Contactless Production Testing of Silicon Solar Cells

Critical cost reductions in silicon solar cells are made by minimizing silver usage in their metal contacts. The reason why is both clear and unavoidable—silver is not only expensive, but also a potential limiting resource for scale-up (the PV industry alone used 10.3 % of the global silver supply in 2020 [1]). The result is solar cells with vanishing electrical contact area that are extremely difficult to test prior to module manufacture, when they must be sorted for quality to maximize power output and reliability of the subsequent modules. This project developed a new measurement instrument that enables the transition to solar cells with very low silver content, including cell designs with both minimal busbars and no busbars at all to electrically contact. The resulting instrument at project completion demonstrated the ability to sort cells with comparable—or better—results than existing technology. Compared to existing cell-test instruments, the new tool has minimal contacting requirements, which lowers the maintenance costs and use of consumable parts. We demonstrated innovative, yet pragmatic, solutions for reporting a comprehensive set of measurement results useful for both cell sorting (going forward in the line for module manufacture) and process control (looking backward in the line to identify cell manufacturing issues from wafer to cell-test). In addition to the traditional current-voltage characterization at cell test—short circuit current, open-circuit voltage, power, efficiency and fill factor—the new tool maintains all the advanced parameter characterization of our existing product line such as a substrate doping measurement, carrier recombination (lifetime) analysis, and surface recombination analysis.

14 SOLAR ENERGY↗

Gain of Object/Slot Array On Infinite Cylinder Operating At Fundamental Cavity Modes

This report examines the coupling into a circumferential slot array on an infinite cylinder with a finite length interior cavity operating at the fundamental cavity modal frequencies. The directivity gain associated with the interior cavity field is examined, and in this frequency range (as well as lower frequencies), is found to be enhanced by the exterior short circuit current variation with angle driving the slots.

42 ENGINEERING↗

Elucidating the Morphological Instability Mechanisms During Electrodeposition of Active Metals

The primary aim of this investigation is to elucidate the mechanisms by which a group of metals pertinent to battery technology exhibit unstable growth morphology during electrodeposition, which are crucial for the operational efficacy of batteries. The metals under consideration include alkali metals alongside zinc, all of which are characterized by high atomic mobility and reactivity with the electrolytes employed in battery systems. These materials represent promising electrode candidates for next-generation rechargeable batteries that are anticipated to deliver significantly enhanced energy density at a reduced cost. Nevertheless, the widespread occurrence of distinctly non-uniform morphologies, exemplified by the emergence of filamentous and moss-like structures, constitutes a significant impediment to their effective utilization, as it leads to accelerated capacity degradation and potential internal short circuits. This study addresses a critical question that has thus far garnered limited attention: Does the residual stress induced by the plating process play an instrumental role in inducing the morphological instability? Utilizing zinc as the primary model system, this project will be executed through three interconnected tasks: (1) the quantification of the relationship between plating stress and electroplating morphologies, (2) the three-dimensional imaging of the microstructure of the mossy structure at the nanoscale, and (3) the development of a mesoscale electroplating model to interpret empirical findings and generate additional predictive insights.

25 ENERGY STORAGE↗

Photovoltaic Mini-Module Soiling Stations: Cooperative Research and Development (Final Report)

Photovoltaic (PV) panels can become soiled due to a variety of environmental factors. This soiling reduces the amount of light reaching the cells and thus their energy output. The ratio of actual output of the soiled device that of a clean device is known as the soiling ratio. The daily change in soiling ratio is known as the soiling rate. To study soiling for different glass coatings. Two soiling stations were fabricated. The stations were designed to monitor the short-circuit current of PV cells encapsulated with glass featuring different coatings and measure the daily soiling ratio with a pair of reference cells, one of which is automatically brushed daily. This work meets the need to understand how the glass coatings perform in additional environments. The stations are designed to quantify both the soiling ratio (the ratio between actual/expected photovoltaic panel power output) as well as differences in anti-soiling performance of different glass coatings. The design of the dirty/clean reference cell system is described by Toth et al. The soiling ratio is calculated by calculating the average irradiance measured within one hour of solar noon by each of the reference cells and then taking the ratio of these daily near-noon averages. The soiling ratio time series for the station deployed in Georgia is shown in Figure 1. This figure shows that the soiling ratio at the site has not yet fallen below 0.99, indicating that peak daily soiling losses have been below 1%. The site was chosen because it is thought to be affected by pollen soiling. With continued monitoring over the course of at least a full year, we expect to be able to observe and quantify pollen soiling events.

