GPU Based General-Purpose Parallel computing to Solve Nuclear Reactor In-Core fuel Management Design and Operation Problem

In-core fuel management study is a crucial activity in nuclear power plant design and operation. Its common problem is to find an optimum arrangement of fuel assemblies inside the reactor core. Main objective for this activity is to reduce the cost of generating electricity, which can be done by altering several physical properties of the nuclear reactor without violating any of the constraints imposed by operational and safety considerations. This research try to address the problem of nuclear fuel arrangement problem, which is, leads to the multi-objective optimization problem. However, the calculation of the reactor core physical properties itself is a heavy computation, which became obstacle in solving the optimization problem by using genetic algorithm optimization.This research tends to address that problem by using the emerging General Purpose Computation on Graphics Processing Units (GPGPU) techniques implemented by C language for CUDA (Compute Unified Device Architecture) parallel programming. By using this parallel programming technique, we develop parallelized nuclear reactor fitness calculation, which is involving numerical finite difference computation. This paper describes current prototype of the parallel algorithm code we have developed on CUDA, that performs one hundreds finite difference calculation for nuclear reactor fitness evaluation in parallel by using GPU G9 Hardware Series developed by NVIDIA.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Digital risk analysis in nuclear engineering projects: Designing for safety, performance, reliability, and security

Cyber-informed engineering and security-by-design frameworks are important in promoting the need to identify cybersecurity concerns early in the systems engineering lifecycle so risks from adversarial cyber-attacks can be eliminated or reduced through engineering design practices. In addition to adversarial risk, risk in operational technology systems also includes non-adversarial and unintentional risk from other factors such as human performance errors, environmental conditions, design flaws, and device degradation or failure. This paper introduces a new concept for characterizing digital risk, both adversarial and non-adversarial, and provides the basis for initial research into a novel digital risk analysis approach focused on incorporating attack difficulty into a multi-attribute analysis technique using robust decision-making. This digital risk characterization is also used to frame a discussion on the challenges of competing objectives and competing stakeholder requirements in an integrated energy system project that incorporates a small modular reactor and industrial facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Results of the Protected Superficial Femoral Artery Trial Using the FilterWire EZ System

The purpose of this study was to evaluate the safety and efficacy of debris-capture for distal protection using the FilterWire EZ Embolic Protection System (Boston Scientific, Mountain View, CA) with the additional aim to further define the incidence of distal embolization during superficial femoral artery (SFA) interventions. A prospective, single-centre registry was designed to evaluate the performance of the FilterWire EZ in capturing debris during standard SFA percutaneous intervention. The PRO-RATA study included 30 patients suitable for PTA (Fontaine IIb to III or Rutherford I to II classification). The primary end points were occurrence of distal embolization or decreased runoff, improvement in ankle-brachial index ankle-brachial index (ABI) after the procedure, and number of filters containing emboli. Secondary end points included major adverse events (i.e., procedure- or device-related death and/or clinical target lesion revascularisation), device delivery, deployment success, and incidence of embolic recovery (patients with device success exhibiting embolic protection in the filter). Procedural success was determined as {<=}30% residual stenosis with no worsening of distal runoff as determined on angiography. A total of 29 patients (age 66.2 {+-} 12 years; total no. of limbs = 30; total no. of lesions = 30) suitable for PTA were enrolled in the study between February 2007 and March 2008. There were 26 patients with claudication (Fontaine IIB) and 3 patients with stage IV peripheral vascular disease. In one patient, lesions in both legs were treated. No procedural or device-related complications occured. The average degree of stenosis was 86 {+-} 7%. Stenosis length ranged from 8 to 88 mm. The average degree of residual stenosis was 10 {+-} 10%. ABI improved from 0.56 {+-} 0.16 to 0.92 {+-} 0.19 (P < 0.05). No restenosis or dissection was seen at 1-month ultrasound follow-up. Macroscopic debris was found in 27 of 30 filters of all distal protection devices used in all 29 patients. Debris particle size ranged from 90 to 2000 {mu}m (1200 {+-} 640). Histological debris analysis showed platelets, erythrocytes, inflammatory cells, extracellular matrix, and cholesterol as being the major components of emboli. Additional immunochemistry showed no correlation between lesion morphology and debris components. The FilterWire EZ is easy and safe to handle. The system caused no complications. In all cases, macroscopic debris was captured. Using a distal protection device during femoropopliteal interventions has the potential to prevent migration of debris, which may be important for high-risk patients with limited distal runoff.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kinetic equilibrium reconstruction and the impact on stability analysis of KSTAR plasmas

