Analysis of Phase Transformation Studies in Solute Addition Alloys

Components serving in a nuclear reactor plant must withstand a very harsh environment including extended time at elevated temperatures, neutron irradiation, stress, and/or corrosive media. The many modes of degradation are complex and very depending on material and service locations. However, understanding and managing materials degradation is paramount for the continued safe and reliable operation of nuclear power plants. For the reactor core and primary systems, several key areas have been identified. Thermomechanical considerations such as aging and fatigue must be examined. Irradiation-induced processes must also be considered for higher fluences under the life extension consideration of the current light water reactors (LWRs), which particularly includes the influence of radiation-induced segregation (RIS), swelling, and precipitation on component hardening and embrittlement. Corrosion takes many forms within the reactor core, although irradiation-assisted stress corrosion cracking (IASCC) and primary water stress corrosion cracking (PWSCC) are of high interest in extended life scenarios. Research in these areas can build upon other ongoing programs in the LWR industry as well as other reactor materials programs (such as fusion and fast reactors) to help resolve these issues for extended LWR life. Type 304 and 316 stainless steels are classic structural materials used in LWRs. A set of well designed type 304 and 316 variants by changing the amount of a single solute element were irradiated using the BOR-60 fast breeder reactor at ~320°C in Russia. This set of alloy samples has been used in this task to characterize detailed microstructural evolution and measure magnetic phase, swelling and hardness. This report summarizes the detailed microstructural results, characterized using conventional and scanning transmission electron microscopy (CTEM/STEM) and energy dispersive X-ray spectroscopy (EDS), and the newly developed model of strength factor for estimating radiation hardening. The results provide invaluable insights into understanding degradation mechanisms of key components and assists in the prediction of the life of similar materials and the base knowledge required to develop advanced radiation resistant alloys. The effect of solute elements on microstructural evolution under neutron irradiation is explored. The approximate correlation between microstructure changes and radiation hardening is established. The major results and implications are discussed below.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Research on the Corrosion Behavior of X70 Pipeline Steel Under Coupling Effect of AC + DC and Stress

The coupling effect of stray AC (alternating current) + DC (direct current) and tensile stress-induced X70 pipeline corrosion is complicated with its mechanism uncovered. In this work, the corrosion behavior of X70 pipeline steel under three different corrosion (including an individual AC corrosion, mixed AC + 150 MPa tensile stress corrosion, coupling effect of AC + a 30 A/m{sup 2} DC interference and 150 MPa tensile stress corrosion) conditions in Dagang soil simulated solution was investigated by COMSOL Multiphysics software simulation, electrochemical tests, scanning electron microscope and other techniques. The results indicated that with the increase in AC density, the open-circuit potential of the X70 steel samples was negatively shifted and corrosion rate increased in three different corrosion conditions. The corrosion rates of X70 steel samples under individual AC interference were almost unchanged when 150.9 MPa tensile stress was applied. When applying 30 A/m{sup 2} DC interference, the corrosion rate of X70 steel increases significantly. Therefore, the factors affecting corrosion performance of X70 pipeline steel were DC > AC > stress. Under individual AC interference, uniform corrosion occurred on the X70 steel at an AC current density of less than 30 A/m{sup 2}, while the pitting corrosion occurred at an AC current density of greater than 100 A/m{sup 2}. The application of tensile stress and DC had a certain inhibitory effect on pitting corrosion.

36 MATERIALS SCIENCE↗

Effect of Laser Shock Peening on Residual Stress, Microstructure and Hot Corrosion Behavior of Damage-Tolerant TC21 Titanium Alloy

The effect of laser shock peening (LSP) on the residual stress, microstructure and hot corrosion behavior of damage-tolerant TC21 alloy was investigated. The equilateral scanning pattern was adopted to obtain a large overlapping area for LSP. The hot corrosion experiments in a salt mixture composed of 75 wt.% Na{sub 2}SO{sub 4} + 25 wt.% NaCl at 700 and 800 °C for a total exposure of 25 h were conducted. The results demonstrated that LSP caused a high compressive residual stress with a significant increase in micro-hardness and microstructural changes in the form of crystal defects, i.e., high density dislocations. The crystal defects promoted the outward diffusion of Al, Cr and Ti to form protective mixed oxides (Al, Cr, Ti)O{sub 2}. These oxides improved the adhesion of outer oxide layer and hindered the inward diffusion of O, S and Cl, which was beneficial to improve hot corrosion resistance. The mass gains of LSP-treated specimens after hot corrosion at 700 and 800 °C were, respectively, 3.72 and 4.78 mg/cm{sup 2}, which were much lower than those of untreated specimens (5.65 and 6.81 mg/cm{sup 2}). Therefore, LSP leads to an improvement in resistance to hot corrosion of TC21 alloy.

