Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

The vertical ozone distribution during maximum and minimum solar activity

To study the latitude variation of ozone vertical distribution the complex experiment was carried out in February to July 1985 between 40 deg N to 70 deg S at the Pacific and the Indian Oceans. The great bulk of their data network were taken by the optical rocket ozonometers at the Southern Hemisphere. The results were compared with reference models containing the most extensive set of ozone observations from VS satellites between 1978 and 1982. To analyze latitude-season ozone variability at fixed altitude levels the experimental ozone concentration data were confirmed with model equatorial data. To compare the experimental data with reference model data, analogous model values were calculated. The results of calculation indicated a good agreement between experimental and reference model data of relative latitude-season variations of ozone concentration. Maximum variability is observed at 50 km in the equator and not exceeded 15 percent in the other regions at all altitude levels.

Kokin, G. A.↗

Influence of data uncertainty on cold season threshold-based climate indices

Climate indices are used to reduce the complex climate system and its changes to simple measures. The data basis – whether observational data or climate model data – to which the climate indices are applied, is usually subject to uncertainties. For threshold-based climate indices, the data uncertainty influences the threshold value, and, hence, the uncertainty can influence the values for the climate index. What the actual impacts of these uncertainties are on threshold-based climate indices is examined in this paper. The focus is not only on the climate model uncertainty, but also on the observational data uncertainty. The general sensitivity of each of the chosen climate indices to arbitrary changes in the threshold is studied. This shows a higher sensitivity of indices assessing extremes (ice days, heavy precipitation days) to changes in the threshold than indices that integrate a quantity over a given time interval (coldsum, consecutive days). For assessing an ensemble of climate model data with respect to their ability to reproduce the index values for current climate, the reference data uncertainty is applied to the chosen threshold-based climate indices by changing their threshold value by its corresponding uncertainty. It is shown that the climate model uncertainty can be within the range of the reference data uncertainty. When using threshold-based climate indices to assess changes in future climate periods, uncertainties should always be taken into account and ideally corrected in an appropriate way. This is especially important for indices that assess extremes.

54 ENVIRONMENTAL SCIENCES↗

Intestinal Malabsorption in Long-Term Survivors of Cervical Cancer Treated With Radiotherapy

Purpose: The aim of this cross-sectional study is to investigate the associations between pelvic radiotherapy (RT) and markers of intestinal absorption in cervical cancer survivors (CCSs). We compared patient data with normative data from a reference population and explored the associations between cobalamin status and clinically significant diarrhea and depression. Methods and Materials: Fifty-five CCSs treated with RT in 1994-1999 were included in 2005 in a follow-up questionnaire study exploring physical and psychological symptoms. Blood tests, including serum (S)-vitamin B{sub 12,} S-methylmalonic acid, S-folate, erythrocyte-folate, and plasma homocysteine, were analyzed. Differences in median values between CCSs and reference populations were evaluated by using Wilcoxon tests. Associations between variables were examined by means of multiple regression analyses. Results: Median S-vitamin B{sub 12} level was significantly lower and median S-methylmalonic acid level was significantly higher in CCSs compared with the reference population (p < 0.001). Correction for renal function verified a likely cobalamin deficiency in 20% of CCSs (11 of 55). Diarrhea or depression was not significantly related to any of the mentioned markers of cobalamin or folate status. Fifteen percent of CCSs (8 of 55) had subnormal S-calcium values. Conclusions: Significant cobalamin deficiency was observed in 11 (20%) and low calcium level was observed in 8 CCSs (15%) 6-12 years after pelvic RT. Neither diarrhea nor depression was associated with this deficiency. Routine monitoring of S-vitamin B{sub 12} level is recommended, and regular intake of cobalamin should be considered in CCSs treated with RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Silver nanowire based flexible electrodes with improved properties: High conductivity, transparency, adhesion and low haze

