Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

A Radiation Badge Survey for Family Members Living With Patients Treated With a {sup 103}Pd Permanent Breast Seed Implant

Purpose: Sixty-seven patients with early-stage breast cancer were treated in a Phase I/II clinical trial using a {sup 103}Pd permanent breast seed implant as adjuvant radiotherapy after breast-conserving surgery. We report the dose received by family members living with these patients and compare measured doses with theoretical worst-case scenario estimates. Methods and Materials: Exposure-rate measurements were taken at 1 m from the patient by using a calibrated low-energy survey meter. Landauer (Landauer Inc., Glenwood, IL) Luxel badges, with sensitivity of 0.01 mSv, were given to family members to wear after the implantation. Badge readings for 33 spouses and 28 other family members were used to estimate effective doses, and these were compared with theory. Results: Average preimplantation planning target volume from computed tomography was 50.3 ml (range, 18.0-96.7 ml), and average preimplantation distance between the skin and the most anterior planning target volume margin was 0.57 cm. The average maximum exposure rate was measured to be 2.4 {+-} 1.1 mR/h, and average measured dose to a spouse was 0.99 {+-} 1.0 mSv. The calculated exposure rates and spousal doses using preimplantation computed tomography scan data overestimated those measured. Average measured family member dose (excluding spouses) was 0.20 {+-} 0.58 mSv. Conclusions: Based on measured and calculated spousal doses, a permanent breast seed implant using {sup 103}Pd is safe for the public. However, it is recommended that extra precautions in the way of a breast patch be used when patients with an implant will be in the vicinity of toddlers or pregnant women.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poor Predictive Value of Intraoperative Real-Time Dosimetry for Prostate Seed Brachytherapy

Purpose: To identify dosimetric parameters predictive of a good prostate seed I{sup 125} quality implant. We analyzed preimplant and postimplant realtime dosimetry in patients treated with intraoperative (IO) inverse planning. Methods and Materials: We analyzed 127 consecutively treated patients with primarily low-risk prostate carcinoma who underwent prostate permanent seed I{sup 125} brachytherapy using an IO planning approach. The implant was done using the three-dimensional transrectal ultrasound (PRE-TRUS)-guided IO interactive inverse preplanning system. The TRUS was repeated in the operating room after the implant procedure was complete (POST-TRUS). The prostate was recontoured and postimplant dosimetry was calculated. Each patient underwent computed tomography scan on Day 28 (CT-D28) to evaluate implant quality. Area under the receiver operating characteristic curves (AUROC) was evaluated for models predictive of a V100 of {>=}90% and a D90 of {>=}140 Gy on the basis of CT-D28 values. Results: On CT-D28, 72.4% of patients had a V100 of {>=}90% and 74.8% had a D90 of {>=}140 Gy. AUROC for a V100 of {>=}90% was 0.665 (p = 0.004) on PRE-TRUS and 0.619 (p = 0.039) on POST-TRUS. AUROC for D90 of {>=}140 Gy was 0.602 (p = 0.086) on PRE-TRUS and 0.614 (p = 0.054) on POST-TRUS. Using PRE-TRUS V100 cutoff of >97% gives sensitivity of 88% and a false-positive rate of 63%. A POST-TRUS D90 cutoff of >170 Gy resulted in a sensitivity of 62% and a false-positive rate of 34%. Conclusions: Because of unacceptably high false-positive rates, IO preimplant and postimplant TRUS-based dosimetry are not accurate tools to predict for postimplant computed tomography-based dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tolerance and Acceptance Results of a Palladium-103 Permanent Breast Seed Implant Phase I/II Study

