Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Improving Zr cross sections: 90 Zr(n, y) [Slides]

This presentation covers key take-aways such as the first of 4 isotopes (90,91,92,94) to be measured. 91 Zr is currently being measured at GELINA. Once all measurements are done a join evaluation with SAMMY will be undertaken. Further, there will be production of new evaluated resonance parameters and covariances. New data will be used to improve evaluation information, benefitting transport calculations of reactors, waste storage, etc.

07 ISOTOPE AND RADIATION SOURCES↗

ORNL Contributions to the ENDF/B-VIII.1 Library [Slides]

For uranium and plutonium isotopes, evaluation work is converging to a stable configuration with an overall satisfactory benchmark performance (more information on the validation tests after CSEWG). Strontium evaluation was included in the repository library and successfully tested by processing codes relative to an alternative quantification of the external function. Cerium covariance matrices were updated to address review comments on the magnitude of the uncertainty. For future uncertainty quantification, theoretical observables should be properly decoupled from current measured guidelines. Tests to correctly include LP (from resonance parameters) fitted to measured energy-averaged data are in progress. Current ENDF files contains experimental LP data.

07 ISOTOPE AND RADIATION SOURCES↗

FRAM In-Depth [Slides]

FRAM is an isotopic analysis code nominally designed for plutonium and uranium. It can also analyze other materials such as spent fuel (off all ages), medical isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Mark-18A Cold Runs

The Savannah River National Laboratory (SRNL) is tasked by the National Nuclear Security Administration (NNSA) to recover highly valued isotopes from irradiated Mark-18A (Mk-18A) targets. The Savannah River Site (SRS) has sixty-five Mk-18A targets available for the recovery of the high valued materials. The sixty-five Mk-18A targets are currently stored in the L-Area Basin and will be removed one at a time and individually transported to SRNL. Upon receipt at SRNL, the Mk-18A target material will be removed from the confinement, dissolved, chemically separated, and calcined to a stable oxide. The flowsheet is designed to recover the plutonium as well as the trivalent actinides. The remaining unrecovered material will be discarded to the high activity drain (HAD) system in SRNL. A specially designed cask was procured for transport of the targets from L-Area to SRNL. Once received at SRNL, the targets will be loaded into the back of Cell 7 and resized as they enter the cell. The resized targets (1/4 lengths) will then be processed one at a time through the following processes: caustic dissolution and filtration; acidic dissolution and filtration, Reillex anion exchange, diglycolamide (DGA) cation exchange; and DGA calcination. This processing will result in two product streams. The first is an aqueous plutonium solution which will be removed from the shielded cells and taken to a glovebox for further purification and conversion to an oxide. The second is a calcined oxide containing the Am and Cm as well as other lanthanide fission products which will be removed from the shielded cells using a bagless transfer system. Both materials will be packaged for shipment to Oak Ridge National Laboratory (ORNL). All equipment to carry out this process was designed, procured or fabricated, and installed in a mock-up facility (716-4A) at SRS to allow for simulation testing in a non-radioactive area. This equipment was then dismantled and transferred from 716-4A to 773-A and installed in the SRNL Shielded Cells. After installation in the shielded cells facility testing was performed using water followed by surrogates and cold chemicals. Issues were identified during these evaluations, including equipment issues as well as technical challenges. Many of the issues were rectified during performance of the cold runs, and the remaining have a resolution identified. Table ES-1 provides a summary of all issues identified during the cold run operations, as well as the status and identified resolutions to outstanding issues.

07 ISOTOPE AND RADIATION SOURCES↗

Production Facility Simulations for Annular LEU Targets

Eden Radioisotopes, LLC is designing a new molybdenum-99 (Mo-99) production facility based on a TRIGA-sized reactor with a core composed of low enriched uranium (LEU) targets. Reactor production is designed to exceed U.S. demand for Mo-99 using the fission processes. The nominal operational power is 1.8MW (less than 2.0MW, to satisfy the “non-power” reactor requirement) and desired irradiation scenarios include 7, 14, or 21 days of the irradiation for each target element. Safety limits for reactor operating margins are associated with such physical phenomena as fission gas release, fuel swelling, and stress cracking. As shown in the literature, one of the critical parameters defining safety margins for metallic uranium fuel is swelling. In its turn the fuel operational temperature is the main parameter impacting the swelling rate. This report documents the results of consecutive studies of reactor criticality, fission energy depositions, and cooling conditions for the target. The maximum temperature calculated for the LEU targets allows us to choose appropriate modeling approximation of the swelling. All obtained results refer to the preliminary targets and core designs provided by Eden. A criticality analysis was performed, and the results are listed mainly to cross-check Eden’s safety report and assume maximal neutron field disturbance for maximal reactivity. A brief description of the metallic uranium swelling model is provided in the Appendix.