High fidelity kinetic plasma equilibrium reconstructions are an essential requirement for accurate stability and disruption prediction analyses to support continuous operation of high beta tokamak plasmas. The present kinetic equilibrium reconstructions of plasmas in the KSTAR device include plasma density and temperature profiles from Thomson scattering and ion temperature from charge exchange spectroscopy diagnostics, and allowance for fast particle pressure. In addition, up to 25 channels of motional Stark effect diagnostic data are used to constrain the magnetic field pitch angle profile in the plasma to produce a reliable computation of the safety factor, q, profile. In this work, H-mode plasmas exhibit clear pedestal characteristics in the reconstructed pressure profile compared to internal transport barrier or L-mode plasmas. The plasma configuration and vertical position of inner strike points are validated by CCD and infrared camera images. Ideal and resistive magnetohydrodynamic (MHD) stability analyses using the DCON and resistive DCON codes utilize these kinetic equilibrium reconstructions to compare to experimental plasma stability. Equilibria with sufficiently low convergence error can provide reliable computation of ideal and resistive MHD stability analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

International Benchmarking: A Global Perspective of Workplace Drug and Alcohol Testing

Workplace drug and alcohol testing has been widely implemented in diverse industries and is designed to detect the use of and deter the influence of legal and illegal substances that would impair the ability to perform work that has significant security and safety implications. Across the globe, patterns of drug and alcohol use and abuse and the regulations controlling drug and alcohol use vary by location (e.g., regions, countries, etc.). The prevalence of workplace drug and alcohol testing and protection of individuals’ rights in the workplace similarly tend to exhibit contextual differences. With the advancements in drug-testing technologies and the recent issuance of guidance for additional testing matrices (e.g., oral fluid, hair, etc.) by the U.S. Department of Health and Human Services, gaining a global perspective on the current state of drug and alcohol testing practices and regulations is important for leveraging such advancements to improve the effectiveness of drug and alcohol testing. The U.S. Nuclear Regulatory Commission (NRC) tasked the Pacific Northwest National Laboratory (PNNL) fitness for duty (FFD) team to conduct a benchmarking analysis of international drug and alcohol testing regulations and programs to identify similarities and differences in workplace testing programs and the basis for any differences. The benchmarking study focuses on a policy analysis and benchmarking metrics comparison among different countries and regions. The policy analysis includes the following three types of relevant international and national policies relevant to drug and alcohol testing in the nuclear industry: 1. National drug and alcohol policy 2. Workplace drug and alcohol testing 3. FFD regulations for Nuclear Power Plants The international drug and alcohol benchmarking metrics focusses on the use of blood, breath, urine, hair, and oral fluid in testing; drug and drug metabolite cutoff values; point-of-collection testing devices; roadside testing methodologies; innovations in drug testing; and the extent of availability of such data. Gaining an understanding of workplace drug and alcohol testing in other countries as well as information about new testing methods, matrices, tools, and technologies that other countries have adopted provides NRC with international comparative information regarding the technical basis for such programs and methods as it relates to the protection of worker and public health and safety.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Assessment and Coordination of EVSE Cybersecurity Standards

Cybersecurity certification programs for Electric Vehicle Supply Equipment (EVSE) are fragmented due to no single certification covering all aspects of the device and additionally the existence of multiple programs and under different levels of regulation. These devices are also confronted by the intricate assembly of product software, firmware, and hardware. Devices contain both logical and physical interfaces. These multifaceted devices have vulnerabilities at many levels and interconnect with other potentially vulnerable systems including the electric vehicle, the cloud where data and payment information are stored, and the electric grid and electric grid equipment including utilities. Of the EVSE certification programs that are found, none are directly for the cybersecurity of EVSE. Many standards are for safety, specifically battery safety, some are cybersecurity standards for other types of equipment and can be modeled for EVSE. In specific, ISA/IEC 62443 is found to be significantly in line with EVSE security needs and will be used in future testing to certify EVSE and help guide the project to demonstrate where gaps exist, where strengths lie in the standard and how this can be used to lead the certification efforts in harmonizing EVSE cybersecurity standards. In addition, there are multiple efforts that are currently seeking to build EVSE standards or revise existing standards to address gaps. This effort is seeking to establish a cybersecurity program for EVSE that will inform customers and help increase the level of security across products and state EVSE procurements to achieve consistency across different jurisdictions.