Purpose: To test, in a prospective Phase I/II trial, a partial breast irradiation technique using a {sup 103}Pd permanent breast seed implant (PBSI) realized in a single 1-h procedure under sedation and local freezing. Methods and Materials: Eligible patients had infiltrating ductal carcinoma {<=}3 cm in diameter, surgical margin {>=}2 mm, no extensive intraductal component, no lymphovascular invasion, and negative lymph nodes. Patients received a permanent seed implant, and a minimal peripheral dose of 90 Gy was prescribed to the clinical target volume, with a margin of 1.5 cm. Results: From May 2004 to April 2007, 67 patients received the PBSI treatment. The procedure was well tolerated, with 17% of patients having significant pain after the procedure. Only 1 patient (1.5%) had an acute skin reaction (Grade 3 according to the National Cancer Institute Common Toxicity Criteria). The rates of acute moist desquamation, erythema, and indurations were 10.4%, 42%, and 27%, respectively. At 1 year the rate of Grade 1 telangiectasia was 14%. The rate of skin reaction decreased from 65% to 28% when skin received less than the 85% isodose. According to a Radiation Therapy Oncology Group questionnaire, 80-90% of patients were very satisfied with their treatment, and the remainder were satisfied. One patient (1.5%) developed an abscess, which resolved after the use of antibiotics. There was no recurrence after a median follow-up of 32 months (range, 11-49 months). Conclusions: The feasibility, safety, and tolerability of PBSI compares favorably with that of external beam and other partial breast irradiation techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation Between Pre- and Postimplant Dosimetry for Iodine-125 Seed Implants for Localized Prostate Cancer

Purpose: In order to evaluate implant quality for permanent prostate brachytherapy in patients with localized prostate cancer, American Brachytherapy Society and ESTRO guidelines recommend that postimplant dosimetry should be performed. To understand more about the relationship between pre- and postimplant dosimetry, a comparison was made of patients who received iodine-125 ({sup 125}I) brachytherapy between March 1995 and the end of 2004, using a preplan technique. Methods and Materials: CT postimplant dosimetry was available for 707 patients. Detailed dose volume analysis was performed using both preimplant ultrasound and postimplant CT data sets for a subgroup of 445 patients. The following parameters were compared: prostate volume covered by 100% of the prescription dose (Vp100), Vp150, and Vp200 and dose to 90% (D90) of the prostate. In addition, volume implanted (Vi) parameters were used to compare pre- and postimplant dosimetry. Vi parameters describe dose levels inside the patient, based on number of seeds, seed activity, and their spatial distribution relative to each other, without reference to the actual prostate volume or position. Results: The mean {+-} standard deviation values of preimplant (34.7 {+-} 8.9 cm{sup 3}) and postimplant (36.7 {+-} 9.4 cm{sup 3}) prostate volumes were similar. The mean ({+-}standard deviation) planned D90 was 183.4 ({+-}12.1) Gy while the D90 that was achieved was 145.5 ({+-}20.4) Gy. Over the study period, there was a steady increase of the average D90. Postimplant CT D90 and Vp100 values correlated significantly (R = 0.84; p < 0.001). The Vi and Vp parameters all showed a strong correlation. Conclusions: In this study, we showed that there is a strong correlation between transrectal ultrasound-based preimplant and CT-based postimplant dosimetry. The excellent correlation between prostate D90 and V100 values demonstrates they are both equally valid quality indices. Vi parameters are an additional measure that can be used to assess the quality of the implant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seed Implant Retention Score Predicts the Risk of Prolonged Urinary Retention After Prostate Brachytherapy

