Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Integrated Lateral Flow Test Strip with Electrochemical Sensor for Quantification of Phosphorylated Cholinesterase: Biomarker of Exposure to Organophosphorus Agents

An integrated lateral flow test strip with electrochemical sensor (LFTSES) device with rapid, selective and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of post-exposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. The proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with detection limit of 0.02 nM. Based on this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values, but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents.

59 BASIC BIOLOGICAL SCIENCES↗

Long-Gradient Separations Coupled with Selected Reaction Monitoring for Highly Sensitive, Large Scale Targeted Protein Quantification in a Single Analysis

Long-gradient separations coupled to tandem MS were recently demonstrated to provide a deep proteome coverage for global proteomics; however, such long-gradient separations have not been explored for targeted proteomics. Herein, we investigate the potential performance of the long-gradient separations coupled with selected reaction monitoring (LG-SRM) for targeted protein quantification. Direct comparison of LG-SRM (5 h gradient) and conventional LC-SRM (45 min gradient) showed that the long-gradient separations significantly reduced background interference levels and provided an 8- to 100-fold improvement in LOQ for target proteins in human female serum. Based on at least one surrogate peptide per protein, an LOQ of 10 ng/mL was achieved for the two spiked proteins in non-depleted human serum. The LG-SRM detection of seven out of eight endogenous plasma proteins expressed at ng/mL or sub-ng/mL levels in clinical patient sera was also demonstrated. A correlation coefficient of >0.99 was observed for the results of LG-SRM and ELISA measurements for prostate-specific antigen (PSA) in selected patient sera. Further enhancement of LG-SRM sensitivity was achieved by applying front-end IgY14 immunoaffinity depletion. Besides improved sensitivity, LG-SRM offers at least 3 times higher multiplexing capacity than conventional LC-SRM due to ~3-fold increase in average peak widths for a 300-min gradient compared to a 45-min gradient. Therefore, LG-SRM holds great potential for bridging the gap between global and targeted proteomics due to its advantages in both sensitivity and multiplexing capacity.

Shi, Tujin↗

Electrochemical Branched-DNA Assay for Polymerase Chain Reaction-Free Detection and Quantification of Oncogenes in Messenger RNA

We describe a novel electrochemical branched-DNA (bDNA) assay for polymerase chain reaction (PCR)-free detection and quantification of p185 BCR-ABL leukemia fusion transcript in the population of messenger RNA (mRNA) extracted from cell lines. The bDNA amplifier carrying high loading of alkaline phosphatase (ALP) tracers was used to amplify targets signal. The targets were captured on microplate well surfaces through cooperative sandwich hybridization prior to the labeling of bDNA. The activity of captured ALP was monitored by square-wave voltammetric (SWV) analysis of the electroactive enzymatic product in the presence of 1-napthyl-phosphate. The specificity and sensitivity of assay enabled direct detection of target transcript in as little as 4.6 ng mRNA without PCR amplification. In combination with the use of a well-quantified standard, the electrochemical bDNA assay was capable of direct use for a PCR-free quantitative analysis of target transcript in total mRNA population. The approach thus provides a simple, sensitive, accurate and quantitative tool alternate to the RQ-PCR for early disease diagnosis.

59 BASIC BIOLOGICAL SCIENCES↗

Quantification of Technetium-99 in Complex Groundwater Matrixes using a Radiometric Preconcentrating Minicolumn Sensor in an Equilibration-based Sensing Approach

