4

We present a measurement of baryon acoustic oscillations (BAO) in the cross-correlation of quasars with the Lyα-forest flux-transmission at a mean redshift z = 2.40. The measurement uses the complete SDSS-III data sample: 168,889 forests and 234,367 quasars from the SDSS Data Release DR12. In addition to the statistical improvement on our previous study using DR11, we have implemented numerous improvements at the analysis level allowing a more accurate measurement of this cross-correlation. We also developed the first simulations of the cross-correlation allowing us to test different aspects of our data analysis and to search for potential systematic errors in the determination of the BAO peak position. We measure the two ratios D H (z = 2.40)=r d = 9.01 ± 0.36 and D M (z = 2.40)=r d = 35.7 ±1.7, where the errors include marginalization over the non-linear velocity of quasars and the metal - quasar cross-correlation contribution, among other effects. These results are within 1.8σ of the prediction of the flat-ΛCDM model describing the observed CMB anisotropies.We combine this study with the Lyα-forest auto-correlation function (Bautista et al. 2017), yielding D H (z = 2.40)=r d = 8.94 ± 0.22 and D M (z = 2.40)=r d = 36.6 ± 1.2, within 2.3σ of the same flat-ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

COSMOGRAIL: XVII. Time delays for the quadruply imaged quasar PG 1115+080

Here, we present time-delay estimates for the quadruply imaged quasar PG 1115+080. Our results are based on almost daily observations for seven months at the ESO MPIA 2.2m telescope at La Silla Observatory, reaching a signal-to-noise ratio of about 1000 per quasar image. In addition, we re-analyze existing light curves from the literature that we complete with an additional three seasons of monitoring with the Mercator telescope at La Palma Observatory. When exploring the possible source of bias we consider the so-called microlensing time delay, a potential source of systematic error so far never directly accounted for in previous time-delay publications. In fifteen years of data on PG 1115+080, we find no strong evidence of microlensing time delay. Therefore not accounting for this effect, our time-delay estimates on the individual data sets are in good agreement with each other and with the literature. Combining the data sets, we obtain the most precise time-delay estimates to date on PG 1115+080, with Δt(AB) = 8.3 +1.5 –1.6 days (18.7% precision), Δt(AC) = 9.9 +1.1 –1.1 days (11.1%) and Δt(BC) = 18.8 +1.6 –1.6 days (8.5%). Turning these time delays into cosmological constraints is done in a companion paper that makes use of ground-based Adaptive Optics (AO) with the Keck telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Unexpected topology of the temperature fluctuations in the cosmic microwave background

We study the topology generated by the temperature fluctuations of the cosmic microwave background (CMB) radiation, as quantified by the number of components and holes, formally given by the Betti numbers, in the growing excursion sets. We compare CMB maps observed by the Planck satellite with a thousand simulated maps generated according to the $Λ$CDM paradigm with Gaussian distributed fluctuations. The comparison is multi-scale, being performed on a sequence of degraded maps with mean pixel separation ranging from 0.05 to 7.33°. The survey of the CMB over S 2 is incomplete due to obfuscation effects by bright point sources and other extended foreground objects like our own galaxy. To deal with such situations, where analysis in the presence of “masks” is of importance, we introduce the concept of relative homology. The parametric χ 2 -test shows differences between observations and simulations, yielding p -values at percent to less than permil levels roughly between 2 and 7°, with the difference in the number of components and holes peaking at more than 3 σ sporadically at these scales. The highest observed deviation between the observations and simulations for b 0 and b 1 is approximately between 3 σ and 4 σ at scales of 3–7°. There are reports of mildly unusual behaviour of the Euler characteristic at 3.66° in the literature, computed from independent measurements of the CMB temperature fluctuations by Planck ’s predecessor, the Wilkinson Microwave Anisotropy Probe (WMAP) satellite. The mildly anomalous behaviour of the Euler characteristic is phenomenologically related to the strongly anomalous behaviour of components and holes, or the zeroth and first Betti numbers, respectively. Further, since these topological descriptors show consistent anomalous behaviour over independent measurements of Planck and WMAP, instrumental and systematic errors may be an unlikely source. These are also the scales at which the observed maps exhibit low variance compared to the simulations, and approximately the range of scales at which the power spectrum exhibits a dip with respect to the theoretical model. Non-parametric tests show even stronger differences at almost all scales. Crucially, Gaussian simulations based on power-spectrum matching the characteristics of the observed dipped power spectrum are not able to resolve the anomaly. Understanding the origin of the anomalies in the CMB, whether cosmological in nature or arising due to late-time effects, is an extremely challenging task. Regardless, beyond the trivial possibility that this may still be a manifestation of an extreme Gaussian case, these observations, along with the super-horizon scales involved, may motivate the study of primordial non-Gaussianity. Alternative scenarios worth exploring may be models with non-trivial topology, including topological defect models.

