Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Improving the performance of mid-T baked niobium cavities through post-bake surface treatment

The Medium temperature (mid-T) baking of niobium superconducting radio-frequency cavities at 300 350 C in a vacuum furnace is known to enhance the quality factor (Q₀). However, despite this improvement, cavities treated with this process often exhibit premature quench at relatively low accelerating fields. This limitation is suspected to arise from the formation of surface contaminants, such as niobium carbides, during the furnace bake at 350 C for 3 h. To investigate the influence of potential surface contamination, this study applied an ultralight chemical removal to 1.3 GHz and 650 MHz single-cell cavities that had undergone medium-temperature baking. The removal of the top RF surface layer led to a notable improvement in the quench field and Q₀, indicating a beneficial effect of eliminating possible surface residues introduced during the bake.

Chouhan, V. [Fermilab] (ORCID:0000000282004931)↗

Modeling of Thermal Quench in Superconducting RF Cavities

Superconducting radio frequency (SRF) cavities are often limited by thermal quench, which is an excessive electromagnetic heating that occurs in the high magnetic field area and expands thereafter forcing the cavity to lose its superconducting state. In this paper, we demonstrate how the quench phenomena can be modeled using a coupled electromagnetic thermal analysis. The proposed model takes into account the nonlinearity of the material properties at cryogenic temperature and the effect of Kapitza resistance. The proposed approach is used to compute the thermal quench field of a 3.9 GHz 9-cell accelerating cavity, a 2.815 GHz deflecting cavity, and a 1.3GHz 9-cell accelerating cavity. Here, the computed values of quenchfield are in good agreement with the measured ones observedduring vertical testing at 2 K. Without loss of generality, theproposed methodology can be applied to other cavity geometries.

43 PARTICLE ACCELERATORS↗

Phase-controlled improvement of photon lifetime in coupled superconducting cavities

High-quality cavities are crucial for various fundamental physical studies and applications. Here we find that by coupling two cavities directly or via a phase-tunable coupling channel, the photon lifetime of the local field can exceed that of the bare cavities. The cavity photon lifetime is modified by the phases of the initial states and the phase accumulation on the coupling channel, which affect the interference between cavities. In experiments, by coupling superconducting radio-frequency cavities via phase-tunable cables, we realize a factor of 2 improvement in the cavity photon lifetime. The results can bring rich revenue to quantum information science, sensing, and high-energy physics.

43 PARTICLE ACCELERATORS↗

First Results from two Nb3Sn Cavities Assembled in a CEBAF Quarter Cryomodule

Two 1.5 GHz CEBAF C75-shape 5-cell accelerator cavities were coated with Nb3Sn film using the vapor diffusion technique at Fermilab and Jefferson Labcoating facilities. Both cavities were measured at 4 K and 2 K in the vertical cavity test facility (VCTF) in each lab, then assembled into a CEBAF quartercryomodule at Jefferson Lab. The cryomodule was tested at 4 K and 2 K in the CryoModule Test Facility (CMTF) at Jefferson Lab. RF test results for bothcavities in the cryomodule are similar to those in the qualification test in VTS, with one cavity reaching Eacc =7.9 MV/m and the other - 13.3 MV/m at 4 K

Eremeev, G.↗

Capture Cavities for the CW Polarized Positron Source Ce+BAF

The initial design of the capture cavities for a continuous wave (CW) polarized positron beam for the Continuous Electron Beam Accelerator Facility (CEBAF) up-grade at Jefferson Lab is presented. A chain of standing wave multi-cell copper cavities inside a solenoid channel are selected to capture positrons in CW mode. The cavity shunt impedance is surveyed by tuning the cavity geometry while considering accommodating large phase space distribution positron beams with large beam pipe radius while ensuring a large enough passband mode separation. The RF field wall loss power and maximum wall loss power density are considered in cavity and waveguide design. A range of design parameters are given for larger system optimization when the capture cavities are considered together with thermal calculation and beam dynamics in next phase of work.