A preconcentrating minicolumn sensor for pertechnetate detection in water consists of a packed bed containing a mixture of anion exchange resin and scintillating plastic beads. The column materials are contained in a transparent plastic flow cell placed between two photomultiplier tubes for radiometric detection. Upon retention of pertechnetate anions, the radioactive decay of Tc-99 results in detectable scintillation pulses that are counted in coincidence. In equilibration-based sensing mode, the sample is pumped through the packed bed until complete chromatographic equilibrium is achieved between the activity concentration in the water sample and the concentration on the anion exchange resin. The analytical signal is the observed steady state count rate at equilibrium. The sensitivity is related to a measurement efficiency parameter that is the product of the retention volume and the absolute radiometric detection efficiency. This sensor can readily detect pertechnetate to levels ten times below the drinking water standard of 0.033 Bq/mL. The potential for other anions in natural groundwater and contaminated groundwater plumes to interfere with pertechnetate detection and quantification have been examined in detail, with reference to the groundwater chemistry at the Hanford Site in Washington State. Individual anions such as nitrate, carbonate, chloride and iodide, at natural or elevated concentrations, do not interfere significantly with pertechnetate uptake on the anion exchange resin. Elevated chromate or sulfate anion concentrations can interfere with pertechnetate uptake by the resin, but only at levels substantially higher than typical concentrations in groundwater or contamination plumes. Nevertheless, elevated anion concentrations may reduce pertechnetate uptake and sensitivity of the sensor when present in combination. Chromate is retained on the anion exchange resin from water at ppb levels, leading to an orange stain that interferes with pertechnetate detection by the absorption of scintillation light pulses (color quench). Radioactivity from radioiodine, tritium, and uranium are not expected to create a significant positive bias in groundwater analyses. A method of automated fluidic standard addition is demonstrated that corrects for matrix interferences leading to accurate analyses over a wide range of groundwater compositions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Internal Standard Triggered-Parallel Reaction Monitoring Mass Spectrometry Enables Multiplexed Quantification of Candidate Biomarkers in Plasma

Despite advances in proteomic technologies, clinical translation of plasma biomarkers remains low, partly due to a major bottleneck between the discovery of candidate biomarkers and costly clinical validation studies. Due to a dearth of multiplexable assays, generally only a few candidate biomarkers are tested, and the validation success rate is accordingly low. Previously, mass spectrometry-based approaches have been used to fill this gap but feature poor quantitative performance and were generally limited to hundreds of proteins. Here, we demonstrate the capability of an internal standard triggered-parallel reaction monitoring (IS-PRM) assay to greatly expand the numbers of candidates that can be tested with improved quantitative performance. The assay couples immunodepletion and fractionation with IS-PRM and was developed and implemented in human plasma to quantify 5176 peptides representing 1314 breast cancer biomarker candidates. Characterization of the IS-PRM assay demonstrated the precision (median % CV of 7.7%), linearity (median R 2 > 0.999 over 4 orders of magnitude), and sensitivity (median LLOQ < 1 fmol, approximately) to enable rank-ordering of candidate biomarkers for validation studies. Using three plasma pools from breast cancer patients and three control pools, 893 proteins were quantified, of which 162 candidate biomarkers were verified in at least one of the cancer pools and 22 were verified in all three cancer pools. The assay greatly expands capabilities for quantification of large numbers of proteins and is well suited for prioritization of viable candidate biomarkers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of Hydrogen Isotopes Utilizing Raman Spectroscopy Paired with Chemometric Analysis for Application across Multiple Systems

On-line and real-time analysis of a chemical process is a major analytical challenge that can drastically change the way the chemical industry or chemical research operates. With in situ analyses, new and powerful understanding of chemistry can be gained; however, building robust tools for long-term monitoring faces many challenges that include compensating for instrument drift, instrument replacement, and sensor or probe replacement. Accounting for these changes by recollecting calibration data and rebuilding quantification models can be costly and time consuming. Here, in this study, methods to overcome these challenges are demonstrated with an application of Raman spectroscopy to monitoring hydrogen isotopes with varied speciation within dynamic gas streams. Specifically, chemical data science tools such as chemometric modeling are leveraged along with several examples of calibration transfer approaches. Furthermore, the optimization of instrument and sensors cell parameters for targeted gas phase analyses is discussed. While the particular focus on hydrogen is highly beneficial within the nuclear energy sector, mechanisms built and demonstrated here are widely applicable to optical spectroscopy monitoring in numerous other chemical systems that can be leveraged in other hazardous processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Cation–$π$ Interaction Enables a Halo-Tag Fluorogenic Probe for Fast No-Wash Live Cell Imaging and Gel-Free Protein Quantification

