Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Robot”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Extra Robotic Legs for Bearing Equipment Loads During Emergency Response - 19532

The Extra Robotic Legs (XRL) system is a robotic augmentation worn by a human operator that consists of two articulated robot legs that help bear a heavy backpack payload and the operator's own weight. The design was driven by a need to increase the effectiveness of Department of Energy hazardous material emergency response personnel who are encumbered by their Personal Protective Equipment. A prototype was fabricated utilizing insights gained from force analyses and human-robot interaction safety requirements. A seamless hybrid control architecture was developed to allow the operator command over the pace of the stand-to-squat transition. Initial tests of balance control while performing squatting transitions indicate the feasibility of the XRL System. The legs will ultimately walk, climb stairs, crouch down, and crawl with the operator while eliminating all equipment loads on the operator. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robotic Solutions for Remote Access and Retrieval of High-Level Radioactive Waste - 19544

This paper describes the ongoing development of robotic solutions for accessing and retrieving high-level radioactive waste from underground storage bins as part of the Calcine Retrieval Project at the INL Site. The waste is in the form of a solid powder, referred to as calcine, stored in a set of stainless steel bins within an underground concrete vault. Due to the radiation field produced by the calcine, all operations must be performed remotely. The Calcine Retrieval Project is currently carrying out proof-of-concept testing of methods for the various stages of calcine retrieval. The bins were designed with no means for access, so retrieval operations will require welding access riser pipes to the bins, followed by cutting through the bin walls from within the risers. These tasks are complicated by the fact that four of the risers must be placed off center on a domed surface, resulting in a weld joint that is curved and tilted relative to the riser axis. The Access Riser Connection robot is being developed to perform these operations using interchangeable welding and plasma cutting attachments. The majority of the calcine will be removed using a vacuum system and pneumatically transferred to storage. This system is not described in this paper. However, the bins contain several internal features that are expected to retain calcine, most notably circumferential stiffening rings on the walls and radial ribs on the floors. One of the solutions being developed for the task of retrieving this residual calcine is a vacuum crawler, a wheeled robot using vacuum to adhere to the interior walls of the bins. The vacuum crawler would use a separate vacuum system to remove residual calcine or would use compressed air to move calcine to a location from which it can be retrieved more easily. While comparable welding and wall-climbing robots have been developed before, this particular application has several constraints that are not satisfied by existing systems. For this reason, both the access riser welder and the vacuum crawler, although still under development, may be of interest to other projects faced with similar constraints. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kinematics of a Cable-Driven Robotic Platform for Large-Scale Additive Manufacturing

Concrete additive manufacturing (AM) is a growing field of research. However, on-site, large-scale concrete additive manufacturing requires motion platforms that are difficult to implement with conventional rigid-link robotic systems. This article presents a new kinematic arrangement for a deployable cable-driven robot intended for on-site AM. The kinematics of this robot are examined to determine if they meet the requirements for this application, the wrench feasible workspace (WFW) is examined, and the physical implementation of a prototype is also presented. Data collected from the physical implementation of the proposed system are analyzed, and the results support its suitability for the intended application. The success of this system demonstrates that this kinematic arrangement is promising for future deployable AM systems.

36 MATERIALS SCIENCE↗

A Retrospective Comparison of Robotic Stereotactic Body Radiotherapy and Three-Dimensional Conformal Radiotherapy for the Reirradiation of Locally Recurrent Nasopharyngeal Carcinoma