36 MATERIALS SCIENCE↗

Risk Based Corrosion Studies at SRS

Elizabeth Hoffman presents an overview of risk based corrosion studies done at SRS with the goals of improved control in the processes and tank design. .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A nanomechanical Raman spectroscopy based assessment of stress distribution in irradiated and corroded SiC

Silicon carbide (SiC) composites are under consideration for cladding and structural materials in various types of reactors. The effects of ion irradiation and corrosion on stress distribution due to mechanical loading on chemical vapor deposited (CVD) SiC were investigated here in this paper by using nanomechanical Raman spectroscopy (NMRS). The stress distribution was analyzed as a function of the oxide formation on a corroded specimen and as a function of ion-induced irradiation damage in an irradiated specimen. A finite element method (FEM) based model was developed based on local mechanical properties measured using nanoindentation to predict the NMRS measured stress distribution. The stress distribution was also predicted theoretically by using a stress concentration factor, which is a function of sample geometry and boundary conditions. The maximum stress obtained theoretically was in good agreement with the FEM model and NMRS based measurements. FEM results captured the stress variation trends and maximum stress value in the analyzed samples. NMRS measurements predicted that corrosion had a greater influence on increasing the maximum value of stress in comparison to ion irradiation. The increase in stress attributed to corrosion in comparison to ion irradiated samples was approximately 10%–20%.

36 MATERIALS SCIENCE↗

Effect of Applied Stress on the Selective Oxidation of Alloy 600 Exposed to PWR Primary Water and Rhines Pack Environments

A mechanistic understanding of corrosion and oxidation processes is crucial to ensure long-term resistance to stress corrosion cracking of Ni-base structural alloys in pressurized water reactor (PWR) primary and secondary systems. Aqueous corrosion of Ni-base alloys under PWR primary water conditions was previously compared to gaseous oxidation with comparable oxygen potentials. However, those studies considered only stress-free conditions, which removes a critical parameter for understanding stress corrosion behaviors. A significant knowledge gap exists for the role of applied stresses on selective internal oxidation in gaseous environments. A micro-4-point-bend jig was designed to facilitate stress in a Rhines Pack set-up. Selective oxidation at different stress and strain conditions was investigated in a series of Rhines Pack experiments for Alloy 600. Focused ion beam milling enabled the extraction of site-specific specimens containing selected high-energy grain boundaries from tensile and compressive stress regions. Analytical transmission electron microscopy was employed to analyze the microstructure and chemical composition of the resulting oxides. Protective surface oxide films and selective intergranular oxides were observed at different conditions. The implications of these fundamental differences are discussed relative to intergranular attack and stress corrosion cracking mechanisms in PWR primary water.

stress, 4-point-bend, selective oxidation, Alloy 6↗

Corrosion Behavior of Aqua-Blasted and Laser-Engraved Type 316L Stainless Steel

The effect of aqua blasting and laser engraving on surface microstructure development, residual stress and corrosion resistance of type 316L stainless steel has been investigated. Aqua blasting resulted in a deformed near-surface microstructure containing compressive residual stresses. Subsequent laser engraving produced a surface layer with tensile residual stresses reaching to a depth of 200 microns. Changes of surface roughness topography were accompanied by the development of a thick oxide/hydroxide film after laser engraving. The atmospheric corrosion behavior of all surfaces with MgCl{sub 2}-laden droplets was compared to their electrochemical response in 1M NaCl and 0.7 M HCl aqueous solutions. The measured total volume loss after atmospheric corrosion testing was similar for all investigated surface conditions. Laser-engraved surface exhibited the smallest number of corrosion sites, but the largest mean corrosion depth.

36 MATERIALS SCIENCE↗

Mechanical Properties and Corrosion Behavior of Spray-Formed 7075 Alloy with One-Stage Aging

The mechanical properties, corrosion resistance and microstructure of the spray-formed 7075 alloy after one-stage aging treatments were studied by using a tensile tester, hardness tester, slow strain rate test, electrical test, intergranular corrosion test, electrochemical corrosion test, scanning electron microscope and transmission electron microscope. The results show that the strength and hardness of the alloy have double peaks with the one-stage aging treatments. With aging at 120 °C for 24 h (first peak), abundant tiny η′ phases and η phases precipitate in the matrix. The tensile strength of the alloy increases to 760 MPa, and the elongation is 4.8%. After aging at 120 °C for 132 h (second peak), blocky η phases appear. The tensile strength and elongation of the alloy are 757 MPa and 5.9%, respectively. The grain boundary precipitates dissociate, and the precipitate-free zones are widened. The corrosion resistance of the alloy increases.