Purpose: To risk-stratify patients for urinary retention after prostate brachytherapy according to a novel seed implant retention score (SIRS). Patients and Methods: A total of 835 patients underwent transperineal prostate seed implant from March 1993 to January 2007; 197 patients had {sup 125}I and 638 patients had {sup 103}Pd brachytherapy. Four hundred ninety-four patients had supplemental external-beam radiation. The final downsized prostate volume was used for the 424 patients who had neoadjuvant hormone therapy. Retention was defined as reinsertion of a Foley catheter after the implant. Results: Retention developed in 7.4% of patients, with an average duration of 6.7 weeks. On univariate analysis, implant without supplemental external-beam radiation (10% vs. 5.6%; p = 0.02), neoadjuvant hormone therapy (9.4% vs. 5.4%; p = 0.02), baseline alpha-blocker use (12.5% vs. 6.3%; p = 0.008), and increased prostate volume (13.4% vs. 6.9% vs. 2.9%, >45 cm{sup 3}, 25-45 cm{sup 3}, <25 cm{sup 3}; p = 0.0008) were significantly correlated with increased rates of retention. On multivariate analysis, implant without supplemental external-beam radiation, neoadjuvant hormone therapy, baseline alpha-blocker use, and increased prostate volume were correlated with retention. A novel SIRS was modeled as the combined score of these factors, ranging from 0 to 5. There was a significant correlation between the SIRS and retention (p < 0.0001). The rates of retention were 0, 4%, 5.6%, 9%, 20.9%, and 36.4% for SIRS of 0 to 5, respectively. Conclusions: The SIRS may identify patients who are at high risk for prolonged retention after prostate brachytherapy. A prospective validation study of the SIRS is planned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Urethra-Sparing, Intraoperative, Real-Time Planned, Permanent-Seed Prostate Brachytherapy: Toxicity Analysis

Purpose: To report the toxicity outcome in patients with localized prostate cancer undergoing {sup 125}I permanent-seed brachytherapy (BT) according to a urethra-sparing, intraoperative (IO), real-time planned conformal technique. Methods and Materials: Data were analyzed on 250 patients treated consecutively for low- or intermediate-risk prostate cancer between 2005 and 2009. The planned goal was urethral V{sub 150} = 0. Acute and late genitourinary (GU), gastrointestinal (GI), and erectile toxicities were scored with the International Prostate Symptom Score (IPSS) questionnaire and Common Terminology Criteria for Adverse Events (version 3.0). Median follow-up time for patients with at least 2 years of follow-up (n = 130) was 34.4 months (range, 24-56.9 months). Results: Mean IO urethra V{sub 150} was 0.018% {+-} 0.08%. Mean prostate D{sub 90} and V{sub 100} on day-30 computed tomography scan were 158.0 {+-} 27.0 Gy and 92.1% {+-} 7.2%, respectively. Mean IPSS peak was 9.5 {+-} 6.3 1 month after BT (mean difference from baseline IPSS, 5.3). No acute GI toxicity was observed in 86.8% of patients. The 3-year probability of Grade {>=}2 late GU toxicity-free survival was 77.4% {+-} 4.0%, with Grade 3 late GU toxicity encountered in only 3 patients. Three-year Grade 1 late GI toxicity-free survival was 86.1% {+-} 3.2%. No patient presented Grade {>=}2 late GI toxicity. Of patients with normal sexual status at baseline, 20.7% manifested Grade {>=}2 erectile dysfunction after BT. On multivariate analysis, elevated baseline IPSS (p = 0.016) and high-activity sources (median 0.61 mCi) (p = 0.033) predicted increased Grade {>=}2 late GU toxicity. Conclusions: Urethra-sparing IO BT results in low acute and late GU toxicity compared with the literature. High seed activity and elevated IPSS at baseline increased long-term GU toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conventional Versus Automated Implantation of Loose Seeds in Prostate Brachytherapy: Analysis of Dosimetric and Clinical Results