Purpose: We assessed therapeutic outcomes of reirradiation with robotic stereotactic radiotherapy (SBRT) for locally recurrent nasopharyngeal carcinoma (LRNPC) patients and compared those results with three-dimensional conformal radiotherapy (CRT) with or without brachytherapy (BRT). Methods and Materials: Treatment outcomes were evaluated retrospectively in 51 LRNPC patients receiving either robotic SBRT (24 patients) or CRT with or without BRT (27 patients) in our department. CRT was delivered with a 6-MV linear accelerator, and a median total reirradiation dose of 57 Gy in 2 Gy/day was given. Robotic SBRT was delivered with CyberKnife (Accuray, Sunnyvale, CA). Patients in the SBRT arm received 30 Gy over 5 consecutive days. We calculated actuarial local control and cancer-specific survival rates for the comparison of treatment outcomes in SBRT and CRT arms. The Common Terminology Criteria for Adverse Events v3.0 was used for toxicity evaluation. Results: The median follow-up was 24 months for all patients. Two-year actuarial local control rates were 82% and 80% for SBRT and CRT arms, respectively (p = 0.6). Two-year cancer-specific survival rates were 64% and 47% for the SBRT and CRT arms, respectively (p = 0.4). Serious late toxicities (Grade 3 and above) were observed in 21% of patients in the SBRT arm, whereas 48% of patients had serious toxicity in the CRT arm (p = 0.04). Fatal complications occurred in three patients (12.5%) of the SBRT arm, and four patients (14.8%) of the CRT arm (p = 0.8). T stage at recurrence was the only independent predictor for local control and survival. Conclusion: Our robotic SBRT protocol seems to be feasible and less toxic in terms of late effects compared with CRT arm for the reirradiation of LRNPC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Robotic Radiosurgical Liver Treatment Throughout the Respiratory Cycle

Purpose: To quantify random uncertainties in robotic radiosurgical treatment of liver lesions with real-time respiratory motion management. Methods and Materials: We conducted a retrospective analysis of 27 liver cancer patients treated with robotic radiosurgery over 118 fractions. The robotic radiosurgical system uses orthogonal x-ray images to determine internal target position and correlates this position with an external surrogate to provide robotic corrections of linear accelerator positioning. Verification and update of this internal–external correlation model was achieved using periodic x-ray images collected throughout treatment. To quantify random uncertainties in targeting, we analyzed logged tracking information and isolated x-ray images collected immediately before beam delivery. For translational correlation errors, we quantified the difference between correlation model–estimated target position and actual position determined by periodic x-ray imaging. To quantify prediction errors, we computed the mean absolute difference between the predicted coordinates and actual modeled position calculated 115 milliseconds later. We estimated overall random uncertainty by quadratically summing correlation, prediction, and end-to-end targeting errors. We also investigated relationships between tracking errors and motion amplitude using linear regression. Results: The 95th percentile absolute correlation errors in each direction were 2.1 mm left–right, 1.8 mm anterior–posterior, 3.3 mm cranio–caudal, and 3.9 mm 3-dimensional radial, whereas 95th percentile absolute radial prediction errors were 0.5 mm. Overall 95th percentile random uncertainty was 4 mm in the radial direction. Prediction errors were strongly correlated with modeled target amplitude (r=0.53-0.66, P<.001), whereas only weak correlations existed for correlation errors. Conclusions: Study results demonstrate that model correlation errors are the primary random source of uncertainty in Cyberknife liver treatment and, unlike prediction errors, are not strongly correlated with target motion amplitude. Aggregate 3-dimensional radial position errors presented here suggest the target will be within 4 mm of the target volume for 95% of the beam delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The need for reproducible research in soft robotics

In recent years we have witnessed the rise of commercialization efforts for soft robotic technology, including soft grippers (Soft Robotics, Inc.), stretchable sensors (StretchSense, Inc. and Lightlace, Inc.), and platforms for human-robot interaction (Festo Inc., Meta Reality Labs, Toyota Research Institute, and Disney Research). However, commercialization as a whole lags the trends enjoyed by other robotic technology at equivalent points in their respective lifecycles.

43 PARTICLE ACCELERATORS↗

Navigating phase diagram complexity to guide robotic inorganic materials synthesis

Abstract Efficient synthesis recipes are needed to streamline the manufacturing of complex materials and to accelerate the realization of theoretically predicted materials. Often, the solid-state synthesis of multicomponent oxides is impeded by undesired by-product phases, which can kinetically trap reactions in an incomplete non-equilibrium state. Here we report a thermodynamic strategy to navigate high-dimensional phase diagrams in search of precursors that circumvent low-energy, competing by-products, while maximizing the reaction energy to drive fast phase transformation kinetics. Using a robotic inorganic materials synthesis laboratory, we perform a large-scale experimental validation of our precursor selection principles. For a set of 35 target quaternary oxides, with chemistries representative of intercalation battery cathodes and solid-state electrolytes, our robot performs 224 reactions spanning 27 elements with 28 unique precursors, operated by 1 human experimentalist. Our predicted precursors frequently yield target materials with higher phase purity than traditional precursors. Robotic laboratories offer an exciting platform for data-driven experimental synthesis science, from which we can develop fundamental insights to guide both human and robotic chemists.