07 ISOTOPE AND RADIATION SOURCES↗

Irradiation of Mo-100 Targets and Testing Fe(ll)CI 2 Precipitation for Tc-99 Removal

The production of molybdenum-99 (Mo-99) is a critical step in the generation of technetium-99m (Tc-99m), a radioisotope widely used in medical imaging. NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope Mo-99 through a photonuclear reaction on molybdenum-100 (Mo-100). Accelerator production of Mo-99 using enriched Mo-100 targets yields undesirable isotopes, such as niobium-95 (Nb-95) and zirconium-95 (Zr-95). Previous studies reported that Nb and Zr isotopes can be effectively removed from Mo-99 products through coprecipitation with Fe(III). To enable the potential utilization of the first milking of Tc-99m from a Mo-99/Tc-99m generator, it is desirable to remove long-lived Tc-99. This can be accomplished by substituting Fe(III) with Fe(II) during the precipitation step, without affecting the removal of Zr and Nb isotopes. Previous experiments demonstrated up to 99+% removal of Tc using this method. It was also observed that the presence of hydrogen peroxide significantly impacts Tc removal. This was evident in the processing of enriched Mo-100 targets, where only 25% of Tc was removed. To further investigate this, another irradiation of enriched Mo-100 disks was conducted, followed by Tc-99 removal using Fe(II). Prior to irradiation, experimental conditions for Tc removal were optimized through several test runs using Mo-100 disks spiked with Tc-99. The results of these tests are discussed in this report.

07 ISOTOPE AND RADIATION SOURCES↗

Recovery of Enriched Mo-100 from Low Specific Activity Mo-99/Tc-99m Generator Waste Streams

This study assessed two potential techniques for the extraction of pure Mo-100 target material from Mo-99/Tc-99m waste streams: 1) an established solvent-extraction method tailored for Mo-99 spent solution recycling, and 2) a low-temperature molten salt electrochemical process. By making minor modifications to the conventional solvent extraction method, particularly to accommodate the altered solubility limits arising from elevated Na+ concentrations in the waste, we achieved quantitative Mo recoveries. Although the electrochemical technique offers advantages in scalability and processing simplicity, it proved ineffective in recovering Mo from a NaOH-KOH salt melt.

07 ISOTOPE AND RADIATION SOURCES↗

Equivalency Factors and Mixed Isotope Subcritical Limits [Slides]

Equivalency factors (EF) are coefficients used to express the reactivity of a quantity of a given isotope in terms of an equivalent amount of another isotope’s reactivity. EFs are often used to conservatively determine if a given mixed-isotope system is within previously established limits. These EFs are calculated by taking ratios of established subcritical limits, also called the Rule of Fractions.

07 ISOTOPE AND RADIATION SOURCES↗

Safeguards Technology Development Program: FY 2024 Mid-Year Report

This project has 2 major thrusts and 2 minor tasks – One of the major ones is a scoping study for improving uranium isotopics by analyzing higher energy, lower yield U-235 gamma emissions. The second major one benefits past projects such as auto-enrichment, and peak-based analysis routines previously added to GADRAS-DRF [1]. The two minor tasks involve an in-person or remote GADRAS-DRF training for the IAEA, and characterizing detectors of interest.

07 ISOTOPE AND RADIATION SOURCES↗

Design of Hypothetical Processes for the Production of 131 I and 99 Mo from Activation Targets

For over six decades, medical isotope production has been a high-priority focus of many research reactors across the globe. The majority of these isotopes were produced using highly-enriched uranium (HEU) or low enriched uranium (LEU) – delivering millions of doses of diagnostic and therapeutic isotopes. As a consequence of this production, however, six decades of isotope production has resulted in massive quantities of spent uranium material worldwide with no known disposition pathway creating growing proliferation concerns. Supported by the National Nuclear Security Administration’s (NNSA) Material Management and Minimization (M3) program, there has been increased focus in the production of high-priority isotopes without special nuclear materials or without uranium altogether. Isotope production via activation can potentially fulfill regional isotope demands – particularly in under-developed regions without access to isotope supply chains. The benefits of this approach would be a reduction in uranium proliferation risks, less special nuclear material wastes, and reduced risk of supply disruption in the likely event that major isotope producers will again go off-line as has happened in recent years due to a number of factors.

07 ISOTOPE AND RADIATION SOURCES↗

GADRAS-DRF Enhancements for Safeguards – Custom Peak Fitting to Enhance Model Fitting and Isotopics

One major software update was accomplished within the Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF) package. This update allows users to adjust individual peak fits for use in subsequent analysis processes within GADRAS-DRF. A graphical user interface (GUI) was implemented so users can see the effect of their fit adjustments on the spectrum. This new feature will enhance the capability of the previously funded auto-enrichment and peak-based 1D model fit feature that was implemented in FY23 (Fiscal Year). Isotopic analysis was performed using M400 data obtained from uranium standards and the isotopic assessment is given with and without manual peak adjustments.