33 ADVANCED PROPULSION SYSTEMS↗

Low-Cost III-V Photovoltaic Materials by Chloride Vapor Transport Deposition Using Safe Solid Precursors

Si-based photovoltaic devices dominate the market. As photovoltaic (PV) manufacturing costs have plummeted, technologies which increase efficiency have become critical. Si cell efficiencies are nearing theoretical limits and Si-based PV modules are unlikely to reach the 25-30% efficiency range. The use of III-V semiconductors is an obvious technical solution to improve efficiency, especially if they can be integrated directly with existing Si technology as tandems. High coefficients of light absorption along with tunable bandgaps and lattice constants have resulted in record conversion efficiencies for both one-sun and concentrator PV applications. GaAs, for example, has been used to manufacture single-junction photovoltaics with world-record efficiencies of 28.8% at one sun.2 However, costs for III-Vs must be dramatically reduced to produce cost-effective, high-efficiency PV solutions. III-V costs are controlled by two factors: semiconductor growth and the substrate. III-V growth is dominated today by metal-organic vapor phase epitaxy (MOVPE) with a lesser role played by molecular beam epitaxy (MBE). MOVPE costs are high due to the expense and low utilization (~30%) of precursors, modest growth rates (~100 nm min -1 ), equipment complexity, and safety infrastructure needed to handle toxic, pyrophoric gases.3 MBE costs are high due to slow growth rates and limitations of scalability. Details comparing plausible low-cost III-V growth methods are available in a review article published as a result of this project. The primary goal of this project was to demonstrate that close-spaced vapor transport (CSVT) using chloride (from HCl) as a transport agent can be used for the rapid growth of device-ready III-V layers from safe, solid-source precursors. In pursuit of this goal, we designed, built, and installed a new Cl-CSVT reactor based on insights from our previous H 2 O-CSVT growth system and in collaboration with equipment professionals at Malachite Technologies. This system was successfully used to grow epitaxial GaAs with controlled n-type doping, having mobilities similar to MOVPE. Detailed technical information and results can also be found in the primary publication resulting from this project. This work sets the stage for tackling the development of high-performance III-V single junctions and tandem devices directly on Si substrates, which was beyond the capabilities of our H2O-CSVT system. The design of the reactor’s source and substrate transfer system should allow for direct deposition of device structures. The collective innovations of our Cl-CSVT system might ultimately serve as an enabling process for commercialization of the technology through a collaboration with appropriate industrial partners.

14 SOLAR ENERGY↗

5 G wireless telecommunications expansion: Public health and environmental implications

The popularity, widespread use and increasing dependency on wireless technologies has spawned a telecommunications industrial revolution with increasing public exposure to broader and higher frequencies of the electromagnetic spectrum to transmit data through a variety of devices and infrastructure. On the horizon, a new generation of even shorter high frequency 5G wavelengths is being proposed to power the Internet of Things (IoT). The IoT promises us convenient and easy lifestyles with a massive 5G interconnected telecommunications network, however, the expansion of broadband with shorter wavelength radiofrequency radiation highlights the concern that health and safety issues remain unknown. Controversy continues with regards to harm from current 2G, 3G and 4G wireless technologies. 5G technologies are far less studied for human or environmental effects. }It is argued that the addition of this added high frequency 5G radiation to an already complex mix of lower frequencies, will contribute to a negative public health outcome both from both physical and mental health perspectives. }Radiofrequency radiation (RF) is increasingly being recognized as a new form of environmental pollution. Like other common toxic exposures, the effects of radiofrequency electromagnetic radiation (RF EMR) will be problematic if not impossible to sort out epidemiologically as there no longer remains an unexposed control group. This is especially important considering these effects are likely magnified by synergistic toxic exposures and other common health risk behaviors. Effects can also be non-linear. Because this is the first generation to have cradle-to-grave lifespan exposure to this level of man-made microwave (RF EMR) radiofrequencies, it will be years or decades before the true health consequences are known. Precaution in the roll out of this new technology is strongly indicated. }This article will review relevant electromagnetic frequencies, exposure standards and current scientific literature on the health implications of 2G, 3G, 4G exposure, including some of the available literature on 5G frequencies. The question of what constitutes a public health issue will be raised, as well as the need for a precautionary approach in advancing new wireless technologies.

