Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Characterization of a commercial hybrid iterative and model-based reconstruction algorithm in radiation oncology

Purpose: Iterative reconstruction (IR) reduces noise, thereby allowing dose reduction in computed tomography (CT) while maintaining comparable image quality to filtered back-projection (FBP). This study sought to characterize image quality metrics, delineation, dosimetric assessment, and other aspects necessary to integrate IR into treatment planning. Methods: CT images (Brilliance Big Bore v3.6, Philips Healthcare) were acquired of several phantoms using 120 kVp and 25–800 mAs. IR was applied at levels corresponding to noise reduction of 0.89–0.55 with respect to FBP. Noise power spectrum (NPS) analysis was used to characterize noise magnitude and texture. CT to electron density (CT-ED) curves were generated over all IR levels. Uniformity as well as spatial and low contrast resolution were quantified using a CATPHAN phantom. Task specific modulation transfer functions (MTF{sub task}) were developed to characterize spatial frequency across objects of varied contrast. A prospective dose reduction study was conducted for 14 patients undergoing interfraction CT scans for high-dose rate brachytherapy. Three physicians performed image quality assessment using a six-point grading scale between the normal-dose FBP (reference), low-dose FBP, and low-dose IR scans for the following metrics: image noise, detectability of the vaginal cuff/bladder interface, spatial resolution, texture, segmentation confidence, and overall image quality. Contouring differences between FBP and IR were quantified for the bladder and rectum via overlap indices (OI) and Dice similarity coefficients (DSC). Line profile and region of interest analyses quantified noise and boundary changes. For two subjects, the impact of IR on external beam dose calculation was assessed via gamma analysis and changes in digitally reconstructed radiographs (DRRs) were quantified. Results: NPS showed large reduction in noise magnitude (50%), and a slight spatial frequency shift (∼0.1 mm{sup −1}) with application of IR at L6. No appreciable changes were observed for CT-ED curves between FBP and IR levels [maximum difference ∼13 HU for bone (∼1% difference)]. For uniformity, differences were ∼1 HU between FBP and IR. Spatial resolution was well conserved; the largest MTF{sub task} decrease between FBP and IR levels was 0.08 A.U. No notable changes in low-contrast detectability were observed and CNR increased substantially with IR. For the patient study, qualitative image grading showed low-dose IR was equivalent to or slightly worse than normal dose FBP, and is superior to low-dose FBP (p < 0.001 for noise), although these did not translate to differences in CT number, contouring ability, or dose calculation. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using the most aggressive IR level [−1.2 ± 4.9 HU (range: −17.6–12.5 HU)]. No clinically significant contour differences were found between IR and FBP, with OIs and DSCs ranging from 0.85 to 0.95. Negligible changes in dose calculation were observed. DRRs preserved anatomical detail with <2% difference in intensity from FBP combined with aggressive IRL6. Conclusions: These results support integrating IR into treatment planning. While slight degradation in edges and shift in texture were observed in phantom, patient results show qualitative image grading, contouring ability, and dosimetric parameters were not adversely affected.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-06: Prospective Patient Evaluation of Iterative Reconstruction in Radiation Oncology

Purpose: This work incorporates iterative reconstruction (IR) into a dose reduction study to characterize image quality metrics, delineation, and dosimetric assessment, with the goal of reducing imaging dose in Radiation Oncology. Methods: Three-dimensional noise power spectrum (NPS) analysis characterized noise magnitude/texture (120 kVp, 50–200 mAs, IR levels 1–6 yielding noise reduction of 0.89–0.55 compared to filtered backprojection (FBP)). Task-specific Modulation Transfer Functions (MTFtask) were characterized across varied subject contrasts. A prospective dose reduction study (500 to 150 mAs) was conducted for 12 patients (43 inter-fraction CTs) for high-dose rate brachytherapy. Three physicians performed qualitative image assessment between full-dose FBP (FD-FBP, 500 mAs), low-dose FBP (LD-FBP, 150–250 mAs), and low-dose IRL5-6 (LD-IR) scans for image noise, cuff/bladder interface detectability, spatial resolution, texture, and segmentation confidence. Comparisons between LD-FBP and LD-IR were conducted for the following metrics: delineation (bladder and rectum evaluated via overlap indices (OI) and Dice similarity coefficients (DSC)), noise, boundary changes, dose calculation, and digitally reconstructed radiographs (DRRs). Results: NPS showed ∼50% reduction in noise magnitude and ∼0.1 1/mm spatial frequency shift with IRL6. The largest MTFtask decrease between FBP and IR was 0.08 A.U. Qualitative patient image evaluation revealed LD-IR was equivalent or slightly worse than FD-FBP, and superior to LD-FBP for all metrics except low contrast interface and texture. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using IRL6 (−1.2 ± 4.9 HU (range: −17.6 – 12.5 HU)). No significant contour differences (OIs and DSCs = 0.85 – 0.95) and dose calculation discrepancy (<0.02%) were observed. DRRs preserved anatomical detail and demonstrated <2% difference in intensity between LD-FBP and LD-IRL6. Conclusion: While phantom analysis showed slight noise texture differences with IR, patient results revealed that image quality, contouring ability, and dosimetric parameters were not adversely affected, thus support integrating IR into treatment planning. Research supported in part by a grant from Philips HealthCare.