36 MATERIALS SCIENCE↗

Friction Stir Welding of Dissimilar Al/Al and Al/Non-Al Alloys: A Review

Friction stir welding is a solid-state welding technique that has many advantages over traditional fusion welding, and has been widely adopted in the aerospace and automotive industries. This article reviews research developments in friction stir welding of dissimilar alloys systems, including combinations of aluminum alloys with Mg alloys, Cu, and steel. Microstructural evolution, hardness, tensile and fatigue properties, residual stresses, and corrosion behavior of dissimilar welds will be reported. The effects of processing parameters such as tool rotation and traverse speeds, tool position, material position, and tool geometry on the weld quality are also presented. Discussions on future research directions in friction stir welding will also be provided in the context of existing literature and future high-integrity applications.

36 MATERIALS SCIENCE↗

Electrochemical Behavior of Biomedical Titanium Alloys Coated with Diamond Carbon in Hanks’ Solution

Biomedical implants in the knee and hip are frequent failures because of corrosion and stress on the joints. To solve this important problem, metal implants can be coated with diamond carbon, and this coating plays a critical role in providing an increased resistance to implants toward corrosion. In this study, we have employed diamond carbon coating over Ti-6Al-4V and Ti-13Nb-13Zr alloys using hot filament chemical vapor deposition method which is well-established coating process that significantly improves the resistance toward corrosion, wears and hardness. The diamond carbon-coated Ti-13Nb-13Zr alloy showed an increased microhardness in the range of 850 HV. Electrochemical impedance spectroscopy and polarization studies in SBF solution (simulated body fluid solution) were carried out to understand the in vitro behavior of uncoated as well as coated titanium alloys. The experimental results showed that the corrosion resistance of Ti-13Nb-13Zr alloy is relatively higher when compared with diamond carbon-coated Ti-6Al-4V alloys due to the presence of β phase in the Ti-13Nb-13Zr alloy. Electrochemical impedance results showed that the diamond carbon-coated alloys behave as an ideal capacitor in the body fluid solution. Moreover, the stability in mechanical properties during the corrosion process was maintained for diamond carbon-coated titanium alloys.

36 MATERIALS SCIENCE↗

Effects of Co contents on the microstructures and properties of the electrodeposited NiCo–Zr composite coatings

Highlights: • The novel NiCo–Zr coatings were prepared by electro-deposition. • Surface morphology, crystal structure, grain size and microstrain were examined. • Texture, residual stress and corrosion resistance were investigated. • Addition of Co increased the hardness and corrosion resistance of the coatings. - Abstract: In this study, the NiCo–Zr composite coatings were prepared from the electrolytes with different Co{sup 2+} concentrations by electrodeposition method. The effects of Co contents on the crystal structure, surface morphology, grain size, microstrain and residual stress were examined by X-ray diffractometer (XRD), field emission scanning electron microscopy (FESEM), Energy dispersive X-ray spectroscopy (EDX) and atomic force microscope (AFM). The corrosion resistance of the composite coatings was also examined by the potentiodynamic polarization and electrochemical impedance (EIS) measurements. The results revealed that the crystal structures of the coatings were dependent on the Co contents and addition of Co content of 58 wt% resulted in the formation of hexagonal (hcp) Co. The increasing Co contents in the NiCo–Zr composite coatings resulted in the smoother and more compact surface, decreased the grain size and increased the microstrain. The micro-hardness and residual stress also increased with increasing Co contents. The addition of Co increased the corrosion resistance of the NiCo–Zr composite coatings compared with the Ni–Zr coating while the corrosion resistance of the NiCo–Zr composite coatings decreased as the Co contents increased.

36 MATERIALS SCIENCE↗

Corrosion test of LWR cladding tubes in high temperature seawater

In the case of cooling system failure in spent fuel pools (SFP) due to station black out and/or loss of coolant accidents, a pool water level must be kept high enough to avoid overheat of spent fuels. Seawater is one of the candidate coolant materials in such emergencies. In the present work, we have studied the corrosion behavior of zirconium alloys in seawater. Tube samples of Zircaloy-2 and -4 claddings were immersed in artificial seawater (3, 10 and 20 wt.%) at high temperature (80 - 85 Celsius degrees). Boric acid was added to the seawater at a corrosion test of Zircaloy-4. Two types of specimens were prepared according to the simulation of circumferential tensile stress. One was a plugged tube specimen, which was pressurized to around fuel rod pressure in a spent fuel pool by argon gas. Another specimen was of C-ring shape, where large circumferential tensile stress was partially induced at the surface. A notch was longitudinally grooved to increase the local tensile stress on some of the C-ring specimens. The specimen surface was observed by a scanning electron microscopy (SEM) after the corrosion test. After the 200 day long corrosion test for the plugged tube specimens without boric acid, Mg(OH){sub 2} deposits were observed on the surface of Zircaloy-2 and -4 specimens whereas Mg(OH){sub 2} was not observed with boric acid because of probably a lower pH. Neither pitting corrosion nor stress corrosion cracking (SCC) was observed on the surface of all plugged tube specimens. Only in the C-ring specimens in 20 wt.% seawater without boric acid and in 3 and 10 wt.% seawater with boric acid, small cracks were observed at the notch. The results of the present work show that Zircaloy-2 and -4 have a high tolerance towards corrosion and SCC in high temperature seawater.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of failed and nickel-coated 3093 beam clamp components at the East Tennessee Technology Park (ETTP).