54 ENVIRONMENTAL SCIENCES↗

Development of electrostatic precipitator (ESP) technology to remove elemental mercury vapor, HG(0)

The presence of mercury vapor or other forms of mercury presents issues with worker safety, decommissioning facilities, and environmental impacts. As such, it is desired to develop a strategy to either remove or reduce mercury levels in Oak Ridge’s Y-12 Complex facilities. A testing methodology was developed to evaluate electrostatic precipitator technology for removal of mercury vapor. This methodology involved supplying mercury vapor-containing air to the ESP device by flowing air through a column containing alternating layers of sand and liquid mercury droplets. Initial attempts at quantifying the efficacy of the ESP device in removing mercury vapor were plagued with difficulties in controlling the flow of mercury into the ESP device due to poor performance of the generator column and the contamination of these experiments with mercury from an unknown source. These issues were resolved by creating a new generator column with slower air velocity and higher surface area of liquid mercury, along with moving the air intake for the ESP device to outside of the chemical hood in which testing took place. This resulted in a steady, quantified flow of mercury vapor from the generator column and no observation of unintended mercury sources. A final test of the ESP device under these controlled conditions showed that for a certain amount of time (on the order of 20-30 minutes) mercury concentrations were reduced by approximately 33 - 67% of the inlet concentration. However, episodic releases or pulses of mercury observed only at the outlet indicated that the mercury accumulated in the ESP device is periodically expelled. As a result, it was not deemed to be an efficient strategy for the removal of elemental mercury vapor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ionic Polymers Under Dynamic Conditions

Combining neutron scattering tools and exascale molecular dynamics simulations, research was carried out to resolve the structure and motion of ionic polymers under dynamic conditions. Ionizable polymers constitute a key component in current and potential transformative lightweight energy generation and storage devices. However, the inherent segregation of these polymers to ionic clusters and non-ionic domains, or clusters, that on one hand enables their function, confines the dynamics of the polymer chains, leading to the formation of far-from equilibrium states. These non-equilibrium states morph under in situ conditions, affecting the performance-longevity-safety-cost foundation that underlines the use of these polymers. On route to controlling the assemblies of ionizable polymers into stable functional materials, the research focused on a) understanding the inherent confinement of the polymer chains by the ionic clusters and b) resolving of the response of these polymers to flow fields that are integral to the processing and function of these macromolecules.

36 MATERIALS SCIENCE↗

D and D decision model and mobile application for selection of fixative, strippable coating, and decontamination gel products - 15696

Deactivation and decommissioning (D and D) is the process of taking an active/excess/abandoned facility to a final disposition end state. D and D presents unique hazards that must be addressed from a safety, programmatic, environmental, and technological standpoint. This definition is especially applicable to Savannah River Site's 235-F facility. The facility was constructed in the 1950's as part of the weapons complex materials production and fabrication. The most significant quantities of residual contamination remaining in 235-F building is in the form of Plutonium-238. A Decision Model was created using MatLab to work hand-in-hand with a product list containing commercially available D and D products. This model was created to further enhance and accelerate the decontamination process. It is envisioned that D and D engineers will be able to use this Decision Model in the field via a mobile device. It allows the user to select four inputs to match their situation. The model searches the database and returns the products that fit the criteria selected by the user. This Decision Model will be made available in a web-based application and as a mobile application to ensure end users can access it when needed. The MatLab code recognizes what position in the text box is selected and then this input is converted to the corresponding string. The string is then compared with the information in the product list in the specified column in order to reduce processing time. Then the products that contain the string inputted are displayed on the table and are separated by category. The web-based version of the model will receive three specified criteria and sub-criteria from the user and update the table with products that fit each criteria. A web-based version of this Decision Model is under way and will be set up on the D and D KM-IT platform. There will be two versions of this mobile application: for devices with internet connection and for those that do not have internet connection. This will ensure end users have access to the Decision application at any time or place during the D and D process. A mobile version of the model will also be developed in the near future.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogel Spacer Prospective Multicenter Randomized Controlled Pivotal Trial: Dosimetric and Clinical Effects of Perirectal Spacer Application in Men Undergoing Prostate Image Guided Intensity Modulated Radiation Therapy

