Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

A fast and reliable readout method for quantitative analysis of surface-enhanced Raman scattering nanoprobes on chip surface

Surface-enhanced Raman scattering techniques have been widely used for bioanalysis due to its high sensitivity and multiplex capacity. However, the point-scanning method using a micro-Raman system, which is the most common method in the literature, has a disadvantage of extremely long measurement time for on-chip immunoassay adopting a large chip area of approximately 1-mm scale and confocal beam point of ca. 1-μm size. Alternative methods such as sampled spot scan with high confocality and large-area scan method with enlarged field of view and low confocality have been utilized in order to minimize the measurement time practically. In this study, we analyzed the two methods in respect of signal-to-noise ratio and sampling-led signal fluctuations to obtain insights into a fast and reliable readout strategy. On this basis, we proposed a methodology for fast and reliable quantitative measurement of the whole chip area. The proposed method adopted a raster scan covering a full area of 100 μm × 100 μm region as a proof-of-concept experiment while accumulating signals in the CCD detector for single spectrum per frame. One single scan with 10 s over 100 μm × 100 μm area yielded much higher sensitivity compared to sampled spot scanning measurements and no signal fluctuations attributed to sampled spot scan. This readout method is able to serve as one of key technologies that will bring quantitative multiplexed detection and analysis into practice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of magnetic parameters in La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/SrTiO{sub 3} thin films using EMCD

It is well known that the magnetic state of the La{sub 0.7}Sr{sub 0.3}MnO{sub 3} (LSMO) thin-film heterostructure is strongly correlated with the lattice, spin, orbital, and charge states, since these influence the electric and magnetic transport properties even on the unit-cell level. Therefore, understanding the material's magnetic properties on the nanoscale is important for the development of novel applications. The recently developed electron magnetic-circular dichroism (EMCD) technique allows the determination of atomic site-specific magnetic information via the use of transmitted electrons; however, its sensitivity is not high enough to quantitatively acquire magnetic information in many weak magnetism systems. Here, we utilized a dynamical diffraction-effect assisted EMCD technique to quantitatively determine the spin and orbital magnetic moment of LSMO/SrTiO{sub 3} thin films on the nanometer scale using a transmission electron microscope. Further, data processing was optimized to enhance the intensity of the EMCD signals for manganese, which have very weak magnetism at room temperature. High signal-to-noise ratio and accurate quantitative magnetic measurement are eventually achieved. Finally, the spin magnetic moments (0.73 ± 0.26 μ{sub B}) are derived, and we also limited the ratio of the orbital to spin magnetic moment within an interval of (−0.03, 0.01). Our results not only present the nanoscale magnetic parameters of LSMO/SrTiO{sub 3}, but also demonstrate how the measurement limit of the spin (or orbital) magnetic moment can be achieved, which is via the developed dynamical diffraction effect assisted EMCD technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FOREVER ALONE? TESTING SINGLE ECCENTRIC PLANETARY SYSTEMS FOR MULTIPLE COMPANIONS

Determining the orbital eccentricity of an extrasolar planet is critically important for understanding the system's dynamical environment and history. However, eccentricity is often poorly determined or entirely mischaracterized due to poor observational sampling, low signal-to-noise, and/or degeneracies with other planetary signals. Some systems previously thought to contain a single, moderate-eccentricity planet have been shown, after further monitoring, to host two planets on nearly circular orbits. We investigate published apparent single-planet systems to see if the available data can be better fit by two lower-eccentricity planets. We identify nine promising candidate systems and perform detailed dynamical tests to confirm the stability of the potential new multiple-planet systems. Finally, we compare the expected orbits of the single- and double-planet scenarios to better inform future observations of these interesting systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Weak-lensing mass calibration of the Atacama Cosmology Telescope equatorial Sunyaev-Zeldovich cluster sample with the Canada-France-Hawaii telescope stripe 82 survey

Mass calibration uncertainty is the largest systematic effect for using clusters of galaxies to constrain cosmological parameters. We present weak lensing mass measurements from the Canada-France-Hawaii Telescope Stripe 82 Survey for galaxy clusters selected through their high signal-to-noise thermal Sunyaev-Zeldovich (tSZ) signal measured with the Atacama Cosmology Telescope (ACT). For a sample of 9 ACT clusters with a tSZ signal-to-noise greater than five the average weak lensing mass is (4.8±0.8) ×10{sup 14} M{sub ⊙}, consistent with the tSZ mass estimate of (4.70±1.0) ×10{sup 14} M{sub ⊙} which assumes a universal pressure profile for the cluster gas. Our results are consistent with previous weak-lensing measurements of tSZ-detected clusters from the Planck satellite. When comparing our results, we estimate the Eddington bias correction for the sample intersection of Planck and weak-lensing clusters which was previously excluded.

