Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Multiple experimental studies of pore structure and mineral grain sizes of the Woodford shale in southern Oklahoma, USA

Pore structure study is an important part of unconventional shale reservoir characterization, since the pore system provides the primary petroleum storage space and fluid flow pathways. Previous studies have suggested that the pore structure is related to the total organic carbon (TOC) content, mineral compositions, and the maturity of the organic matter (OM). However, few studies have focused on the mineral grains, the primary grains being deposited but before cementation, which are the building blocks of shale. Eight Woodford Shale outcrop samples from southern Oklahoma were chosen to study the effects of mineral grain size on the pore structure characterization, using multiple and complementary experimental approaches, including laser diffraction, mineralogy, TOC, pyrolysis, liquid immersion porosimetry, mercury intrusion porosimetry, gas physisorption, (ultra) small angle X-ray scattering, scanning electron microscopy, and spontaneous imbibition. The results from different experiments of eight samples show that the Woodford Shale has the mean mineral grain diameters at 3–6 μm, a wide range of porosity at 3–40% and pore diameters at 50–1,000 nm, and various pore connectivity. Grain size variation was probably caused by the sea-level fluctuation during its deposition, which affect the porosity, pore size distribution, and pore connectivity. With decreasing mineral grain sizes, the porosity tends to increase while the pore connectivity worsens. The results also indicate that OM and carbonates in this low-maturity Woodford Shale could block the pores and decrease the porosity. Coupling with the grain size analyses, the control of depositional environment on grain sizes and subsequent effects on pore structure is identified. The pore structure characteristics over a wide pore-diameter range provided by multiple experiments could improve the understanding of storage space and fluid flow in the Woodford Shale to further increase its petroleum production.

54 ENVIRONMENTAL SCIENCES↗

A Component-Sizing Methodology for a Hybrid Electric Vehicle Using an Optimization Algorithm

Many leading companies in the automotive industry have been putting tremendous effort into developing new powertrains and technologies to make their products more energy efficient. Evaluating the fuel economy benefit of a new technology in specific powertrain systems is straightforward; and, in an early concept phase, obtaining a projection of energy efficiency benefits from new technologies is extremely useful. However, when carmakers consider new technology or powertrain configurations, they must deal with a trade-off problem involving factors such as energy efficiency and performance, because of the complexities of sizing a vehicle’s powertrain components, which directly affect its energy efficiency and dynamic performance. As powertrains of modern vehicles become more complicated, even more effort is required to design the size of each component. This study presents a component-sizing process based on the forward-looking vehicle simulator “Autonomie” and the optimization algorithm “POUNDERS”; the supervisory control strategy based on Pontryagin’s Minimum Principle (PMP) assures sufficient computational system efficiency. We tested the process by applying it to a single power-split hybrid electric vehicle to determine optimal values of gear ratios and each component size, where we defined the optimization problem as minimizing energy consumption when the vehicle’s dynamic performance is given as a performance constraint. The suggested sizing process will be helpful in determining optimal component sizes for vehicle powertrain to maximize fuel efficiency while dynamic performance is satisfied. Indeed, this process does not require the engineer’s intuition or rules based on heuristics required in the rule-based process.

33 ADVANCED PROPULSION SYSTEMS↗

Statistical Tool Size Study for Computer-Controlled Optical Surfacing

Over the past few decades, computer-controlled optical surfacing (CCOS) systems have become more deterministic. A target surface profile can be predictably achieved with a combination of tools of different sizes. However, deciding the optimal set of tool sizes that will achieve the target residual error in the shortest run time is difficult, and no general guidance has been proposed in the literature. In this paper, we present a computer-assisted study on choosing the proper tool size for a given surface error map. First, we propose that the characteristic frequency ratio (CFR) can be used as a general measure of the correction capability of a tool over a surface map. Second, the performance of different CFRs is quantitatively studied with a computer simulation by applying them to guide the tool size selection for polishing a large number of randomly generated surface maps with similar initial spatial frequencies and root mean square errors. Finally, we find that CFR = 0.75 achieves the most stable trade-off between the total run time and the number of iterations and thus can be used as a general criterion in tool size selection for CCOS processes. To the best of our knowledge, the CFR is the first criterion that ties tool size selection to overall efficiency.