Purpose: Perirectal spacing, whereby biomaterials are placed between the prostate and rectum, shows promise in reducing rectal dose during prostate cancer radiation therapy. A prospective multicenter randomized controlled pivotal trial was performed to assess outcomes following absorbable spacer (SpaceOAR system) implantation. Methods and Materials: Overall, 222 patients with clinical stage T1 or T2 prostate cancer underwent computed tomography (CT) and magnetic resonance imaging (MRI) scans for treatment planning, followed with fiducial marker placement, and were randomized to receive spacer injection or no injection (control). Patients received postprocedure CT and MRI planning scans and underwent image guided intensity modulated radiation therapy (79.2 Gy in 1.8-Gy fractions). Spacer safety and impact on rectal irradiation, toxicity, and quality of life were assessed throughout 15 months. Results: Spacer application was rated as “easy” or “very easy” 98.7% of the time, with a 99% hydrogel placement success rate. Perirectal spaces were 12.6 ± 3.9 mm and 1.6 ± 2.0 mm in the spacer and control groups, respectively. There were no device-related adverse events, rectal perforations, serious bleeding, or infections within either group. Pre-to postspacer plans had a significant reduction in mean rectal V70 (12.4% to 3.3%, P<.0001). Overall acute rectal adverse event rates were similar between groups, with fewer spacer patients experiencing rectal pain (P=.02). A significant reduction in late (3-15 months) rectal toxicity severity in the spacer group was observed (P=.04), with a 2.0% and 7.0% late rectal toxicity incidence in the spacer and control groups, respectively. There was no late rectal toxicity greater than grade 1 in the spacer group. At 15 months 11.6% and 21.4% of spacer and control patients, respectively, experienced 10-point declines in bowel quality of life. MRI scans at 12 months verified spacer absorption. Conclusions: Spacer application was well tolerated. Increased perirectal space reduced rectal irradiation, reduced rectal toxicity severity, and decreased rates of patients experiencing declines in bowel quality of life. The spacer appears to be an effective tool, potentially enabling advanced prostate RT protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Critical Unresolved Region Integral Experiment (MCURIE): A Proposed Integral Critical Experimental Framework for Unresolved Region and Intermediate Energies

The Critical Unresolved Region Integral Experiment (CURIE) critical experiment was performed at the National Criticality Experiments Research Center (NCERC) at the Device Assembly Facility (DAF) at the Nevada Nuclear Security Sites (NNSS) in 2020. The objective of CURIE was to improve the quality of integral nuclear data in the uranium-235 ( 235 U) unresolved resonance region (URR) by performing benchmark integral experiments that were sensitive to the URR energy ranges. The CURIE experiment was evaluated for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook and the benchmark evaluation was accepted in 2022. The URR is a region within the intermediate neutron energy range (the intermediate energy ranges from 0.7 eV to 100 keV). The observed resonance structure in neutron cross sections is due to discrete energy levels in the nucleus and are characterized by resonance parameters. In the URR region, the resonance parameters are only partially resolved as the resolution of the experiment techniques becomes comparable to the average width of the resonances themselves, and the resonances are so close to one another that the structure cannot be determined empirically. The ENDF/B-VIII.0 and JEFF-3.3 nuclear data libraries define the URR as beginning at 2.25 keV and continuing until 25 keV. There are minimal intermediate neutron energy benchmarks available in the ICSBEP benchmark handbook, and aside from CURIE there are none that are highly sensitive in the URR energy region. There is a current need for additional experiments sensitive to the URR energy region. There is a new proposed subgroup for the Organization for Economic Co-operation and Development and Nuclear Energy Agency (OECD NEA) Working Party on International Nuclear Data Evaluation Cooperation (WPEC), so any new models or information will need experimental validation and testing. The NEA Working Party on Nuclear Criticality Safety (WPNCS) recent experimental needs and priority list includes intermediate energy 235 U and 238 U experiments, as does the recent Integral Experiments to Address Nuclear Criticality Safety Needs Meeting (May 2023). A variant on the original CURIE experiment called the Multiple Critical Unresolved Region Integral Experiment (MCURIE) is proposed to provide further investigation of the intermediate and URR energy region for uranium. MCURIE will utilize existing fuels at NCERC but use alternative moderators and reflectors to modify the neutron absorption, scattering, and fission spectra of the experiments, allowing for precise targeting of nuclear data sensitivities. The overall goal of MCURIE is to develop a framework for designing and performing integral benchmark experiments with high sensitivities in the intermediate and URR energy regions for nuclear data validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated Security-Safety Consequence Study of a Heat Pipe Reactor