60 APPLIED LIFE SCIENCES↗

MO-FG-204-04: How Iterative Reconstruction Algorithms Affect the NPS of CT Images

Purpose: To evaluate how the third generation model based iterative reconstruction (MBIR) compares with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASiR), and the second generation MBIR based on noise power spectrum (NPS) analysis over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP515 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 19mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 0.984 pitch and reconstructed thickness 2.5mm (VEO3.0: Abd/Pelvis with Texture and NR05). At each CTDIvol level, 10 repeated scans were acquired for achieving sufficient data sampling. The images were reconstructed using Standard kernel with FBP; 20%, 40% and 70% ASiR; and two versions of MBIR (VEO2.0 and 3.0). For evaluating the effect of the ROI spatial location to the Result of NPS, 4 ROI groups were categorized based on their distances from the center of the phantom. Results: VEO3.0 performed inferiorly comparing to VEO2.0 over all dose levels. On the other hand, at low dose levels (less than 3 mGy), it clearly outperformed ASiR and FBP, in NPS values. Therefore, the lower the dose level, the relative performance of MBIR improves. However, the shapes of the NPS show substantial differences in horizontal and vertical sampling dimensions. These differences may determine the characteristics of the noise/texture features in images, and hence, play an important role in image interpretation. Conclusion: The third generation MBIR did not improve over the second generation MBIR in term of NPS analysis. The overall performance of both versions of MBIR improved as compared to other reconstruction algorithms when dose was reduced. The shapes of the NPS curves provided additional value for future characterization of the image noise/texture features.

60 APPLIED LIFE SCIENCES↗

Hydrothermal Synthesis and Characterization of a New Strandberg-type Diphosphopentamolybdate (C{sub 6}N{sub 3}H{sub 18}){sub 2}[P{sub 2}Mo{sub 5}O{sub 23}] · 6H{sub 2}O

An inorganic-organic hybrid material formulated as (C{sub 6}N{sub 3}H{sub 18}){sub 2}[P{sub 2}Mo{sub 5}O{sub 23}] · 6H{sub 2}O, has been hydrothermally synthesized and characterized by single crystal X-ray diffraction technique, IR spectrum, thermogravimetric analysis and UV-visible spectroscopy. The structure consists of diphosphopentamolybdate Strandberg type polyoxoanions [P{sub 2}Mo{sub 5}O{sub 23}]{sup 6–}, protonated 1-(2-aminoethyl)piperazine cations and six crystallization water molecules. These anions are connected with the organic amine through hydrogen bonding interactions between the hydrogen atoms of the organic molecules and the oxygen atoms of the polyoxoanion and water molecules which generate a three-dimensional network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging and microanalysis of thin ionomer layers by scanning transmission electron microscopy

Improved conditions for imaging and spectroscopic mapping of thin perfluorosulfonic acid (PFSA) ionomer layers in fuel cell electrodes by scanning transmission electron microscopy (STEM) have been investigated. These conditions are first identified on model systems of Nafion ionomer-coated nanostructured thin films and nanoporous Si. The optimized conditions are then applied in a quantitative study of the ionomer through-layer loading for two typical electrode catalyst coatings using electron energy loss and energy dispersive X-ray spectroscopy in the transmission electron microscope. The e-beam induced damage to the perfluorosulfonic acid (PFSA) ionomer is quantified by following the fluorine mass loss with electron exposure and is then mitigated by a few orders of magnitude using cryogenic specimen cooling and a higher incident electron voltage. Multivariate statistical analysis is also applied to the analysis of spectrum images for data denoising and unbiased separation of independent components related to the catalyst, ionomer, and support.