79 ASTRONOMY AND ASTROPHYSICS↗

BEYONDPLANCK IV. On end-to-end simulations in CMB analysis — Bayesian versus frequentist statistics

End-to-end simulations play a key role in the analysis of any high-sensitivity cosmic microwave background (CMB) experiment, providing high-fidelity systematic error propagation capabilities that are unmatched by any other means. In this paper, we address an important issue regarding such simulations, namely, how to define the inputs in terms of sky model and instrument parameters. These may either be taken as a constrained realization derived from the data or as a random realization independent from the data. We refer to these as posterior and prior simulations, respectively. We show that the two options lead to significantly different correlation structures, as prior simulations (contrary to posterior simulations) effectively include cosmic variance, but they exclude realization-specific correlations from non-linear degeneracies. Consequently, they quantify fundamentally different types of uncertainties. We argue that as a result, they also have different and complementary scientific uses, even if this dichotomy is not absolute. In particular, posterior simulations are in general more convenient for parameter estimation studies, while prior simulations are generally more convenient for model testing. Before BEYONDPLANCK, most pipelines used a mix of constrained and random inputs and applied the same hybrid simulations for all applications, even though the statistical justification for this is not always evident. BEYONDPLANCK represents the first end-to-end CMB simulation framework that is able to generate both types of simulations and these new capabilities have brought this topic to the forefront. The BEYONDPLANCK posterior simulations and their uses are described extensively in a suite of companion papers. In this work, we consider one important applications of the corresponding prior simulations, namely, code validation. Specifically, we generated a set of one-year LFI 30 GHz prior simulations with known inputs and we used these to validate the core low-level BEYONDPLANCK algorithms dealing with gain estimation, correlated noise estimation, and mapmaking.

79 ASTRONOMY AND ASTROPHYSICS↗

Early Results from the Q{sub weak} Experiment

A subset of results from the recently completed Jefferson Lab Q{sub weak} experiment are reported. This experiment, sensitive to physics beyond the Standard Model, exploits the small parity-violating asymmetry in elastic {vector e}p scattering to provide the first determination of the protons weak charge Q{sub w}{sup p}. The experiment employed a 180 {micro}A longitudinally polarized 1.16 GeV electron beam on a 35 cm long liquid hydrogen target. Scattered electrons corresponding to Q{sup 2} of 0.025 GeV{sup 2} were detected in eight Cerenkov detectors arrayed symmetrically around the beam axis. The goals of the experiment were to provide a measure of Q{sub w}{sup p} to 4.2 percent (combined statistical and systematic error), which implies a measure of sin2(thetaw) at the level of 0.3 percent, and to help constrain the vector weak quark charges C{sub 1u} and C{sub 1d}. The experimental method is described, with particular focus on the challenges associated with the worlds highest power LH{sub 2} target. The new constraints on C{sub 1u} and C{sub 1d} provided by the subset of the experiments data analyzed to date will also be shown, together with the extracted weak charge of the neutron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A broadband absorption spectrometer using light emitting diodes for ultrasensitive, in situ trace gas detection