14 SOLAR ENERGY↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Lithium Growth on Alloying Substrates and Effect on Volumetric Expansion

The widespread implementation of next-generation Li metal anodes is limited, in part, due to the formation of dendritic and/or mossy electrodeposits during cycling. These morphologies can lead to battery failure due to the formation of short circuits and significant volumetric expansion at the anode. One strategy to control the electrodeposition of Li metal is to use lithiophilic materials at the anode. Here, we evaluate the impact of Ag and Au on the early stages of Li metal electrodeposition and cycling. The alloying substrates decrease the voltage for Li reduction and improve Li wetting/adhesion. We probe volumetric expansion directly through dilatometry measurements and find that the degree of volumetric expansion is less when lithium is cycled on an alloying substrate compared to a non-alloying substrate (Cu). Dilatometry experiments reveal that Au has the least amount of volumetric expansion and coin cell cycling experiments indicate that Ag yields more stable cycling compared to Au or Cu. The evaluation of in situ cross-sectional images of cycled coin cells shows that Ag has the lowest volumetric expansion in a coin cell format.

alloys↗

Real-Time Fault Location Using the Retardation Method

A new method for short-circuit fault location is proposed. The method is based on instantaneous signal measurement and its first and second derivatives, which are the novel elements of the current approach. The derivatives allow associating a precise time stamp to the occurrence of the fault. Due to retardation phenomena, the difference between the times in which a signal is registered in two detectors can be used to locate the fault. We offer several mathematical models to describe the fault. Although a description of faults in terms of a lumped circuit is useful for elucidating the methods for detecting the fault, this description will not suffice to describe the fault signal propagation; hence, a distributed models is needed, which is given in terms of the telegraph equations. Those equations were used to derive a transmission line transfer function, and an exact analytical description of the fault signal propagating in the transmission line was obtained. The analytical solution was verified both by numerical simulations and experimentally.

42 ENGINEERING↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing

An in-situ method is proposed for monitoring and estimating the power degradation of mc-Si photovoltaic (PV) modules undergoing thermo-mechanical degradation tests that primarily manifest through cell cracking, such as mechanical load tests, thermal cycling and humidity freeze tests. The method is based on in-situ measurement of the module’s dark current-voltage (I-V) characteristic curve during the stress test, as well as initial and final module flash testing on a Sun simulator. The method uses superposition of the dark I-V curve with final flash test module short-circuit current to account for shunt and junction recombination losses, as well as series resistance estimation from the in-situ measured dark I-Vs and final flash test measurements. The method is developed based on mc-Si standard modules undergoing several stages of thermo-mechanical stress testing and degradation, for which we investigate the impact of the degradation on the modules light I-V curve parameters, and equivalent solar cell model parameters. Experimental validation of the method on the modules tested shows good agreement between the in-situ estimated power degradation and the flash test measured power loss of the modules, of up to 4.31 % error (RMSE), as the modules experience primarily junction defect recombination and increased series resistance losses. However, the application of the method will be limited for modules experiencing extensive photo-current degradation or delamination, which are not well reflected in the dark I-V characteristic of the PV module.

14 SOLAR ENERGY↗

Use of Hydrogel Electrolyte in Zn-MnO2 Rechargeable Batteries: Characterization of Safety, Performance, and Cu2+ Ion Diffusion

Achieving commercially acceptable Zn-MnO2 rechargeable batteries depends on the reversibility of active zinc and manganese materials, and avoiding side reactions during the second electron reaction of MnO2. Typically, liquid electrolytes such as potassium hydroxide (KOH) are used for Zn-MnO2 rechargeable batteries. However, it is known that using liquid electrolytes causes the formation of electrochemically inactive materials, such as precipitation Mn3O4 or ZnMn2O4 resulting from the uncontrollable reaction of Mn3+ dissolved species with zincate ions. In this paper, hydrogel electrolytes are tested for MnO2 electrodes undergoing two-electron cycling. Improved cell safety is achieved because the hydrogel electrolyte is non-spillable, according to standards from the US Department of Transportation (DOT). The cycling of “half cells” with advanced-formulation MnO2 cathodes paired with commercial NiOOH electrodes is tested with hydrogel and a normal electrolyte, to detect changes to the zincate crossover and reaction from anode to cathode. These half cells achieved ≥700 cycles with 99% coulombic efficiency and 63% energy efficiency at C/3 rates based on the second electron capacity of MnO2. Other cycling tests with “full cells” of Zn anodes with the same MnO2 cathodes achieved ~300 cycles until reaching 50% capacity fade, a comparable performance to cells using liquid electrolyte. Electrodes dissected after cycling showed that the liquid electrolyte allowed Cu ions to migrate more than the hydrogel electrolyte. However, measurements of the Cu diffusion coefficient showed no difference between liquid and gel electrolytes; thus, it was hypothesized that the gel electrolytes reduced the occurrence of Cu short circuits by either (a) reducing electrode physical contact to the separator or (b) reducing electro-convective electrolyte transport that may be as important as diffusive transport.

