Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Strips”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Beam test measurements with planar and 3D silicon strip detectors irradiated to sLHC fluences

The planned luminosity upgrade of the CERN LHC to the super LHC (sLHC) requires investigation of new radiation hard tracking detectors. Compared to the LHC, tracking detectors must withstand a 5-10 times higher radiation fluence. Promising radiation hard options are planar silicon detectors with n-side readout and silicon detectors in 3D technology, where columnar electrodes are etched into the silicon substrate. This article presents beam test measurements per formed with planar and 3D n-in-p silicon strip detectors. The detectors were irradiated to different fluences, where the maximum fluence was 3 x 10{sup 15} 1 MeV neutron equivalent particles per square centimeter (n{sub eq}/cm{sup 2}) for the planar detectors and 2 x 10{sup 15} n{sub eq}/cm{sup 2} for the 3D detectors. In addition to signal measurements, charge sharing and resolution of both detector technologies are compared. An increased signal from the irradiated 3D detectors at high bias voltages compared to the signal from the unirradiated detector indicates that charge multiplication effects occur in the 3D detectors. At a bias voltage of 260 V, the 3D detector irradiated to 2 x 10{sup 15} n{sub eq}/cm{sup 2} yields a signal almost twice as high as the signal of the unirradiated detector. Only 30% of the signal of an unirradiated detector could be measured with the planar detector irradiated to 3 x 10{sup 15} n{sub eq}/cm{sup 2} at a bias voltage of 600 V, which was the highest bias voltage applied to this sensor.

43 PARTICLE ACCELERATORS↗

Characterization of a double-sided silicon strip detector autoradiography system

Purpose: The most commonly used technology currently used for autoradiography is storage phosphor screens, which has many benefits such as a large field of view but lacks particle-counting detection of the time and energy of each detected radionuclide decay. A number of alternative designs, using either solid state or scintillator detectors, have been developed to address these issues. The aim of this study is to characterize the imaging performance of one such instrument, a double-sided silicon strip detector (DSSD) system for digital autoradiography. A novel aspect of this work is that the instrument, in contrast to previous prototype systems using the same detector type, provides the ability for user accessible imaging with higher throughput. Studies were performed to compare its spatial resolution to that of storage phosphor screens and test the implementation of multiradionuclide ex vivo imaging in a mouse preclinical animal study. Methods: Detector background counts were determined by measuring a nonradioactive sample slide for 52 h. Energy spectra and detection efficiency were measured for seven commonly used radionuclides under representative conditions for tissue imaging. System dead time was measured by imaging {sup 18}F samples of at least 5 kBq and studying the changes in count rate over time. A line source of {sup 58}Co was manufactured by irradiating a 10 μm nickel wire with fast neutrons in a research reactor. Samples of this wire were imaged in both the DSSD and storage phosphor screen systems and the full width at half maximum (FWHM) measured for the line profiles. Multiradionuclide imaging was employed in a two animal study to examine the intratumoral distribution of a {sup 125}I-labeled monoclonal antibody and a {sup 131}I-labeled engineered fragment (diabody) injected in the same mouse, both targeting carcinoembryonic antigen. Results: Detector background was 1.81 × 10{sup −6} counts per second per 50 × 50 μm pixel. Energy spectra and detection efficiency were successfully measured for seven radionuclides. The system dead time was measured to be 59 μs, and FWHM for a {sup 58}Co line source was 154 ± 14 μm for the DSSD system and 343 ± 15 μm for the storage phosphor system. Separation of the contributions from {sup 125}I and {sup 131}I was performed on autoradiography images of tumor sections. Conclusions: This study has shown that a DSSD system can be beneficially applied for digital autoradiography with simultaneous multiradionuclide imaging capability. The system has a low background signal, ability to image both low and high activity samples, and a good energy resolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A hot and fast ultra-stripped supernova that likely formed a compact neutron star binary

Compact neutron star binary systems are produced from binary massive stars through stellar evolution involving up to two supernova explosions. The final stages in the formation of these systems have not been directly observed. Here, we report the discovery of iPTF 14gqr (SN 2014ft), a type Ic supernova with a fast-evolving light curve indicating an extremely low ejecta mass (≈0.2 solar masses) and low kinetic energy (≈2 × 10 50 ergs). Early photometry and spectroscopy reveal evidence of shock cooling of an extended helium-rich envelope, likely ejected in an intense pre-explosion mass-loss episode of the progenitor. Taken together, we interpret iPTF 14gqr as evidence for ultra-stripped supernovae that form neutron stars in compact binary systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of cluster counting technique for particle identification in a drift chamber with the cathode strip readout

The possibility of using the clusters counting technique for particle identification in a drift chamber with the cathode strip readout is experimentally investigated. Results of counting of primary ionization clusters on a relativistic particle track, as well as results of computer simulation of pion, kaon, and proton identification in the momentum range of 1–8 GeV/c, are presented.