A broadband absorption spectrometer has been developed for highly sensitive and target-selective in situ trace gas measurements. The instrument employs two distinct modes of operation: (i) broadband cavity enhanced absorption spectroscopy (BBCEAS) is used to quantify the concentration of gases in sample mixtures from their characteristic absorption features, and (ii) periodic measurements of the cavity mirrors' reflectivity are made using step-scan phase shift cavity ringdown spectroscopy (PSCRDS). The latter PSCRDS method provides a stand-alone alternative to the more usual method of determining mirror reflectivities by measuring BBCEAS absorption spectra for calibration samples of known composition. Moreover, the instrument's two modes of operation use light from the same light emitting diode transmitted through the cavity in the same optical alignment, hence minimizing the potential for systematic errors between mirror reflectivity determinations and concentration measurements. The ability of the instrument to quantify absorber concentrations is tested in instrument intercomparison exercises for NO{sub 2} (versus a laser broadband cavity ringdown spectrometer) and for H{sub 2}O (versus a commercial hygrometer). A method is also proposed for calculating effective absorption cross sections for fitting the differential structure in BBCEAS spectra due to strong, narrow absorption lines that are under-resolved and hence exhibit non-Beer-Lambert law behavior at the resolution of the BBCEAS measurements. This approach is tested on BBCEAS spectra of water vapor's 4v+{delta} absorption bands around 650 nm. The most immediate analytical application of the present instrument is in quantifying the concentration of reactive trace gases in the ambient atmosphere. The instrument's detection limits for NO{sub 3} as a function of integration time are considered in detail using an Allan variance analysis. Experiments under laboratory conditions produce a 1{sigma} detection limit of 0.25 pptv for a 10 s acquisition time, which improves with further signal averaging to 0.09 pptv in 400 s. Finally, an example of the instrument's performance under field work conditions is presented, in this case of measurements of the sum of NO{sub 3}+N{sub 2}O{sub 5} concentrations in the marine boundary layer acquired during the Reactive Halogens in the Marine Boundary Layer field campaign.

36 MATERIALS SCIENCE↗

A high pressure cell for simultaneous osmotic pressure and x-ray diffraction measurements

In this paper, we report on a novel osmotic cell, developed to simultaneously subject a sample to osmotic stress and measure structural changes by small angle x-ray diffraction. The osmotic cell offers many advantages over more conventional methods of osmotically stressing soft materials to measure their structural response. In particular, a full osmotic analysis can be performed with a single small sample (25 {mu}l). This reduces sample handling and the associated systematic errors, as well as enabling tight control and monitoring of the thermodynamic environment during osmosis, thereby increasing measurement precision. The cell design enables control of osmotic pressure to {+-}0.04 bar over a pressure range of 1-100 bar, and temperature control to {+-}0.05 deg. C. Under these conditions, the lattice spacing in lyotropic structures was resolved to better than {+-}0.005 A. Using the osmotic cell, we demonstrate good agreement with previous conventional measurements on the energy of dehydrating the fluid lamellar phase of dioleoylphosphatidylcholine in water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effect of Tissue Inhomogeneities on the Accuracy of Proton Path Reconstruction for Proton Computed Tomography

Maintaining a high degree of spatial resolution in proton computed tomography (pCT) is a challenge due to the statistical nature of the proton path through the object. Recent work has focused on the formulation of the most likely path (MLP) of protons through a homogeneous water object and the accuracy of this approach has been tested experimentally with a homogeneous PMMA phantom. Inhomogeneities inside the phantom, consisting of, for example, air and bone will lead to unavoidable inaccuracies of this approach. The purpose of this ongoing work is to characterize systematic errors that are introduced by regions of bone and air density and how this affects the accuracy of proton CT in surrounding voxels both in terms of spatial and density reconstruction accuracy. Phantoms containing tissue-equivalent inhomogeneities have been designed and proton transport through them has been simulated with the GEANT 4.9.0 Monte Carlo tool kit. Various iterative reconstruction techniques, including the classical fully sequential algebraic reconstruction technique (ART) and block-iterative techniques, are currently being tested, and we will select the most accurate method for this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis and calibration of absorptive images of Bose-Einstein condensate at nonzero temperatures