36 MATERIALS SCIENCE↗

GRAIN SIZE CONSTRAINTS ON HL TAU WITH POLARIZATION SIGNATURE

The millimeter-wave polarization of the protoplanetary disk around HL Tau has been interpreted as the emission from elongated dust grains aligned with the magnetic field in the disk. However, the self-scattering of thermal dust emission may also explain the observed millimeter-wave polarization. In this paper, we report a modeling of the millimeter-wave polarization of the HL Tau disk with the self-polarization. Dust grains are assumed to be spherical and to have a power-law size distribution. We change the maximum grain size with a fixed dust composition in a fixed disk model to find the grain size to reproduce the observed signature. We find that the direction of the polarization vectors and the polarization degree can be explained with the self-scattering. Moreover, the polarization degree can be explained only if the maximum grain size is ∼150 μm. The obtained grain size from the polarization is different from that which has been previously expected from the spectral index of the dust opacity coefficient (a millimeter or larger) if the emission is optically thin. We discuss that porous dust aggregates may solve the inconsistency of the maximum grain size between the two constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing the Recovery of Intrinsic Galaxy Sizes and Masses of z ∼ 2 Massive Galaxies Using Cosmological Simulations

Accurate measurements of galaxy masses and sizes are key to tracing galaxy evolution over time. Cosmological zoom-in simulations provide an ideal test bed for assessing the recovery of galaxy properties from observations. Here, we utilize galaxies with M{sub ∗}∼10{sup 10}--10{sup 11.5} M{sub ⊙} at z ∼ 1.7–2 from the MassiveFIRE cosmological simulation suite, part of the Feedback in Realistic Environments (FIRE) project. Using mock multi-band images, we compare intrinsic galaxy masses and sizes to observational estimates. We find that observations accurately recover stellar masses, with a slight average underestimate of ∼0.06 dex and a∼0.15 dex scatter. Recovered half-light radii agree well with intrinsic half-mass radii when averaged over all viewing angles, with a systematic offset of ∼0.1 dex (with the half-light radii being larger) and a scatter of ∼0.2 dex. When using color gradients to account for mass-to-light variations, recovered half-mass radii also exceed the intrinsic half-mass radii by ∼0.1 dex. However, if not properly accounted for, aperture effects can bias size estimates by ∼0.1 dex. No differences are found between the mass and size offsets for star-forming and quiescent galaxies. Variations in viewing angle are responsible for ∼25% of the scatter in the recovered masses and sizes. Our results thus suggest that the intrinsic scatter in the mass–size relation may have previously been overestimated by ∼25%. Moreover, orientation-driven scatter causes the number density of very massive galaxies to be overestimated by ∼0.5 dex at M{sub ∗}∼10{sup 11.5} M{sub ⊙}.

79 ASTRONOMY AND ASTROPHYSICS↗

SGP Merged Aerosol Size Distribution (CPC+SMPS+APS)

Five years (2009-2013) of data from three instrument at the SGP site were merged in order to create a new aerosol size distribution dataset. Data from the scanning mobility particle sizer (SMPS), part of the TDMA system, were combined with size distribution data from the aerodynamic particle sizer (APS). The merged size distribution from those two instruments spanned the diameter (mobility) size range between ~12 nm and ~14 um with 215 bins (Collins 2010). Total aerosol number concentrations from a TSI 3010 condensation particle counter (CPC) were then used to adjust and constrain the SMPS+APS size distributions and to extend the size distribution down to ~7 nm. Collins, D: Tandem Differential Mobility Analyzer/Aerodynamic Particular Sizer (APS) Handbook. DOE ARM Climate Research Facility. DOE/SC-ARM-TR-090, 2010.