Graphical abstract: This graphical abstract illustrates the schematic representation of the main drawbacks and rectifications for AgNWs based transparent electrodes. - Highlights: • Films exhibited low sheet resistance and optical properties with R{sub s} ≤ 30 Ω/□ and T ≥ 90%. • We decreased haze to 2% by controlling AgNWs length, diameter, and concentration. • We achieved good adhesion for AgNWs on PET film. • There is no significant change in resistance in the bending angle from 0° to 180°, and on twisting. - Abstract: Recent work has been focusing on solution processable transparent electrodes for various applications including solar cells and displays. As well as, the research aims majorly at silver nanowires (AgNWs) to replace ITO. We enhance the transparent electrode performance as a function of optical and mechanical properties with low sheet resistance, by controlling the AgNWs accept ratios, ink composition, and processing conditions. The nanowire network of transparent films agrees with the 2D percolation law. The film transmittance values at 550 nm are coping with a reference ITO film. Sheet resistance and haze values are suitable for flexible electronic applications. We fabricate transparent flexible film using a low-cost processing technique.

36 MATERIALS SCIENCE↗

Electromagnetic properties for arbitrary spin particles: Natural electromagnetic moments from light-cone arguments

We revisit the old-standing problem of the electromagnetic interaction for particles of arbitrary spin. Based on the assumption that light-cone helicity at tree level and Q{sup 2}=0 should be conserved nontrivially by the electromagnetic interaction, we are able to derive all the natural electromagnetic moments for a pointlike particle of any spin. We provide here a transparent decomposition of the electromagnetic current in terms of covariant vertex functions. We also define in a general way the electromagnetic multipole form factors, and show their relation with the electromagnetic moments and covariant vertex functions. The light-cone helicity conservation argument determines uniquely the values of all electromagnetic moments, which we refer to as the 'natural' ones. These specific values are in accordance with the standard model, and the prediction of universal g=2 gyromagnetic factor is naturally recovered. We provide a very simple and compact formula for these natural moments. As an application of our results, we generalize the discussion of quark transverse charge densities to particles with arbitrary spin, giving more physical support to the light-cone helicity conservation argument.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Orbital-free density functional theory implementation with the projector augmented-wave method

We present a computational scheme for orbital-free density functional theory (OFDFT) that simultaneously provides access to all-electron values and preserves the OFDFT linear scaling as a function of the system size. Using the projector augmented-wave method (PAW) in combination with real-space methods, we overcome some obstacles faced by other available implementation schemes. Specifically, the advantages of using the PAW method are twofold. First, PAW reproduces all-electron values offering freedom in adjusting the convergence parameters and the atomic setups allow tuning the numerical accuracy per element. Second, PAW can provide a solution to some of the convergence problems exhibited in other OFDFT implementations based on Kohn-Sham (KS) codes. Using PAW and real-space methods, our orbital-free results agree with the reference all-electron values with a mean absolute error of 10 meV and the number of iterations required by the self-consistent cycle is comparable to the KS method. The comparison of all-electron and pseudopotential bulk modulus and lattice constant reveal an enormous difference, demonstrating that in order to assess the performance of OFDFT functionals it is necessary to use implementations that obtain all-electron values. The proposed combination of methods is the most promising route currently available. We finally show that a parametrized kinetic energy functional can give lattice constants and bulk moduli comparable in accuracy to those obtained by the KS PBE method, exemplified with the case of diamond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Transference Number

The performance of rechargeable batteries and other electrochemical systems depends on the rate at which the working ion (often a cation) is transported from one electrode to the other. The cation transference number is an important transport parameter that affects this rate. The purpose of this perspective is to distinguish between approximate and rigorous methods used in the literature to measure the transference number. We emphasize the fact that this parameter is dependent on the reference frame used in the analysis; care must be taken when comparing values obtained from different sources to account for differences in reference frames. We present data obtained from a well‐characterized electrolyte. We compare rigorously determined transference numbers in two reference frames with values obtained by an approximate method. We conclude with a qualitative discussion of the relationship between the transference number and salt concentration gradients that are obtained when current is drawn through a battery.