Purpose: To review the clinical outcome of I-125 permanent prostate brachytherapy (PPB) for low-risk and intermediate-risk prostate cancer and to compare 2 techniques of loose-seed implantation. Methods and Materials: 574 consecutive patients underwent I-125 PPB for low-risk and intermediate-risk prostate cancer between 2000 and 2008. Two successive techniques were used: conventional implantation from 2000 to 2004 and automated implantation (Nucletron, FIRST system) from 2004 to 2008. Dosimetric and biochemical recurrence-free (bNED) survival results were reported and compared for the 2 techniques. Univariate and multivariate analysis researched independent predictors for bNED survival. Results: 419 (73%) and 155 (27%) patients with low-risk and intermediate-risk disease, respectively, were treated (median follow-up time, 69.3 months). The 60-month bNED survival rates were 95.2% and 85.7%, respectively, for patients with low-risk and intermediate-risk disease (P=.04). In univariate analysis, patients treated with automated implantation had worse bNED survival rates than did those treated with conventional implantation (P<.0001). By day 30, patients treated with automated implantation showed lower values of dose delivered to 90% of prostate volume (D90) and volume of prostate receiving 100% of prescribed dose (V100). In multivariate analysis, implantation technique, Gleason score, and V100 on day 30 were independent predictors of recurrence-free status. Grade 3 urethritis and urinary incontinence were observed in 2.6% and 1.6% of the cohort, respectively, with no significant differences between the 2 techniques. No grade 3 proctitis was observed. Conclusion: Satisfactory 60-month bNED survival rates (93.1%) and acceptable toxicity (grade 3 urethritis <3%) were achieved by loose-seed implantation. Automated implantation was associated with worse dosimetric and bNED survival outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Significance of Accounting for Tissue Heterogeneity in Permanent Breast Seed Implant Brachytherapy Planning

Purpose: The inhomogeneity correction factor (ICF) method provides heterogeneity correction for the fast calculation TG43 formalism in seed brachytherapy. This study compared ICF-corrected plans to their standard TG43 counterparts, looking at their capacity to assess inadequate coverage and/or risk of any skin toxicities for patients who received permanent breast seed implant (PBSI). Methods and Materials: Two-month postimplant computed tomography scans and plans of 140 PBSI patients were used to calculate dose distributions by using the TG43 and the ICF methods. Multiple dose-volume histogram (DVH) parameters of clinical target volume (CTV) and skin were extracted and compared for both ICF and TG43 dose distributions. Short-term (desquamation and erythema) and long-term (telangiectasia) skin toxicity data were available on 125 and 110 of the patients, respectively, at the time of the study. The predictive value of each DVH parameter of skin was evaluated using the area under the receiver operating characteristic (ROC) curve for each toxicity endpoint. Results: Dose-volume histogram parameters of CTV, calculated using the ICF method, showed an overall decrease compared to TG43, whereas those of skin showed an increase, confirming previously reported findings of the impact of heterogeneity with low-energy sources. The ICF methodology enabled us to distinguish patients for whom the CTV V{sub 100} and V{sub 90} are up to 19% lower compared to TG43, which could present a risk of recurrence not detected when heterogeneity are not accounted for. The ICF method also led to an increase in the prediction of desquamation, erythema, and telangiectasia for 91% of skin DVH parameters studied. Conclusions: The ICF methodology has the advantage of distinguishing any inadequate dose coverage of CTV due to breast heterogeneity, which can be missed by TG43. Use of ICF correction also led to an increase in prediction accuracy of skin toxicities in most cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of camelina mid-oleic acid seed oil by identification and stacking of fatty acid biosynthetic mutants

Modifying oilseeds to obtain a desired fatty acid composition is often necessary to enable use as feedstocks for specific applications such as food processing, biofuels, or biolubricants. A mutant population of camelina (Camelina sativa), an emerging specialty oilseed crop, was screened by high-throughput gas chromatography for lines with altered seed oil fatty acid composition. By leveraging knowledge of fatty acid synthesis in Arabidopsis thaliana, mutations in orthologs of FATTY ACID ELONGASE1 (FAE1), FATTY ACID DESATURASE2 (FAD2), FATTY ACID DESATURASE3 (FAD3), and β-KETO-ACYL-ACP SYNTHASE II (KASII; FAB1) were identified. The mutations altered conserved amino acid residues in the encoded proteins. The ability of the mutations in FAE1, FAD2 and FAD3 to affect enzyme function was demonstrated by comparing in vivo activities of wild-type and mutant alleles in yeast. In addition, expression of wild-type cDNA in camelina complemented fatty acid phenotypes of these mutants. As camelina has a hexaploid genome, the effect of a mutation in one of the three homeologs for each gene resulted in no or less severe growth phenotypes compared to similar mutations in Arabidopsis. Mid-oleic oils with nearly 40 % oleic acid and reduced very long-chain (≤C20) fatty acid content were obtained by crossing to obtain a fae1c/fad2a/fae1a/fad3a quadruple mutant. Little effect on total seed oil content was observed in the stacked mutant line. Finally, the resulting mid-oleic acid oil had improved oxidative stability due to reductions in polyunsaturated fatty acid content, increasing its utility for biofuels and other applications.