Berdnikov, Vladimir V.↗

Physical processes involved in strip electrode welding using the method of slatted splicing

Physical processes that take place in a strip electrode during welding using the slatted splicing technique are considered. Flowing of the welding current in the electrode is shown to be the key process which determines electrode heating and melting. Technological receipts are proposed that allow obtaining high-quality welds by the method of slatted splicing.

36 MATERIALS SCIENCE↗

Position-Sensitive Spectrometric Module for Detecting Ionizing Radiation by Semiconductor Strip Detectors

A position-sensitive module for detecting ionizing radiation based on semiconductor strip detectors and a multichannel spectrometric route has been developed and implemented. The dynamic range of the detected charge generated by an ionizing particle in the detector is 5–250 fC. The position-sensitive module is a structurally complete device with the functions of amplifying the spectrometric signal, digitizing, buffering, preprocessing, and transmitting data to a computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam loss modeling and mitigation due to intra-beam stripping

Intra-Beam Stripping (IBS) is a critical beam loss mechanism in high-intensity H- linacs and presents a significant limitation to increasing beam power. This work presents a computational framework to evaluate and mitigate IBS-induced beam loss along the Spallation Neutron Source (SNS) LINAC. Our calculation is based on an analytic theory and involves evaluation of a 9D integral using the Monte-Carlo technique. We first benchmarked our calculations against simplified, analytically solvable cases. We then applied our algorithm to Gaussian bunches with a known probability density function (PDF). We next expanded our algorithm to arbitrary bunch distributions using the Neural Spline Flow (NSF) models trained on PyORBIT tracking data. In the future, we plan to validate our algorithm experimentally and apply it to design IBS mitigation strategies.

Nln, Shivam [ORNL]↗

Results Of Routine Strip Effluent Hold Tank, Decontaminated Salt Solution Hold Tank, And Caustic Wash Tank Samples From Modular Caustic-Side Solvent Extraction Unit During Macrobatch 4 Operations

Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), and Caustic Wash Tank (CWT) samples from several of the "microbatches" of Integrated Salt Disposition Project (ISDP) Salt Batch ("Macrobatch") 4 have been analyzed for 238 Pu, 90 Sr, 137 Cs, and by inductively-coupled plasma emission spectroscopy (ICPES). Furthermore, samples from the CWT have been analyzed by a variety of methods to investigate a decline in the decontamination factor (DF) of the cesium observed at MCU.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MicroCT: X-Ray Radiograph Quality Assurance Through the Analysis of Copper Strip Data Using the Matlab CuStrip Analysis GUI

This Standard Operating Procedure (SOP) supplements the LEDP data acquisition SOPand reference material and specimen analysis SOP, and provides the specific procedural steps for analyzing copper strip (CuStrip) data using the Matlab CuStrip Analysis Graphical User Interface and preparing the tables and graphs to be used in the reporting of analytical results as required by the LEDP Quality Assurance Plan for MicroCT Scanning]. This procedure applies only to the analysis of two-slit data.

42 ENGINEERING↗

Results of Routine Strip Effluent Hold Tank and Decontaminated Salt Solution Hold Tank Samples from Modular Caustic-Side Solvent Extraction Unit during Macrobatch 5 Operations

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the "microbatches" of Integrated Salt Disposition Project (ISDP) Salt Batch ("Macrobatch") 5 have been analyzed for 238 Pu, 90 Sr, 137 Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The results indicate good decontamination performance within process design expectations. While the data set is sparse, the results of this set and the previous set of results for Macrobatch 4 samples indicate generally consistent operations. The DSSHT samples show continued presence of titanium, likely from leaching of the monosodium titanate in the Actinide Removal process (ARP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnetic Processing of Steel Strip and Next Generation Alloys

High magnetic field processing was applied in two separate process configurations. In the first configuration, a laboratory-scale continuous razor blade processing line incorporating ORNL’s ambient temperature high magnetic field technology for increased energy efficiency and material performance enhancement was successfully demonstrated during the project. This facility simulated a critical portion of a high temperature heat-treatment razor blade material processing line and demonstrated that a costly and energy inefficient cryogenic cooling processing to control retained austenite (RA) could be eliminated with an ambient temperature magnetic process. Magnetic processing resulted in improved process energy efficiency, reduced microstructural variability in the final product, and higher hardness for better performance than currently employed cryogenic commercial processing. Therefore, from both a technical and cost benefit perspective, high magnetic field processing incorporated into a razor strip production line was shown to be a technically-feasible, commercially-viable approach to making a superior blade razor product.