54 ENVIRONMENTAL SCIENCES↗

black carbon mass loading, size distribution for CACTI - ground site

The Single-Particle Soot Photometer (SP2, Droplet Mea- surement Technologies) is an instrument that measures, in situ, the time-dependent scattering and incandescence signals produced by individual BC-containing particles as they travel through a continuous-wave laser beam. Any particle traversing the laser beam will scatter light, and the BC component of a BC-containing particle will absorb some of the laser energy until its temperature is raised to the point at which it incandesces (hereafter we adopt the standard terminology of the SP2 community and denote any substance determined by the SP2 to be BC as refractory black carbon (rBC)). The scattering signal provides information on particle size, and the incandescence signal is used for counting rBC-containing particles and yields the mass of the rBC component within each particle (obtained via calibration). Hence, the SP2 can determine size-resolved number and mass concentrations of rBC-containing particles and thus provides information on the rBC particle population-based mixing states within ambient aerosols rBC concentration is reported at STP conditions Time resolution: 1-min Uncertainty: ~ 30% SP2 Unit: 25 Location: Ascension Island, British Territory Location: 7° 56' S, 14° 25' W" SP2_dateTime: UTC rBC concentration is in units of ng/m^3 - dry air. Mass Equivalent Diameters [MED] used for size distribution (SP2_min; SP2_geo; and SP2_max) are in units of micrometers dN/dlogDp counts for a given size bin (SP2_geo) listed as 'SP2_cnts_0…SP2_cnts_199'. Column naming convention: 'SP2_cnts_X' are the number of particles in bin number _X. , where _X is the row number within the 'SP2_geo' size bin column that contains the mass equivalent diameter (e.g., SP2_cnts_0 = 0.01 microns; SP2_cnts_10 = 0.060 microns, etc…). The dN/dlogDp data is time-resolved where a given row is associated with the timestamp for that row. Note that the rBC column length is one field shorter than the SP2_datetime column. Last time field is not relevant to the rBC time series (see comment below on length of SP2_datetime column) Lengths for SP2_max; SP2_min; SP2_geo are one field longer then the number of SP2_cnts_XX columns . This is to provide bounds for image plots (if desired). Length for SP2_datetime is one field longer than that length of the SP2_cnts_XX columns This is to provide bounds for image plots (if desired) SP2 Calibration: Fullerene soot with corrrection applied for particle density as a function of particle size. No correction for OC content in Fullerene (recent study on SP2 sensitivity to differing black carbon types reports that non-refractory material content for fullerene soot is about 20%). Comments and/or requests are to be directed to Art Sedlacek (sedlacek@bnl.gov)

54 ENVIRONMENTAL SCIENCES↗

HISCALE: Best Estimate Aerosol Size Distribution by airborne measurements

The data were collected during the Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems (HI-SCALE, http://www.arm.gov/campaigns/aaf2016hiscale) field campaign as part of ARM Aerial Facility (AAF) deployment. The ARM Aerial Facility Gulfstream-1 was deployed at Bartlesville, OK, for two intensive observation periods from April 23 through May 22 and from August 27 through September 25, 2016. The G-1 aircraft performed 38 (17+21) research flights over the ARM Southern Great Plains (SGP) Atmospheric Observatory to measure atmospheric turbulence, cloud water content and drop size distributions, aerosol precursor gases, aerosol chemical composition and size distributions. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 4 sensors: two aerosol spectrometers (FIMS and PCASP) and two cloud probes (CAS and FCDP). Aerosol chemical composition, measured by the Aerodyne High Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS), was used to estimate aerosol refractive index (RI) required for correction of the equivalent optical size into geometric size

54 ENVIRONMENTAL SCIENCES↗

ACE-ENA: Best Estimate Aerosol Size Distribution by airborne measurements

These data were collected during the Aerosol and Cloud Experiments in the Eastern North Atlantic field campaign as part of ARM Aerial Facility deployment (ACE-ENA, https://www.arm.gov/research/campaigns/aaf2017ace-ena). The ARM Aerial Facility Gulfstream-1 was deployed at Lajes Air Base (IATA: TER, ICAO: LPLA), on Terceira Island in the Azores, Portugal, for the two Intensive Observation Periods from June 20 through July 22, 2017 (IOP#1) and from January 11 through February 22, 2018 (IOP#2). The G-1 aircraft performed 20+19 research flights over the ARM Eastern North Atlantic (ENA) site and Atlantic Ocean to measure atmospheric turbulence, cloud water content and drop size distributions, aerosol precursor gases, aerosol chemical composition and size distributions. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 4 sensors: two aerosol spectrometers (FIMS and PCASP) and two cloud probes (CAS and FCDP). Aerosol chemical composition, measured by the Aerodyne High Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS), was used to estimate aerosol refractive index (RI) required for correction of the equivalent optical size into geometric size.

54 ENVIRONMENTAL SCIENCES↗

Measurements of Aerosol Charge and Size Distribution for Graphite, Gold, Palladium, and Silver Nanoparticles

The role of charge on aerosol evolution and hence the nuclear source term has been an issue of interest, and there is a need for both experimental techniques and modeling for quantifying this role. Our focus here is on further exploration of a tandem differential mobility analyzer (TDMA) technique to simultaneously measure both the size and charge (positive, negative and neutral) dependent aerosol distributions. We have generated graphite, gold, silver, and palladium nanoparticles (aerosol) using a spark generator. We measure the electrical mobility-size distributions for these aerosols using a TDMA, and from these data we deduce the full charge-size distributions. We observe asymmetry in the particle size distributions for negative and positive charges. This asymmetry could have a bearing on the dynamics of charged aerosols, indicating that the assumption of symmetry for size distributions of negatively and positively charged particles in source term simulations may not be always appropriate. Also, the experimental technique should find applications in measurements of aerosol rate processes that are affected by both particle charge and size (e.g. coagulation, deposition, resuspension), and hence in modeling and simulation of the nuclear source term.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EXTINCTION DROPLET SIZING MEASUREMENTS IN DIESEL RELEVANT SPRAYS