79 ASTRONOMY AND ASTROPHYSICS↗

A 7 µm mini-beam improves diffraction data from small or imperfect crystals of macromolecules

An X-ray mini-beam of 8 × 6 µm cross-section was used to collect diffraction data from protein microcrystals with volumes as small as 150–300 µm{sup 3}. The benefits of the mini-beam for experiments with small crystals and with large inhomogeneous crystals are investigated. A simple apparatus for achieving beam sizes in the range 5-10 µm on a synchrotron beamline was implemented in combination with a small 125 × 25 µm focus. The resulting beam had sufficient flux for crystallographic data collection from samples smaller than 10 × 10 × 10 µm. Sample data were collected representing three different scenarios: (i) a complete 2.0 Å data set from a single strongly diffracting microcrystal, (ii) a complete and redundant 1.94 Å data set obtained by merging data from six microcrystals and (iii) a complete 2.24 Å data set from a needle-shaped crystal with less than 12 × 10 µm cross-section and average diffracting power. The resulting data were of high quality, leading to well refined structures with good electron-density maps. The signal-to-noise ratios for data collected from small crystals with the mini-beam were significantly higher than for equivalent data collected from the same crystal with a 125 × 25 µm beam. Relative to this large beam, use of the mini-beam also resulted in lower refined crystal mosaicities. The mini-beam proved to be advantageous for inhomogeneous large crystals, where better ordered regions could be selected by the smaller beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A CCD integrated circuit for transient recorders

A 50 MHz CCD integrated circuit is described that was developed for use in transient analog signal recorders to sample and time expand transient signals. The integrated circuit achieves an effective 200 MHz sample rate by using four 32 stage peristaltic CCDs to sample the transient signal four times each clock period. Dual frequency, 4 phi clocking is used to sample and time expand the sampled data. The output signals of the four CCDs are multiplexed on chip into a single low frequency output data line. When operated with 50 MHz/165 KHz 4 phi clocks, this circuit has a 200 MHz sample rate, a record length of 640 nanoseconds, a time expansion factor of 303, and overall signal to noise ratio of 40:1. The signal to noise ratio is limited by fixed pattern noise of the four CCDs.

Balch, J. W.↗

Weak-Lensing Mass Calibration of the Atacama Cosmology Telescope Equatorial Sunyaev-Zeldovich Cluster Sample with the Canada-France-Hawaii Telescope Stripe 82 Survey

Mass calibration uncertainty is the largest systematic effect for using clustersof galaxies to constrain cosmological parameters. We present weak lensing mass measurements from the Canada-France-Hawaii Telescope Stripe 82 Survey for galaxy clusters selected through their high signal-to-noise thermal Sunyaev-Zeldovich (tSZ) signal measured with the Atacama Cosmology Telescope (ACT). For a sample of 9 ACT clusters with a tSZ signal-to-noise greater than five, the average weak lensing mass is (4.8 plus or minus 0.8) times 10 (sup 14) solar mass, consistent with the tSZ mass estimate of (4.7 plus or minus 1.0) times 10 (sup 14) solar mass, which assumes a universal pressure profile for the cluster gas. Our results are consistent with previous weak-lensing measurements of tSZ-detected clusters from the Planck satellite. When comparing our results, we estimate the Eddington bias correction for the sample intersection of Planck and weak-lensing clusters which was previously excluded.