09 BIOMASS FUELS↗

Distributed approximate minimal Steiner trees with millions of seed vertices on billion-edge graphs

In this report, we present a parallel 2-approximation Steiner minimal tree algorithm and its MPI-based distributed implementation. In place of expensive distance computations between all pairs of seed vertices, the solution we employ exploits a cheaper Voronoi cell computation. Our design leverages asynchronous processing and message prioritization to accelerate convergence of distance computations, and harnesses vertex and edge centric processing to offer fast time-to-solution. We demonstrate scalability and performance using real-world graphs with up to 128 billion edges and 512 compute nodes, and show the ability to find Steiner trees with up to one million seed vertices. Using 12 data instances, we present comparison with the state-of-the-art exact solver, SCIP-Jack, and two sequential 2-approximate algorithms. We empirically show that, on average, the total distance of the Steiner tree identified by our solution is 1.1290 times greater than the Steiner minimal tree – well within the theoretical approximation bound of 2.

97 MATHEMATICS AND COMPUTING↗

Seed-mediated synthesis, properties and application of {gamma}-Fe{sub 2}O{sub 3}-CdSe magnetic quantum dots

Seed-mediated growth of fluorescent CdSe quantum dots (QDs) around {gamma}-Fe{sub 2}O{sub 3} magnetic cores was performed at high temperature (300 deg. C) in the presence of organic surfactants. Bi-functional magnetic quantum dots (MQDs) with tunable emission properties were successfully prepared. The as-synthesized MQDs were characterized by high-resolution transmission electron microscopy (HRTEM) and dynamic light scattering (DLS), which confirmed the assembly of heterodimers. When a longer growth period was employed, a homogeneous dispersion of QDs around a magnetic nanoparticle was obtained. The magnetic properties of these nanocomposites were examined. The MQDs were superparamagnetic with a saturation magnetization of 0.40 emu/g and a coercivity of 138 Oe at 5 K. To demonstrate their potential application in bio-labeling, these MQDs were coated with a thin silica shell, and functionalized with a polyethylene glycol (PEG) derivative. The functionalized MQDs were effectively used for the labeling of live cell membranes of 4T1 mouse breast cancer cells and HepG2 human liver cancer cells. - Graphical abstract: (a) HRTEM image of oleic acid capped MPs. The size of MPs ranges from 8 to 10 nm. (b) XRD pattern of {gamma}-Fe{sub 2}O{sub 3} MPs. Highlights: > The fabrication of MQDs through a seed-mediated approach has been demonstrated. > The formation and assembly of these bi-functional nanocomposites have been elucidated. > The MQDs exhibit superparamagnetism and tunable emissions characteristic of the components. > MQDs with thin silica coating were successfully employed in the labeling of cancer cell membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Top-seeded solution crystal growth of noncentrosymmetric and polar Zn{sub 2}TeMoO{sub 7} (ZTM)