07 ISOTOPE AND RADIATION SOURCES↗

Scalable Enrichment of 48 Ca at the Solid/liquid Interface by Chemical and Electrochemical Methods

This award targets to develop methods to enrich 48 Ca, which is a critical isotope for synthesizing superheavy elements and testing the standard model through neutrinoless double beta decay. The team first tested chemical exchange-based separation between solids and liquids, which is based on the free energy change due to the different vibrational frequencies caused by Ca isotopes in a material. However, the separation factor (alpha), which is defined as the ratio of 40 Ca/ 48 Ca ratios in the two phases, only reach ~1.01. The team then developed liquid centrifugation-based isotope separation, where a Ca salt aqueous solution is centrifuged at a speed of ~60 kRPM, and 48 Ca is enriched at the bottom of a centrifuge tube due to its larger mass. A high α of ~1.2-1.4 is achieved for 40 Ca/ 48 Ca at 40 °C. This method is further approved to be generic for any isotope that can be dissolved in a liquid solution or form liquid chemicals near room temperature. The experimental results also align well with modeling prediction. The team further develop a model to evaluate isotope separation in countercurrent liquid centrifugation. The team found that the countercurrent configuration can also enhance isotope separation in liquids, similar with gas centrifugation, which boost separation for isotopes which are difficult to be gasified near room temperature.

07 ISOTOPE AND RADIATION SOURCES↗

“Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation”

Radioisotopes are essential for the development and application of radiopharmaceuticals that target specific diseases, such as cancer, offering unique potential for precision medicine. The growing demand for theranostic radioisotopes underscores their critical role in personalized medicine, where they enhance diagnostic imaging, minimize patient radiation exposure, and improve targeted tissue uptake, particularly in receptor- and antigen-directed therapies. The theranostic pair terbium-155 (diagnostic) and terbium-161 (therapeutic) holds significant promise for advancing individualized, targeted, and dosimetry-driven radiotherapies. However, the United States currently lacks routine and reliable production of these isotopes. This project made significant progress toward addressing this supply issue by developing production and separation methods for terbium-155 and terbium-161 while also training the next generation of the nuclear and radiochemistry workforce. This grant also strengthened collaboration between scientists at the University of Washington, the University of Missouri and Brookhaven National Laboratory. The research effort focused on evaluating target preparation methods, optimizing irradiation parameters, and refining isolation processes. In addition, the project provided extensive hands-on training to graduate students and postdoctoral fellows, equipping them with expertise in radioisotope production technologies and fostering the growth of the nuclear science workforce.

07 ISOTOPE AND RADIATION SOURCES↗

Investigating Similarity Differences for Light-water-Moderated and Polyethylene-Moderated Systems

Oak Ridge National Laboratory has performed validation studies in support of Pacific Northwest National Laboratory’s analysis of the Sum-of-Fractions method. Work in a companion paper examines the validation methods and results for various mixtures of fissile isotopes in various concentrations moderated and reflected by water and polyethylene. Those results indicate a greater coverage of critical experiments for validating water moderated and reflected systems versus those moderated and reflected with polyethylene.

07 ISOTOPE AND RADIATION SOURCES↗

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7 Li (CRADA 626) Final Report

The intent of this project was to determine appropriate methodologies for analysis of lithium isotopes for 1) quasi-online monitoring of isotope separations, and 2) high-precision characterization of end-products, including lithium fluoride and lithium-beryllium fluoride (FLiBe). Traditionally, isotopic analysis requires the use of expensive, sophisticated instrumentation with often relatively long analytical timelines. We determined that the use of cheaper, smaller, and easier-to-operate instruments are sufficient for rapid analysis of lithium isotopes to monitor isotope separation efficiencies. In addition, we found that the analytical precision afforded by these lower-cost instruments is comparable to the more sophisticated (i.e., more expensive) instrumentation when the isotopic composition of lithium becomes highly depleted in 6Li. This finding will ultimately help lower costs of manufacturing of depleted lithium that is required for operation of certain designs of Generation IV nuclear reactors.

07 ISOTOPE AND RADIATION SOURCES↗

FRAM v.7.1

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr3) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of the Multi-Coincident Bismuth Germanate Oxide Spectrometer at the Nuclear Counting Facility

A multi-detector γ-ray spectroscopy system including 3 high-purity germanium (HPGe) detectors has been developed at the Nuclear Counting Facility at Lawrence Livermore National Laboratory. This system operates not only in conventional singles γ-ray detection mode but also incorporates features like coincidence and anti-coincidence techniques. These advanced detection modes can significantly enhance the system’s sensitivity, making it a powerful tool for isotope identification and quantification, especially for complex samples with high background and overlapping peaks. In this re port, we present a comprehensive performance characterization of the Multi-Coincident Bismuth Oxide Spectrometer (MCBOS) using a variety of sample types, including 60 Co, 48 Sc, and mixed fission product samples. Each sample provides unique tests for the MCBOS capabilities. Additionally, a GEANT4 model of the MCBOS has been generated to aid with the characterization of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