The U.S. Department of Energy and its contractor, Bechtel Jacobs Company (BJC), are undertaking a major effort to clean up the former gaseous diffusion facility (K-25) located in Oak Ridge, TN. The decontamination and decommissioning activities require systematic removal of contaminated equipment and machinery followed by demolition of the buildings. As part of the cleanup activities, a beam clamp, used for horizontal life lines (HLLs) for fall protection, was discovered to be fractured during routine inspection. The beam clamp (yoke and D-ring) was a component in the HLL system purchased from Reliance Industries LLC. Specifically, the U-shaped stainless steel yoke of the beam clamp failed in a brittle mode at under less than 10% of the rated design capacity of 14,500 lb. The beam clamp had been in service for approximately 16 months. Bechtel Jacobs approached Argonne National Laboratory to assist in identifying the root cause of the failure of the beam clamp. The objectives of this study were to (1) review the prior reports and documents on the subject, (2) understand the possible failure mechanism(s) that resulted in the failed beam clamp components, (3) recommend approaches to mitigate the failure mechanism(s), and (4) evaluate the modified beam clamp assemblies. Energy dispersive x-ray analysis and chemical analysis of the corrosion products on the failed yoke and white residue on an in-service yoke indicated the presence of zinc, sulfur, and calcium. Analysis of rainwater in the complex, as conducted by BJC, indicated the presence of sulfur and calcium. It was concluded that, as a result of galvanic corrosion, zinc from the galvanized components of the beam clamp assembly (D-ring) migrated to the corroded region in the presence of the rainwater. Under mechanical stress, the corrosion process would have accelerated, resulting in the catastrophic failure of the yoke. As suggested by Bechtel Jacobs personnel, hydrogen embrittlement as a consequence of corrosion was also explored as a failure mechanism. Corroded and failed yoke samples had hydrogen concentrations of 20-60 ppm. However, the hydrogen content reduced to 4-11 ppm (similar to baseline as-received yoke samples) when the corrosion products were polished off. The hydrogen content in the scraped off corrosion product powders was >7000 ppm. These results indicate that hydrogen is primarily present in the corrosion products and not in the underlying steel. Rockwell hardness values on the corroded yoke and D-rings were R{sub c} {approx} 41-46. It was recommended to the beam clamp manufacturer that the beam clamp components be annealed to reduce the hardness values so that they are less susceptible to brittle failure. Upon annealing, hardness values of the beam clamp components reduced to R{sub c} {approx} 25. Several strategies were recommended and put in place to mitigate failure of the beam clamp components: (a) maintain hardness levels of both yokes and D-rings at R{sub c} < 35, (b) coat the yoke and D-rings with a dual coating of nickel (with 10% phosphorus) to delay corrosion and aluminum to prevent galvanic corrosion since it is more anodic to zinc, and (c) optimize coating thicknesses for nickel and aluminum while maintaining the physical integrity of the coatings. Evaluation of the Al- and Ni-coated yoke and D-ring specimens indicated they appear to have met the recommendations. Average hardness values of the dual-coated yokes were R{sub c} {approx} 25-35. Hardness values of dual-coated D-ring were R{sub c} {approx} 32. Measured average coating thicknesses for the aluminum and nickel coatings for yoke samples were 22 {micro}m (0.9 mils) and 80 {micro}m (3 mils), respectively. The D-rings also showed similar coating thicknesses. Microscopic examination showed that the aluminum coating was well bonded to the underlying nickel coating. Some observed damage was believed to be an artifact of the cutting-and-polishing steps during sample preparation for microscopy.

08 HYDROGEN↗

Quantifying Optical Loss of High-Voltage Degradation Modes in PV Modules Using Spectral Analysis [Slides]

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative ("HV-") and positive ("HV+") polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including: corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (SixNy) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85 degrees C/85% relative humidity included: spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the SixNy coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared to a mini-module previously subjected to HV-/HV+ stress. The model suggests one-third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the SixNy coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.