A top-seeded solution growth (TSSG) method was used to grow large, centimeter size, crystals of Zn{sub 2}TeMoO{sub 7} (ZTM) – a noncentrosymmetric and polar material. A TeO{sub 2}–MoO{sub 3} mixture in combination with the parent compound was used as a flux. The morphologies of the crystals can be controlled by different rotation speeds. Optical spectra indicate that ZTM is transparent up to 5.25 µm with a UV absorption edge of 300 nm. In addition, the refractive index along the optical x, y, and z axes was measured at different wavelengths. - Highlights: • Zn{sub 2}TeMo{sub 2}O{sub 7} crystals were grown by top-seeded solution growth (TSSG) method. • The morphology of the single crystals is controllable by changing rotation speed. • Optical transmission spectra indicate Zn{sub 2}TeMo{sub 2}O{sub 7} has a broad transmission range. • Refractive index along optical axes was measured at different wavelengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functional chitosan-based grapefruit seed extract composite films for applications in food packaging technology

Highlights: • Chitosan-based grapefruit seed extract (GFSE) films were solution casted. • GFSE was uniformly dispersed within all chitosan film matrices. • All chitosan-based composite films showed remarkable transparency. • Increasing amounts of GFSE incorporated increased the elongation at break of films. • Chitosan-based GFSE composite films inhibited the proliferation of fungal growth. - Abstract: Chitosan-based composite films with different amounts of grapefruit seed extract (GFSE) (0.5, 1.0 and 1.5% v/v) were fabricated via solution casting technique. Experimental results showed that GFSE was uniformly dispersed within all chitosan film matrices. The presence of GFSE made the films more amorphous and tensile strength decreased, while elongation at break values increased as GFSE content increased. Results from the measurement of light transmission revealed that increasing amounts of GFSE (from 0.5 to 1.5% v/v) did not affect transparency of the films. Furthermore, packaging of bread samples with chitosan-based GFSE composite films inhibited the proliferation of fungal growth as compared to control samples. Hence, chitosan-based GFSE composite films have the potential to be a useful material in the area of food technology.

36 MATERIALS SCIENCE↗

Alignment nature of ZnO nanowires grown on polished and nanoscale etched lithium niobate surface through self-seeding thermal evaporation method

Highlights: • ZnO nanowires were grown directly on LiNbO{sub 3} surface for the first time by thermal evaporation. • Self-alignment of the nanowires due to step bunching of LiNbO{sub 3} surface is observed. • Increased roughness in surface defects promoted well-aligned growth of nanowires. • Well-aligned growth was then replicated in 50 nm deep trenches on the surface. • Study opens novel pathway for patterned growth of ZnO nanowires on LiNbO{sub 3} surface. - Abstract: High aspect ratio catalyst-free ZnO nanowires were directly synthesized on lithium niobate substrate for the first time through thermal evaporation method without the use of a buffer layer or the conventional pre-deposited ZnO seed layer. As-grown ZnO nanowires exhibited a crisscross aligned growth pattern due to step bunching of the polished lithium niobate surface during the nanowire growth process. On the contrary, scratches on the surface and edges of the substrate produced well-aligned ZnO nanowires in these defect regions due to high surface roughness. Thus, the crisscross aligned nature of high aspect ratio nanowire growth on the lithium niobate surface can be changed to well-aligned growth through controlled etching of the surface, which is further verified through reactive-ion etching of lithium niobate. The investigations and discussion in the present work will provide novel pathway for self-seeded patterned growth of well-aligned ZnO nanowires on lithium niobate based micro devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

61 RADIATION PROTECTION AND DOSIMETRY↗

Grape seed proanthocyanidins reactivate silenced tumor suppressor genes in human skin cancer cells by targeting epigenetic regulators

