Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Measurement of apparent ion temperature using the magnetic recoil spectrometer at the OMEGA laser facility

The Magnetic Recoil neutron Spectrometer (MRS) at the OMEGA laser facility has been routinely used to measure deuterium-tritium (DT) yield and areal density in cryogenically layered implosions since 2008. Recently, operation of the OMEGA MRS in higher-resolution mode with a new smaller, thinner (4 cm[sup]2, 57-um thick) CD2 conversion foil has also enabled inference of the apparent DT ion temperature (Tion) from MRS data. MRS-inferred Tion compares well with T[sub]ion as measured using neutron time-of-flight spectrometers, which is important as it demonstrates good understanding of the very different systematics associated with the two independent measurements. The MRS resolution in this configuration, deltaEMRS=0.91 MeV FWHM, is still higher than required for a high-precision Tion measurement. We show how fielding a smaller foil closer to target chamber center and redesigning the MRS detector array could bring the resolution to deltaEMRS=0.45 MeV, reducing the systematic Tion uncertainty by more than a factor of 4.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multidimensional spectrometer

A multidimensional spectrometer for the infrared, visible, and ultraviolet regions of the electromagnetic spectrum, and a method for making multidimensional spectroscopic measurements in the infrared, visible, and ultraviolet regions of the electromagnetic spectrum. The multidimensional spectrometer facilitates measurements of inter- and intra-molecular interactions.

Zanni, Martin Thomas↗

Heterodyne photomixer spectrometer with receiver photomixer driven at different frequency than source photomixer

A heterodyne photomixer spectrometer comprises a receiver photomixer that is driven at a different frequency than the source photomixer, thereby maintaining the coherent nature of the detection, eliminating etalon effects, and providing not only the amplitude but also the phase of the received signal. The heterodyne technique can be applied where the source and receiver elements are components of a waveguide thereby forming an on-chip heterodyne spectrometer.

47 OTHER INSTRUMENTATION↗

Wide size range fast integrated mobility spectrometer

A mobility spectrometer to measure a nanometer particle size distribution is disclosed. The mobility spectrometer includes a conduit and a detector. The conduit is configured to receive and provide fluid communication of a fluid stream having a charged nanometer particle mixture. The conduit includes a separator section configured to generate an electrical field of two dimensions transverse to a dimension associated with the flow of the charged nanometer particle mixture through the separator section to spatially separate charged nanometer particles of the charged nanometer particle mixture in said two dimensions. The detector is disposed downstream of the conduit to detect concentration and position of the spatially-separated nanometer particles.

47 OTHER INSTRUMENTATION↗

MICE Spectrometer Solenoid Magnetic Field Measurements

The Muon Ionization Cooling Experiment (MICE) is designed to demonstrate ionization cooling in a muon beam. Its goal is to measure a 10% change in transverse emittance of a muon beam going through a prototype Neutrino Factory cooling channel section with an absolute measurement accuracy of 0.1%. To measure emittances, MICE uses two solenoidal spectrometers, with Solenoid magnets designed to have 4 T fields, uniform at 3 per mil level in the tracking volumes. Magnetic field measurements of the Spectrometer Solenoid magnet SS2, and analysis of coil parameters for input into magnet models will be discussed.

43 PARTICLE ACCELERATORS↗

Precision mechanical structure of an ultra-high-resolution spectrometer for inelastic X-ray scattering instrument

A method and an ultrahigh-resolution spectrometer including a precision mechanical structure for positioning inelastic X-ray scattering optics are provided. The spectrometer includes an X-ray monochromator and an X-ray analyzer, each including X-ray optics of a collimating (C) crystal, a pair of dispersing (D) element crystals, anomalous transmission filter (F) and a wavelength (W) selector crystal. A respective precision mechanical structure is provided with the X-ray monochromator and the X-ray analyzer. The precision mechanical structure includes a base plate, such as an aluminum base plate; positioning stages for D-crystal alignment; positioning stages with an incline sensor for C/F/W-crystal alignment, and the positioning stages including flexure-based high-stiffness structure.

36 MATERIALS SCIENCE↗

The SeaQuest Spectrometer at Fermilab

The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques for controlling distance between a sample and sample probe while such probe liberates analyte from a sample region for analysis with a mass spectrometer

A system includes a mass spectrometer and associated sample interfacing equipment. The sample interfacing equipment includes a platform structured to support a sample thereon, a fluid source, a high voltage source, a dispensing probe electrically coupled to the high voltage source and defining a fluid dispensing passage therethrough, a collection probe defining a collection passage therethrough, a sensing arrangement coupled to the dispensing probe, and control logic responsive to the sensing arrangement to control distance between the dispensing probe and the sample. The dispensing probe facilitates formation of one or more ionized sample analytes when dispensing the fluid through the dispensing passage proximate to the sample on the platform. The collecting probe receives at least some of the one or more ionized sample analytes to pass through the collection passage into the mass spectrometer for analysis.

