Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Using Cosmic Ray Muons to Assess Geological Characteristics in the Subsurface

This is a technical presentation that does not take into account contractual limitations or obligations under the Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (Standard Contract) (10 CFR Part 961). For example, under the provisions of the Standard Contract, spent nuclear fuel in multi-assembly canisters is not an acceptable waste form, absent a mutually agreed to contract amendment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Activities at Pacific Northwest National Laboratory to Advance Nuclear Radiation Science among Underrepresented STEM Students

The Partnership for Radiation Studies (PaRS) consortium is a collaboration between two minority-serving institutions and two U.S. national laboratories. The five-year consortium is funded by the U.S. Department of Energy’s (DOE) National Nuclear Security Administration (NNSA), and it aims enhance workforce of underrepresented students in STEM disciplines. PaRS’ long-term goal is to train students for their prospective hiring in DOE laboratories and sites. As one of the two integral national laboratory partners, the Pacific Northwest National Laboratory (PNNL) is playing an integral role in achieving this goal via pertinent lectures, seminars, hands-on trainings, and outreach activities. This paper summarizes PNNL’s key activities and initiatives to train the next generation of underrepresented students in STEM disciplines.

Minority Serving Institutions Partnership Program,↗

Multiaxis sensing system for detection of airborne molecules and radionuclides

Various technologies presented herein relate to a method and equipment for detecting both airborne radioisotope and molecular effluent gases. Multi-Axis Sensing can be conducted by utilizing a pressurized MOF sorbent, such as a scintillating Metal-Organic Frameworks (S-MOFs). These MOFs are crystalline nanoporous materials that have synthetic versatility that allow adjustment of pore size, chemical environment, and luminescence properties. A method for detecting an analyte in a fluid sample is provided that comprises: loading a sorbent with a sample fluid, wherein the sorbent comprises a MOF material; pressurizing the sample fluid to increase the fluid in the sorbent thereby making a pressurized sorbent; and detecting ionizing radiation or a chemical property of the analyte in the pressurized sorbent.

Allendorf, Mark D.↗

In-situ characterization of a background calibration line for east coast aerial measuring

Report outlines the methodology used to establish a background calibration line for AMS-East operations at Joint Base Andrews. The results provide a general isotopic characterization of the soil within the calibration line at Joint Base Andrews, and the expected terrestrial exposure rate which can be used to aerial measuring.

61 RADIATION PROTECTION AND DOSIMETRY↗

Infrared studies of galactic nebulae. IV - Continuum and line radiation from planetary nebulae.

Observations are reported of the detection of IR radiation from several planetary nebulae not previously known to be radiating at these wavelengths. Broad spectral bandwidth observations indicate that ir radiation in excess of that expected from atomic processes is a common phenomenon among these objects. Investigations with narrow spectral bandwidth show that in a few cases the energy in the 10.52-micron line is a significant fraction of the total energy observed in the broad-band measurements and in other cases a relatively small fraction of the total radiation. Other observations on two sources with narrow spectral bandwidth adjacent to the 10.52-micron line indicate that at these wavelengths a true continuum of radiation exists as well as lines. The results are discussed in relation to visual and radio-wavelength data.

Gillett, F. C.↗

Laser Spiderweb Sensor Used with Portable Handheld Devices

A portable spectrometer, including a smart phone case storing a portable spectrometer, wherein the portable spectrometer includes a cavity; a source for emitting electromagnetic radiation that is directed on a sample in the cavity, wherein the electromagnetic radiation is reflected within the cavity to form multiple passes of the electromagnetic radiation through the sample; a detector for detecting the electromagnetic radiation after the electromagnetic radiation has made the multiple passes through the sample in the cavity, the detector outputting a signal in response to the detecting; and a device for communicating the signal to a smart phone, wherein the smart phone executes an application that performs a spectral analysis of the signal.

Scott, David C.↗

A study of wave propagation in a duct and mode radiation

In this paper we discuss two problems of classical duct acoustics: (1) wave propagation in infinite ducts with uniform flow based on a graphical approach, and (2) detection of mode radiation from a duct by an external circular microphone array. In (1) we show that the wave number vectors for a given flow Mach number form an ellipse whose center and shape depend on the Mach number only. We construct graphically the upstream and downstream wave number vectors of modes that propagate in the duct. We then show how one can infer from this graphical approach many known results in duct propagation such as the mode cut-off concept, the direction of energy propagation, the angle of the radiation lobe at peak directivity using Rice' s cutoff ratio concept, and other qualitative results. In (2) we give the mathematics behind the experimental detection of mode radiation from a duct by a circular array of microphones whose axis coincides with the engine axis. Since the external microphone array does not introduce additional noise sources inside the engine, as does a rotating rake of microphones positioned at the inlet, this measurement technique may be preferable to use of a rotating rake. The simplicity afforded by the lack of sophisticated rotating parts is an additional advantage over the rotating array.