Cullen, David A↗

Cathodoluminescence Spectrum Imaging Software [SWR-11-08]

The software developed for spectrum imaging is applied to the analysis of the spectrum series generated by our cathodoluminescence instrumentation. This software provides advanced processing capabilities s such: reconstruction of photon intensity (resolved in energy) and photon energy maps, extraction of the spectrum from selected areas, quantitative imaging mode, pixel-to-pixel correlation spectrum line scans, ASCII, output, filling routines, drift correction, etc.

Romero, ManuelJ.↗

Concerning the Spatial Heterodyne Spectrometer

A modified Spatial Heterodyne Spectrometer (SHS) is used for measuring atomic emission spectra with high resolution. This device is basically a Fourier Transform Spectrometer, but the Fourier transform is taken in the directions perpendicular to the optical propagation and heterodyned around one preset wavelength. In recent descriptions of this device, one specific phenomenon - the tilt of the energy front of wave packets when diffracted from a grating - was neglected. This led to an overestimate of the resolving power of this spectrograph, especially in situations when the coherence length of the radiation under test is in the order of the effective aperture of the device. In conclusion, the limits of usability are shown here together with some measurements of known spectral lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gap-filled meteorological data (2011-2020) and modeled potential evapotranspiration data from the KCOMTCRE2 WeatherUnderground weather station, from the East River Watershed, Colorado

This dataset is a gap-filled meteorological dataset (years 2011-2020) that includes modeled potential evapotranspiration from a station near the pumphouse on the East River (KCOMTCRE2 WeatherUnderground ) near the top of the ridge at the Pumphouse PLM wells. These datasets are useful as model inputs. The KOMTCRE2 station is located on Mt. Crested Butte in Colorado. More information can be found at: https://www.wunderground.com/dashboard/pws/KCOMTCRE2/table/2020-12-7/2020-12-7/daily. The purpose of this dataset is to use as input to hydrological and flow-reactive transport models as meteorological forcing. One attached file includes metadata files with definitions for all variables and units. Subsequent files include the same time series dataset, but aggregated and gap-filled at different time-stamp intervals. These include 5 minute time-series, 15 minute time-series, 30 minute time-series, 1 hour time-series, daily time-series, and hourly and daily modeled evapotranspiration.

54 ENVIRONMENTAL SCIENCES↗

New Routes for the Production of Fission Products and Their Separation from the Source Material for the Development of Realistic Nuclear Forensic Debris

In order to fully characterize the NIF neutron spectrum, SAND-II-SNL software was requested/received from the Radiation Safety Information Computational Center. The software is designed to determine the neutron energy spectrum through analysis of experimental activation data. However, given that the source code was developed in Sparcstation 10, it is not compatible with current version of FORTRAN. Accounts have been established through the Lawrence Livermore National Laboratory’s High Performance Computing in order to access different compiles for FORTRAN (e.g. pgf77, pgf90). Additionally, several of the subroutines included in the SAND-II-SNL package have required debugging efforts to allow for proper compiling of the code.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Technical Report for DOE Award SC0006616

This report summarizes research carried out by the project "Collaborative Research, Type 1: Decadal Prediction and Stochastic Simulation of Hydroclimate Over Monsoonal Asia. This collaborative project brought together climate dynamicists (UCLA, IRI), dendroclimatologists (LDEO Tree Ring Laboratory), computer scientists (UCI), and hydrologists (Columbia Water Center, CWC), together with applied scientists in climate risk management (IRI) to create new scientific approaches to quantify and exploit the role of climate variability and change in the growing water crisis across southern and eastern Asia. This project developed new tree-ring based streamflow reconstructions for rivers in monsoonal Asia; improved understanding of hydrologic spatio-temporal modes of variability over monsoonal Asia on interannual-to-centennial time scales; assessed decadal predictability of hydrologic spatio-temporal modes; developed stochastic simulation tools for creating downscaled future climate scenarios based on historical/proxy data and GCM climate change; and developed stochastic reservoir simulation and optimization for scheduling hydropower, irrigation and navigation releases.