Gao, Kevin W.↗

Sheath-induced distortions in particle distributions near enhanced polar outflow probe particle sensors

We discuss sheath and kinetic effects on ion and electron distribution functions at the aperture of enhanced Polar Outflow Probe particle sensors. For this purpose, the interaction between the CASSIOPE spacecraft and space environment is simulated fully kinetically using the electrostatic Particle In Cell code PTetra. The simulations account for the geometry of the main features of the spacecraft body, the booms, and the sensors. In addition to the background plasma, the model also accounts for Earth magnetic field. The plasma parameters assumed in the simulations are obtained from the latest version of the International Reference Ionosphere (IRI) model and the value of magnetic field is obtained from the International Geophysical Reference Field model. Our analysis shows significant distortions in the ion distribution function in the plane of the sensor aperture, as well as in the direction along the boom holding the sensor. We argue that significant distortions and asymmetries should also occur at the aperture of the suprathermal electron imager when suprathermal electrons are detected, with energies of 5 eV or more.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small-angle neutron scattering measurements of δ-phase deuteride (hydride) precipitates in Zircaloy 4

Small-angle neutron scattering (SANS) measurements have been performed under ambient conditions to characterize deuteride (hydride) particles in Zircaloy 4, a fuel cladding material used in pressurized light-water nuclear reactors. Hydrogen pickup by the cladding leads to a rim structure in which large circumferential hydride plate-like particles preferentially form on the cooler water-side region of the cladding. Deuterium substitution has been used to increase the coherent response and decrease the incoherent background of the SANS measurements. Four bulk deuterium concentrations were investigated, approximately 100, 400, 500 and 1000 parts per million by weight (w.p.p.m.) deuterium, as well as a zero-deuterium-concentration reference sample. The net SANS response from the deuteride phase was determined at all concentration values after subtraction of the reference SANS response, which effectively subtracted the strong scattering from second-phase particles in as-received Zircaloy. The net SANS response consisted of strong Porod scattering from deuteride particles over the entire measured Q range (0.005–0.4 Å -1 ). The net SANS response was anisotropic at concentrations greater than 100 w.p.p.m. and required elliptical averaging analysis. A significant sample orientation effect on the intensity of the SANS response was observed, due to preferential alignment of deuteride particles. The effect of ex situ applied stress at elevated temperature on deuteride phase dissolution and reprecipitation was investigated; a weak effect was observed with SANS that could not be confirmed by optical microscopy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reliability of Current Biokinetic and Dosimetric Models for Radionuclides: A Pilot Study

This report describes the results of a pilot study of the reliability of the biokinetic and dosimetric models currently used by the U.S. Nuclear Regulatory Commission (NRC) as predictors of dose per unit internal or external exposure to radionuclides. The study examines the feasibility of critically evaluating the accuracy of these models for a comprehensive set of radionuclides of concern to the NRC. Each critical evaluation would include: identification of discrepancies between the models and current databases; characterization of uncertainties in model predictions of dose per unit intake or unit external exposure; characterization of variability in dose per unit intake or unit external exposure; and evaluation of prospects for development of more accurate models. Uncertainty refers here to the level of knowledge of a central value for a population, and variability refers to quantitative differences between different members of a population. This pilot study provides a critical assessment of models for selected radionuclides representing different levels of knowledge of dose per unit exposure. The main conclusions of this study are as follows: (1) To optimize the use of available NRC resources, the full study should focus on radionuclides most frequently encountered in the workplace or environment. A list of 50 radionuclides is proposed. (2) The reliability of a dose coefficient for inhalation or ingestion of a radionuclide (i.e., an estimate of dose per unit intake) may depend strongly on the specific application. Multiple characterizations of the uncertainty in a dose coefficient for inhalation or ingestion of a radionuclide may be needed for different forms of the radionuclide and different levels of information of that form available to the dose analyst. (3) A meaningful characterization of variability in dose per unit intake of a radionuclide requires detailed information on the biokinetics of the radionuclide and hence is not feasible for many infrequently studied radionuclides. (4) The biokinetics of a radionuclide in the human body typically represents the greatest source of uncertainty or variability in dose per unit intake. (5) Characterization of uncertainty in dose per unit exposure is generally a more straightforward problem for external exposure than for intake of a radionuclide. (6) For many radionuclides the most important outcome of a large-scale critical evaluation of databases and biokinetic models for radionuclides is expected to be the improvement of current models. Many of the current models do not fully or accurately reflect available radiobiological or physiological information, either because the models are outdated or because they were based on selective or uncritical use of data or inadequate model structures. In such cases the models should be replaced with physiologically realistic models that incorporate a wider spectrum of information.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-792: Validation of a Secondary TPS for IROC-H Recalculation of Anthropomorphic Phantoms