25 ENERGY STORAGE↗

Random Forest Regressor-Based Approach for Detecting Fault Location and Duration in Power Systems

Power system failures or outages due to short-circuits or “faults” can result in long service interruptions leading to significant socio-economic consequences. It is critical for electrical utilities to quickly ascertain fault characteristics, including location, type, and duration, to reduce the service time of an outage. Existing fault detection mechanisms (relays and digital fault recorders) are slow to communicate the fault characteristics upstream to the substations and control centers for action to be taken quickly. Fortunately, due to availability of high-resolution phasor measurement units (PMUs), more event-driven solutions can be captured in real time. In this paper, we propose a data-driven approach for determining fault characteristics using samples of fault trajectories. A random forest regressor (RFR)-based model is used to detect real-time fault location and its duration simultaneously. This model is based on combining multiple uncorrelated trees with state-of-the-art boosting and aggregating techniques in order to obtain robust generalizations and greater accuracy without overfitting or underfitting. Four cases were studied to evaluate the performance of RFR: 1. Detecting fault location (case 1), 2. Predicting fault duration (case 2), 3. Handling missing data (case 3), and 4. Identifying fault location and length in a real-time streaming environment (case 4). A comparative analysis was conducted between the RFR algorithm and state-of-the-art models, including deep neural network, Hoeffding tree, neural network, support vector machine, decision tree, naive Bayesian, and K-nearest neighborhood. Experiments revealed that RFR consistently outperformed the other models in detection accuracy, prediction error, and processing time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Polarization-dependent conversion efficiency of carbon nanotube-Si heterojunction solar cells based on aligned carbon nanotube films

We have fabricated solar cells that implement heterojunctions of Si and aligned carbon nanotube (CNT) films. Polarization-dependent optical absorption of highly aligned CNTs led to polarization-dependent conversion efficiencies, which in turn provided insight into the role of the CNT layer in the power generation mechanism in these heterojunction solar cells. When the incident light polarization was parallel to the CNT alignment direction so that the light absorption in the CNT layer was maximized, the short circuit photocurrent decreased by ~25%. This indicates that electron–hole pair generation in the CNT layer does not directly lead to power generation and that the CNT-Si heterojunctions in our devices are Schottky junctions rather than p–n junctions.

Physics↗

Generic characterization of electrical test benches for AC- and HVDC-connected wind power plants

The electrical test and assessment of wind turbines go hand in hand with standards and network connection requirements. In this paper, the generic structure of advanced electrical test benches, including grid emulator or controllable grid interface, wind torque emulator, and device under test, is proposed to harmonize state-of-the-art test sites. On the other hand, modern wind turbines are under development towards new features, concerning grid-forming, black-start, and frequency support capabilities as well as harmonic stability and control interaction considerations, to secure the robustness and stability of renewable-energy-based power systems. Therefore, it is necessary to develop new and revised test standards and methodologies to address the new features of wind turbines. This paper proposes a generic test structure within two main groups, including open-loop and closed-loop tests. The open-loop tests include the IEC 61400-21-1 standard tests as well as the additional proposed test options for the new capabilities of wind turbines, which replicate grid connection compliance tests using open-loop references for the grid emulator. In addition, the closed-loop tests evaluate the device under test as part of a virtual wind power plant and perform real-time simulations considering the grid dynamics. The closed-loop tests concern grid connection topologies consisting of AC and HVDC, as well as different electrical characteristics, including impedance, short-circuit ratio, inertia, and background harmonics. The proposed tests can be implemented using available advanced test benches by adjusting their control systems. The characteristics of a real power system can be emulated by a grid emulator coupled with real-time digital simulator systems through a high-bandwidth power-hardware-in-the-loop interface.

17 WIND ENERGY↗

Carbon Dioxide Reduction Systems

The Methoxy system for regenerating oxygen from carbon dioxide was studied. Experiments indicate that the reaction between carbon dioxide and hydrogen can be carried out with ease in an efficient manner and with excellent heat conservation. A small reactor capable of handling the C02 expired by three men has been built and operated. The decomposition of methane by therma1,arc and catalytic processes was studied. Both the arc and catalytic processes gave encouraging results with over 90 percent of the methane being decomposed to carbon and hydrogen in some of the catalytic processes. Control of the carbon deposition in both the catalytic and arc processes is of great importance to prevent catalyst deactivation and short circuiting of electrical equipment. Sensitive analytical techniques have been developed for all of the components present in the reactor effluent streams.

METHOXY SYSTEM↗

Semiconductors can be tested without removing them from circuitry

Oscilloscope, with specially developed test circuitry, quickly checks semiconductors without removing them from the circuitry. For transistors, approximate gain and linearity, as well as PNP or NPN determinations are made. When testing diodes, open or short circuits, and reverse polarity show up plainly.

Allen, B. C.↗