A new diagnostic for the quantification of Sauter Mean Diameter (SMD) in high-pressure fuel sprays has been recently developed using combined optical and x-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination (DBI) imaging, conducted at Georgia Tech, and liquid absorption measurements from x-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the Scattering Absorption Measurement Ratio (SAMR), quantifies two-dimensional distributions of path-integrated SMD, enabling construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The spatially-resolved SMD measurements that result from the SAMR diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine CFD codes. The methodology for quantification of SMD distributions using the SAMR technique has been previously introduced. This thesis aims to extend the initial development of the SAMR technique by presenting in detail: the experimental methodologies used in the SAMR technique, including the development of an ideal DBI setup for this technique; the data processing methodologies developed by the author; two-dimensional Sauter Mean Diameter measurements within diesel sprays for various experimental conditions; a summary of the various sources of measurement uncertainty; an assessment for how the sources of uncertainty affect the quantified SMD; and paths to improve the technique moving forward. The SMD results show that for low ambient density conditions droplets decrease in size as radial and axial position increases. For high ambient density conditions, however, the droplets show a stable size near the spray centerline and steadily increase in size as distance from the centerline increases. Additionally, this work provides 2-D droplet sizing maps which are particularly useful for model validation.

33 ADVANCED PROPULSION SYSTEMS↗

EXTINCTION DROPLET SIZING MEASUREMENTS IN DIESEL RELEVANT SPRAYS

A new diagnostic for the quantification of Sauter Mean Diameter (SMD) in high-pressure fuel sprays has been recently developed using combined optical and x-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination (DBI) imaging, conducted at Georgia Tech, and liquid absorption measurements from x-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the Scattering Absorption Measurement Ratio (SAMR), quantifies two-dimensional distributions of path-integrated SMD, enabling construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The spatially-resolved SMD measurements that result from the SAMR diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine CFD codes. The methodology for quantification of SMD distributions using the SAMR technique has been previously introduced. This thesis aims to extend the initial developmen of SAMR technique by presenting in detail: the experimental methodologies used in the SAMR technique, including the development of an ideal DBI setup for this technique; the data processing methodologies developed by the author; two-dimensional Sauter Mean Diameter measurements within diesel sprays for various experimental conditions; a summary of the various sources of measurement uncertainty; an assessment for how the sources of uncertainty affect the quantified SMD; and paths to improve the technique moving forward. The SMD results show that for low ambient density conditions droplets decrease in size as radial and axial position increases. For high ambient density conditions, however, the droplets show a stable size near the spray centerline and steadily increase in size as distance from the centerline increases. Additionally, this work provides 2-D droplet sizing maps which are particularly useful for model validation.

33 ADVANCED PROPULSION SYSTEMS↗

Effects of Sludge Particle Size and Density on Hanford Waste Processing

The U.S. Department of Energy Office of River Protection's Waste Treatment and Immobilization Plant (WTP) will process and treat radioactive waste that is stored in tanks at the Hanford Site in southeastern Washington State. Piping and pumps have been selected to transport the high-level waste (HLW) slurries in the WTP. Pipeline critical-velocity calculations for these systems require the input of a bounding particle size and density. Various approaches based on statistical analyses have been used in the past to provide an estimate of this bounding size and density. In this paper, representative particle size and density distributions (PSDDs) of Hanford waste insoluble solids have been developed based on the new approach that relates measured particle size distributions (PSDs) to solid-phase compounds. This work was achieved through extensive review of available Hanford waste PSDs and solid-phase compound data. Composite PSDs representing the waste in up to 19 Hanford waste tanks were developed, and the insoluble solid phase compounds for the 177 Hanford waste tanks, their relative fractions, crystal densities, and particle size and shape were developed. With such a large combination of particle sizes and particle densities, a Monte Carlo simulation approach was used to model the PSDDs. Further detail was added by including an agglomeration of these compounds where the agglomerate density was modeled with a fractal dimension relation. The Monte Carlo simulations were constrained to hold the following relationships: 1) the composite PSDs are reproduced, 2) the solid-phase compound mass fractions are reproduced, 3) the expected in situ bulk-solids density is qualitatively reproduced, and 4) a representative fraction of the sludge volume comprising agglomerates is qualitatively reproduced to typical Hanford waste values. Four PSDDs were developed and evaluated. These four PSDD scenarios correspond to permutations where the master PSD was sonicated or not-sonicated before being analyzed and whether agglomerates existed or not in the PSD samples. When critical pipeline velocity calculations are applied to these results, several percent of Hanford tank waste sludge are expected to exceed pipeline velocities of 4 ft/sec. Operation and waste processing at pipeline velocities in the >4 to 6 ft/sec range appear to be compatible with the Hanford sludge in 3-inch pipes. (authors)