Purpose: To validate a secondary treatment planning system (sTPS) for use by the Imaging & Radiation Oncology Core-Houston (IROC-H). The TPS will recalculate phantom irradiations submitted by institutions to IROC-H and compare plan results of the institution to the sTPS. Methods: In-field dosimetric data was collected by IROC-H for numerous linacs at 6, 10, 15, and 18 MV. The data was aggregated and used to define reference linac classes; each class was then modeled in the sTPS (Mobius3D) by matching the in-field characteristics. Fields used to collect IROC-H data were recreated and recalculated using Mobius3D. The same dosimetric points were measured in the recalculation and compared to the initial collection data. Additionally, a 6MV Monte Carlo beam configuration was used to compare penumbrae in the Mobius3D models. Finally, a handful of IROC-H head and neck phantoms were recalculated using Mobius3D. Results: Recalculation and quantification of differences between reference data and Mobius3D values resulted in a relative matching score of 12.45 (0 is a perfect match) for the default 6MV Mobius3D beam configuration. By adjusting beam configuration options, iterations resulted in scores of 8.45, 6.32, and 3.52, showing that customization could have a dramatic effect on beam configuration. After in-field optimization, penumbra was compared between Monte Carlo and Mobius3D for the reference fields. For open jaw fields, FWHM field widths and penumbra widths were different by <0.6 and <1mm respectively; for MLC open fields the penumbra widths were up to 1.5mm different. Phantom recalculations showed good agreement, having an average of 0.6% error per beam. Conclusion: A secondary TPS has been validated for simple irradiation geometries using reference data collected by IROC-H. The beam was customized to the reference data iteratively and resulted in a good match. This system can provide independent recalculation of phantom plans based on independent reference data.

60 APPLIED LIFE SCIENCES↗

The 2025 Evaluation of Experimental Thermonuclear Reaction Rates (ETR25)

This work describes the formalism for estimating thermonuclear reaction rates for astrophysical applications, emphasizing modern statistical approaches such as Monte Carlo sampling and Bayesian models. We discuss related topics including the calculation of resonance energies from nuclear Q values, indirect estimates of particle partial widths, and matching of reaction rates at elevated temperatures to statistical model results. We have evaluated available experimental data on cross sections, resonance energies and strengths, partial widths, lifetimes, spin-parities, and spectroscopic factors. Based on these results, we have estimated numerical values of 78 experimental charged-particle thermonuclear reaction rates for target nuclei in the A = 2–40 mass region, for temperatures ranging from 1 MK to 10 GK. For each reaction, three rate values are provided: low, median, and high, corresponding to the 16th, 50th, and 84th percentiles, respectively, of the cumulative reaction rate probability density distribution. Additionally, we present the factor uncertainty of each rate at each temperature grid point. These results enable users to sample the reaction rate probability density in nucleosynthesis calculations, facilitating uncertainty estimates of nuclidic abundances. The rates presented here refer to their laboratory values. For use in stellar model simulations, these values need to be corrected for the effects of thermal excitations of the interacting nuclei. For each reaction, we include graphs that illustrate the fractional contributions to the overall reaction rate along with the associated uncertainty. These visuals are designed to assist both stellar modelers and nuclear experimentalists by identifying the primary sources of rate uncertain=^texttx);ty at specific stellar temperatures. A graphical comparison with earlier Monte Carlo rates is also provided.