The design of fluorogenic probes for a Halo tag is highly desirable but challenging. Previous work achieved this goal by controlling the chemical switch of spirolactones upon the covalent conjugation between the Halo tag and probes or by incorporating a “channel dye” into the substrate binding tunnel of the Halo tag. In this work, we have developed a novel class of Halo-tag fluorogenic probes that are derived from solvatochromic fluorophores. The optimal probe, harboring a benzothiadiazole scaffold, exhibits a 1000-fold fluorescence enhancement upon reaction with the Halo tag. Structural, computational, and biochemical studies reveal that the benzene ring of a tryptophan residue engages in a cation–$π$ interaction with the dimethylamino electron-donating group of the benzothiadiazole fluorophore in its excited state. We further demonstrate using noncanonical fluorinated tryptophan that the cation–$π$ interaction directly contributes to the fluorogenicity of the benzothiadiazole fluorophore. Mechanistically, this interaction could contribute to the fluorogenicity by promoting the excited-state charge separation and inhibiting the twisting motion of the dimethylamino group, both leading to an enhanced fluorogenicity. Finally, we demonstrate the utility of the probe in no-wash direct imaging of Halo-tagged proteins in live cells. In addition, the fluorogenic nature of the probe enables a gel-free quantification of fusion proteins expressed in mammalian cells, an application that was not possible with previously nonfluorogenic Halo-tag probes. The unique mechanism revealed by this work suggests that incorporation of an excited-state cation–$π$ interaction could be a feasible strategy for enhancing the optical performance of fluorophores and fluorogenic sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effective Li-Ion Transport Quantification in Composite Cathodes for All-Solid-State Batteries via Multiscale Modeling and Experiments

The tortuosity factor of composite cathodes significantly affects the rate performance of all-solid-state batteries (ASSBs) and has significant differences from systems with liquid electrolytes. Here, in this work, we report a simulation-experiment combined approach that quantifies the effective Li-ion transport in an ASSB composite cathode, which links tortuosity factor on ∼ μm scale to terminal voltage during cycling at the cell level (on ∼ cm scale). Two independent approaches of tortuosity factor quantification are considered: fitting electrochemical cycling data and verifying at different cycling rates and calculating from segmented tomography images, with the tortuosity factor quantified from both methods reaching self-consistency. The simulated terminal voltage using the quantified tortuosity factor has a small relative error of <3% compared to the experimental measurements. We find a significantly reduced value of the Bruggeman exponent of the catholyte phase (1.75), and using shape analysis, we show that rod-shaped catholyte particles play an important role in lowering the tortuosity factor.

Yao, Archie Mingze [Univ. of Michigan, Ann Arbor, ↗

Quantification of Organic Porosity and Water Accessibility in Marcellus Shale Using Neutron Scattering

Pores within organic matter (OM) are a significant contributor to the total pore system in gas shales. These pores contribute most of the storage capacity in gas shales. Here we present a novel approach to characterize the OM pore structure (including the porosity, specific surface area, pore size distribution, and water accessibility) in Marcellus shale. By using ultrasmall and small-angle neutron scattering, and by exploiting the contrast matching of the shale matrix with suitable mixtures of deuterated and protonated water, both total and water-accessible porosity were measured on centimeter-sized samples from two boreholes from the nanometer to micrometer scale with good statistical coverage. Samples were also measured after combustion at 450 °C. Analysis of scattering data from these procedures allowed quantification of OM porosity and water accessibility. OM hosts 24–47% of the total porosity for both organic-rich and -poor samples. This porosity occupies as much as 29% of the OM volume. In contrast to the current paradigm in the literature that OM porosity is organophilic and therefore not likely to contain water, our results demonstrate that OM pores with widths >20 nm exhibit the characteristics of water accessibility. In conclusion, our approach reveals the complex structure and wetting behavior of the OM porosity at scales that are hard to interrogate using other techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing the Quantification of Critical Elements in WTE and Coal Ash via Alkaline Fusion: Superiority of Lithium Metaborate (LiBO 2 )