42 ENGINEERING↗

Manufacture of large grain size of Gd{sub 2}O{sub 3}-UO{sub 2} pellets adding Al(OH){sub 3}

In order to improve the utilization of nuclear fuel, reduce the cost of fuel cycle and improve the economics and flexibility of nuclear power plant in the latest light-water reactors, designers usually adopt the operation strategy of high burnup, long cycle, low leakage, such as using burnable poison fuel in nuclear reactors. So the Gd{sub 2}O{sub 3}-UO{sub 2} pellets is widely used as burnable poison fuel. Pellets is harmful for the running of nuclear reactor if the grain size is too large or too small. Generally, the grain size of Gd{sub 2}O{sub 3}-UO{sub 2} pellets can be called big grain pellets if the grain size is larger than 10 μm. In order to get big grain Gd{sub 2}O{sub 3}-UO{sub 2} pellets, researcher usually adopt grain growth agent to increase the grain size of pellets, this article research the rule of density, pore and grain size of Gd{sub 2}O{sub 3}-UO{sub 2} pellets by adding Al(OH){sub 3}. Al(OH){sub 3} breaks down Al{sub 2}O{sub 3} and H{sub 2}O which can increase the spread of the cation in the lattice, which cause the growth of grain in Gd{sub 2}O{sub 3}-UO{sub 2} pellets. Besides, it also determines the process route of average grain size of more than 10 μm in pellets.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Acoustic Monitor for Particle Size and Bed Friction in a Carbonate Fluidized Bed at High Temperature - 18014

Previous work has shown that acoustic spectra of fluidized bed pressure fluctuations show many useful bed properties [1-3]. This current work further explores the use of acoustic monitors for an 18' diameter, 66-74'' height fluidized bed at >640 deg. C. This process denitrates and agglomerates an injected sodium/aluminum nitrate aqueous simulant and produces at steady-state a denitrated product of 200-300 micron sodium carbonate/aluminate particles. The fluidized bed shows characteristic acoustic resonances around 1-2 Hz in the FFT (Fast Fourier Transform) of pressure fluctuations for each of three taps at fluidized bed heights of 12'', 39'', and 58''. The acoustic resonance spectra depend on a bed friction that once calibrated, monitors the HMPD (harmonic mass mean particle diameter or Sauter mean diameter) along with other important bed properties. This fluidized bed operates at high temperature with an evolving HMPD that can be steady state with an appropriate superficial spatial velocity (SSV). The acoustic FFT integrated power spectrum, IPS, of pressure fluctuations represents the bed-friction damped RMS (root mean square) pressure fluctuations at each tap. The transition from a static to fluidized bed at each bed height occurs when the damped bed RMS pressure fluctuations are greater than the static head (the FFT zero Hz designated zero Hz proportional to FFT zero Hz) at that bed height. A bed will de-fluidize and become static at a bed height when bed friction completely dampens the RMS pressure fluctuations, which occurs for decreasing particle size among other factors. The ratio IPS/zero Hz then provides a continuous monitor of bed friction damping as well as particle size as the HMPD. Since HMPD and bed friction damping are both very important parameters for fluidized particle beds, the acoustic HMPD and bed friction damping both provide very useful monitors for fluidized bed operation. Such acoustic monitors have shown that they are especially sensitive to the presence of very fine particles in the bed of less than 50 microns diameter. Acoustic monitors for particle size and bed friction damping will be very useful in any fluidized bed, especially fluidized beds where particle size changes. The fluidized bed friction damping depends on many other bed properties besides particle size such as bed height, density, SSV, void fraction, gas viscosity, and fluidization scheme and so acoustic bed friction should also be useful for monitoring other bed properties besides particle size. In fact, the change in the static bed friction slope with SSV upon fluidization follows the Ergun function and reveals a minimum fluidization velocity for each HMPD. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Background dust emission following grassland fire: a snapshot across the particle-size spectrum highlights how high-resolution measurements enhance detection