Nuclear astrophysics↗

Radiological Modeling for Determination of Derived Concentration Levels of an Area with Uranium Residual Material - 13533

As a result of a pilot project developed at the old Spanish 'Junta de Energia Nuclear' to extract uranium from ores, tailings materials were generated. Most of these residual materials were sent back to different uranium mines, but a small amount of it was mixed with conventional building materials and deposited near the old plant until the surrounding ground was flattened. The affected land is included in an area under institutional control and used as recreational area. At the time of processing, uranium isotopes were separated but other radionuclides of the uranium decay series as Th-230, Ra-226 and daughters remain in the residue. Recently, the analyses of samples taken at different ground's depths confirmed their presence. This paper presents the methodology used to calculate the derived concentration level to ensure that the reference dose level of 0.1 mSv y-1 used as radiological criteria. In this study, a radiological impact assessment was performed modeling the area as recreational scenario. The modelization study was carried out with the code RESRAD considering as exposure pathways, external irradiation, inadvertent ingestion of soil, inhalation of resuspended particles, and inhalation of radon (Rn-222). As result was concluded that, if the concentration of Ra-226 in the first 15 cm of soil is lower than, 0.34 Bq g{sup -1}, the dose would not exceed the reference dose. Applying this value as a derived concentration level and comparing with the results of measurements on the ground, some areas with a concentration of activity slightly higher than latter were found. In these zones the remediation proposal has been to cover with a layer of 15 cm of clean material. This action represents a reduction of 85% of the dose and ensures compliance with the reference dose. (authors)

54 ENVIRONMENTAL SCIENCES↗

Scatter factors assessment in microbeam radiation therapy

Purpose: The success of the preclinical studies in Microbeam Radiation Therapy (MRT) paved the way to the clinical trials under preparation at the Biomedical Beamline of the European Synchrotron Radiation Facility. Within this framework, an accurate determination of the deposited dose is crucial. With that aim, the scatter factors, which translate the absolute dose measured in reference conditions (2 x 2 cm{sup 2} field size at 2 cm-depth in water) to peak doses, were assessed. Methods: Monte Carlo (MC) simulations were performed with two different widely used codes, PENELOPE and GEANT4, for the sake of safety. The scatter factors were obtained as the ratio of the doses that are deposited by a microbeam and by a field of reference size, at the reference depth. The calculated values were compared with the experimental data obtained by radiochromic (ISP HD-810) films and a PTW 34070 large area chamber. Results: The scatter factors for different microbeam field sizes assessed by the two MC codes were in agreement and reproduced the experimental data within uncertainty bars. Those correction factors were shown to be non-negligible for the future MRT clinical settings: an average 30% lower dose was deposited by a 50 {mu}m microbeam with respect to the reference conditions. Conclusions: For the first time, the scatter factors in MRT were systematically studied. They constitute an essential key to deposit accurate doses in the forthcoming clinical trials in MRT. The good agreement between the different calculations and the experimental data confirms the reliability of this challenging micrometric dose estimation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Depth‐dependent concentrations of hematopoietic stem cells in the adult skeleton: Implications for active marrow dosimetry