Ludtka, Gerard Michael↗

Results Of Routine Strip Effluent Hold Tank, Decontaminated Salt Solution Hold Tank, Caustic Wash Tank And Caustic Storage Tank Samples From Modular Caustic-Side Solvent Extraction Unit During Macrobatch 6 Operations

Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Caustic Storage Tank (CST) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 6 have been analyzed for 238 Pu, 90 Sr, 137 Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The results from the current microbatch samples are similar to those from comparable samples in Macrobatch 5. From a bulk chemical point of view, the ICPES results do not vary considerably between this and the previous macrobatch. The titanium results in the DSSHT samples continue to indicate the presence of Ti, when the feed material does not have detectable levels. This most likely indicates that leaching of Ti from MST in ARP continues to occur. Both the CST and CWT samples indicate that the target Free OH value of 0.03 has been surpassed. While at this time there is no indication that this has caused an operational problem, the CST should be adjusted into specification. The 137 Cs results from the SRNL as well as F/H lab data indicate a potential decline in cesium decontamination factor. Further samples will be carefully monitored to investigate this.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of CD Scribed Strip from the 1st Continental Disc

In July 2013, the NIF has entered an agreement with the Continental Disc (CD) to improve the fatigue life of the rupture panel with a serious of experiments. This memo summarizes the result of our measurements on the 1st strip we received on Oct. 9, 2013 from the CD.

36 MATERIALS SCIENCE↗

Results Of Routine Strip Effluent Hold Tank, Decontaminated Salt Solution Hold Tank, Caustic Wash Tank And Caustic Storage Tank Samples From Modular Caustic-Side Solvent Extraction Unit During Macrobatch 6 Operations

Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Caustic Storage Tank (CST) samples from the Interim Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 6 have been analyzed for 238 Pu, 90 Sr, 137 Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The Pu, Sr, and Cs results from the current Macrobatch 6 samples are similar to those from comparable samples in previous Macrobatch 5. In addition the SEHT and DSSHT heel samples (i.e. ‘preliminary’) have been analyzed and reported to meet NGS Demonstration Plan requirements. From a bulk chemical point of view, the ICPES results do not vary considerably between this and the previous samples. The titanium results in the DSSHT samples continue to indicate the presence of Ti, when the feed material does not have detectable levels. This most likely indicates that leaching of Ti from MST has increased in ARP at the higher free hydroxide concentrations in the current feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bench-Scale Development of a Hot Carbonate Absorption Process with Crystallization-Enabled High Pressure Stripping for Post-Combustion CO 2 Capture

This report summarizes the methodology and preliminary results of a techno-economic analysis on a hot carbonate absorption process (Hot-CAP) with crystallization-enabled high pressure stripping for post-combustion CO 2 capture (PCC). This analysis was based on the Hot-CAP that is fully integrated with a sub-critical steam cycle, pulverized coal-fired power plant adopted in Case 10 of the DOE/NETL’s Cost and Performance Baseline for Fossil Energy Plants. The techno-economic analysis addressed several important aspects of the Hot-CAP for PCC application, including process design and simulation, equipment sizing, technical risk and mitigation strategy, performance evaluation, and cost analysis. Results show that the net power produced in the subcritical power plant equipped with Hot-CAP is 611 MWe, greater than that with Econoamine (550 MWe). The total capital cost for the Hot-CAP, including CO 2 compression, is $\$ $399 million, less than that for the Econoamine PCC ($\$ $493 million). O&M costs for the power plant with Hot-CAP is $\$ $175 million annually, less than that with Econoamine ($\$ $178 million). The 20-year levelized cost of electricity (LCOE) for the power plant with Hot-CAP, including CO 2 transportation and storage, is 119.4 mills/kWh, a 59% increase over that for the plant without CO 2 capture. The LCOE increase caused by CO 2 capture for the Hot-CAP is 31% lower than that for its Econoamine counterpart.

20 FOSSIL-FUELED POWER PLANTS↗

Plan for the Purchase of MCT and EDS Reference Materials, Source Filters, Cu Strips, and Carousel Sub-Assemblies

The goal of this effort is to improve the quality and consistency of MCT and EDS data across the program. New references, aluminum (Al) and Cu filters, and Cu strips will be of known high purity and quality, traceable to documented chemical analyses. A single Program organization will be responsible to purchase, fabricate, assemble, inspect, control, and supply these items to the Program to ensure adequate and uniform quality and quality control.

42 ENGINEERING↗

Consideration of Factors Affecting Strip Effluent pH and Sodium Content

A number of factors were investigated to determine possible reasons for why the Strip Effluent (SE) can sometimes have higher than expected pH values and/or sodium content, both of which have prescribed limits. All of the factors likely have some impact on the pH values and Na content.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consideration of Factors Affecting Strip Effluent pH and Sodium Content

A number of factors were investigated to determine possible reasons for why the Strip Effluent (SE) can sometimes have higher than expected pH values and/or sodium content, both of which have prescribed limits. All of the factors likely have some impact on the pH values and Na content.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