Dust emission rates vary temporally and with particle size. Many studies of dust emission focus on a particular temporal scale and the portion of the particle-size spectrum associated with a single instrument; fewer studies have assessed dust emission across the particle-size spectrum and associated temporal scales using multiple instruments. Particularly lacking are measurements following disturbances such as fire that are high-resolution and focused on finer particles - those with direct implications for human health and potential for long-distance biogeochemical transport - during less windy but more commonly occurring background conditions. We measured dust emissions in unburned and burned semiarid grassland using four different instruments spanning different combinations of temporal resolution and particle-size spectrum: Big Springs Number Eight (BSNE) and Sensit instruments for larger saltating particles, DustTrak instruments for smaller suspended particles, and Total Suspended Particulate (TSP) samplers for measuring the entire range of particle sizes. Unburned and burned sites differed in vegetation cover and aerodynamic roughness, yet surprisingly differences in dust emission rates were only detectable for saltation using BSNE and for smaller aerosols using DustTrak. Our results, surprising in the lack of consistently detected differences, indicate that high-resolution DustTrak measurements offered the greatest promise for detecting differences in background emission rates and that BSNE samplers, which integrate across height, were effective for longer intervals. More generally, our results suggest that interplay between particle size, temporal resolution, and integration across time and height can be complex and may need to be considered more explicitly for effective sampling for background dust emissions.

54 ENVIRONMENTAL SCIENCES↗

Size-dependent magnetic properties of highoxygen content YMn2O5+-x multiferroic nanoparticles

The effect of particle size on magnetic properties in single-crystalline multiferroic YMn{sub 2}O{sub 5.07} nanoparticles was investigated. A modified Pechini's method was employed to synthesize YMn{sub 2}O{sub 5.07} powders with different particle sizes under an atmosphere of 10 bar O{sub 2}. It was found that the multiferroic YMn{sub 2}O{sub 5.07} compound displays a profound size dependence in its magnetic properties when the particles were smaller than 160 nm. With a decrease in particle size, a ferromagnetic-like phase with a broad transition emerges and the transition temperature increases. This ferromagnetic-like phase might be attributed to the surface layer of the nanoparticles and the broad magnetic transition could be caused by the dispersion of particle size and the size dependence of the transition temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of Sludge Particle Size and Density on Hanford Waste Processing

The U.S. Department of Energy Office of River Protection’s Waste Treatment and Immobilization Plant (WTP) will process and treat radioactive waste that is stored in tanks at the Hanford Site in southeastern Washington State. Piping and pumps have been selected to transport the high-level waste (HLW) slurries in the WTP. Pipeline critical-velocity calculations for these systems require the input of a bounding particle size and density. Various approaches based on statistical analyses have been used in the past to provide an estimate of this bounding size and density. In this paper, representative particle size and density distributions (PSDDs) of Hanford waste insoluble solids have been developed based on a new approach that relates measured particle-size distributions (PSDs) to solid-phase compounds. This work was achieved through extensive review of available Hanford waste PSDs and solid-phase compound data. Composite PSDs representing the waste in up to 19 Hanford waste tanks were developed, and the insoluble solid-phase compounds for the 177 Hanford waste tanks, their relative fractions, crystal densities, and particle size and shape were developed. With such a large combination of particle sizes and particle densities, a Monte Carlo simulation approach was used to model the PSDDs. Further detail was added by including an agglomeration of these compounds where the agglomerate density was modeled with a fractal dimension relation. The Monte Carlo simulations were constrained to hold the following relationships: 1) the composite PSDs are reproduced, 2) the solid-phase compound mass fractions are reproduced, 3) the expected in situ bulk-solids density is qualitatively reproduced, and 4) a representative fraction of the sludge volume comprising agglomerates is qualitatively reproduced to typical Hanford waste values. Four PSDDs were developed and evaluated. These four PSDD scenarios correspond to permutations where the master PSD was sonicated or not-sonicated before being analyzed and whether agglomerates existed or not in the PSD samples. When critical pipeline velocity calculations are applied to these results, several percent of Hanford tank waste sludge are expected to exceed pipeline velocities of <3 to 4 ft/sec. Operation and waste processing at pipeline velocities in the >4 to 6 ft/sec range appear to be compatible with the Hanford sludge in 3-inch pipes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