Purpose The hematopoietically active (or red) bone marrow is the target tissue assigned in skeletal dosimetry models for assessment of stochastic effects (leukemia induction) as well as tissue reactions (marrow toxicity). Active marrow, however, is in reality a surrogate tissue region for specific cell populations, namely the hematopoietic stem and progenitor cells. Present models of active marrow dosimetry implicitly assume that these cells are uniformly localized throughout the marrow spaces of trabecular spongiosa. Data from Watchman et al. and Bourke et al., however, clearly indicate that there is a substantial spatial concentration gradient of these cells with the highest concentrations localized near the bone trabeculae surfaces. The purpose of the present study was thus to explore the dosimetric implications of these spatial gradients on active marrow dosimetry. Methods Images of several bone sites from a 45‐yr female were retagged to group active marrow voxels into 50 μm increments of marrow depth, after which electron and alpha‐particle depth‐dependent specific absorbed fractions were computed for four source tissues — active marrow, inactive marrow, bone trabeculae volumes, and bone trabeculae surfaces. Corresponding depth‐dependent S values (dose to a target tissue per decay in a source tissue) were computed and further weighted by the relative target cell concentration. These depth‐weighted radionuclide S values were systematically compared to the more traditional volume‐averaged radionuclide S values of the MIRD schema for both individual bones of the skeleton and their skeletal‐averaged quantities. Results For both beta‐emitters and alpha‐emitters localized in the active and inactive marrow, depth‐weighted S values were shown to differ from volume‐averaged S values by only a few percent, as dose gradients across the marrow tissues are nonexistent. For bone volume and bone surface sources of alpha‐emitters and lower energy beta‐emitters, when marrow dose gradients are expected, explicit consideration of target cell spatial concentration gradients are shown to significantly impact marrow dosimetry. Conclusions For medical isotopes currently utilized for treatment of skeletal metastases, namely 153 Sm and 223 Ra, accounting for hematopoietic stem and progenitor cell concentration gradients resulted in maximum percent differences to reference skeletal‐averaged S values of ~21% and 55%, respectively.

Geyer, Amy M.↗

The Lyman β forest as a cosmic thermometer

We present a comprehensive analysis of high resolution hydrodynamic simulations in terms of Lyman α and Lyman β one dimensional flux power spectra P{sub αα} and P{sub ββ}). In particular, we focus on the behaviour that the flux auto-power spectra and cross-power spectra P{sub αβ}) display when the intergalactic medium (IGM) thermal history is changed in a range of values that bracket a reference model, while cosmological parameters are kept fixed to best fit the cosmic microwave background data. We present empirical fits that describe at the sub-percent level the dependence of the power spectra on the thermal parameters. At the largest scales, the power spectra show a constant bias between each other that is set by the parameters describing the IGM thermal state. The cross-power spectrum has an oscillatory pattern and crosses zero at a scale which depends on T{sub 0}, the IGM temperature at the mean density, for reasonable values of the power-law index γ of the IGM temperature-density relation T=T{sub 0}(1+δ){sup γ-1}). By performing a Fisher matrix analysis, we find that the power spectrum P{sub ββ} is more sensitive to the thermal history than P{sub αα} alone, due to the fact that it probes denser regions than Lyman α. When we combine the power and cross spectra the constraints on γ can be improved by a factor ∼ 4, while the constraints on T{sub 0} improve by a factor of ∼ 2. We address the role of signal-to-noise and resolution by mocking realistic observations and we conclude that the framework presented in this work can significantly improve the knowledge of the IGM thermal state, which will in turn guarantee better constraints on IGM-derived cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiative-convective model with an explicit hydrologic cycle. 2: Sensitivity to large changes in solar forcing

The one-dimensional radiative-convective equilibrium model with an explicit hydrologic cycle introduced in part 1 is used to study the sensitivity of the model's atmosphere to large changes in the solar forcing, when various cumulus convection parameterizations are used. When the concentration of the absorbing as in the atmosphere is temperature dependent, equilibrium is impossible for values of the solar forcing larger than a critical value. This result is referred to as a runaway greenhouse. The cumulus convection parameterization schemes currently in use in global climate models (GCMs) employ different assumptions about moistening. This causes the critical solar forcing above which a runaway greenhouse occurs to be very sensitive to the cumulus convection scheme employed. Furthermore, we show that the sensitivity of the equilibrium temperature to changes in the solar forcing depends crucially on the microphysics of cumulus convection. For fixed cloud conditions, the critical forcing for a runaway greenhouse to occur is between approximately 1.22 and 1.49 times the global mean value for the Earth, and for clear sky conditions, it is a few percent lower. The runaway greenhouse in the experiments with the mass flux schemes generally occurs more rapidly than in the experiments with the adjustment schemes. In addition, the inability of the hard convective adjustment scheme to produce an efficient vertical transport of moisture, together with the saturation requirement for convection to occur, leads to the breakdown of the radiative-convective equilibria when other processes are not available to provide the necessary vertical transport of water vapor.

Renno, Nilton O.↗