Ashes generated from coal combustion, as well as waste incineration, can be a potential source of critical elements necessary for the ongoing transition towards electrification and greener energy technologies. For the quantification of critical elements, traditional methods such as acid digestion are time-intensive and can fail to dissolve critical elements in refractory minerals. One potential solution is to adopt alkaline fusion for faster, total digestion. However, the role of flux choice and the subsequent digestion efficiency (DE) is unknown. Here, we report a systematic investigation on the feasibility of alkaline fusion with Lithium Metaborate (LiBO 2 ) and Lithium Tetraborate (Li 2 B 4 O 7 ) as fluxes for the digestion of two standard reference materials (BCR 176R and SRM 1633c). Our findings suggest that LiBO 2 yields higher DE values than Li 2 B 4 O 7 for several critical REEs and volatiles, such as Pb and Cd. Specifically, for REEs in SRM 1633c, the DE values with LiBO 2 are, on average, ~16 percent higher than those with Li 2 B 4 O 7 . Similarly, for Pb and Cd in BCR 176R, the DE values with LiBO 2 are ~20 percent higher than with Li 2 B 4 O 7 . These results suggest that LiBO 2 is a superior flux for rapid ash digestion.

01 COAL, LIGNITE, AND PEAT↗

Development of an Uncertainty Quantification Predictive Chemical Reaction Model for Syngas Combustion

An automated data-centric infrastructure, Process Informatics Model (PrIMe), was applied to validation and optimization of a syngas combustion model. The Bound-to-Bound Data Collaboration (B2BDC) module of PrIMe was employed to discover the limits of parameter modifications based on uncertainty quantification (UQ) and consistency analysis of the model–data system and experimental data, including shock-tube ignition delay times and laminar flame speeds. Existing syngas reaction models are reviewed, and the selected kinetic data are described in detail. Empirical rules were developed and applied to evaluate the uncertainty bounds of the literature experimental data. Here, the initial H 2 /CO reaction model, assembled from 73 reactions and 17 species, was subjected to a B2BDC analysis. For this purpose, a dataset was constructed that included a total of 167 experimental targets and 55 active model parameters. Consistency analysis of the composed dataset revealed disagreement between models and data. Further analysis suggested that removing 45 experimental targets, 8 of which were self-inconsistent, would lead to a consistent dataset. This dataset was subjected to a correlation analysis, which highlights possible directions for parameter modification and model improvement. Additionally, several methods of parameter optimization were applied, some of them unique to the B2BDC framework. The optimized models demonstrated improved agreement with experiments compared to the initially assembled model, and their predictions for experiments not included in the initial dataset (i.e., a blind prediction) were investigated. The results demonstrate benefits of applying the B2BDC methodology for developing predictive kinetic models.

01 COAL, LIGNITE, AND PEAT↗

Quantification of Mercury Bioavailability for Methylation Using Diffusive Gradient in Thin-Film Samplers

Here, mercury-contaminated sediment and water contain various Hg species, with a small fraction available for microbial conversion to the bioaccumulative neurotoxin monomethylmercury (MeHg). Quantification of this available Hg pool is needed to prioritize sites for risk management. This study compared the efficacy of diffusive gradient in thin-film (DGT) passive samplers to a thiol-based selective extraction method with glutathione (GSH) and conventional filtration (<0.2 μm) as indicators of Hg bioavailability. Anaerobic sediment slurry microcosms were amended with isotopically labeled inorganic Hg “endmembers” (dissolved Hg 2+ , Hg-humic acid, Hg-sorbed to FeS, HgS nanoparticles) with a known range of bioavailability and methylation potentials. Net MeHg production (expressed as percent of total Hg as MeHg) over 1 week correlated with mass accumulation of Hg endmembers on the DGTs and only sometimes correlated with the 0.2 μm filter passing Hg fraction and the GSH-extractable Hg fraction. These results suggest for the first time that inorganic Hg uptake in DGTs may indicate bioavailability for methylating microbes. Moreover, the methylating microbial community assessed by hgcA gene abundance was not always consistent with methylation rates between the experiments, indicating that knowledge of the methylating community should target the transcript or protein level. Altogether, these results suggest that DGTs could be used to quantify the bioavailable Hg fraction as part of a method to assess net MeHg production potential in the environment.