Chen, Jiadong (ORCID:0009000476038838)↗

A Model Based Approach to Increase the Part Accuracy in Robot Based Incremental Sheet Metal Forming

One main influence on the dimensional accuracy in robot based incremental sheet metal forming results from the compliance of the involved robot structures. Compared to conventional machine tools the low stiffness of the robot's kinematic results in a significant deviation of the planned tool path and therefore in a shape of insufficient quality. To predict and compensate these deviations offline, a model based approach, consisting of a finite element approach, to simulate the sheet forming, and a multi body system, modeling the compliant robot structure, has been developed. This paper describes the implementation and experimental verification of the multi body system model and its included compensation method.

36 MATERIALS SCIENCE↗

Synthetic Fiber Capstan Drives for Highly Efficient, Torque Controlled, Robotic Applications

Here this paper describes the design and performance of a synthetic rope on sheave drive system. This system uses synthetic ropes instead of steel cables to achieve low weight and a compact form factor. We demonstrate how this system is capable of 28-Hz torque control bandwidth, 95% efficiency, and quiet operation, making it ideal for use on legged robots and other dynamic physically interactive systems. Component geometry and tailored maintenance procedures are used to achieve high endurance. Endurance tests based on walking data predict that the ropes will survive roughly 247,000 cycles when used on large (90 kg), fully actuated bipedal robot systems. The drive systems have been incorporated into two novel bipedal robots capable of three-dimensional unsupported walking. Robot data illustrate effective torque tracking and nearly silent operation. Finally, comparisons with alternative transmission designs illustrate the size, weight, and endurance advantages of using this type of synthetic rope drive system.

42 ENGINEERING↗

Parallel elastic elements improve energy efficiency on the STEPPR bipedal walking robot

This study describes how parallel elastic elements can be used to reduce energy consumption in the electric motor driven, fully-actuated, STEPPR bipedal walking robot without compromising or significantly limiting locomotive behaviors. A physically motivated approach is used to illustrate how selectively-engaging springs for hip adduction and ankle flexion predict benefits for three different flat ground walking gaits: human walking, human-like robot walking and crouched robot walking. Based on locomotion data, springs are designed and substantial reductions in power consumption are demonstrated using a bench dynamometer. These lessons are then applied to STEPPR (Sandia Transmission-Efficient Prototype Promoting Research), a fully actuated bipedal robot designed to explore the impact of tailored joint mechanisms on walking efficiency. Featuring high-torque brushless DC motors, efficient low-ratio transmissions, and high fidelity torque control, STEPPR provides the ability to incorporate novel joint-level mechanisms without dramatically altering high level control. Unique parallel elastic designs are incorporated into STEPPR, and walking data shows that hip adduction and ankle flexion springs significantly reduce the required actuator energy at those joints for several gaits. These results suggest that parallel joint springs offer a promising means of supporting quasi-static joint torques due to body mass during walking, relieving motors of the need to support these torques and substantially improving locomotive energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TH-C-BRC-02: A Review of Emerging Technologies in Robotic SRS/SBRT Delivery