Farassat, F.↗

Quantum Dot Based Solid-State Radiation Detectors

The detection and accurate identification of nuclear material is critical to the advancement of national security, medical technology, and environmental prosperity. The gold standard solid-state detector HPGe, suffers from high manufacturing costs and the need to operate at cryogenic temperatures to ensure reliable energy resolution. The other most common solid-state detector, cadmium zinc telluride (CZT), has the ability to operate at room temperature, but the grow process results in impurities decreasing performance. In this paper we have developed a continuous flow synthesis able to mass produce targeted size cadmium selenide quantum dots. The implementation of these QDs in QD/MEH-PPV composites has the ability to rival HPGe energy resolution at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in CdZnTeSe for Radiation Detector Applications

Detection of X- and gamma-rays is essential to a wide range of applications from medical imaging to high energy physics, astronomy, and homeland security. Cadmium zinc telluride (CZT) is the most widely used material for room-temperature detector applications and has been fulfilling the requirements for growing detection demands over the last three decades. However, CZT still suffers from the presence of a high density of performance-limiting defects, such as sub-grain boundary networks and Te inclusions. Cadmium zinc telluride selenide (CZTS) is an emerging material with compelling properties that mitigate some of the long-standing issues seen in CZT. This new quaternary is free from sub-grain boundary networks and possesses very few Te inclusions. In addition, the material offers a high degree of compositional homogeneity. The advancement of CZTS has accelerated through investigations of the material properties and virtual Frisch-grid (VFG) detector performance. The excellent material quality with highly reduced performance-limiting defects elevates the importance of CZTS as a potential replacement to CZT at a substantially lower cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel Study of HEND, RAD, and DAN Instrument Response to Martian Radiation and Surface Conditions

Nuclear detection methods are being used to understand the radiation environment at Mars. JPL (Jet Propulsion Laboratory) assets on Mars include: Orbiter -2001 Mars Odyssey [High Energy Neutron Detector (HEND)]; Mars Science Laboratory Rover -Curiosity [(Radiation Assessment Detector (RAD); Dynamic Albedo Neutron (DAN))]. Spacecraft have instruments able to detect ionizing and non-ionizing radiation. Instrument response on orbit and on the surface of Mars to space weather and local conditions [is discussed] - Data available at NASA-PDS (Planetary Data System).

Mars↗

Detection of 511 keV positron annihilation radiation from the galactic center direction

A balloon-borne gamma ray telescope with an approximately 130 cu cm high purity germanium detector was flown over Australia to detect sharp spectral features from the galactic center direction. A 511 keV positron annihilation line was observed at a flux level of (1.21 plus or minus 0.22) x (10/cu cm) photons/sec/sp cm. Suggestive evidence for the detection of the three-photon positronium continuum is presented. The possible origin of the positrons is discussed.

Leventhal, M.↗

Radiant Temperature Nulling Radiometer

A self-calibrating nulling radiometer for non-contact temperature measurement of an object, such as a body of water, employs a black body source as a temperature reference, an optomechanical mechanism, e.g., a chopper, to switch back and forth between measuring the temperature of the black body source and that of a test source, and an infrared detection technique. The radiometer functions by measuring radiance of both the test and the reference black body sources; adjusting the temperature of the reference black body so that its radiance is equivalent to the test source; and, measuring the temperature of the reference black body at this point using a precision contact-type temperature sensor, to determine the radiative temperature of the test source. The radiation from both sources is detected by an infrared detector that converts the detected radiation to an electrical signal that is fed with a chopper reference signal to an error signal generator, such as a synchronous detector, that creates a precision rectified signal that is approximately proportional to the difference between the temperature of the reference black body and that of the test infrared source. This error signal is then used in a feedback loop to adjust the reference black body temperature until it equals that of the test source, at which point the error signal is nulled to zero. The chopper mechanism operates at one or more Hertz allowing minimization of l/f noise. It also provides pure chopping between the black body and the test source and allows continuous measurements.

Robert Ryan↗

Anomaly Detection in Gamma Spectra Using Hopfield Neural Network with B-SAT and Grover’s Algorithm on a Quantum Computing Simulator

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. In principle, gamma radiation sources can be detected and identified by their unique spectral lines. However, detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. In recent prior work, we have developed a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm to detect a weak signal anomaly hidden among the highly fluctuating background spectra. The objective of this work is to explore quantum computing methods to increase the speed of HNN. The approach is based on the Grover’s search algorithm in conjunction with a 3-SAT problem formalism. The Grover’s algorithm is implemented on a quantum computing simulator using Qiskit software. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign, where the anomaly is a subset of measurements containing a 137 Cs source. Results indicate that using Grover’s algorithm on a quantum simulator reduces runtime of HNN by two orders of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