54 ENVIRONMENTAL SCIENCES↗

Single-Blind Quantification of Natural Gas Leaks from 1 km Distance Using Frequency Combs

A new method is tested in a single-blind study for detection, attribution, and quantification of methane emissions from the natural gas supply chain, which contribute substantially to annual U.S. emissions. The monitoring approach couples atmospheric methane concentration measurements from an open-path dual frequency comb laser spectrometer with meteorological data in an inversion to characterize emissions. During single-blind testing, the spectrometer is placed >1 km from decommissioned natural gas equipment configured with intentional leaks of control- lable rate. Single, steady emissions ranging from 0 to 10.7 g min -1 (0-34.7 scfh) are detected, located, and quantified at three gas pads of varying size and complexity. The system detects 100% of leaks, including leaks as small as 0.96 g min -1 (3.1 scfh). It attributes leaks to the correct pad or equipment group (tank battery, separator battery, wellhead battery) 100% of the time and to the correct equipment (specific separator, tank, or wellhead) 67% of the time. All leaks are quantified to within 3.7 g min -1 (12 scfh); 94% are quantified to within 2.8 g min -1 (9 scfh). Finally, these tests are an important initial demonstration of the methodology’s viability for continuous monitoring of large regions, with extension to other trace gases and industries.

03 NATURAL GAS↗

Nonintrusive Uncertainty Quantification of Computational Fluid Dynamics Simulations of a Bench-Scale Fluidized-Bed Gasifier

Uncertainty quantification (UQ) analysis is increasingly becoming one of the major requirements of simulation-based engineering to assess the confidence in the results and make better-informed decisions based on the insight derived from the simulations. In an earlier study, Bayesian UQ analysis was applied to existing bench-scale fluidized-bed gasifier experiment results. In the current study, a series of simulations were carried over with the open-source computational fluid dynamics software MFiX to reproduce the experimental conditions, where three operating factors, i.e., coal flow rate, coal particle diameter, and steam-to-oxygen ratio, were systematically varied to understand their effect on the syngas composition. Bayesian UQ analysis was this time performed on the numerical results for comparison purposes. This is part of ongoing research efforts to explore the applicability of advanced UQ methods and processes such as Bayesian methods for large-scale complex multiphase flow simulations. As part of Bayesian UQ analysis, a global sensitivity analysis was performed based on the simulation results, which shows that the predicted syngas composition is strongly affected not only by the steam-to-oxygen ratio (which was observed in experiments as well) but also by variation in the coal flow rate and particle diameter (which was not observed in experiments). The carbon monoxide mole fraction is underpredicted at lower steam-to-oxygen ratios and overpredicted at higher steam-to-oxygen ratios. The opposite trend is observed for the carbon dioxide mole fraction. These discrepancies are attributed to either excessive segregation of the phases that leads to the fuel-rich or -lean regions or alternatively the selection of reaction models, where different reaction models and kinetics can lead to different syngas compositions throughout the gasifier.

01 COAL, LIGNITE, AND PEAT↗

Online, real-time analysis of highly complex processing streams: Quantification of analytes in Hanford tank sample

Processing of hazardous materials is a crucial example of where on-line monitoring can significantly reduce operation risk, cost, and time. This is particularly true in the case of the Hanford site, where nuclear materials from the cold war era are being processed for environmental cleanup efforts. In exceedingly complex streams such as those at Hanford, on-line and real-time monitoring can be a challenge due to complexity of signals. Further obstacles are imposed by the caustic nature of processing streams as well as the radiation damage inflicted on instruments and probes. On-line monitoring based on Raman spectroscopy enables the detection of many Hanford tank species of interest, and was demonstrated here on nine chemical species that comprise the majority of tank waste by volume, including Al(OH)4-, C2O42-, CO32-, CrO42-, NO32-, NO3-, OH-, PO43-, SO42-. Real-time analysis of Raman signal allows for immediate quantification of target analytes and was successfully accomplished through the use of chemometric models. Furthermore, irradiation tests reveal Raman monitoring systems can effectively continue to operate even after receiving 1·107 Rad of gamma dose. The on-line, real-time monitoring system developed here was successfully used to simultaneously quantify nine target analytes in a real samples collected from Hanford tank AP-105.