This report presents a preliminary demonstration of integrated security/safety consequence modeling to support potential physical security exemption justifications under the new Title 10 Code of Federal Regulations Part 53 licensing pathway, which allows exemptions if sabotage-induced radiological consequences do not exceed 25 rem at the site boundary two hours after release without mitigative actions. A hypothetical heat pipe microreactor subjected to direct sabotage by a 150 lbs. TNT-equivalent high-explosive device was analyzed using a simplified radionuclide release estimate based on DOE-HDBK-3010-94, implemented in the MELCOR severe accident analysis code to model release transport and attenuation through reactor/building compartments, with MELCOR outputs coupled to MACCS to compute offsite doses and the distance-to-threshold metric D 25rem . Six scenarios were evaluated to examine sensitivities to release pathway/building configuration and radionuclide form (vapor versus aerosols with different size distributions). Results show a positive correlation between leak path factor and D 25rem and indicate that reactor building compartmentalization can substantially reduce consequences (a single-story configuration reduced D 25rem by roughly an order of magnitude relative to a cavity-only configuration), while vapor versus aerosol assumptions had limited impact for the modeled two-story case on the spatial grid used.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Kilopower Project: The KRUSTY Fission Power Experiment and Potential Missions

The Kilopower Project was initiated by NASA’s Space Technology Mission Directorate/Game Changing Development Program in fiscal year 2015 to demonstrate subsystem-level technology readiness of small space fission power in a relevant environment (Technology Readiness Level 5) for space science and human exploration power needs. The Kilopower Project centerpiece is the Kilowatt Reactor Using Stirling TechnologY (KRUSTY) test, which consists of the development and testing of a ground technology demonstrator of a 1-kW(electric)–class fission power system (FPS). The technologies to be developed and validated by KRUSTY are extensible to space FPSs from 1 to 10 kW(electric), which can enable modular surface FPSs for human exploration as well as higher-power future potential deep space science missions. The KRUSTY demonstration is cofunded by NASA and the U.S. Department of Energy National Nuclear Security Administration. The KRUSTY demonstration in the National Critical Experiment Research Center’s Device Assembly Facility was completed in the first quarter of 2018.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery

Purpose: Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution intravascular images. The authors report the safety and feasibility and illustrate common imaging findings of frequency-domain OCT (FD-OCT) imaging of the femoropopliteal artery in a series of 20 patients who underwent infrainguinal angioplasty. Methods: After crossing the lesion of interest, OCT was performed with a dextrose saline flush technique with simultaneous obstructive manual groin compression. An automatic pullback FD-OCT device was employed (each scan acquiring 54 mm of vessel lumen in 271 consecutive frames). OCT images were acquired before and after balloon dilatation and following provisional stenting if necessary and were evaluated for baseline characteristics of plaque or in-stent restenosis (ISR), vessel wall trauma after angioplasty, presence of thrombus, stent apposition, and tissue prolapse. Imaging follow-up was not included in this study's protocol. Results: Twenty-seven obstructive lesions (18 cases of de novo atherosclerosis and 9 of ISR) of the femoropopliteal artery were imaged and 148 acquisitions were analyzed in total. High-resolution intravascular OCT imaging with effective blood clearance was achieved in 93.9%. Failure was mainly attributed to preocclusive proximal lesions and/or collateral flow. Mixed features of lipid pool areas, calcium deposits, necrotic core, and fibrosis were identified in all of the imaged atherosclerotic lesions, whereas ISR was purely fibrotic. After balloon angioplasty, OCT identified extensive intimal tears in all cases and one case of severe dissection that biplane subtraction angiography failed to identify. Conclusions: Infrainguinal frequency-domain optical coherence tomography is safe and feasible and may provide intravascular high-resolution imaging of the femoropopliteal artery during infrainguinal angioplasty procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of harsh environment operation of flexible ferroelectric memory integrated with PZT and silicon fabric

Flexible memory can enable industrial, automobile, space, and smart grid centered harsh/extreme environment focused electronics application(s) for enhanced operation, safety, and monitoring where bent or complex shaped infrastructures are common and state-of-the-art rigid electronics cannot be deployed. Therefore, we report on the physical-mechanical-electrical characteristics of a flexible ferroelectric memory based on lead zirconium titanate as a key memory material and flexible version of bulk mono-crystalline silicon (100). The experimented devices show a bending radius down to 1.25 cm corresponding to 0.16% nominal strain (high pressure of ∼260 MPa), and full functionality up to 225 °C high temperature in ambient gas composition (21% oxygen and 55% relative humidity). The devices showed unaltered data retention and fatigue properties under harsh conditions, still the reduced memory window (20% difference between switching and non-switching currents at 225 °C) requires sensitive sense circuitry for proper functionality and is the limiting factor preventing operation at higher temperatures.

36 MATERIALS SCIENCE↗