We describe the method allowing quantitative interpretation of absorptive images of mixtures of Bose-Einstein condensate and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction and eliminates arbitrariness of most of the previous approaches. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different measurements and compares well with theoretical calculations and with measurements performed by another group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deconvolution-based correction of alkali beam emission spectroscopy density profile measurements

A deconvolution-based correction method of the beam emission spectroscopy (BES) density profile measurement is demonstrated by its application to simulated measurements of the COMPASS and TEXTOR tokamaks. If the line of sight is far from tangential to the flux surfaces, and the beam width is comparable to the scale length on which the light profile varies, the observation may cause an undesired smoothing of the light profile, resulting in a non-negligible underestimation of the calculated density profile. This effect can be reduced significantly by the emission reconstruction method, which gives an estimate of the emissivity along the beam axis from the measured light profile, taking the finite beam width and the properties of the measurement into account in terms of the transfer function of the observation. Characteristics and magnitude of the mentioned systematic error and its reduction by the introduced method are studied by means of the comprehensive alkali BES simulation code RENATE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Q{sub weak}{sup p} Experiment A Test for Physics Beyond the Standard Model via a Precision Measurement of the Proton Weak Charge

The Qweak collaboration is currently preparing a measurement of the proton's weak charge Q{sub w}{sup p} = (1-4 sin{sup 2} {theta}{sub w}) at the Thomas Jefferson National Accelerator Facility (TJNAF). The experiment has been designed to produce a 4.1% measurement of the weak charge, via a 2.5% measurement of the parity violating asymmetry in the number of elastically scattered 1 GeV electrons from protons, at forward angles. At the proposed precision, the experiment would produce a 0.3% measurement of the weak mixing angle at a momentum transfer of {approx_equal}0.16 GeV, making it the most precise stand alone measurement of the weak mixing angle at low momentum transfer. In combination with other parity measurements, Qweak will also provide a high precision determination of the weak charges of the up and down quarks. Our proposed measurement of Q{sub w}{sup 2} will be performed with significantly smaller statistical and systematic errors than existing low Q{sup 2} data. Any significant deviation from the Standard Model prediction at low momentum transfer (Q{sup 2}) would be a signal of new physics, whereas agreement would place new and significant constraints on possible Standard Model extensions. The experiment is currently being prepared for installation, beginning in late 2009, and data taking beginning in mid 2010.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards High Precision Deuteron Polarimetry

A finite electric dipole moment (EDM) in any fundamental system would constitute a signal for new physics. The deuteron presents itself as an optimal candidate both experimentally and theoretically. A new storage ring technique is being developed for which a small change in the vertical polarization would be a signal of a non-zero EDM. A novel polarimeter concept is under investigation. Besides being highly efficient, this polarimeter should continuously monitor the beam polarization, guaranteeing optimal sensitivity. Detailed studies on systematic error control, in addition to the measurement of cross sections and analyzing powers, were carried out at KVI-Groningen in The Netherlands. Measurements were conducted at COSY-Juelich in Germany yielding high efficiencies. The (statistics limited) ability to track changes in polarization at the level of a few hundred parts-per-million has been demonstrated. Further studies and developments to meet the final goal of sub-part-per-million sensitivity are in progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a pepper-pot device to determine the emittance of an ion beam generated by electron cyclotron resonance ion sources

This paper describes the recent development and commissioning of a pepper-pot emittance meter at the Lawrence Berkeley National Laboratory (LBNL). It is based on a potassium bromide (KBr) scintillator screen in combination with a charged coupled device camera. Pepper-pot scanners record the full four-dimensional transverse phase space emittances which are particularly interesting for electron cyclotron resonance ion sources. The strengths and limitations of evaluating emittances using optical pepper-pot scanners are described and systematic errors induced by the optical data acquisition system will be presented. Light yield tests of KBr exposed to different ion species and first emittance measurement data using ion beams extracted from the 6.4 GHz LBNL electron cyclotron resonance ion source are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of quasi-elastic muon (anti)neutrino scattering in he NOMAD experiment