54 ENVIRONMENTAL SCIENCES↗

Scoping Analysis of Sodium Cooled Fast Spectrum Test Reactor Cores

A team from the national laboratories conducted a study that assessed advanced reactor technology options and the irradiation needs of a broad group of stakeholders. This identified a gap in the fast neutron irradiation capability - the need for a test reactor that can deliver high neutron fluxes of fast neutrons. The study compared fast and thermal neutron irradiation technology options based on technology maturity and the ability to meet strategic objectives, along with pathways to deployment and tradeoffs in mission. It also provided a recommendation on specific technology options to address the current gap in fast neutron irradiation capabilities. In this context, a detailed scope of work was prepared that pertains to a trade study focusing on the core of a fast neutron spectrum test reactor. This report presents the main results obtained by a team of Argonne National Laboratory (ANL) and Idaho National Laboratory (INL) scientists. It aims at developing an overall understanding of how the various areas important to the design and successful operation of such a facility interact with one another. Developing a sense of the relevant sensitivities at a systems level creates an understanding of where and how margins may be available to improve performances (e.g., flux level, capacity factor, and thermal hydraulic limits). Emphasis is given to the reactor (core design options and safety) and its fuel cycle (fuel supply and fabrication, as well as spent fuel management).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Depletion Analysis of a Generic Fast Spectrum Molten Salt Reactor Supporting Material Control and Accounting (Rev.1)

Advanced reactors are of interest for a variety of use scenarios, and there are numerous advanced reactor designs being considered, which includes molten salt reactors (MSRs). Depending on the design, advanced reactors may have more extensive material control and accounting (MC&A) processes than current Light Water Reactor (LWR) designs. This project evaluated the use of Monte Carlo simulations for generating information that could guide the development of MC&A approaches for MSRs. In particular, the current capabilities of MCNP version 6.3 internally coupled with CINDER’90 were assessed for a fast spectrum liquid fueled MSR with online fission product removal and refueling. The fission product removal and refueling was performed in batches, and a Python wrapper was developed to control the simulations and update the fuel composition.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Background Measurements and Simulations of the ComPair Balloon Flight

ComPair, a prototype of the All-sky Medium Energy Gamma-ray Observatory (AMEGO), completed a short-duration high-altitude balloon campaign on 27 August 2023 from Fort Sumner, New Mexico, USA. The goal of the balloon flight was to demonstrate ComPair as both a Compton and Pair telescope in flight, reject the charged particle background, and measure the background γ-ray spectrum. This analysis compares measurements from the balloon flight with Monte Carlo simulations to benchmark the instrument. The comparison finds good agreement between the measurements and simulations and supports the conclusion that ComPair accomplished its goals for the balloon campaign. Additionally, two charged particle background rejection schemes are discussed: a soft ACD veto that records a higher charged particle event rate but with less risk of event loss, and a hard ACD veto that limits the charged particle event rate on board. There was little difference in the measured spectra from the soft and hard ACD veto schemes, indicating that the hard ACD veto could be used for future flights. The successes of ComPair’s engineering flight will inform the development of the next generation of ComPair with upgraded detector technology and larger active area.

79 ASTRONOMY AND ASTROPHYSICS↗

RECOVERY OF LARGE ANGULAR SCALE CMB POLARIZATION FOR INSTRUMENTS EMPLOYING VARIABLE-DELAY POLARIZATION MODULATORS

Variable-delay Polarization Modulators (VPMs) are currently being implemented in experiments designed to measure the polarization of the cosmic microwave background on large angular scales because of their capability for providing rapid, front-end polarization modulation and control over systematic errors. Despite the advantages provided by the VPM, it is important to identify and mitigate any time-varying effects that leak into the synchronously modulated component of the signal. In this paper, the effect of emission from a 300 K VPM on the system performance is considered and addressed. Though instrument design can greatly reduce the influence of modulated VPM emission, some residual modulated signal is expected. VPM emission is treated in the presence of rotational misalignments and temperature variation. Simulations of time-ordered data are used to evaluate the effect of these residual errors on the power spectrum. The analysis and modeling in this paper guides experimentalists on the critical aspects of observations using VPMs as front-end modulators. By implementing the characterizations and controls as described, front-end VPM modulation can be very powerful for mitigating 1/f noise in large angular scale polarimetric surveys. None of the systematic errors studied fundamentally limit the detection and characterization of B-modes on large scales for a tensor-to-scalar ratio of r = 0.01. Indeed, r < 0.01 is achievable with commensurately improved characterizations and controls.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray spectral and temporal analysis of narrow line Seyfert 1 galaxy Was 61