Grape seed proanthocyanidins (GSPs) have been shown to have anti-skin carcinogenic effects in in vitro and in vivo models. However, the precise epigenetic molecular mechanisms remain unexplored. This study was designed to investigate whether GSPs reactivate silenced tumor suppressor genes following epigenetic modifications in skin cancer cells. For this purpose, A431 and SCC13 human squamous cell carcinoma cell lines were used as in vitro models. The effects of GSPs on DNA methylation, histone modifications and tumor suppressor gene expressions were studied in these cell lines using enzyme activity assays, western blotting, dot-blot analysis and real-time polymerase chain reaction (RT-PCR). We found that treatment of A431 and SCC13 cells with GSPs decreased the levels of: (i) global DNA methylation, (ii) 5-methylcytosine, (iii) DNA methyltransferase (DNMT) activity and (iv) messenger RNA (mRNA) and protein levels of DNMT1, DNMT3a and DNMT3b in these cells. Similar effects were noted when these cancer cells were treated identically with 5-aza-2′-deoxycytidine, an inhibitor of DNA methylation. GSPs decreased histone deacetylase activity, increased levels of acetylated lysines 9 and 14 on histone H3 (H3-Lys 9 and 14) and acetylated lysines 5, 12 and 16 on histone H4, and reduced the levels of methylated H3-Lys 9. Further, GSP treatment resulted in re-expression of the mRNA and proteins of silenced tumor suppressor genes, RASSF1A, p16{sup INK4a} and Cip1/p21. Together, this study provides a new insight into the epigenetic mechanisms of GSPs and may have significant implications for epigenetic therapy in the treatment/prevention of skin cancers in humans. -- Highlights: ►Epigenetic modulations have been shown to have a role in cancer risk. ►Proanthocyanidins decrease the levels of DNA methylation and histone deacetylation. ►Proanthocyanidins inhibit histone deacetylase activity in skin cancer cells. ►Proanthocyanidins reactivate tumor suppressor genes in skin cancer cells. ►Grape seed proanthocyanidins can prevent skin cancer through epigenetic modulation.

60 APPLIED LIFE SCIENCES↗

From Weibel seeds to dynamo beyond pair-plasmas

Bridging the spatiotemporal scales of magnetic seed field generation and subsequent dynamo amplification in the weakly collisional intracluster medium presents an extreme numerical challenge. We perform collisionless turbulence simulations with initially unmagnetised electrons that capture both magnetic seed generation via the electron Weibel instability and the ensuing dynamo amplification. Going beyond existing pair-plasma studies, we use an ion-to-electron mass ratio of 100 for which we find electron and ion dynamics are sufficiently decoupled. These simulations are enabled by the 10-moment collisionless fluid solver of Gkeyll, which evolves the full pressure tensor for all species. The electron heat-flux closure regulates pressure isotropisation and effectively sets the magnetic Reynolds number. We investigate how the strength of the closure influences the transition between a regime reminiscent of previous kinetic pair-plasma simulations and a regime exhibiting dynamo behaviour qualitatively similar to magnetohydrodynamics.

astrophysical plasmas↗

Tunable Growth of Layered Double Hydroxide Nanosheets through Hydrothermal Conversion of Atomic Layer Deposition Seed Layers

To enable the design and manufacturing of hierarchical nanomaterial architectures, there is a need for synthesis and processing methods that can enable tunable geometric control at the nanoscale while maintaining conformality on complex 3-D templates. Here, in this study, we explore the programmable control of vertically oriented Zn-Al layered double hydroxide (LDH) nanosheet arrays using atomic layer deposition (ALD) to deposit a seed layer of Al 2 O 3 , which is subsequently consumed and converted into the LDH phase under hydrothermal growth conditions. We demonstrate tunable control over the spacing and length of the nanosheets by varying the thickness of the initial ALD seed layer with subnanometer precision. This can be viewed as a nanoscale titration reaction, where Al acts as the limiting reagent during the hydrothermal synthesis of the nanosheets. Elemental mapping demonstrates the dynamic evolution of the resulting morphology, which is driven by surface diffusion and nucleation processes. The conformal nature of ALD allows for hierarchical growth of nanosheets on the surface of a variety of nonplanar substrate geometries, including microposts, paper fibers, and porous ceramic supports. This illustrates the power of ALD to enable bottom-up growth of 3-D nanoarchitectures with tunable geometries by controlling nucleation and growth in subsequent solution reactions.

36 MATERIALS SCIENCE↗