Wang, S.↗

Impact of lithium wall conditioning and wave-frequency on high density lower hybrid current drive experiment on EAST

A series of dedicated lower hybrid current drive (LHCD) experiments on EAST shows that lithium wall conditioning extends LH current drive and heating up to the line-averaged density of n ̅_e≈ 4x1019 m-3 for both 2.45 and 4.6 GHz. Current drive at such a high density is crucial for the development of long-pulse non-inductive scenarios on EAST. With lithiation, the LH power injection of 1.5 MW at 2.45 GHz resulted in a drop of loop voltage of ~ 0.3 V, which is a comparable loop voltage drop observed with 1.1 MW at 4.6 GHz. The observed decrease in loop voltage is attributed mostly to the RF heating effect. Another LHCD experiment suggests that lithium wall coating has a more significant impact on the scrape-off-layer (SOL) properties than changes in the Greenwald fraction. LHCD at 2.45 GHz still suffers from a loss of efficiency. Enhanced power ionization in front of the launcher may cause the onset of density-dependent wave instabilities. The rise in the midplane SOL density may also accelerate a transition in the divertor regime, leading to additional ionization and collisional losses in the X-point divertor plasma. Ray-tracing modeling supports that a lower wave frequency is more prone to collisional power loss. The experiments confirm that lithiation is a useful tool to control the SOL plasma, and suggest that density control in front of the launcher may be critical to mitigating power loss mechanisms in the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Results from Two Nb3Sn Cavities Assembled in a CEBAF Quarter Cryomodule

Two 1.5 GHz CEBAF C75-shape 5-cell accelerator cavities were coated with Nb3Sn film using the vapor diffusion technique at Fermilab and Jefferson Lab coating facilities. Both cavities were measured at 4 K and 2 K in the vertical cavity test facility (VCTF) in each lab, then assembled into a CEBAF quarter cryomodule at Jefferson Lab. The cryomodule was tested at 4 K and 2 K in the CryoModule Test Facility (CMTF) at Jefferson Lab. RF test results for both cavities in the cryomodule are similar to those in the qualification test in VTS, with one cavity reaching Eacc = 7.9 MV/m and the other - 13.3 MV/m at 4 K.

Eremeev, G.↗

Detection of high-frequency gravitational waves using SRF cavities

Today, apart from some isolated R&D efforts, there are no gravitational wave (GW) experiments, yet which explore a large part of the vast frequency range above the LIGO/Virgo band. It is planned to establish an experiment at Deutsches Elektronen-Synchrotron (DESY) and at the Superconducting Quantum Materials and Systems (SQMS) Center at Fermi National Accelerator Laboratory (Fermilab) to search for high-frequency GWs in the frequency range of 10 kHz to 100 MHz. The basic idea is to use superconducting radiofrequency (SRF) cavities to detect tiny harmonic deformations induced by GWs which change the boundary conditions of the oscillating electromagnetic field. This paper summarizes the challenging environmental boundary requirements, and the R&D to operate a cavity using a low level RF (LLRF) system which pushes beyond state-of-the-art accuracy and resolutions and a seismic noise mitigated cryostat at 1.8 K. The focus of this paper is the warm and cold commissioning of a prototype cavity, built 20 years ago during the MAGO collaboration, and its first measurement in our collaborative research project.

Wenskat, M. [DESY; Hamburg U.] (ORCID:000000016546↗

Low RF loss DC conductive ceramic for RF windows

Charging of RF windows has historically been problematic, frequently resulting in damage to the window severe enough that the window needs to be replaced. Many attempts have been made to prevent charging and therefore improve window lifetime, the most successful and common of which is coating the window with titanium nitride (TiN). Surface coatings such as TiN rely on the secondary electron yield of the coating material being lower than that of the ceramic window material, reducing the number of electrons emitted from a variety of mechanisms. An alternative approach is to introduce a small amount of DC conductivity to the ceramic itself, turning the traditionally insulating window into a mildly conductive one. This allows any charge on the surface of the window to drain rather than build until a discharge happens. A magnesium titanate ceramic has been developed with a small DC conductivity and used to make RF windows. Several window assemblies have been produced and tested, including 1.3 GHz waveguide and 650 MHz coaxial designs. The results of the conductive ceramic window test program will be presented.