We have studied the muon neutrino and antineutrino quasi-elastic (QEL) scattering reactions (v{sub {mu}}n{yields}{mu}{sup -}p and v-bar{sub {mu}}p{yields}{mu}{sup +}n using a set of experimental data collected by the NOMAD collaboration. We have performed measurements of the cross-section of these processes on a nuclear target (mainly Carbon) normalizing it to the total v{sub {mu}} (v-bar{sub {mu}}) charged current cross-section. The results for the flux averaged QEL cross-sections in the (anti)neutrino energy interval 3-100 GeV are <{sigma}{sub qel}>v{sub {mu}} = (0.92{+-}0.02(stat){+-}0.06(syst))x10{sup -38} cm{sup 2} and <{sigma}{sub qel}>v-bar{sub {mu}} = (0.81{+-}0.05(stat){+-}0.09(syst))x10{sup -38} cm{sup 2} for neutrino and antineutrino, respectively. The axial mass parameter MA was extracted from the measured quasi-elastic neutrino cross-section. The corresponding result is M{sub A} = 1.05{+-}0.02(stat){+-}0.06(syst) GeV. It is consistent with the axial mass values recalculated from the antineutrino cross-section and extracted from the pure Q{sup 2} shape analysis of the high purity sample of v{sub {mu}} quasi-elastic 2-track events, but has smaller systematic error and should be quoted as the main result of this work. Our measured MA is found to be in good agreement with the world average value obtained in previous deuterium filled bubble chamber experiments. The NOMAD measurement of M{sub A} is lower than those recently published by K2K and MiniBooNE collaborations. However, within the large errors quoted by these experiments on M{sub A}, these results are compatible with the more precise NOMAD value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A precise new KLOE measurement of |F{sub {pi}}|{sup 2} with ISR events and determination of {pi}{pi} contribution to a{sub {mu}} for 0.592<M{sub {pi}}{sub {pi}}<0.975 GeV

The KLOE experiment at the DA{phi}NE {phi}-factory has performed a new precise measurement of the pion form factor using Initial State Radiation events, with photons emitted at small polar angle. Results based on an integrated luminosity of 240 pb{sup -1} and extraction of the {pi}{pi} contribution to a{sub {mu}} in the mass range 0.35<M{sub {pi}}{sub {pi}}{sup 2}<0.95 GeV{sup 2} are presented. The new value of a{sub {mu}}{sup {pi}}{sup {pi}} has smaller (30%) statistical and systematic error and is consistent with the KLOE published value (confirming the current disagreement between the standard model prediction for a{sub {mu}} and the measured value)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FREE SURFACE VELOCIMETRY CORRECTIONS FOR LOW PRESSURE SHOCKS

We consider how to interpret measured free surface velocities to estimate what a relatively weak shock (with an elastic-plastic two-wave structure, approx5-30 GPa) would have looked like in an infinite sample. Hysteresis and nonlinear wave interactions introduce effects (inexact velocity doubling and the delay, partial reflection, and reverberation of waves) whose magnitudes can be estimated with simple models. We argue, and demonstrate in a simulated test case, that these estimates can eliminate most of the systematic error introduced by the free surface during loading.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of Proton Structure and Parton Density Functions from HERA

A preliminary result is reported of the charged current and neutral current inclusive cross sections from e{sup +}p and e{sup -}p scattering obtained from a combination of published measurements from H1 and ZEUS. Taking into account the systematic error correlations in a coherent approach, a reduction of experimental uncertainties for combined results is achieved compared to the separate results of the H1 and ZEUS experiments. The combined results are used as input for a next-to-leading order (NLO) QCD parton distribution determination.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