47 OTHER INSTRUMENTATION↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Design and performance of a multi-terahertz Fourier transform spectrometer for axion dark matter experiments

Dedicated spectrometers for terahertz radiation with [0.3, 30] THz frequencies using traditional optomechanical interferometry are substantially less common than their infrared and microwave counterparts. This paper presents the design and initial performance measurements of a tabletop Fourier transform spectrometer (FTS) for multi-terahertz radiation using infrared optics in a Michelson arrangement. This is coupled to a broadband pyroelectric photodetector designed for [0.1, 30] THz frequencies. We measure spectra of narrowband and broadband input radiation to characterize the performance of this instrument above 10 THz, where signal-to-noise is high. This paves the groundwork for planned upgrades to extend below 10 THz. We also briefly discuss potential astroparticle physics applications of such FTS instruments to broadband axion dark matter searches, whose signature comprises low-rate monochromatic photons with unknown frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray spectrometer and methods for use

A spectrometer includes a crystal analyzer having a radius of curvature that defines a Rowland circle, a sample stage configured to support a sample such that the sample is offset from the Rowland circle, an x-ray source configured to emit unfocused x-rays toward the sample stage, and a position-sensitive detector that is tangent to the Rowland circle. A method performed via a spectrometer includes emitting, via an x-ray source, unfocused x-rays toward a sample that is mounted on a sample stage such that the sample is offset from the Rowland Circle, thereby causing the sample to emit x-rays that impinge on the crystal analyzer or transmit a portion of the unfocused x-rays to impinge on the crystal analyzer; scattering, via the crystal analyzer, the x-rays that impinge on the crystal analyzer; and detecting the scattered x-rays via a position-sensitive detector that is tangent to the Rowland circle.

Seidler, Gerald Todd↗

Compact folded metasurface spectrometer

Compact optical devices such as spectrometers are realized with metasurfaces within a dielectric medium confined by reflective surfaces. The metasurfaces control the phase profiles of the reflected electromagnetic waves within the device. In a compact spectrometer, the metasurfaces within the device separate the electromagnetic waves in different wavelengths. The metasurfaces are designed according to their phase profile by varying the size of the array of scatterers.

Faraji-Dana, MohammadSadegh↗

Polarized SIDIS Experiments with SoLID Spectrometer at 12 GeV Jefferson Lab

The Jefferson Lab 12 GeV upgrade will provide unique opportunity to perform polarized semi-inclusive deep inelastic scattering (SIDIS) experiments with very high precision. The measured single and double spin asymmetries (SSA/DSA) in these reactions will provide an access to various transverse momentum dependent parton distribution functions (TMDs). In particular, the experimentally measured SSA on proton and neutron targets can help us in extracting the transversity and Sivers distribution functions of u and d-quarks. Similarly, the measured DSA are sensitive to the quark spin-orbit correlations, and provide access to the worm-gear function (g1T). In this talk, we will present our plans for performing these precision measurements in Hall-A using a large acceptance SoLID spectrometer and polarized proton and 3He targets with 11 GeV beam. The high luminosities from these targets and the large acceptance of the SoLID spectrometer will allow for a precise 4-dimensional (x,Q2,z,PT) mapping of SSA and DSA. The data will provide comprehensive information on the correlation between quark angular momentum and the nucleon's spin.

Allada, Kalyan↗

Quartz Detector for the SuperHMS Spectrometer at Hall-C Jefferson Lab

We have developed and constructed a quartz hodoscope to be part of the trigger system for the Super High Momentum Spectrometer (SHMS). The SHMS spectrometer will play a central role in carrying out the 12-GeVphysics program at Hall-C Jefferson Lab. The hodoscope consists of twenty one fused silica bars. Each bar is 125-cm long, 5.5-cm wide, and 2.5-cm thick. It is viewed by a UV-sensitive PMT on each end. The quartz hodoscope task is to provide a clean detection of charged particles, a high level of background suppression, and an accurate tracking efficiency determination. We present results of tests leading to the construction of the hodoscope, as well performance test results of the completed detectors such as detection efficiency and position resolution.

Ahmidouch, Abdellah↗

Hodoscope for spectrometer optics calibration in APEX dark matter search

The A' Experiment (APEX) to be conducted in Hall A of Jefferson Lab (JLab) is a high sensitivity search for a proposed dark matter A' boson. To improve sensitivity APEX will make use of a new High Resolution Spectrometer (HRS) calibration method using a scintillating fiber (SciFi) hodoscope. A prototype SciFi hodoscope is developed to evaluate and improve the characteristics of the hodoscope design. The use of an active detector to calibrate the HRS is expected to allow for direct spectrometer calibration at any momentum setting without the use of special beam energies and improve scattering angle resolution by approximately 30\%.

Goeckner-Wald, Neil↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Advanced Radionuclide Gamma spectrOmeter-2 (ARGO-2) for Low-level Radionuclide Measurements

A low-level multidimensional gamma spectrometer was recently installed at Pacific Northwest National Laboratory, USA. The spectrometer utilizes a dual-detector design and advanced detection techniques, demonstrating superior detection efficiency/sensitivity. This work details integral components of the system, including the dual-detector design, its shielding, and cosmic veto panels for background reduction. Results from system’s operation in singles and coincidence mode are highlighted.

ARGO, Coincidence measurements, Multidimensional g↗

X-ray spectrometer and methods for use

A spectrometer includes a crystal analyzer having a radius of curvature that defines a Rowland circle, a sample stage configured to support a sample such that the sample is offset from the Rowland circle, x-ray source configured to emit unfocused x-rays toward the sample stage, and a position-sensitive detector that is tangent to the Rowland circle. A method performed via a spectrometer includes emitting, via an x-ray source, unfocused x-rays toward a sample that is mounted on a sample stage such that the sample is offset from the Rowland Circle, thereby causing the sample to emit x-rays that impinge on the crystal analyzer or transmit a portion of the unfocused x-rays to impinge on the crystal analyzer; scattering, via the crystal analyzer, the x-rays that impinge on the crystal analyzer; and detecting the scattered x-rays via a position-sensitive detector that is tangent to the Rowland circle.

Seidler, Gerald Todd↗