The delivery techniques for SRS/SBRT have been under rapid developments in recent years, which pose new challenges to medical physicists ranging from planning and quality assurance to imaging and motion management. This educational course will provide a general overview of the latest delivery techniques in SRS/SBRT, and discuss the clinical processes to address the challenges of each technique with special emphasis on dedicated gamma-ray based device, robotic x-band linac-based system and conventional C-arm s-band linac-based SRS systems. (1). Gamma-ray based SRS/SRT: This is the gold standard of intracranial SRS. With the advent of precision imaging guidance and frameless patient positioning capabilities, novel stereoscopic CBCT and automatic dose adaption solution are introduced to the Gamma-ray based SRS for the first time. The first North American system has been approved by the US regulatory for patient treatments in the spring of 2016. (2). Robotic SRS/SBRT system: A number of technological milestones have been developed in the past few years, including variable aperture collimator, sequential optimization technique, and the time reduction technique. Recently, a new robotic model allows the option of a multi-leaf collimator. These technological advances have reduced the treatment time and improved dose conformity significantly and could potentially expand the application of radiosurgery for the treatment of targets not previously suitable for robotic SRS/SBRT or fractionated stereotactic radiotherapy. These technological advances have created new demanding mandates on hardware and patient quality assurance (QA) tasks, as well as the need for updating/educating the physicists in the community on these requirements. (3). Conventional Linac based treatments: Modulated arc therapy (MAT) has gained wide popularities in Linac-based treatments in recent years due to its high delivery efficiency and excellent dose conformities. Recently, MAT has been introduced to deliver highly conformal radiosurgery treatments to multiple targets simultaneously via a single isocenter to replace the conventional multi-iso multi-plan treatments. It becomes important to understand the advantages and limitations of this technique, and the pitfalls for implementing this technique in clinical practice. The planning process of single-iso multi-target MAT will be described, and its plan quality and delivery efficiency will be compared with multi-iso plans. The QA process for verifying such complex plans will be illustrated, and pitfalls in imaging and patient set up will be discussed. Overall, this session will focus on the following areas: 1) Update on the emerging technology in current SRS/SBRT delivery. 2) New developments in treatment planning and Quality Assurance program. 3) Imaging guidance and motion management. Learning Objectives: To understand the SRS/SBRT principles and its clinical applications, and gain knowledge on the emerging technologies in SRS/SBRT. To review planning concepts and useful tips in treatment planning. To learn about the imaging guidance procedures and the quality assurance program in SRS/SBRT. National Institutes of Health, Varian Medical System; L. Ren, The presenter is funded by National Institutes of Health and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

ROBOT: A Tool for Automating Ontology Workflows

BACKGROUND:Ontologies are invaluable in the life sciences, but building and maintaining ontologies often requires a challenging number of distinct tasks such as running automated reasoners and quality control checks, extracting dependencies and application-specific subsets, generating standard reports, and generating release files in multiple formats. Similar to more general software development, automation is the key to executing and managing these tasks effectively and to releasing more robust products in standard forms. For ontologies using the Web Ontology Language (OWL), the OWL API Java library is the foundation for a range of software tools, including the Protégé ontology editor. In the Open Biological and Biomedical Ontologies (OBO) community, we recognized the need to package a wide range of low-level OWL API functionality into a library of common higher-level operations and to make those operations available as a command-line tool. RESULTS:ROBOT (a recursive acronym for "ROBOT is an OBO Tool") is an open source library and command-line tool for automating ontology development tasks. The library can be called from any programming language that runs on the Java Virtual Machine (JVM). Most usage is through the command-line tool, which runs on macOS, Linux, and Windows. ROBOT provides ontology processing commands for a variety of tasks, including commands for converting formats, running a reasoner, creating import modules, running reports, and various other tasks. These commands can be combined into larger workflows using a separate task execution system such as GNU Make, and workflows can be automatically executed within continuous integration systems. CONCLUSIONS:ROBOT supports automation of a wide range of ontology development tasks, focusing on OBO conventions. It packages common high-level ontology development functionality into a convenient library, and makes it easy to configure, combine, and execute individual tasks in comprehensive, automated workflows. This helps ontology developers to efficiently create, maintain, and release high-quality ontologies, so that they can spend more time focusing on development tasks. It also helps guarantee that released ontologies are free of certain types of logical errors and conform to standard quality control checks, increasing the overall robustness and efficiency of the ontology development lifecycle.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Argonaut - A Robotic System for Cryogenic Environments

Fermilab and the HEP community invest significant resources into liquid argon detectors. The largest and most expensive of these detectors will be located in the Deep Underground Neutrino Experiment (DUNE). However, recent experiences have shown that there are limited avenues of monitoring, intervention, and interaction in the internal liquid environment. This proposal shows a technological path that could provide a valuable tool to ensure or at least improve the management of these HEP detectors. The development of a robotic system named Argonaut will demonstrate several technologies including 1) demonstration of suitable mobility of a small robotic device at liquid argon temperatures, 2) demonstration of wireless communication, 3) demonstration of improved diagnostics capabilities - such as tunable optics with motion control, 4) demonstration of interconnectivity of a robotic system with hardware residing within the detector. This initial research will be a seed for extended development in cold robotics and associated technologies. This work will allow FNAL to contribute a significant technology capability to recent efforts to cryogenic detector operations.