Battaglia, N.↗

Binary polarization-shift-keyed modulation for interplanetary CubeSat optical communications

Recent developments for laser communication on CubeSats across interplanetary distances will be presented. A binary polarization-shift-keyed modulation scheme using dual gain-switched diode lasers is developed and demonstrated within an end-to-end link testbed to achieve signal acquisition under extremely poor signal-to-noise conditions (-43.5 dB average signal-to-noise power ratio at a 1-MHz symbol rate) to simulate direct-to-Earth links, while simultaneously targeting a limited SWaP footprint (1.5U envelope). Additional system design and constraints for the compact laser transmitter will be discussed.

Kovalik, Joseph M.↗

Laser radar studies: A study of the feasibility of remote measurement of atmospheric density and turbidity by means of rotational Raman scattering of laser light

A remote sensing technique is described which utilizes elastic scattering and rotational Raman scattering of laser light in the atmosphere to obtain soundings of turbidity, transmissivity and density. A scheme is devised whereby, through selective weighting of the rotational Raman lines, the effect of atmospheric temperature structure may be eliminated. The close spectral proximity of the elastic and Raman-scattered signals, combined with the fact that the Raman scattering is quite weak, produces special requirements for the spectroscopic and light-gathering components of a rotational Raman laser radar system. These requirements are investigated. A computation of typical signal-to-noise ratios is made. It is shown that daytime signal-to-noise ratios greater than 10 db are to be expected for observation heights of 5 km and below. For nighttime work, 10 db signal-to-noise ratios are achievable to altitudes as high as 15 km.

Reiss, N.↗

Understanding and quantifying the systematic effects of clutter within a radiation detection scene

Because of low signal-to-noise ratios, the main difficultly in real-world detection scenarios is distinguishing between benign sources and potentially-threatening radioactive materials. The variability in observed signal during a radiation detection search operation can be contributed to the stochastic nature of the underlying physics and the systematic errors inherent to the detection systems employed. This variability is compounded for dynamic detection scenarios, where objects, referred to as clutter, traverse through the primary detection scene, introducing potential suppressions in the observed signal due to the attenuation of background radiation. This study examines the impact that clutter, namely automobiles such as small utility vehicles, sedans, and trucks, produces on the observed signal in a 2 in. × 4 in. × 16 in. NaI(Tl) detector. The clutter is identified and tracked in the detection scene using a time-synced video camera and a 2-D light distance and ranging contextual sensors. Two experiments were performed on the Oak Ridge National Laboratory reservation: one using a distributed source within the scene to understand the systematics of detecting and analyzing the clutter, and the second experiment mimicking an urban environment with large buildings positioned on either side of a roadway. The experiments exhibited unique results in the amount of signal suppression and variability of the cluttered signal, both demonstrating an observable suppression from the clutter-free background. These results reveal a new potential category of signal noise intrinsic to real-world detection scenarios that should be considered when establishing detection thresholds based on expected values.

Stewart, Ian R.↗

Improved S/N meter

Signal-to-noise ratios /S/N/ meter containing a variable-frequency notch filter measures noise plus interference in the presence of carrier or modulation signals. A noise source and calibration signal source are included in the instrument for calibration purposes.

Windett, C. B.↗

On the precision of automated activation time estimation

We examined how the assignment of local activation times in epicardial and endocardial electrograms is affected by sampling rate, ambient signal-to-noise ratio, and sinx/x waveform interpolation. Algorithms used for the estimation of fiducial point locations included dV/dtmax, and a matched filter detection algorithm. Test signals included epicardial and endocardial electrograms overlying both normal and infarcted regions of dog myocardium. Signal-to-noise levels were adjusted by combining known data sets with white noise "colored" to match the spectral characteristics of experimentally recorded noise. For typical signal-to-noise ratios and sampling rates, the template-matching algorithm provided the greatest precision in reproducibly estimating fiducial point location, and sinx/x interpolation allowed for an additional significant improvement. With few restrictions, combining these two techniques may allow for use of digitization rates below the Nyquist rate without significant loss of precision.