43 PARTICLE ACCELERATORS↗

Simulations of RHIC Spin Flipper

The extensive APEX studies of the RHIC Spin Flipper were performed during FY17 achieving up to 97 % spin flip efficiency at both injection (23.8 GeV) and store (255 GeV) energy, using 9 MHz and 197 MHz RF system. The Zgoubi simulations were setup to reproduce the experimental conditions. The results of the APEX measurements and the numerical simulations are compared here, showing a good agreement especially at injection energy. The additional simulations of the spin flip efficiency, with the 28 MHz and 197 MHz RF system, show that a stronger Spin Flipper is needed in order to achieve good (|P f /P i | > 99 %) spin flip efficiency during the nominal physics store running conditions at 255 GeV.

43 PARTICLE ACCELERATORS↗

Microstructural Characterization of Nb$_3$Sn Thin Films Using FIB Tomography

The accelerating gradient of N b3Sn superconducting radiofrequency (SRF) cavities is currently limited, and the underlying cause remains an open question in the field. One leading hypothesis attributes this limitation to the presence of tin-deficient regions within the N b3Sn coating, which can suppress the superheating field. Due to the relatively large coherence length of N b3Sn, defects near the surface may significantly interact with the RF field. However, these subsurface defects have proven difficult to characterize. This research aims to investigate the structure and distribution of subsurface Sn deficient regions to better understand their influence on cavity performance. We employ focused ion beam (FIB) tomography to analyze the subsurface microstructure of N b3Sn thin films. This technique enables threedimensional reconstruction of both the tin distribution and the grain structure within the film. By correlating Sn content with grain structure, we find that Sn deficient regions are more prevalent that previously thought. However, the Sn deficient regions are consistently located below the surface of the film where RF fields are strongly attenuated by supercurrent screening and are likely not a limiting factor for cavity performance

Viklund, Eric [Fermilab]↗

A Miniaturized Laser Heterodyne Radiometer for a Global Ground-Based Column Carbon Monitoring Network

We present progress in the development of a passive, miniaturized Laser Heterodyne Radiometer (mini-LHR) that will measure key greenhouse gases (C02, CH4, CO) in the atmospheric column as well as their respective altitude profiles, and O2 for a measure of atmospheric pressure. Laser heterodyne radiometry is a spectroscopic method that borrows from radio receiver technology. In this technique, a weak incoming signal containing information of interest is mixed with a stronger signal (local oscillator) at a nearby frequency. In this case, the weak signal is sunlight that has undergone absorption by a trace gas of interest and the local oscillator is a distributive feedback (DFB) laser that is tuned to a wavelength near the absorption feature of the trace gas. Mixing the sunlight with the laser light, in a fast photoreceiver, results in a beat signal in the RF. The amplitude of the beat signal tracks the concentration of the trace gas in the atmospheric column. The mini-LHR operates in tandem with AERONET, a global network of more than 450 aerosol sensing instruments. This partnership simplifies the instrument design and provides an established global network into which the mini-LHR can rapidly expand. This network offers coverage in key arctic regions (not covered by OCO-2) where accelerated warming due to the release of CO2 and CH4 from thawing tundra and permafrost is a concern as well as an uninterrupted data record that will both bridge gaps in data sets and offer validation for key flight missions such as OCO-2, OCO-3, and ASCENDS. Currently, the only ground global network that routinely measures multiple greenhouse gases in the atmospheric column is TCCON (Total Column Carbon Observing Network) with 18 operational sites worldwide and two in the US. Cost and size of TCCON installations will limit the potential for expansion, We offer a low-cost $30Klunit) solution to supplement these measurements with the added benefit of an established aerosol optical depth measurement. Aerosols induce a radiative effect that is an important modulator of regional carbon cycles. Changes in the diffuse radiative flux fraction (DRF) due to aerosol loading have the potential to alter the terrestrial carbon exchange.