43 PARTICLE ACCELERATORS↗

Gamma-Ray Raster Imaging with Robotic Data Collection (FY19 Annual Report)

This project has developed an alternative imaging capability for imaging and quantifying radioactive materials in situ. This approach uses a robotic-mounted gamma-ray detector which can move around an area of interest, sampling the space at a high frequency. By rastering across the area, an image can be created with no collimation and a high efficiency. An open-source robotic platform was programed to search an open area, collecting gamma-ray spectra every second. Informative path planning was used to direct the robot to areas of higher dose. Finally, a Bayesian particle filter was used to locate the source with minimal counting statistics. The use of a robotic mount allows data collection for long periods of time unattended, and it will also eliminate uncertainties in positioning typically introduced by personnel. This approach will be particularly relevant for gloveboxes, shielded cells, or process piping which may have complex, non-uniform distributions of material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using ROS for Robotic Control [Slides]

The use of robots is important, to help prevent people from being exposed to hazardous materials within a glovebox. The research proposal for the summer was to make a pick and place demo for a seven degrees-of-freedom Motoman Sia5d robot. The Robot Operating System (ROS) was used and the knowledge of C++ and Linux had to be applied. The robot was used to pick up and sort four objects (cylinder, sphere, rectangular prism, and cone) within a virtual environment.

42 ENGINEERING↗

In-Situ Sensing and Dynamics Predictions for Electrothermally-Actuated Soft Robot Limbs

Untethered soft robots that locomote using electrothermally-responsive materials like shape memory alloy (SMA) face challenging design constraints for sensing actuator states. At the same time, modeling of actuator behaviors faces steep challenges, even with available sensor data, due to complex electrical-thermal-mechanical interactions and hysteresis. This article proposes a framework for in-situ sensing and dynamics modeling of actuator states, particularly temperature of SMA wires, which is used to predict robot motions. A planar soft limb is developed, actuated by a pair of SMA coils, that includes compact and robust sensors for temperature and angular deflection. Data from these sensors are used to train a neural network-based on the long short-term memory (LSTM) architecture to model both unidirectional (single SMA) and bidirectional (both SMAs) motion. Predictions from the model demonstrate that data from the temperature sensor, combined with control inputs, allow for dynamics predictions over extraordinarily long open-loop timescales (10 min) with little drift. Prediction errors are on the order of the soft deflection sensor’s accuracy. This architecture allows for compact designs of electrothermally-actuated soft robots that include sensing sufficient for motion predictions, helping to bring these robots into practical application.

Sabelhaus, Andrew P.↗

Tracking Robot Location for Non-Destructive Evaluation of Double-Shell Tanks

(1) Background: Non-destructive evaluation of double-shell nuclear-waste storage tanks at the U.S. Department of Energy’s Hanford site requires a robot to navigate a network of air slots in the confined space between primary and secondary tanks. Situational awareness, data collection, and data interpretation require continuous tracking of the robot’s location. (2) Methods: Robot location is continuously monitored using video image analysis for short distances and laser ranging for absolute location. (3) Results: The technique was demonstrated in our laboratory using a mockup of air slot and robot. (4) Conclusions: Location tracking and display provide decision support to inspectors and lay the groundwork for automated data collection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Behavioral Robotics Approach to Radiation Mapping Using Adaptive Sampling

Radiation mapping is a desirable task to automate because of the inherent risks involved and its tedious nature. A novel system was designed to address this by combining various existing technologies, utilizing behavior-based robotics and Bayesian optimization. The system uses a quadruped robot equipped with a manipulator and gamma detector to take measurements at locations that are selected based on the uncertainty of a surrogate model used to estimate the true radiation field. The robot uses input from the world with depth cameras to avoid collisions with the robot’s body, and unreachable points for the end effector are addressed by both allowing for a soft collision with the environment to occur, prompting the system to abandon that point, and varying the exploration tendency of the optimization based on consecutive collisions. This approach provides unique traversability and adaptability over other strategies in the literature. Experiments were performed by placing a Cesium-137 source on the ground and varying geometric setups and an optimization parameter demonstrating the adaptability to diverse environments and the increased robustness resulting from the designed behavior. The results additionally demonstrate that dynamically adjusting the optimization algorithm’s exploration tendency based on the arm’s collision history improves the system’s ability to navigate cluttered environments and construct accurate radiation maps without getting stuck in unreachable areas.

Adams, Joel↗