Lines, Amanda M.↗

Quantification of Key Peroxy and Hydroperoxide Intermediates in the Low-Temperature Oxidation of Dimethyl Ether

Dimethyl ether (DME) oxidation is a model chemical system with a small number of prototypical reaction intermediates that also has practical importance for low-carbon transportation. Although it has been studied experimentally and theoretically, ambiguity remains in the relative importance of competing DME oxidation pathways in the low-temperature autoignition regime. To focus on the primary reactions in DME autoignition, we measured the time-resolved concentration of five intermediates, CH 3 OCH 2 OO (ROO), OOCH 2 OCH 2 OOH (OOQOOH), HOOCH 2 OCHO (hydroperoxymethyl formate, HPMF), CH 2 O, and CH 3 OCHO (methyl formate, MF), from photolytically initiated experiments. We performed these studies at P = 10 bar and T = 450-575 K, using a high-pressure photolysis reactor coupled to a time-of-flight mass spectrometer with tunable vacuum-ultraviolet synchrotron ionization at the Advanced Light Source. Our measurements reveal that the timescale of ROO decay and product formation is much shorter than predicted by current DME combustion models. The models also strongly underpredict the observed yields of CH 2 O and MF and do not capture the temperature dependence of OOQOOH and HPMF yields. Adding the ROO + OH $\rightarrow$ RO + HO 2 reaction to the chemical mechanism (with a rate coefficient approximated from similar reactions) improves the prediction of MF. Increasing the rate coefficients of ROO ↔ QOOH and QOOH + O 2 ↔ OOQOOH reactions brings the model predictions closer to experimental observations for OOQOOH and HPMF, while increasing the rate coefficient for the QOOH $\rightarrow$ 2 CH 2 O + OH reaction is needed to improve the predictions of formaldehyde. In conclusion, to aid future quantification of DME oxidation intermediates by photoionization mass spectrometry, we report experimentally determined ionization cross-sections for ROO, OOQOOH, and HPMF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Instrument for Time-Resolved OH and HO 2 Quantification in High-Pressure Laboratory Kinetics Studies

Here, we have constructed a new time-resolved high-pressure fluorescence assay by gas expansion (HP-FAGE) apparatus, optimized for the detection of OH and HO 2 radicals in complex gas-phase reactions. The new instrument fills a gap in the existing experimental toolkit for chemical kinetics by enabling the quantification of two key reactive species with microsecond time resolution from high-pressure sources, which was previously not attainable. The HP-FAGE is interfaced with a flow reactor, designed for pressures up to 100 bar and temperatures up to 1000 K, in which reactions are initiated by laser photolysis of radical precursors at repetition rates of 1–10 Hz. The HP-FAGE samples gas out of the reactor into a miniature FAGE chamber, where OH is detected by resonant laser-induced fluorescence using a time-delayed probe laser pulse. HO 2 is converted to OH via reaction with NO and then detected by OH fluorescence. The novel FAGE design places the probe region very close to the gas expansion, minimizing the transport time of sampled molecules and resulting in time resolution better than 20 μs for both OH and HO 2 . We calibrate the sensitivity of HP-FAGE, validate its performance with measurements of well-known reaction kinetics (OH + CH 4 , OH + OH, OH + HO 2 , and HO 2 + HO 2 ), and discuss prospects for its future use.

calibration↗

Quantification of Exciton Fine Structure Splitting in a Two-Dimensional Perovskite Compound

Applications of two-dimensional (2D) perovskites have significantly outpaced the understanding of many fundamental aspects of their photophysics. The optical response of 2D lead halide perovskites is dominated by strongly bound excitonic states. However, a comprehensive experimental verification of the exciton fine structure splitting and associated transition symmetries remains elusive. Here we employ low temperature magneto-optical spectroscopy to reveal the exciton fine structure of (PEA) 2 PbI 4 (here PEA is phenylethylammonium) single crystals. We observe two orthogonally polarized bright in-plane free exciton (FX) states, both accompanied by a manifold of phonon-dressed states that preserve the polarization of the corresponding FX state. Introducing a magnetic field perpendicular to the 2D plane, we resolve the lowest energy dark exciton state, which although theoretically predicted, has systematically escaped experimental observation (in Faraday configuration) until now. These results corroborate standard multiband, effective-mass theories for the exciton fine structure in 2D perovskites and provide valuable quantification of the fine structure splitting in (PEA) 2 PbI 4 .

36 MATERIALS SCIENCE↗