We present an analysis of spectrum and variability of the bright reddened narrow line Seyfert 1 galaxy Was 61 using 90 ks archival XMM-Newton data. The X-ray spectrum in 0.2–10 keV can be characterized by an absorbed power-law plus soft excess and an Fe Kα emission line. The power-law spectral index remains constant during the flux variation. The absorbing material is mildly ionized, with a column density of 3.2 × 10{sup 21} cm{sup −2}, and does not appear to vary during the period of the X-ray observation. If the same material causes the optical reddening (E(B–V) ≃ 0.6 mag), it must be located outside the narrow line region with a dust-to-gas ratio similar to the average Galactic value. We detect significant variations of the Fe Kα line during the observational period. A broad Fe Kα line at ≃6.7 keV with a width of ∼0.6 keV is detected in the low flux segment of the first 40 ks exposure, and is absent in the spectra of other segments; a narrow Fe Kα emission line ∼6.4 keV with a width of ∼0.1 keV is observed in the subsequent 20 ks segment, which has a count rate 35% higher and is in the next day. We believe this is due to the change in geometry and kinematics of the X-ray emitting corona. The temperature and flux of soft X-ray excess appear to correlate with the flux of the hard power-law component. Comptonization of disc photons by a warm and optically thick inner disk is preferred to interpret the soft excess, rather than the ionized reflection.

79 ASTRONOMY AND ASTROPHYSICS↗

RESOLVING THE ROTATION MEASURE OF THE M87 JET ON KILOPARSEC SCALES

We investigate the distribution of Faraday rotation measure (RM) in the M87 jet at arcsecond scales by using archival polarimetric Very Large Array data at 8, 15, 22 and 43 GHz. We resolve the structure of the RM in several knots along the jet for the first time. We derive the power spectrum in the arcsecond-scale jet and find indications that the RM cannot be associated with a turbulent magnetic field with a 3D Kolmogorov spectrum. Our analysis indicates that the RM probed on jet scales has a significant contribution of a Faraday screen associated with the vicinity of the jet, in contrast with that on kiloparsec scales, typically assumed to be disconnected from the jet. Comparison with previous RM analyses suggests that the magnetic fields giving rise to the RMs observed in jet scales have different properties and are well less turbulent than those observed in the lobes.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopic Determination of Stellar Parameters and Oxygen Abundances for Hyades/Field G–K Dwarfs

It has been suggested that Fe abundances of K dwarfs derived from Fe i and Fe ii lines show considerable discrepancies, and oxygen abundances determined from high-excitation O i 7771–5 triplet lines are appreciably overestimated (the problem becoming more serious toward lower T {sub eff}), which, however, has not yet been widely confirmed. With the aim of clarifying this issue, we spectroscopically determined the atmospheric parameters of 148 G–K dwarfs (Hyades cluster stars and field stars) by assuming the classical Fe i/Fe ii ionization equilibrium as usual, and determined their oxygen abundances by applying the non-local thermal equilibrium spectrum fitting analysis to O i 7771–5 lines. It turned out that the resulting parameters did not show any significant inconsistency with those determined by other methods (for example, the mean differences in T {sub eff} and logg from the well-determined solutions of Hyades dwarfs are mostly ≲100 K and ≲0.1 dex). Likewise, the oxygen abundances of Hyades stars are around [O/H] ∼ +0.2 dex (consistent with the metallicity of this cluster) without exhibiting any systematic T {sub eff}-dependence. Accordingly, we conclude that parameters can be spectroscopically evaluated to a sufficient precision in the conventional manner (based on the Saha–Boltzmann equation for Fe i/Fe ii) and oxygen abundances can be reliably determined from the O i 7771–5 triplet for K dwarfs as far as stars of T {sub eff} ≳ 4500 K are concerned. We suspect that previously reported strongly T {sub eff}-dependent discrepancies may have stemmed mainly from overestimation of weak-line strengths and/or improper T {sub eff} scale.

79 ASTRONOMY AND ASTROPHYSICS↗