NASA Discipline Cardiopulmonary↗

Infrared Avionics Signal Distribution using Wavelength Division Multiplexing

Pilots in the cockpits of aircrafts currently communicate with ground stations using Radio Frequency (RF) signals. Antennas mounted outside the aircraft receive and transmit RF signals from and to the ground stations. The RF signals received at the antennas are sent to the cockpit using coaxial cables. As the number of antennas needed to provide more than one frequency band in aircrafts increases, RF distribution media (such as coaxial cable) adds to the complexity and weight of the cockpit wiring. Concomitantly, the safety and signal to noise ratio also decreases due to the use of RF signals. The University of Oklahoma is collaborating with the National Aeronautics and Space Administration to develop optical fiber based schemes to replace the coaxial cable used for RF signal distribution within an aircraft. The project aims at exploiting emerging Wavelength Division Multiplexing (WDM) techniques to reduce the weight of cabling, and increase the signal to noise ratio and reliability. This will be achieved by wavelength division multiplexing the signals from the various antennas and then demultiplexing the signals to recover the original signals at the cockpit. This paper will show that (i) RF signals can not only be wavelength multiplexed at the end of a fiber, but additional signals can be inserted into the middle of the fiber using WDM technology, and (ii) the signals can also be successfully extracted by tapping into the middle of the fiber. We are currently extending our previous laboratory prototype (which could multiplex signals only at the end of the fiber) to include additional multiplexing and demultiplexing of RF signals from the middle of the optical backbone with a view to validating the proof of concept, and carrying out measurements to determine the effectiveness of Wavelength Division Multiplexing for avionics applications. A test bed to perform measurements of several relevant parameters for various modulation schemes and frequencies (such as VHF, UHF, and L-Band) has been implemented. In particular, results of transmitter and receiver noise, bit-error-rate (BER), effect of cross talk on the quality of the multiplexed signals, and Signal to Noise ratio and Carrier to Noise ratio, obtained using the aforementioned test bed, will be presented.

Atiquzzaman, Mohammed↗

A 128-Tap Highly Tunable CMOS IF Finite Impulse Response Filter for Pulsed Radar Applications

A configurable-bandwidth (BW) filter is presented in this paper for pulsed radar applications. Also, to eliminate dispersion effects in the received waveform, a finite impulse response (FIR) topology is proposed, which has a measured standard deviation of an in-band group delay of 11 ns that is primarily dominated by the inherent, fully predictable delay introduced by the sample-and-hold. The filter operates at an IF of 20 MHz, and is tunable in BW from 1.5 to 15 MHz, which makes it optimal to be used with varying pulse widths in the radar. Employing a total of 128 taps, the FIR filter provides greater than 50-dB sharp attenuation in the stopband in order to minimize all out-of-band noise in the low signal-to-noise received radar signal. Fabricated in a 0.18-μm silicon on insulator CMOS process, the proposed filter consumes approximately 3.5 mW/tap with a 1.8-V supply. Finally, a 20-MHz two-tone measurement with 200-kHz tone separation shows IIP3 greater than 8.5 dBm.

42 ENGINEERING↗

DETECTION OF POTENTIAL TRANSIT SIGNALS IN THE FIRST 12 QUARTERS OF KEPLER MISSION DATA

We present the results of a search for potential transit signals in the first three years of photometry data acquired by the Kepler mission. The targets of the search include 112,321 targets that were observed over the full interval and an additional 79,992 targets that were observed for a subset of the full interval. From this set of targets we find a total of 11,087 targets that contain at least one signal that meets the Kepler detection criteria: periodicity of the signal, an acceptable signal-to-noise ratio, and three tests that reject false positives. Each target containing at least one detected signal is then searched repeatedly for additional signals, which represent multi-planet systems of transiting planets. When targets with multiple detections are considered, a total of 18,406 potential transiting planet signals are found in the Kepler mission data set. The detected signals are dominated by events with relatively low signal-to-noise ratios and by events with relatively short periods. The distribution of estimated transit depths appears to peak in the range between 20 and 30 parts per million, with a few detections down to fewer than 10 parts per million. The detections exhibit signal-to-noise ratios from 7.1{sigma}, which is the lower cutoff for detections, to over 10,000{sigma}, and periods ranging from 0.5 days, which is the shortest period searched, to 525 days, which is the upper limit of achievable periods given the length of the data set and the requirement that all detections include at least three transits. The detected signals are compared to a set of known transit events in the Kepler field of view, many of which were identified by alternative methods; the comparison shows that the current search recovery rate for targets with known transit events is 98.3%.

79 ASTRONOMY AND ASTROPHYSICS↗