Wilson, Emily L.↗

Beam Dynamics simulations for ERDC project -- SRF linac for industrial use

Compact conductively cooled SRF industrial linacs can provide unique parameters of the electron beam for industrial applications. (up to 10MeV, 1MW). For ERDC project we designed normal conducting RF injector with thermal RF gridded gun integrated in first cell of multi-cell cavities. For design of the RF gun we used MICHELLE software to simulate and optimize parameters of the beam. Output file was converted to ASTRA format and most beam dynamic simulations in multi-cell normal conducting cavity and cryomodule were performed by using ASTRA software. For cross-checking we compare results of MICHELLE and AS-TRA in first few cells. At the end of injector beam reach ~250keV energy which allow to trap bunch in acceleration regime without losses in TESLA like 1.3 GHz cavity. Short solenoid at the end of injector allow to regulate transverse beam size in cryomodule to match beam to extraction system and also reduce charge losses in accelerator.

43 PARTICLE ACCELERATORS↗

Beam Dynamics Simulations of Transient Beam Loading Effects in the 10GeV EIC Electron Storage Ring

We report on beam dynamics studies of transient beam loading effects in the 10 GeV EIC electron storage ring [1]. The studies are carried out with time-dependent Vlasov-Fokker-Planck simulations performed with the parallel, particle tracking code SPACE [2], which allows to follow self-consistently the dynamics of h bunches, where h in the number of RF buckets, in arbitrary multi-bunch configurations. The specific goal of the numerical simulations is to determine stable RF cavity settings under heavy beam loading. We also study the option to operate with a passive, third-harmonic cavity (3HC) system for bunch lengthening, addressing both stability and the performance limitation due to a gap in the uniform filling pattern for ion clearing.

43 PARTICLE ACCELERATORS↗

Study of Conduction-Cooled Superconducting Quadrupole Magnets Combined with Dipole Correctors for the ILC Main Linac

A superconducting rf (SRF) cryomodule for International Linear Collider(ILC) Main Linac equips focus/steering magnets. The magnets are "superferric" magnets with four superconducting (SC) race track coils conductively cooled from the cryomodule LHe supply pipe. The quadrupole field gradient and dipole field are 40 T/m and 0.1 T, respectively. The magnet length and iron-pole radius are 1 m and 0.045 m, respectively. It is known that dark current is generated at SRF cavities and accelerated through the following linac string. The dark current reaches and heats the SC magnets. It is estimated that the power deposition in the magnet may reach more than a few watts and temperature of the SC coils may locally reach to critical temperature of NbTi. It is important to make the magnet not reach quench with sufficient conduction cooling. We aim to realize the SC magnet which can stably operate under such condition. We plan to develop test coils made of three types of SC materials, NbTi, Nb₃Sn, and MgB₂ and study thermal characteristics and stability . We will develop a short model magnet, based on the test coil results. Here, we will present the magnet design study and the R&D plan.

43 PARTICLE ACCELERATORS↗

Record of Decision: H - LEBT Design Modifications

The LAMP Conceptual Design (LCD) is described in the LAMP Conceptual Design Report. The proposed new configuration of the LAMP H - LEBT encompasses multiple changes to the LCD. The new configuration makes use of a single H - source to supply beam to all LANSCE user stations except IPF; this eliminates one of the H - sources in the LCD, and the associated pulsed merger magnet the use of two such sources required. The source current from the sole H - source is gated on a macropulse-by-macropulse basis using techniques demonstrated at SNS (Spallation Neutron Source), specifically, changes to the RF plasma drive power. A pulsed electrode system is used to match the beam into the LEBT transport line, variable on a macropulse-by-macropulse basis to match the source beam current.

43 PARTICLE ACCELERATORS↗